OPC UA client module allowing to read and write attributes from/to an OPC server

License

Notifications You must be signed in to change notification settings

viam-soleng/opc-ua-client

Repository files navigation

OPC UA Client modular resource

This module implements an OPC UA client using the Viam sensor api. It allows you to connect to an OPC UA server and read/write its attributes. The module is work in progress and additional features are planned to be implemented. As always, please provide feedback and suggestions wherever applicable!

Requirements

The module doesn't have any specific requirements. If you need support for another platform, let us know.

Build and run

To use this module, follow the instructions to add a module from the Viam Registry and select the viam-soleng:opc-ua:opcsensor model from the opc-ua-client module.

If you plan to modify and build it for yourself, look into check out the Makefile and have a look at Create Viam Modules.

Configure your OPC UA sensor

Note

Before configuring your sensor you must create a machine.

Navigate to the Config tab of your machine's page in the Viam app. Click on the Components subtab and click Create component. Select the component type, then select the opcsensor model provided by viam-soleng. Click Add module, then enter a name for your sensor and click Create.

On the new component panel, copy and paste the following attribute template into your sensor’s Attributes box and adjust them according to your environment:

{
  "nodeids": [
    "ns=2;i=3",
    "ns=2;i=2"
  ],
  "endpoint": "opc.tcp:https://0.0.0.0:4840/freeopcua/server/"
}

Note

For more information, see Configure a Machine.

Attributes

The following attributes are available for <INSERT API NAMESPACE>:<INSERT API NAME>:<INSERT MODEL> sensor's:

Name Type Inclusion Description
nodeids []string Optional List of node ids to be read
endpoint string Required The opc ua server address and port

Example configuration

{
  "nodeids": [
    "ns=2;i=3",
    "ns=2;i=2"
  ],
  "endpoint": "opc.tcp:https://0.0.0.0:4840/freeopcua/server/"
}

Write Attributes

The OPC UA client module allows you to set nodes to certain values by using the following parameters

{
  "write":{
    "ns=2;i=2":100,
    "ns=2;i=3":0.1
  }
}

The result will provide a list of values where 0 means succesful.

Next steps

Let us know any issues / limitations important to you and your project! Simply create an issue and we will get back to you. We also welcome pull requests which we will review and consider merging!

Troubleshooting

Current Known Limitations:

  • No authentication
  • Only reading of attributes is suppported

Features Planned

  • Write attributes
  • Authentication