Weidmüller: Fix uint32 and status encoding #15071

Merged
merged 1 commit into from
Jul 27, 2024
Merged

Conversation

premultiply
Copy link
Member

Fix #15064

@premultiply premultiply added the devices Specific device support label Jul 26, 2024
@andig andig merged commit 24e448e into master Jul 27, 2024
6 checks passed
@andig andig deleted the fix/weidmueller-encoding branch July 27, 2024 11:09
@tobi119
Copy link

tobi119 commented Jul 28, 2024

Danke für die schnelle Bearbeitung.

Leider ist dieser PR nur teilweise erfolgreich.
Getestet mit Nightly Version c2b29a86

Die Ladeleistung wird richtig angezeigt.
Der Status nicht:
image

image

Im Log:
image

Auch erfolgt keine Reaktion auf die Steuerung Aus / PV / Min+PV / Schnell
Ich habe in der WB den Strom auf 8A (1P) begrenzt.

@premultiply @andig
Bitte re-open das Issue

@andig
Copy link
Member

andig commented Jul 28, 2024

@premultiply sieht aus als bräuchte es ein b[1]?

@premultiply
Copy link
Member Author

Ich hab es befürchtet. Go Playground lügt einfach in solchen Dingen. Arrrg.

@premultiply
Copy link
Member Author

fixed by 568c564

@tobi119
Copy link

tobi119 commented Jul 29, 2024

Nochmals meinen Dank an @premultiply

Laden funktioniert jetzt,!

Doch enthält der Log noch Meldungen:

 [lp-1 ] DEBUG 2024/07/29 08:18:03 soc estimated: 45.00% (vehicle: 45.00%)
 [lp-1 ] DEBUG 2024/07/29 08:18:03 vehicle soc: 45%
 [lp-1 ] DEBUG 2024/07/29 08:18:03 vehicle range: 0km
 [weidmüller] TRACE 2024/07/29 08:18:03 modbus: send 03 55 00 00 00 06 ff 03 02 be 00 01
 [weidmüller] TRACE 2024/07/29 08:18:03 modbus: recv 03 55 00 00 00 05 ff 03 02 00 0a
 [lp-1 ] WARN 2024/07/29 08:18:03 charger logic error: current mismatch (got 9.46A measured, expected 8A)
 [lp-1 ] DEBUG 2024/07/29 08:18:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
 [lp-1 ] DEBUG 2024/07/29 08:18:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
 [lp-1 ] DEBUG 2024/07/29 08:18:03 pv charge current: 24.3A = 9.46A + 14.8A (-3412W @ 1p)
 [weidmüller] TRACE 2024/07/29 08:18:03 modbus: send 03 56 00 00 00 09 ff 10 02 be 00 01 02 00 50
 [weidmüller] TRACE 2024/07/29 08:18:03 modbus: recv 03 56 00 00 00 06 ff 10 02 be 00 01
 [lp-1 ] DEBUG 2024/07/29 08:18:03 max charge current: 8A

Meine Einstellungen:
image
Die WB ist derzeit noch auf 10A begrenzt.

Der vermutliche Fehler:

  Wer 80A setzt, sollte sich nicht wundern, wenn er mehr als 8A bekommt. 😊

  Zeile 170:
  wb.curr = uint16(current * 10)

.
.
Zweitens:
image

Die geladene Energie wird nicht angezeigt.
Warum Weidmüller im Register 457 (Gesamter Energieverbrauch in [Wh]) eine Null hat, werde ich dort nachfragen. Ich erwarte hier aber eigentlich die Energiesumme aller Ladevorgänge.
In Register 430 "energy last charging Wh" (uint32 in Wh) wird ein Wert für den derzeitigen Ladevorgang angegeben; vielleicht das, was hier benötigt wird.

.
.
.
Noch eine Beobachtung am Rande, die nichts mit diesem Weidmüller Charger zu tun hat,
mir aber im Log aufgefallen ist:

Beim Ausschalten des Ladevorgangs wird eine Warnung generiert:
[lp-1 ] WARN 2024/07/29 09:15:03 charger logic error: disabled but charging

Ich denke, hier wird überschnell reagiert - die Cloud benötigt einfach ihre Zeit
(es wird der tatsächliche Ladestrom -> "Jetzt Null" mit dem Fahrzeugstatus in der Cloud -> "noch ladend" verglichen

image

@premultiply
Copy link
Member Author

premultiply commented Jul 29, 2024

Warum Weidmüller im Register 457 (Gesamter Energieverbrauch in [Wh]) eine Null hat, werde ich dort nachfragen. Ich erwarte hier aber eigentlich die Energiesumme aller Ladevorgänge.

