Skip to content
/ alarmo Public
forked from nielsfaber/alarmo

Easy to use alarm system integration for Home Assistant

Notifications You must be signed in to change notification settings

sliann/alarmo

Β 
Β 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

Β 
Β 
Β 
Β 
Β 
Β 
Β 
Β 
Β 
Β 
Β 
Β 
Β 

Repository files navigation

Alarmo

hacs_badge

This is an alarm system integration for Home Assistant. It provides a user interface for setting up your own alarm system completely from the browser.

Introduction

This is an integration for the alarm_control_panel domain in HA. It allows to combine existing sensors for creating a security system for your house. The integration is comparable with the Manual Alarm in HA, but also has some additional features that makes it easier to use.

Alarmo consists of 3 parts:

  • Alarmo component: a custom component for HA that controls the states of the alarm panel entities in HA.
  • Alarmo panel: a GUI for configuring the settings of your alarm (sensors, delays, actions etc.)
  • Alarmo card: a custom card for arming / disarming the alarm.

Features

  • Fully compatible with Home Assistant and the Alarm Panel Card.
  • Has an integrated panel for complete management via UI (no YAML required).
  • No restarts required when making changes.
  • Can set up to 4 arm modes (armed_away, armed_home, armed_night, armed_custom_bypass), each with configurable delays and security perimeter.
  • Supports configuring your existing HA entities as security sensors. These sensors will be watched automatically.
  • Allows setting up multiple users with individual pincode and permission levels.
  • Will restore its previous state after restart of HA.
  • Built-in actions: receive push notifications when anything changes in the alarm, activate a siren when the alarm is triggered, etc.
  • Supports splitting up your house security system into multiple areas which can be armed independently.

Preview

Installation

Click to show installation instructions
  1. Install files:
    • Using HACS:
      In the HACS panel, go to integrations and click the big orange '+' button. Search for 'Alarmo' and click \'Install this repository in HACS'.
    • Manually:
      Download the [latest release](https://github.com/nielsfaber/alarmo/releases) as a zip file and extract it into the `custom_components` folder in your HA installation.
  2. Restart HA to load the integration into HA.
  3. Go to Configuration -> Integrations and click the big orange '+' button. Look for Alarmo and click to add it.
  4. The Alarmo integration is ready for use. You can find the configuration panel in the menu on the left.

Updating

Click to show updating instructions
  1. Update the files:
    • Using HACS:
      In the HACS panel, there should be an notification when a new version is available. Follow the instructions within HACS to update the installation files.
    • Manually:
      Download the latest release as a zip file and extract it into the custom_components folder in your HA installation, overwriting the previous installation.
  2. Restart HA to load the changes.
  3. (Optional) Verify the version number.
    • Verify version of the backend:
      In HA, go to Configuration -> Integrations. In the Alarmo card, you should see a link with '1 device', click it. In the table click the 'Alarmo' device, and you should see the Device info. The 'firmware version' represents the installed version number.
    • Verify version of the frontend:
      In the Alarmo configuration panel, the version number is displayed in the top right. If the version does not match with the backend version, your browser has an outdated version stored in the cache.
      To clear the cache, you should do a force refresh of your browser.

Uninstalling

Click to show uninstall instructions
  1. Remove Alarmo from HA:
    In HA go to Configuration -> Integrations. In the Alarmo card, click the button with the 3 dots, and click 'Delete'.
  2. Remove the files:
    • When installed with HACS:
      In the HACS panel go to integrations and look for Alarmo. Click the button with the 3 dots and click 'Uninstall'.
    • When installed manually:
      In the custom_components directory, remove the 'alarmo' folder.
  3. Restart HA to make all traces of the component dissapear.

Usage

Alarm functionality

The following diagram describes the operational states of the alarm and provides a simplified overview of the functionality.

Arm modes

The alarm can be activated (armed) in a certain mode. This mode defines a certain set of sensors and represents the security zone (or perimeter).

The following modes are supported:

  • Armed away
  • Armed night
  • Armed home
  • Armed custom bypass (let's just call it armed custom from now on)

In the tab general you can find the settings for each mode. There are flip switches to enable/disable modes.

