Kılıçarslan et al., 2013 - Google Patents
Evaluation of retention of cemented laser-sintered crowns on unmodified straight narrow implant abutments.Kılıçarslan et al., 2013
- Document ID
- 12183058616045866378
- Author
- Kılıçarslan M
- Özkan P
- Publication year
- Publication venue
- International Journal of Oral & Maxillofacial Implants
External Links
Snippet
Purpose: A common problem with cemented crowns is inadequate retention at the crown- abutment interface. The aim of this study was to compare the retention of new laser-sintered cobalt-chromium alloy crowns to the retention of cobalt-chromium alloy crowns fabricated …
- 230000014759 maintenance of location 0 title abstract description 30
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C13/00—Dental prostheses; Making same
- A61C13/0003—Making bridge-work, inlays, implants or the like
- A61C13/0022—Blanks or green, unfinished dental restoration parts
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C13/00—Dental prostheses; Making same
- A61C13/0003—Making bridge-work, inlays, implants or the like
- A61C13/0004—Computer-assisted sizing or machining of dental prostheses
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K6/00—Preparations for dentistry
- A61K6/007—Preparations for dentistry characterized by the presence of inorganic additives
- A61K6/0073—Fillers
- A61K6/0091—Glass
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K6/00—Preparations for dentistry
- A61K6/02—Use of preparations for artificial teeth, for filling or for capping teeth
- A61K6/0205—Ceramics
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C8/00—Means to be fixed to the jaw-bone for consolidating natural teeth or for fixing dental prostheses thereon; Dental implants; Implanting tools
- A61C8/0048—Connecting the upper structure to the implant, e.g. bridging bars
- A61C8/005—Connecting devices for joining an upper structure with an implant member, e.g. spacers
- A61C8/0069—Connecting devices for joining an upper structure with an implant member, e.g. spacers tapered or conical connection
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C19/00—Dental auxiliary appliances
- A61C19/04—Measuring instruments specially adapted for dentistry
- A61C19/05—Measuring instruments specially adapted for dentistry for determining occlusion
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C13/00—Dental prostheses; Making same
- A61C13/08—Artificial teeth; Making same
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K6/00—Preparations for dentistry
- A61K6/02—Use of preparations for artificial teeth, for filling or for capping teeth
- A61K6/027—Use of non-metallic elements or compounds thereof, e.g. carbon
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C13/00—Dental prostheses; Making same
- A61C13/12—Tools for fastening artificial teeth; Holders, clamps, or stands for artificial teeth
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K6/00—Preparations for dentistry
- A61K6/0002—Compositions characterised by physical properties
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C5/00—Filling or capping teeth
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C3/00—Dental tools or instruments
- A61C3/08—Tooth pluggers or hammers
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Tsalouchou et al. | Fatigue and fracture properties of yttria partially stabilized zirconia crown systems | |
Yin et al. | An overview of in vitro abrasive finishing & CAD/CAM of bioceramics in restorative dentistry | |
Habib et al. | Two-body wear behavior of human enamel versus monolithic zirconia, lithium disilicate, ceramometal and composite resin | |
Lee et al. | Shear bond strength of porcelain to a new millable alloy and a conventional castable alloy | |
Kim et al. | Effect of the crystallization process on the marginal and internal gaps of lithium disilicate CAD/CAM crowns | |
Rashid et al. | Advancements in all-ceramics for dental restorations and their effect on the wear of opposing dentition | |
Aboushahba et al. | Evaluation of hardness and wear of surface treated zirconia on enamel wear. An in-vitro study | |
Kılıçarslan et al. | Evaluation of retention of cemented laser-sintered crowns on unmodified straight narrow implant abutments. | |
Markarian et al. | Scanning Electron Microscopy Analysis of the Adaptation of Single-Unit Screw-Retained Computer-Aided Design/Computer-Aided Manufacture Abutments After Mechanical Cycling. | |
Rutkūnas et al. | Accuracy of fixed implant‐supported dental prostheses additively manufactured by metal, ceramic, or polymer: A systematic review | |
Badran et al. | Effect of Incisal Porcelain Veneering Thickness on the Fracture Resistance of CAD/CAM Zirconia All‐Ceramic Anterior Crowns | |
Heydecke et al. | Material characteristics of a novel shrinkage-free ZrSiO4 ceramic for the fabrication of posterior crowns | |
Kokubo et al. | Retention of zirconia copings on zirconia implant abutments cemented with provisional luting agents | |
Winter et al. | The flexural strength of CAD/CAM polymer crowns and the effect of artificial ageing on the fracture resistance of CAD/CAM polymer and ceramic single crowns | |
Filokyprou et al. | Effect of different surface treatments on the retention force of additively manufactured interim implant‐supported crowns | |
Kiliçarslan et al. | Comparison of internal fit between implant abutments and cast metal crowns vs laser-sintered crowns | |
Manoharan et al. | Comparative analysis of fatigue resistance, fracture strength, and fracture patterns in ceramic crowns with zirconia and direct metal laser-sintered cores-An in vitro study | |
Karl | In vitro studies on CAD/CAM restorations fabricated with Procera technology: An overview. | |
Pinheiro Tannure et al. | Wear at the Implant-Abutment Interface of Zirconia Abutments Manufactured by Three CAD/CAM Systems. | |
Kalsekar et al. | Comparative evaluation of retention and vertical marginal accuracy of co–cr copings fabricated using three different techniques: an in vitro study | |
Al‐Fodeh et al. | Mechanical properties of 3D‐printed resin denture teeth: an in vitro study | |
Refaat et al. | Impact of Different Wax Pattern Construction Techniques on the Marginal and Internal Fit of Celtra Press Ceramic Restoration. | |
Mahmoud et al. | Effect of aging and pre-sintering surface treatment of zirconia cores on chipping of veneered zirconia crowns | |
Kalla et al. | Effect of surface modifications on the retention of implant-supported cement-retained crowns with short abutments: An in vitro study | |
Tajziehchi et al. | Effect of the CAD-CAM and lost-wax framework fabrication techniques on the fracture strength of porcelain in metal-ceramic restorations |