Richtig, so sollte es sein.

In Register 430 "energy last charging Wh" (uint32 in Wh) wird ein Wert für den derzeitigen Ladevorgang angegeben; vielleicht das, was hier benötigt wird.

Verwenden wir nur im Notfall, da das gerne Probleme mit zurückgesetzten Werten bei Ladeunterbrechung macht.

Beim Ausschalten des Ladevorgangs wird eine Warnung generiert:
[lp-1 ] WARN 2024/07/29 09:15:03 charger logic error: disabled but charging

Ich denke, hier wird überschnell reagiert - die Cloud benötigt einfach ihre Zeit
(es wird der tatsächliche Ladestrom -> "Jetzt Null" mit dem Fahrzeugstatus in der Cloud -> "noch ladend" verglichen

Keine Cloud beteiligt. Die Rückmeldung kommt von der Box. Was ist für interval: konfiguriert?

Screenshots sind meistens ziemlich nutzlos. Hier auch. Wichtig wäre ein ausreichend großer Logabschnitt an denen man den Zeitverlauf usw. nachvollziehen kann.

Wer 80A setzt, sollte sich nicht wundern, wenn er mehr als 8A bekommt.

Wird gefixt. Danke.
So ist das eben wenn man irgendwelche Charger blind implementiert aber nie jemand irgendwas testet oder zurückmeldet.
Daher scheint das jetzt hier der Ersttest zu sein.

@tobi119
Copy link

tobi119 commented Jul 29, 2024

Danke für die Erklärungen

Keine Cloud beteiligt. Die Rückmeldung kommt von der Box. Was ist für interval: konfiguriert?

Screenshots sind meistens ziemlich nutzlos. Hier auch. Wichtig wäre ein ausreichend großer Logabschnitt an denen man den Zeitverlauf usw. nachvollziehen kann.

interval: 30s # control cycle interval

Die WB frage ich via Modbus mit ioBroker im Sekundeninterval ab. Zwischen Meldung "Strom = 0" und Meldung "Satus = B" vergehen 63 Sekunden.