Alarmo entity

After installing Alarmo the entity alarm_control_panel.alarmo shall be added to HA. You can use this entity together with the Alarm panel card, or in conjuction with automations to automatically arm/disarm the alarm.

States

The Alarmo entity follows the state definitions as defined by HA:

State Description
disarmed The alarm is disabled/off.
arming The alarm is arming.
After the leave delay has expired, the alarm will be armed.
armed_away The alarm is armed in away mode.
armed_home The alarm is armed in home mode.
armed_night The alarm is armed in night mode.
armed_custom_bypass The alarm is armed in custom mode.
pending The alarm is pending.
After the entry delay has expired, the alarm will be triggered.
triggered The alarm is triggered.
unavailable
unknown
Something is wrong.
Check the logs for more information.

Attributes

The Alarmo entity defines the following attributes:

Attribute Default value Example value when set Description
arm_mode null armed_away The current active arm mode.
Defined in all states except disarmed.
changed_by null Niels User who last armed or disarmed the alarm.
Detected from the entered code.
Cleared when alarm is armed or disarmed without a code.
open_sensors null {binary_sensor.backdoor: on} Dictionary of sensors with their entity-ID + state, that caused the alarm to change state.
Set when arming attempt failed (due to one or more sensors).
Set when alarm is triggered (only first sensor that caused the triggering is stored).
bypassed_sensors null [binary_sensor.backdoor] List of sensors that are temporarily excluded from the alarm, due to arming in force.

Commands

The Alarmo entities support the following commands:

Command Description Conditions
ARM_AWAY Arm the alarm in mode armed_away. - The entity has the mode away enabled.
- The current alarm state is disarmed, armed_home, armed_night, or armed_custom_bypass.
ARM_HOME Arm the alarm in mode armed_home. - The entity has the mode home enabled.
- The current alarm state is disarmed, armed_away, armed_night, or armed_custom_bypass.
ARM_NIGHT Arm the alarm in mode armed_night. - The entity has the mode night enabled.
- The current alarm state is disarmed, armed_away, armed_home, or armed_custom_bypass.
ARM_CUSTOM_BYPASS Arm the alarm in mode armed_custom_bypass. - The entity has the mode custom enabled.
- The current alarm state is disarmed, armed_away, armed_home, or armed_night.
DISARM Disarm the alarm. - The current alarm state is not disarmed

Areas

An area is a physical compartment of your house, such as a garage, 1st floor of the house, garden, etc. Alarmo will create an alarm_control_panel entity for each area which can be armed and disarmed independently. An area has its own set of sensors and can have dedicated configuration for arm modes, exit/entry times and automations.

In the general tab of the Alarmo configuration UI, there is a card showing the areas in your setup. You can add additional areas, as well as rename or remove existing areas. Alarmo requires at least 1 area to be set up to be functional.

The name of an area defines the entity ID as well. The entity will be instantly renamed after saving.

Warning: renaming an area changes the entity ID, which might break your Lovelace cards and automations outside of Alarmo, so treat it with care.

Alarm Master

Alarmo has the option for enabling an alarm master. The option appears in the general tab in general settings if you have multiple areas defined.

The alarm master is meant for operating your areas synchronously. An extra alarm_control_panel entity is created for the master, which watches the state of the areas for and mirrors its own state with that.

States

The Alarm Master will watch the states of the area entities and updates its own state accordingly.

The following table shows the rules which are implemented to determine the the master alarm state (in order of priority):

Condition Master Alarm state
One or more areas have state triggered triggered
One or more areas have state pending pending
One or more areas have state arming, others have state armed_away, armed_home, armed_night or armed_custom_bypass arming
All areas have state armed_away armed_away
All areas have state armed_home armed_home
All areas have state armed_night armed_night
All areas have state armed_custom_bypass armed_custom_bypass
All areas have state disarmed disarmed
Otherwise (previous state is kept)

Notes:

  • The Alarm Master cannot determine its state if some are disarmed while others are armed. If the Alarm Master is used for arming/disarming the alarm, this condition should not occur.
  • If the areas are independently operated, the user is reponsible to maintain synchronism between the areas. If independent operation is desired, usage of the Master Alarm is not recommended.
Commands

Arming / disarming the master will cause the action to be propagated to all areas.

