Mall et al., 2011 - Google Patents
Validation of implant stability: a measure of implant permanenceMall et al., 2011
View HTML- Document ID
- 15685003904859570688
- Author
- Mall N
- Dhanasekar B
- Aparna I
- Publication year
- Publication venue
- Indian Journal of Dental Research
External Links
Snippet
Implant stability is a requisite characteristic of osseointegration. Without it, long-term success cannot be achieved. Continuous monitoring in a quantitative and objective manner is important to determine the status of implant stability. Measurement of implant stability is a …
- 239000007943 implant 0 title abstract description 123
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/45—For evaluating or diagnosing the musculoskeletal system or teeth
- A61B5/4538—Evaluating a particular part of the muscoloskeletal system or a particular medical condition
- A61B5/4542—Evaluating the mouth, e.g. the jaw
- A61B5/4547—Evaluating teeth
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/48—Other medical applications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B8/00—Diagnosis using ultrasonic, sonic or infrasonic waves
- A61B8/08—Detecting organic movements or changes, e.g. tumours, cysts, swellings
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/12—Audiometering Evaluation or the auditory system, not limited to hearing capacity
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B17/00—Surgical instruments, devices or methods, e.g. tourniquets
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C19/00—Dental auxiliary appliances
- A61C19/04—Measuring instruments specially adapted for dentistry
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C3/00—Dental tools or instruments
- A61C3/02—Tooth drilling or cutting instruments; Instruments acting like a sandblast machine
- A61C3/03—Instruments operated by vibration
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Swami et al. | Current trends to measure implant stability | |
Mall et al. | Validation of implant stability: a measure of implant permanence | |
Atsumi et al. | Methods used to assess implant stability: current status. | |
Huang et al. | Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach | |
Zix et al. | Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. | |
Huang et al. | Early detection of implant healing process using resonance frequency analysis | |
Mistry et al. | Measuring implant stability: A review of different methods | |
Gupta et al. | Resonance frequency analysis | |
Huang et al. | Assessing the implant/bone interface by using natural frequency analysis | |
Kittur et al. | Dental implant stability and its measurements to improve osseointegration at the bone-implant interface: A review | |
Vayron et al. | Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis | |
Park et al. | Implant stability—measuring devices and randomized clinical trial for ISQ value change pattern measured from two different directions by magnetic RFA | |
Dario et al. | Electronic monitoring of dental implant osseointegration | |
JP2863448B2 (en) | Tooth mobility measurement device | |
Satwalekar et al. | Clinical evaluation of osseointegration using resonance frequency analysis | |
Sachdeva et al. | Assessment of implant stability: methods and recent advances | |
Akhmedov et al. | THE EFFECTIVENESS OF DUAL PLATFORM SWITCHING BASED ON THE IMPLANT STABILITY COEFFICIENT INDEX | |
Muhamed et al. | Implant stability: methods and recent advances | |
Ramp et al. | Dynamic behavior of implants as a measure of osseointegration. | |
Kastala | Methods to measure implant stability | |
Hayashi et al. | A no‐contact vibration device for measuring implant stability | |
Wu et al. | Biomechanical effects of the implant material and implant–abutment interface in immediately loaded small-diameter implants | |
Pan et al. | A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant | |
Sharma et al. | Axis of success: Primary and secondary stability of implant | |
Zhuang et al. | Noncontact vibro-acoustic detection technique for dental osseointegration examination |