Hier ein ausführlicher Log

[lp-1 ] INFO 2024/07/29 14:48:03 start charging ->

[lp-1 ] DEBUG 2024/07/29 14:48:03 wake-up timer: stop
[weidmüller] TRACE 2024/07/29 14:48:03 modbus: send 18 5f 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:48:03 modbus: recv 18 5f 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:48:03 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:48:03 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:48:03 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:48:03 modbus: send 18 60 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:48:03 modbus: recv 18 60 00 00 00 05 ff 03 02 00 0a
[lp-1 ] DEBUG 2024/07/29 14:48:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:48:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:48:03 pv charge current: 15.6A = 9.47A + 6.08A (-1399W @ 1p)
[lp-1 ] DEBUG 2024/07/29 14:48:03 pv timer reset
[lp-1 ] DEBUG 2024/07/29 14:48:03 pv timer inactive
[weidmüller] TRACE 2024/07/29 14:48:03 modbus: send 18 61 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:48:03 modbus: recv 18 61 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:48:03 max charge current: 8A
[site ] DEBUG 2024/07/29 14:48:32 ----
[weidmüller] TRACE 2024/07/29 14:48:32 modbus: send 18 62 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:48:32 modbus: recv 18 62 00 00 00 07 ff 03 04 bb 10 00 20
[lp-1 ] DEBUG 2024/07/29 14:48:32 charge power: 2145W
[weidmüller] TRACE 2024/07/29 14:48:32 modbus: send 18 63 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:48:32 modbus: recv 18 63 00 00 00 0f ff 03 0c 25 16 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:48:32 charge currents: [9.49 0 0]A
[site ] DEBUG 2024/07/29 14:48:33 pv power: 3970W
[site ] DEBUG 2024/07/29 14:48:33 battery soc: 100%
[site ] DEBUG 2024/07/29 14:48:33 battery power: -5W
[site ] DEBUG 2024/07/29 14:48:33 grid meter: -1482W
[site ] DEBUG 2024/07/29 14:48:33 grid currents: [-5.85 4.68 -5.09]A
[site ] DEBUG 2024/07/29 14:48:33 site power: -1387W
[lp-1 ] DEBUG 2024/07/29 14:48:33 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: send 18 64 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: recv 18 64 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: send 18 65 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: recv 18 65 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:48:33 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: send 18 66 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: recv 18 66 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:48:33 charger status: C
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: send 18 67 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: recv 18 67 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:48:33 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:48:33 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:48:33 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: send 18 68 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: recv 18 68 00 00 00 05 ff 03 02 00 0a
[lp-1 ] DEBUG 2024/07/29 14:48:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:48:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:48:33 pv charge current: 15.5A = 9.49A + 6.03A (-1387W @ 1p)
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: send 18 69 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:48:33 modbus: recv 18 69 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:48:33 max charge current: 8A
[site ] DEBUG 2024/07/29 14:49:02 ----
[weidmüller] TRACE 2024/07/29 14:49:02 modbus: send 18 6a 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:49:02 modbus: recv 18 6a 00 00 00 07 ff 03 04 bf 21 00 20
[lp-1 ] DEBUG 2024/07/29 14:49:02 charge power: 2146W
[weidmüller] TRACE 2024/07/29 14:49:02 modbus: send 18 6b 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:49:02 modbus: recv 18 6b 00 00 00 0f ff 03 0c 25 bd 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:49:02 charge currents: [9.66 0 0]A
[site ] DEBUG 2024/07/29 14:49:03 pv power: 3957W
[site ] DEBUG 2024/07/29 14:49:03 battery soc: 100%
[site ] DEBUG 2024/07/29 14:49:03 battery power: 16W
[site ] DEBUG 2024/07/29 14:49:03 grid meter: -1465W
[site ] DEBUG 2024/07/29 14:49:03 grid currents: [-5.82 4.71 -5.07]A
[site ] DEBUG 2024/07/29 14:49:03 site power: -1349W
[lp-1 ] DEBUG 2024/07/29 14:49:03 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: send 18 6c 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: recv 18 6c 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: send 18 6d 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: recv 18 6d 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:49:03 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: send 18 6e 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: recv 18 6e 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:49:03 charger status: C
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: send 18 6f 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: recv 18 6f 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:49:03 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:49:03 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:49:03 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: send 18 70 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: recv 18 70 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:49:03 charger logic error: current mismatch (got 9.66A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:49:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:49:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:49:03 pv charge current: 15.5A = 9.66A + 5.87A (-1349W @ 1p)
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: send 18 71 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:49:03 modbus: recv 18 71 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:49:03 max charge current: 8A
[site ] DEBUG 2024/07/29 14:49:32 ----