If the arming of an area fails (due to blocking sensors), the arming procedure will be aborted and all areas are disarmed.

The available arm modes for the Master Alarm are determined from the areas. Only arm modes which are in common for all areas are available for the Master Alarm.

Sensor configuration

Currently Alarmo supports sensors of type binary_sensor. Alarmo will check the device class of each sensor, and only supports sensors that are related to security.

Available sensors should show up automatically in the sensors tab in the Add sensors card. Simply check the sensors that you wish to include in the alarm, and click 'add to alarm'. Review the configuration for each sensor in the sensors card.

Sensor types

The sensor configuration in the Alarmo panel allows defining a type for each sensor entity.

Setting a type for a sensor has the benefit that the appropriate configuration is automatically set. HA defines device classes for binary sensors. When assigning sensors to Alarmo, the type of the sensor is automatically determined based on this property (if it is defined).

Note that assigning a sensor type is not mandatory, and all configuration settings can also be set manually. It is also possible to deviate from the predefined configuration after setting a type.

The following table defines the sensor types and the predefined configuration:

Type Device classes Arm modes Always on Immediate Arm after closing Allow open
Door door, garage_door, lock. opening Armed Away, Armed Home, Armed Night No No Yes No
Window window Armed Away, Armed Home, Armed Night No Yes No No
Motion motion, moving, occupancy, presence Armed Away No No No Yes
Tamper sound, opening, vibration Armed Away, Armed Home, Armed Night No Yes No No
Environmental gas, heat, moisture, smoke, safety N/A Yes Yes No No

Immediate

When the alarm is armed with an immediate sensor, this sensor will trigger the alarm directly instead of waiting for the (optional) entry delay.

An immediate sensor must be closed before you can enable the alarm. It is not allowed to be open while you are leaving the house. In other words, the exit delay is not applicable to immediate sensors.

Example of use cases: in mode armed away you would normally leave and enter the house via a door. If a window is opened when the alarm is armed, this means bad news. The siren should be enabled ASAP.

Always on

When marking a sensor as always on, it will always be able to trigger the alarm, even when the alarm is disarmed. The triggering occurs as soon as the sensor is activated and entry delays will be ignored.

This functionality is intended for safety sensors, such as fire detectors.

Allow open while arming

The allow open while arming property allows a sensor to be in the active state, while (and after) the alarm is armed. Setting this property is not the same as bypassing a sensor, since as soon as the sensor returns to the inactive state, it is capable of triggering the alarm. The property only ignores the initial state of the sensor.

This property is intended for motion sensors, which have a relatively long period before they return to inactive state, after the zone is clear. By setting this property, it is possible to set a leave delay that is lower than the reset period of this sensor.

Arm after closing

The alarm on close feature is intended for entrances only. When setting this property to a door/contact sensor, Alarmo will watch this sensor while the alarm is in state arming, and determine if the user left the house.

Once the sensor state changes from open to closed, this is interpreted as the user closing the (front) door. Alarmo will skip the remaining of the exit delay, and proceed directly to the armed state. If any sensor (without the allow open while arming setting) is still open, the alarm will return to disarmed state.

Note: Alarmo uses a built-in 5 seconds delay to allow for contact bounce (the chattering of a door when pulling it shut).

Trigger when unavailable

HA defines the unavailable state for sensors for which the state is undeterminate (can be either open or closed). The unavailable state usually occurs when a battery-powered sensor loses connection to the gateway. This might be a harmless scenario (such as an empty battery) but it could also be the result of tampering of the sensor.

Since Alarmo cannot guarantee the security of your house when this occurs, it might be desirable to have the alarm trigger if this occurs. Setting the trigger when unavailable setting has the effect that the unavailable state is treated the same as the sensor being open.

Codes and users

By default, the alarm has no code and can be locked and unlocked by anyone who has access to HA. It is recommended to set a code for disarming the alarm as minumum security level.

To do so, go to the codes tab, and enable the setting 'use disarm code'.

Next, set up a user and give it a name and code. It is recommended to use the same name as your HA account, but this is not required.

