Skip to content

ESP8266 Power Meter HAN-Port H1 reader with Vera (https://home.getvera.com/) and collectd (influxDB) integration.

License

Notifications You must be signed in to change notification settings

garyttirn/ESP8266-HAN-port

Repository files navigation

ESP8266-HAN-port

ESP8266 Power Meter HAN-Port H1 reader with Vera (https://home.getvera.com/) and collectd (influxDB) integration. Also includes BME280 sensor and WebSerial for monitoring.

Partly based on

Circuit

Essentially according to Pär Svanström's Barebone circuit. BME280 added to GPIO 4 (SDA) & 5 (SCL) Pär Svanström Barebone ESP8266

Vera Device Creation

Temperature sensor :

curl "https://VERAIP:3480/data_request?id=action&serviceId=urn:micasaverde-com:serviceId:HomeAutomationGateway1&action=CreateDevice&deviceType=urn:schemas-micasaverde-com:device:TemperatureSensor:1&internalID=&Description=WiFiTemp1&UpnpDevFilename=D_TemperatureSensor1.xml&UpnpImplFilename=&MacAddress=&RoomNum=0&Reload=1&IpAddress="

Humidity sensor :

curl "https://VERAIP:3480/data_request?id=action&serviceId=urn:micasaverde-com:serviceId:HomeAutomationGateway1&action=CreateDevice&deviceType=urn:schemas-micasaverde-com:device:HumiditySensor:1&internalID=&Description=WiFiHum1&UpnpDevFilename=D_HumiditySensor1.xml&UpnpImplFilename=&MacAddress=&RoomNum=0&Reload=1&IpAddress="

Pressure sensor :

 curl "https://VERAIP:3480/data_request?id=action&serviceId=urn:micasaverde-com:serviceId:HomeAutomationGateway1&action=CreateDevice&deviceType=urn:schemas-micasaverde-com:device:BarometerSensor:1&internalID=&Description=WiFiPressure1&UpnpDevFilename=D_BarometerSensor1.xml&UpnpImplFilename=&MacAddress=&RoomNum=0&Reload=1&IpAddress="

Power Meter :

curl "https://VERAIP:3480/data_request?id=action&serviceId=urn:micasaverde-com:serviceId:HomeAutomationGateway1&action=CreateDevice&deviceType=urn:schemas-micasaverde-com:device:PowerMeter:1&internalID=&Description=HAN&UpnpDevFilename=D_PowerMeter1.xml&UpnpImplFilename=&MacAddress=&RoomNum=0&Reload=1&IpAddress="

Other Information

The implementation has been tested on Aidon 7534 Smart Meter. BME280 showed elevated temperature readings that have compensated via hardcoded constant (-4 Degress) in the code.

SESKO SK 13-1:2022 Suositus sähköenergiamittareiden paikallista asiakasrajapintaa varten