[weidmüller] TRACE 2024/07/29 14:49:32 modbus: send 18 72 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:49:32 modbus: recv 18 72 00 00 00 07 ff 03 04 ae de 00 20
[lp-1 ] DEBUG 2024/07/29 14:49:32 charge power: 2142W
[weidmüller] TRACE 2024/07/29 14:49:32 modbus: send 18 73 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:49:32 modbus: recv 18 73 00 00 00 0f ff 03 0c 25 ac 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:49:32 charge currents: [9.64 0 0]A
[site ] DEBUG 2024/07/29 14:49:33 pv power: 3940W
[site ] DEBUG 2024/07/29 14:49:33 battery soc: 100%
[site ] DEBUG 2024/07/29 14:49:33 battery power: 15W
[site ] DEBUG 2024/07/29 14:49:33 grid meter: -1381W
[site ] DEBUG 2024/07/29 14:49:33 grid currents: [-5.82 4.83 -4.89]A
[site ] DEBUG 2024/07/29 14:49:33 site power: -1266W
[lp-1 ] DEBUG 2024/07/29 14:49:33 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: send 18 74 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: recv 18 74 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: send 18 75 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: recv 18 75 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:49:33 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: send 18 76 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: recv 18 76 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:49:33 charger status: C
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: send 18 77 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: recv 18 77 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:49:33 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:49:33 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:49:33 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: send 18 78 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: recv 18 78 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:49:33 charger logic error: current mismatch (got 9.64A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:49:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:49:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:49:33 pv charge current: 15.1A = 9.64A + 5.5A (-1266W @ 1p)
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: send 18 79 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:49:33 modbus: recv 18 79 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:49:33 max charge current: 8A
[site ] DEBUG 2024/07/29 14:50:02 ----
[weidmüller] TRACE 2024/07/29 14:50:02 modbus: send 18 7a 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:50:02 modbus: recv 18 7a 00 00 00 07 ff 03 04 ae de 00 20
[lp-1 ] DEBUG 2024/07/29 14:50:02 charge power: 2142W
[weidmüller] TRACE 2024/07/29 14:50:02 modbus: send 18 7b 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:50:02 modbus: recv 18 7b 00 00 00 0f ff 03 0c 25 c2 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:50:02 charge currents: [9.67 0 0]A
[site ] DEBUG 2024/07/29 14:50:03 pv power: 3929W
[site ] DEBUG 2024/07/29 14:50:03 battery soc: 100%
[site ] DEBUG 2024/07/29 14:50:03 battery power: 4W
[site ] DEBUG 2024/07/29 14:50:03 grid meter: -1345W
[site ] DEBUG 2024/07/29 14:50:03 grid currents: [-5.7 4.85 -4.89]A
[site ] DEBUG 2024/07/29 14:50:03 site power: -1241W
[lp-1 ] DEBUG 2024/07/29 14:50:03 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: send 18 7c 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: recv 18 7c 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: send 18 7d 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: recv 18 7d 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:50:03 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: send 18 7e 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: recv 18 7e 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:50:03 charger status: C
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: send 18 7f 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: recv 18 7f 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:50:03 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:50:03 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:50:03 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: send 18 80 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: recv 18 80 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:50:03 charger logic error: current mismatch (got 9.67A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:50:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:50:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:50:03 pv charge current: 15.1A = 9.67A + 5.4A (-1241W @ 1p)
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: send 18 81 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:50:03 modbus: recv 18 81 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:50:03 max charge current: 8A
[site ] DEBUG 2024/07/29 14:50:32 ----
[weidmüller] TRACE 2024/07/29 14:50:32 modbus: send 18 82 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:50:32 modbus: recv 18 82 00 00 00 07 ff 03 04 aa cd 00 20
[lp-1 ] DEBUG 2024/07/29 14:50:32 charge power: 2141W
[weidmüller] TRACE 2024/07/29 14:50:32 modbus: send 18 83 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:50:32 modbus: recv 18 83 00 00 00 0f ff 03 0c 25 a3 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:50:32 charge currents: [9.63 0 0]A
[site ] DEBUG 2024/07/29 14:50:33 pv power: 3920W
[site ] DEBUG 2024/07/29 14:50:33 battery soc: 100%
[site ] DEBUG 2024/07/29 14:50:33 battery power: 9W
[site ] DEBUG 2024/07/29 14:50:33 grid meter: -1382W
[site ] DEBUG 2024/07/29 14:50:33 grid currents: [-5.85 4.85 -4.88]A
[site ] DEBUG 2024/07/29 14:50:33 site power: -1273W
[lp-1 ] DEBUG 2024/07/29 14:50:33 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: send 18 84 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: recv 18 84 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: send 18 85 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: recv 18 85 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:50:33 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: send 18 86 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: recv 18 86 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:50:33 charger status: C