Codes

A code can be a sequence of digits (4 or more) or contain a mix of letters, characters etc. Make sure to use a code that matches with the code format setting in the codes tab. This setting is detected by the alarm panel card, and will automatically show either a number pad or a text field.

Your code is stored completely secure. It is encrypted in the same way as your login credentials, and stored in the HA storage registry. When you enter a code, this will be encrypted too, and the encrypted values will be compared for a match. So it is impossible to recover your pin code. This also means that if you lose your pincode, you cannot unlock the alarm (there is no backup code!)

Administrator

The administrator setting grants access to the Alarmo configuration panel.

For using this feature, the user names in Alarmo should be matched to the account names in HA.

When a user is trying to access the Alarmo configuration panel, access is only allowed if any of the following requirements are met:

  1. The user is administrator in HA (i.e. this user can access the HA configuration)
  2. The user is not a HA administrator, but a matching user exists in Alarmo, which has the administator setting activated.

MQTT

Alarmo supports MQTT for external control of the alarm. This function is intended for third-party alarm panels (such as a touch screen in the hallway).

The MQTT support needs to be enabled before it can be used. This setting is available in tab "General".

State topic

The state topic is used to publish state changes of the alarm_control_panel entities.

The state topic is an output topic, i.e. the data is sent by Alarmo and should be received by another application (such as a wall panel display).

Default state topic (can be configured):

alarmo/state

Alarmo will send the current state of the Alarmo entity as payload (string). See here for the complete list of payloads. The payload which is sent per state can be configured if desired.

The data published on the state topic shall be sent with a retain flag. This means that the last sent payload shall be stored in the broker, and as soon as an application subscribed to the topic, the most recent data shall be available for it.

Event topic

The event topic is used for publishing additional status updates of the alarm_control_panel entities.

The event topic is an output topic, i.e. the data is sent by Alarmo and should be received by another application (such as a wall panel display).

Default event topic (can be configured):

alarmo/event

The published payloads on this topic are formatted as JSON struct, which contains the event name, and optionally some extra parameters.

The following table shows the events which are published on the event topic, together with the parameters which are sent for a certain event):

Event Description Parameters
ARM_AWAY The alarm has been armed in mode armed_away - delay: exit delay (in seconds) configured for the operation (i.e. time during which the alarm is in state arming).
ARM_HOME The alarm has been armed in mode armed_home - delay: exit delay (in seconds) configured for the operation (i.e. time during which the alarm is in state arming).
ARM_NIGHT The alarm has been armed in mode armed_night - delay: exit delay (in seconds) configured for the operation (i.e. time during which the alarm is in state arming).
ARM_CUSTOM_BYPASS The alarm has been armed in mode armed_custom_bypass - delay: exit delay (in seconds) configured for the operation (i.e. time during which the alarm is in state arming).
TRIGGER The alarm has been triggered - sensors: list of sensors (usually a single sensor) which caused the triggering of the alarm. Each list item is a struct with the entity_id and name of the sensor entity).
- delay: entry delay (in seconds) configured to postpone the triggering (i.e. time during which the alarm is in state pending).
FAILED_TO_ARM The arming was prevented or cancelled due to one or more blocking sensors. - sensors: list of sensors which prevented the arming operation. Each list item is a struct with the entity_id and name of the sensor entity).
COMMAND_NOT_ALLOWED The conditions for which the command is allowed are not met (see commands). - state: current state of the alarm entity.
- command: the command that was provided by the user.
NO_CODE_PROVIDED The command was rejected because no code was provided, while the operation requires a code.
INVALID_CODE_PROVIDED The command was rejected because a wrong code was provided, or the provided code is not allowed for the operation.

Example payload on the event topic (Consider the scenario where the alarm is armed in state armed_away and the front door is opened):

{
  "event": "TRIGGER",
  "sensors": [ # list of sensor(s) that causes the triggering
    {
      "entity_id": "binary_sensor.frontdoor",
      "name": "Front Door"
    }
  ],
  "delay": 60 # entry delay
}

Command topic

The command topic can be used for external control of Alarmo through MQTT.

The command topic is an input topic, i.e. the topic is watched by Alarmo and data should be sent by another application (such as a wall panel). The data should never be sent with retain flag, as this might give undesired behaviour when HA is restarted.

