Skip to content

Releases: pulp-bio/wulpus

v1.1.0

21 Feb 09:44
cf9fd17
Compare
Choose a tag to compare

The stabilization release (v1.1.0) of the WULPUS platform includes the following changes:

Added

  • WULPUS User Manual Rev 1 (docs/wulpus_user_manual.pdf)
  • MSP430 firmware (located at fw/msp430)
  • WULPUS programmer PCBs' design files (located at hw/wulpus_programmer_pcbs).
  • Generated production files (Assembly drawings, BOM, Gerber files, Drill files, Pick&Place files) for all the PCBs.
  • Dedicated GUIs to configure the excitation/receive and measurement settings.
  • Example configurations and raw data.

Fixed

  • BLE Package loss by implementing buffering on the nRF52 MCU.
  • Multiple GUI bugs.

Changed

  • Updated the design of the acquisition and high-voltage PCBs (backward compatible with v1.0.0)
  • Improved the schematics of the PCB projects to simplify the outsourced assembly.
  • Improved the main WULPUS GUI and the example script.

Removed

  • Removed ./sw/docs folder with the old GUI guide. The information about the GUI is now available in the WULPUS user manual.

v1.0.0

03 Apr 17:20
Compare
Choose a tag to compare

Initial WULPUS release includes:

  • source code for the nRF52832 MCU of the WULPUS probe
  • source code for the nRF52840 USB dongle
  • Python code for the WULPUS Graphical User Interface
  • Altium designer source files, pdf schematics, BOM lists for
    • WULPUS Acquisition PCB
    • WULPUS High-Voltage PCB