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: send 18 87 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: recv 18 87 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:50:33 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:50:33 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:50:33 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: send 18 88 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: recv 18 88 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:50:33 charger logic error: current mismatch (got 9.63A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:50:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:50:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:50:33 pv charge current: 15.2A = 9.63A + 5.54A (-1273W @ 1p)
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: send 18 89 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:50:33 modbus: recv 18 89 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:50:33 max charge current: 8A
[site ] DEBUG 2024/07/29 14:51:02 ----
[weidmüller] TRACE 2024/07/29 14:51:02 modbus: send 18 8a 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:51:02 modbus: recv 18 8a 00 00 00 07 ff 03 04 a6 bd 00 20
[lp-1 ] DEBUG 2024/07/29 14:51:02 charge power: 2140W
[weidmüller] TRACE 2024/07/29 14:51:02 modbus: send 18 8b 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:51:02 modbus: recv 18 8b 00 00 00 0f ff 03 0c 25 a6 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:51:02 charge currents: [9.64 0 0]A
[site ] DEBUG 2024/07/29 14:51:03 pv power: 3901W
[site ] DEBUG 2024/07/29 14:51:03 battery soc: 100%
[site ] DEBUG 2024/07/29 14:51:03 battery power: -0W
[site ] DEBUG 2024/07/29 14:51:03 grid meter: -1365W
[site ] DEBUG 2024/07/29 14:51:03 grid currents: [-5.83 4.86 -4.87]A
[site ] DEBUG 2024/07/29 14:51:03 site power: -1265W
[lp-1 ] DEBUG 2024/07/29 14:51:03 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: send 18 8c 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: recv 18 8c 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: send 18 8d 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: recv 18 8d 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:51:03 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: send 18 8e 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: recv 18 8e 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:51:03 charger status: C
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: send 18 8f 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: recv 18 8f 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:51:03 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:51:03 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:51:03 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: send 18 90 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: recv 18 90 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:51:03 charger logic error: current mismatch (got 9.64A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:51:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:51:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:51:03 pv charge current: 15.1A = 9.64A + 5.5A (-1265W @ 1p)
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: send 18 91 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:51:03 modbus: recv 18 91 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:51:03 max charge current: 8A
[site ] DEBUG 2024/07/29 14:51:32 ----
[weidmüller] TRACE 2024/07/29 14:51:32 modbus: send 18 92 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:51:32 modbus: recv 18 92 00 00 00 07 ff 03 04 8e 58 00 20
[lp-1 ] DEBUG 2024/07/29 14:51:32 charge power: 2134W
[weidmüller] TRACE 2024/07/29 14:51:32 modbus: send 18 93 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:51:32 modbus: recv 18 93 00 00 00 0f ff 03 0c 24 f5 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:51:32 charge currents: [9.46 0 0]A
[site ] DEBUG 2024/07/29 14:51:33 pv power: 3889W
[site ] DEBUG 2024/07/29 14:51:33 battery soc: 100%
[site ] DEBUG 2024/07/29 14:51:33 battery power: -5W
[site ] DEBUG 2024/07/29 14:51:33 grid meter: -1349W
[site ] DEBUG 2024/07/29 14:51:33 grid currents: [-5.82 4.9 -4.85]A
[site ] DEBUG 2024/07/29 14:51:33 site power: -1254W
[lp-1 ] DEBUG 2024/07/29 14:51:33 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: send 18 94 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: recv 18 94 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: send 18 95 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: recv 18 95 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:51:33 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: send 18 96 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: recv 18 96 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:51:33 charger status: C
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: send 18 97 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: recv 18 97 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:51:33 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:51:33 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:51:33 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: send 18 98 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: recv 18 98 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:51:33 charger logic error: current mismatch (got 9.46A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:51:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:51:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:51:33 pv charge current: 14.9A = 9.46A + 5.45A (-1254W @ 1p)
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: send 18 99 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:51:33 modbus: recv 18 99 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:51:33 max charge current: 8A