Default command topic (can be configured):

alarmo/command

If Alarmo is configured to require a pincode or password for the (arm/disarm) command, the payload must be formatted as JSON according to the following format:

{
  "command": "<my command>",
  "code": "<my pin or password>"
}

If Alarmo does not require any code for the command, the command can be sent directly as text/string value.

The supported commands can be found in commands.

If the provided payload does not have the correct format, lacks a code when it is required or contains a wrong code, the command shall be ignored. In other cases, you should see a change in the state topic.

Notes:

  • The pin or password value should always be sent as a text/string value. A numeric value is not supported. This is due to the fact that a pincode could contain leading zeros (e.g. 0012), which would be lost if sent as a number.
  • Alarmo provides the option to accept MQTT commands without requiring a code. By disabling the "Require code" setting in the MQTT configuration, the internal code check is skipped. This setting should be used with care as it may compromise the security of the alarm.
  • The command is treated as case-insensitive.

Multiple area usage

The MQTT functionality can be used in combination with a multiple area configuration.

Alarmo shall publish the state updates for the Master Alarm and the areas in dedicated state topics:

  • Master Alarm: alarmo/state
  • Area: alarmo/<area_name>/state

For targeting an arm/disarm command to a specific area, the JSON payload can be extended with the area property:

{
  "command": "<my command>",
  "code": "<my pin or password>",
  "area": "<area_name>"
}

Notes:

  • The MQTT configuration allows defining the topics for the Master Alarm only. The input topics (state/event topics) for the areas are automatically derived by inserting the area name. Example: setting state topic to my/custom/topic gives my/custom/<area_name>/topic as state topic for an area.
  • <area_name> is a slug of the name that is given to an area. This means that the name shall be in lowercase and all non-alphanumerical characters are replaced by underscores (similar to the entity_IDs in HA).
  • If no area is provided, the command is addressed to the Master Alarm. If the Master Alarm is disabled, the command is ignored.

Automations

Push notifications

Alarmo can send a push message to your phone when the alarm is armed, disarmed, triggered, something went wrong, etc. For using this, you first need to install the HA app on your iOS or Android device.

Procedure for setting up a notification

  1. In the Alarmo configuration panel, click "Actions" in the top menu.
  2. In the panel labeled "Notifications", click on "New Notification".
  3. Choose an event for which you would like to receive a push message, and choose the message content + title. Pick your device as target, and save the automation.
  4. Now Alarmo should start sending you messages πŸŽ‰

Example of the notification editor:

Wildcards

The alarmo notifications editor contains some wildcards which can be used to provide adaptive info to your push message. By adding the wildcard in a message (including the brackets) it will be automatically be replaced by the applicable text.

Wildcard Description Example Text Suitable events
{{open_sensors}} List of sensors (with their states) which are currently active Backdoor is open Failed to arm
Triggered
Entry
{{bypassed_sensors}} List of sensors which are bypassed Bedroom window Armed
{{arm_mode}} Current arming mode. Armed Away Leave
Armed
{{changed_by}} User who's code has been entered. Niels Armed
Disarmed
Actionable notifications

This function adds buttons to a push message, that can be clicked to interact with Alarmo.

Alarmo has built-in support for actionable push notification with the 'failed to arm' condition.

Example:

The 'Retry Arm' option will repeat the command that failed before. You could use it if you solved the issue in the mean time.

The 'Force Arm' option will repeat the command that failed before. The sensor/sensors that failed, shall be ignored while the alarm is armed.

Preparation (iOS devices only)

Add this to the configuration.yaml file:

ios:
  push:
    categories:
      - name: Alarm Arm Failure
        identifier: alarmo_arm_failure
        actions:
          - identifier: ALARMO_RETRY_ARM
            title: Retry Arm # feel free to change this text
            destructive: true
          - identifier: ALARMO_FORCE_ARM
            title: Force Arm # feel free to change this text
            destructive: true

Restart HA to make the configuration effective.

Set up notification with actions

In the Alarmo notifications editor, create a notification with the 'Failed to arm' event. Choose your iOS/Android device as target, set a message and title as you want.

