Gammon et al., 1999 - Google Patents

The historical evolution of arcing-fault models for low-voltage systems

Gammon et al., 1999

Document ID
1561682248320752320
Author
Gammon T
Matthews J
Publication year
Publication venue
1999 IEEE Industrial and Commercial Power Systems Technical Conference (Cat. No. 99CH36371)

External Links

Snippet

An arcing fault is a dangerous form of short-circuit that may have a low current magnitude. In the case of such faults, the magnitude of the current is limited by the resistance of the arc and may also be limited by the impedance of a ground path. This lower level of fault current …
Continue reading at ieeexplore.ieee.org (other versions)

Classifications

    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01HELECTRIC SWITCHES; RELAYS; SELECTORS; EMERGENCY PROTECTIVE DEVICES
    • H01H33/00High-tension or heavy-current switches with arc-extinguishing or arc-preventing means
    • H01H33/02Details
    • H01H33/04Means for extinguishing or preventing arc between current-carrying parts
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H1/00Details of emergency protective circuit arrangements
    • H02H1/0007Details of emergency protective circuit arrangements concerning the detecting means
    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01HELECTRIC SWITCHES; RELAYS; SELECTORS; EMERGENCY PROTECTIVE DEVICES
    • H01H85/00Protective devices in which the current flows through a part of fusible material and this current is interrupted by displacement of the fusible material when this current becomes excessive
    • H01H85/02Details
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H3/00Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection
    • H02H3/14Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to occurrence of voltage on parts normally at earth potential
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H7/00Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
    • H02H7/22Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions for distribution gear, e.g. bus-bar systems; for switching devices
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H7/00Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
    • H02H7/26Sectionalised protection of cable or line systems, e.g. for disconnecting a section on which a short-circuit, earth fault, or arc discharge has occured
    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01HELECTRIC SWITCHES; RELAYS; SELECTORS; EMERGENCY PROTECTIVE DEVICES
    • H01H9/00Details of switching devices, not covered by groups H01H1/00 - H01H7/00
    • H01H9/30Means for extinguishing or preventing arc between current-carrying parts
    • H01H9/34Stationary parts for restricting or subdividing the arc, e.g. barrier plate
    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01HELECTRIC SWITCHES; RELAYS; SELECTORS; EMERGENCY PROTECTIVE DEVICES
    • H01H71/00Details of the protective switches or relays covered by groups H01H73/00 - H01H83/00

Similar Documents

Publication Publication Date Title
Gammon et al. The historical evolution of arcing-fault models for low-voltage systems
Hewitson et al. Practical power system protection
Smeets et al. Switching in electrical transmission and distribution systems
Doughty et al. The use of low voltage current limiting fuses to reduce arc flash energy
Parise et al. Unprotected faults of electrical and extension cords in AC and DC systems
Gammon et al. Instantaneous arcing-fault models developed for building system analysis
Short Arc-flash analysis approaches for medium-voltage distribution
Gammon et al. Arcing-fault models for low-voltage power systems
Mardegan et al. The experience acquired sizing snubbers to mitigate switching transients in industrial power systems
Gammon et al. Conventional and recommended arc power and energy calculations and arc damage assessment
Zamanan et al. Modelling arcing high impedances faults in relation to the physical processes in the electric arc
Catlett et al. Novel approach to arc flash mitigation for low-voltage equipment
Swindler et al. Transient recovery voltage considerations in the application of medium-voltage circuit breakers
Brauner et al. Voltage dips and sensitivity of consumers in low voltage networks
Varetsky et al. Study of transient overvoltages on CSI adjustable speed drives under arcing SLGF in the industrial cable grid
Liao et al. A novel post-arc current measuring equipment based on vacuum arc commutation and arc blow
Parsons et al. Enhancing worker and equipment protection through passive arc-fault mitigation
Medora et al. Arcing faults in low and medium voltage electrical systems-Why do they persist?
Fulchiron Protection of MV/LV substation transformers
Razi-Kazemi et al. Investigation of aging procedure of vacuum circuit breakers used in wind farms
Gammon Improved arcing-fault current models for low-voltage power systems (< 1 kV)
Malmedal et al. Arcing fault current and the criteria for setting ground fault relays in solidly-grounded low voltage systems
Shirkovets et al. Transient processes at single phase-to-ground faults in combined grounded networks
Lovrenčić et al. Computer aided arc flash risk assessment according to IEEE and DGUV Standards
Gammon et al. The application of a current-dependent arc model to arcing at a main distribution panel, a sub-panel and a branch circuit