[site ] DEBUG 2024/07/29 14:52:02 ----
[weidmüller] TRACE 2024/07/29 14:52:02 modbus: send 18 9a 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:52:02 modbus: recv 18 9a 00 00 00 07 ff 03 04 aa cd 00 20
[lp-1 ] DEBUG 2024/07/29 14:52:02 charge power: 2141W
[weidmüller] TRACE 2024/07/29 14:52:02 modbus: send 18 9b 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:52:02 modbus: recv 18 9b 00 00 00 0f ff 03 0c 25 2b 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:52:02 charge currents: [9.52 0 0]A
[site ] DEBUG 2024/07/29 14:52:03 pv power: 3876W
[site ] DEBUG 2024/07/29 14:52:03 battery soc: 100%
[site ] DEBUG 2024/07/29 14:52:03 battery power: 4W
[site ] DEBUG 2024/07/29 14:52:03 grid meter: -1332W
[site ] DEBUG 2024/07/29 14:52:03 grid currents: [-5.77 4.91 -4.84]A
[site ] DEBUG 2024/07/29 14:52:03 site power: -1228W
[lp-1 ] DEBUG 2024/07/29 14:52:03 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: send 18 9c 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: recv 18 9c 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: send 18 9d 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: recv 18 9d 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:52:03 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: send 18 9e 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: recv 18 9e 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:52:03 charger status: C
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: send 18 9f 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: recv 18 9f 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:52:03 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:52:03 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:52:03 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: send 18 a0 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: recv 18 a0 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:52:03 charger logic error: current mismatch (got 9.52A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:52:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:52:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:52:03 pv charge current: 14.9A = 9.52A + 5.34A (-1228W @ 1p)
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: send 18 a1 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:52:03 modbus: recv 18 a1 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:52:03 max charge current: 8A
[site ] DEBUG 2024/07/29 14:52:32 ----
[weidmüller] TRACE 2024/07/29 14:52:32 modbus: send 18 a2 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:52:32 modbus: recv 18 a2 00 00 00 07 ff 03 04 a2 ac 00 20
[lp-1 ] DEBUG 2024/07/29 14:52:32 charge power: 2139W
[weidmüller] TRACE 2024/07/29 14:52:32 modbus: send 18 a3 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:52:32 modbus: recv 18 a3 00 00 00 0f ff 03 0c 24 f5 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:52:32 charge currents: [9.46 0 0]A
[site ] DEBUG 2024/07/29 14:52:33 pv power: 3863W
[site ] DEBUG 2024/07/29 14:52:33 battery soc: 100%
[site ] DEBUG 2024/07/29 14:52:33 battery power: -5W
[site ] DEBUG 2024/07/29 14:52:33 grid meter: -1322W
[site ] DEBUG 2024/07/29 14:52:33 grid currents: [-5.75 4.91 -4.83]A
[site ] DEBUG 2024/07/29 14:52:33 site power: -1227W
[lp-1 ] DEBUG 2024/07/29 14:52:33 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: send 18 a4 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: recv 18 a4 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: send 18 a5 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: recv 18 a5 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:52:33 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: send 18 a6 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: recv 18 a6 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:52:33 charger status: C
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: send 18 a7 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: recv 18 a7 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:52:33 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:52:33 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:52:33 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: send 18 a8 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: recv 18 a8 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:52:33 charger logic error: current mismatch (got 9.46A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:52:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:52:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:52:33 pv charge current: 14.8A = 9.46A + 5.34A (-1227W @ 1p)
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: send 18 a9 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:52:33 modbus: recv 18 a9 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:52:33 max charge current: 8A
[site ] DEBUG 2024/07/29 14:53:02 ----
[weidmüller] TRACE 2024/07/29 14:53:02 modbus: send 18 aa 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:53:02 modbus: recv 18 aa 00 00 00 07 ff 03 04 a2 ac 00 20
[lp-1 ] DEBUG 2024/07/29 14:53:02 charge power: 2139W
[weidmüller] TRACE 2024/07/29 14:53:02 modbus: send 18 ab 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:53:02 modbus: recv 18 ab 00 00 00 0f ff 03 0c 25 13 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:53:02 charge currents: [9.49 0 0]A
[site ] DEBUG 2024/07/29 14:53:03 pv power: 3848W
[site ] DEBUG 2024/07/29 14:53:03 battery soc: 100%
[site ] DEBUG 2024/07/29 14:53:03 battery power: 6W
[site ] DEBUG 2024/07/29 14:53:03 grid meter: -1303W
[site ] DEBUG 2024/07/29 14:53:03 grid currents: [-5.69 4.92 -4.82]A
[site ] DEBUG 2024/07/29 14:53:03 site power: -1197W