Switch to YAML mode. Look for the part that has service_data, and extend it as follows:

 service_data:
   ... # your message and title should be here already
   data:
     actions:
       - action: ALARMO_RETRY_ARM
         title: Retry Arm # feel free to change this text
       - action: ALARMO_FORCE_ARM
         title: Force Arm # feel free to change this text

Actions

Switching a device

An important feature of a security system are the actuators (such as siren, lights, ...), which will hopefully cause a burglar threspassing your property to flee.

Alarmo features a built-in panel which can be used for switching devices on/off, depending on the state of the alarm.

Procedure for setting up an action

  1. In the Alarmo configuration panel, click "Actions" in the top menu.
  2. In the panel labeled "Actions", click on "New Action".
  3. Choose an event for which you would like to trigger a device, pick the HA entity from the list, choose whether it should be switched on, and save the automation.
  4. Now the device should automatically be triggered together with the alarm πŸŽ‰

Currently the following HA entity types are supported: switch, input_boolean, light, script.

The actions are currently limited to turning on or turning off a HA entity.

Advanced actions

In case the built-in Actions panel does not offer the flexibility you are looking for, you can set up more flexible automations in HA.

It is recommended to trigger on a state change of the alarm_control_panel entity.

Example:

trigger:
  - platform: state
    entity_id: alarm_control_panel.alarmo
    to: 'triggered'
action:
  - service: switch.turn_on
    target:
      entity_id: swich.my_siren

For the "failed to arm" condition, you can trigger on event instead:

trigger:
  - platform: event
    event_type: alarmo_failed_to_arm
condition:
  - condition: template
    value_template: '{{ trigger.event.data.reason == ''open_sensors'' }}'
action:
  - service: notify.mobile_app_my_phone
    data:
      message: >
        Could not arm because of the following problems:
        {% for entity_id in trigger.event.data.sensors %}
          - {{ state_attr(entity_id, 'friendly_name') }} is {{ states(entity_id) }}
        {% endfor %}
      title: test

Structure of the event data:

{
  "reason": "open_sensors", //other options: not_allowed, invalid_code
  "sensors": [ //only applicable if reason = open_sensors
    "binary_sensor.balcony_door"
  ],
}

Automatic arming

If you want to control the state of Alarmo through an external device (e.g. a keyfob, button panel, or phone with geofencing), you can do so by means of a HA automation.

This kind of automation cannot be made from the Alarmo "Actions" panel, you should use a HA automation instead (Configuration -> Automations).

Example of HA automation for arming with a remote button:

trigger:
  - platform: state
    entity_id: switch.my_remote
    to: 'on'
action:
  - service: alarmo.arm
    data:
      entity_id: alarm_control_panel.alarmo
      code: '1234'
      mode: away 
      skip_delay: true

Alarmo-card

The installation of Alarmo automatically adds the alarmo-card to Lovelace. This card allows you to control your alarm through the HA web interface.

The alarmo-card is similar to the Lovelace alarm panel card, but brings some extra functions:

  • A countdown timer is displayed when the alarm is in arming or pending state. It shows you how much time you have left for leaving the house / disarming the alarm.
  • A message is displayed when the arming of the alarm failed or the alarm has triggered, with an overview of the sensor(s) involved.
  • The card gives you feedback when a wrong code was entered.

Demonstration

See the alarmo-card in action:

Configuration

For setting up the card, you need to assign the correct entity to the card. All settings regarding delay times, arming modes, code settings are automatically detected.

Example YAML configuration:

type: 'custom:alarmo-card'
entity: alarm_control_panel.alarmo

Configuration using UI mode:

  1. Go to the Lovelace page where you want to add the card
  2. Click "Edit Dashboard" on the right (under the button with the 3 dots)
  • Click the "Add card" button on the bottom
  • Choose "Custom: Alarmo Card" and pick the correct entity.

Say thank you

If you want to make donation as appreciation of my work, you can buy me a coffee. Thank you!

About

Easy to use alarm system integration for Home Assistant

Resources

Stars

Watchers

Forks

Packages

No packages published

Languages

  • TypeScript 66.8%
  • Python 32.1%
  • JavaScript 1.1%