tinyCurrent – an enhanced uCurrent Gold Derivative

A low cost yet professional low current measurement shunt and amplifier combination to overcome the issue of high burden voltage as seen with multimeters and to enable low current measurement by using voltage measurement devices such as oscilloscopes.

Originally designed and sold by Dave Jones on the EEVBLOG, this derivative has several enhancements specifically for measuring varying currents on today's low power devices. Switch mode voltage regulators and the varying current draw of MCUs and RF chips require the determination of the current draw over time to calculate the total power consumption of a device. A storage oscilloscope is a perfect tool for this task and widely available. That's why the tinyCurrent features a BNC connector to reduce the picked-up noise while measuring with an and oscilloscope. Another problem is the high dynamics in power draw caused by the aforementioned reasons. This is addressed by the possibility to power the device from an external source with up to 5.5 V and bridge R7 using J6 to use the whole positive VDD as maximum positive output voltage. Both measures combined lead to almost 3 times higher dynamic range.

Modifications to the original Design

Highlights

  • Added BNC output for lower noise when acquiring data with a high input impedance instruments like an oscilloscope. The effect is lower noise compared to normal banana leads. See all scope shots for comparison.
  • Added a 2-pin 1.25 mm JST ZH style male header for powering the device externally to better use the device in permanent measurement setups. Only use without battery.
  • Allow device to be fed with supply voltage of up to 5.5 V to increase the dynamic range (only when external power source us used).
  • Added header J6 which allows to install a THT resistor or bond wire to change the ratio of the voltage divider R6/ R7 to increase the dynamic range for positive currents. R6/ R7 have a ratio of 1/ 5 to allow for a max. positive output voltage of ~80% of the supply voltage.
  • "R-Variant" with reversed BNC connector optimized for attaching the device directly to an oscilloscope's input via a BNC-to-BNC adapter.

Other Differences

  • Increased width of some traces
  • Case and board shape to fit case
  • Removed test traces on PCB on all 4 corners as they are antennas
  • Slide switches with lower current rating than in original design → Tests have shown that the used switch can easily handle 5V/ 6A which should be far enough for this device
  • Shunt resistor R9 has 0.05% greater tolerance → Parts are hand selected using 7 1/2 Digit DMM with 4 wire measurement in 100 Ohm range
  • Pads for C5, C6 to fit caps on the virtual ground rails to prevent oscillation with capacitive loads
  • Some other BoM changes without negative implications

Specifications

Min/Max Current per Range
Dynamic Range In general, the dynamic range in one direction can be determined by:
VDD / 2 - 200 mV (security margin) = X mV. In case of VGND = VDD / 2.
@2.9V VDD (mean battery voltage over usage time)
nA ± 1250 nA (20 µV / nA burden voltage typical), contact resistance plays a role here. 10 µV due to the shunt resistor.
µA ± 1250 µA (10 µV / µA burden voltage)
mA ± 1250 mA (10 µV / mA burden voltage)
@5.5V VDD (from external power source)
nA ± 2550 nA (20 µV / nA burden voltage typical), contact resistance plays a role here. 10 µV due to the shunt resistor.
µA ± 2550 µA (10 µV / µA burden voltage)
mA ± 2550 mA (10 µV / mA burden voltage)
Resolution in nA Range 1000 pA on a 3.5 digit DMM
100 pA on 4.5 digit DMM
10 pA 5.5 digit DMM
Accuracy, typical < ±0.05% on µA and nA ranges
< ±0.1% on mA range
Output Offset Voltage, maximum < ±30 µV
Temperature Drift < 10 ppm / degC (µA / nA)
< 15 ppm / degC (mA)
Noise < -90 dBV
THD < -60 dB
Bandwidth (-3 dB) 300 kHz
Power Supply CR2032 Lithium coin cell or max 5.5 V through connector J5
Battery Life >50 hours (battery good LED ensures accurate measurement when LED is on). 2.65 V cutout voltage.
Certifications CE
Materials RoHS, REACH

Similar to the original uCurrent Gold specs.

Maximum Ratings

  • Maximum supply voltage: 5.5 V
  • Maximum current through input ports: 5 A

In order to keep the burden voltage low, this device has no OVERLOAD PROTECTION. That means NO FUSES. Care is required in using the unit to prevent damage.

Schematics and PCB Design

All source files are available on Github. The schematics and PCB layout are in Altium Designer format.

Kit Contents

  • tinyCurrent PCB and case plus 4 screws
  • no battery, you need a CR2032 coin cell battery

Usage

  1. If you supply power via J5, make sure the noise level is lower than the expected output voltage. Too much noise on the supply voltage will render any measurement useless. Usually primary cells (batteries) are the best choice for this.
  2. Connect the device under test in loop on the low side so that the current flow is from + to -.
  3. Connect a suitable voltage measurement device such as a DMM or an Oscilloscope on the output side.
  4. Turn on the device and read the current on the voltage measurement device in the mV range as if it were mA/µA/nA.

Where to buy?

Pick it up ready to use from the n-fuse website.

Licenses

Circuit Schematics

The circuit schematics of this project are made available under the CC-BY-SA license.

Hardware Design

Open source hardware.

Miscellenious

Data sheets, Altium libraries, 3D Models are subject to vendor specific licensing.

Releases

No releases published

Packages

No packages published

Languages

  • HTML 100.0%