Tracing Realism: A-Fib & A-Flutter #189
Labels
Comments
Atrial fibrillation isoelectric drawing updated to:
Overall, a huge improvement in clinical realism for atrial fibrillation's isoelectric drawing! |
tanjera
added a commit
that referenced
this issue
Jun 11, 2023
- Atrial fibrillation ECG drawing improved (#189) - Tracing Replace() function expanded to ReplaceAtOver() - Allows splices to replace once they supercede existing Y-values - Fixes unrealistic drops on tracing replacement (closes #190) - *Not* implemented in IABP tracings (ABP, balloon) d/t important deflections! - Implemented DampenAmplitude_DiastolicFillTime() - If Actual HR > Set HR, Lerp's a dampened amplitude - Uses i - 2 Actual HR (from PhysiologyEvents) d/t electromechanical delay - i - 1 (Last()) is data used for forthcoming pulsatile beat!
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Needs realistic update to tracing algorithms for atrial fibrillation and atrial flutter. Current tracings have unrealistic outcomes.
The text was updated successfully, but these errors were encountered: