Convective transport processes in data centersRambo et al., 2006
- Document ID
- 5376435147623800785
- Author
- Rambo J
- Joshi Y
- Publication year
- Publication venue
- Numerical Heat Transfer, Part A: Applications
External Links
Snippet
Large computing infrastructure facilities are causing many thermal management issues due to the rapid increase in power density of data processing equipment. The complex air flow and thermal transport processes of air-cooled data centers are investigated computationally …
- 238000000034 method 0 title abstract description 36
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F17/00—Digital computing or data processing equipment or methods, specially adapted for specific functions
- G06F17/50—Computer-aided design
- G06F17/5009—Computer-aided design using simulation
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20718—Forced ventilation of a gaseous coolant
- H05K7/20745—Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F2217/00—Indexing scheme relating to computer aided design [CAD]
- G06F2217/78—Power analysis and optimization
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F2217/00—Indexing scheme relating to computer aided design [CAD]
- G06F2217/16—Numerical modeling
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06Q—DATA PROCESSING SYSTEMS OR METHODS, SPECIALLY ADAPTED FOR ADMINISTRATIVE, COMMERCIAL, FINANCIAL, MANAGERIAL, SUPERVISORY OR FORECASTING PURPOSES; SYSTEMS OR METHODS SPECIALLY ADAPTED FOR ADMINISTRATIVE, COMMERCIAL, FINANCIAL, MANAGERIAL, SUPERVISORY OR FORECASTING PURPOSES, NOT OTHERWISE PROVIDED FOR
- G06Q10/00—Administration; Management
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F2200/00—Indexing scheme relating to G06F1/04 - G06F1/32
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Alkharabsheh et al. | A brief overview of recent developments in thermal management in data centers | |
Nada et al. | Effect of CRAC units layout on thermal management of data center | |
Gupta et al. | Cooling architecture selection for air-cooled Data Centers by minimizing exergy destruction | |
AU2017202272A1 (en) | System And Method For Prediction Of Temperature Values In An Electronics System | |
Rambo et al. | Convective transport processes in data centers | |
Dalal et al. | Natural convection in a rectangular cavity heated from below and uniformly cooled from the top and both sides | |
Fernando et al. | Can a data center heat-flow model be scaled down? | |
Rambo et al. | Multi-scale modeling of high power density data centers | |
Samadiani et al. | The thermal design of a next generation data center: a conceptual exposition | |
Bhalerao et al. | Rapid prediction of exergy destruction in data centers due to airflow mixing | |
Rahman et al. | Effect of heat-generating solid body on mixed convection flow in a ventilated cavity | |
Mathew et al. | Experiment and numerical investigation on optimal distribution of discrete ICs for different orientation of substrate board | |
Icoz et al. | Numerical simulation of boundary conditions and the onset of instability in natural convection due to protruding thermal sources in an open rectangular channel | |
Macedo et al. | A parametric numerical study of the airflow and thermal performance in a real data center for improving sustainability | |
Luo et al. | Simulation of turbulent flow and forced convection in a triangular duct with internal ribbed surfaces | |
Erden et al. | A hybrid lumped capacitance-CFD model for the simulation of data center transients | |
Rambo et al. | Thermal performance metrics for arranging forced air cooled servers in a data processing cabinet | |
He et al. | Three-dimensional numerical study of natural convective heat transfer of liquid in a cubic enclosure | |
Fontana et al. | The influence of baffles on the natural convection in trapezoidal cavities | |
Kadhim et al. | Rack level study of hybrid liquid/air cooled servers: the impact of flow distribution and pumping configuration on central processing units temperature | |
Sourtiji et al. | Computational study of turbulent forced convection flow in a square cavity with ventilation ports | |
Zhu et al. | Computational analysis of closed wet cooling towers | |
Fouladi et al. | A novel approach to the data center hybrid cooling design with containment | |
Li et al. | Performance comparison between data centers with different airflow management technologies | |
Hamann et al. | The impact of air flow leakage on server inlet air temperature in a raised floor data center |