[lp-1 ] DEBUG 2024/07/29 14:53:03 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: send 18 ac 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: recv 18 ac 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: send 18 ad 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: recv 18 ad 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:53:03 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: send 18 ae 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: recv 18 ae 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:53:03 charger status: C
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: send 18 af 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: recv 18 af 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:53:03 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:53:03 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:53:03 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: send 18 b0 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: recv 18 b0 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:53:03 charger logic error: current mismatch (got 9.49A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:53:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:53:03 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:53:03 pv charge current: 14.7A = 9.49A + 5.21A (-1197W @ 1p)
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: send 18 b1 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:53:03 modbus: recv 18 b1 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:53:03 max charge current: 8A
[site ] DEBUG 2024/07/29 14:53:32 ----
[weidmüller] TRACE 2024/07/29 14:53:32 modbus: send 18 b2 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:53:32 modbus: recv 18 b2 00 00 00 07 ff 03 04 b2 ef 00 20
[lp-1 ] DEBUG 2024/07/29 14:53:32 charge power: 2143W
[weidmüller] TRACE 2024/07/29 14:53:32 modbus: send 18 b3 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:53:32 modbus: recv 18 b3 00 00 00 0f ff 03 0c 25 dc 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:53:32 charge currents: [9.69 0 0]A
[site ] DEBUG 2024/07/29 14:53:33 pv power: 3835W
[site ] DEBUG 2024/07/29 14:53:33 battery soc: 100%
[site ] DEBUG 2024/07/29 14:53:33 battery power: 25W
[site ] DEBUG 2024/07/29 14:53:33 grid meter: -1296W
[site ] DEBUG 2024/07/29 14:53:33 grid currents: [-5.7 4.95 -4.8]A
[site ] DEBUG 2024/07/29 14:53:33 site power: -1171W
[lp-1 ] DEBUG 2024/07/29 14:53:33 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: send 18 b4 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: recv 18 b4 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: send 18 b5 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: recv 18 b5 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:53:33 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: send 18 b6 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: recv 18 b6 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:53:33 charger status: C
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: send 18 b7 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: recv 18 b7 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:53:33 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:53:33 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:53:33 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: send 18 b8 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: recv 18 b8 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:53:33 charger logic error: current mismatch (got 9.69A measured, expected 8A)
[lp-1 ] DEBUG 2024/07/29 14:53:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:53:33 !! active phases: 1p = min(1p measured 1p vehicle 1p physical 0p charger)
[lp-1 ] DEBUG 2024/07/29 14:53:33 pv charge current: 14.8A = 9.69A + 5.09A (-1171W @ 1p)
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: send 18 b9 00 00 00 09 ff 10 02 be 00 01 02 00 50
[weidmüller] TRACE 2024/07/29 14:53:33 modbus: recv 18 b9 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:53:33 max charge current: 8A
[lp-1 ] DEBUG 2024/07/29 14:53:44 set charge mode: off
[site ] DEBUG 2024/07/29 14:53:44 ----
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: send 18 ba 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: recv 18 ba 00 00 00 07 ff 03 04 b2 ef 00 20
[lp-1 ] DEBUG 2024/07/29 14:53:44 charge power: 2143W
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: send 18 bb 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: recv 18 bb 00 00 00 0f ff 03 0c 25 2b 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:53:44 charge currents: [9.52 0 0]A
[site ] DEBUG 2024/07/29 14:53:44 pv power: 3833W
[site ] DEBUG 2024/07/29 14:53:44 battery soc: 100%
[site ] DEBUG 2024/07/29 14:53:44 battery power: 1W
[site ] DEBUG 2024/07/29 14:53:44 grid meter: -1278W
[site ] DEBUG 2024/07/29 14:53:44 grid currents: [-5.66 4.96 -4.79]A
[site ] DEBUG 2024/07/29 14:53:44 site power: -1177W
[lp-1 ] DEBUG 2024/07/29 14:53:44 detected active phases: 1p
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: send 18 bc 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: recv 18 bc 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: send 18 bd 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: recv 18 bd 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:53:44 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: send 18 be 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: recv 18 be 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:53:44 charger status: C
[weidmüller] TRACE 2024/07/29 14:53:44 modbus: send 18 bf 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:53:45 modbus: recv 18 bf 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:53:45 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:53:45 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:53:45 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:53:45 modbus: send 18 c0 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:53:45 modbus: recv 18 c0 00 00 00 05 ff 03 02 00 0a
[lp-1 ] WARN 2024/07/29 14:53:45 charger logic error: current mismatch (got 9.52A measured, expected 8A)
[weidmüller] TRACE 2024/07/29 14:53:45 modbus: send 18 c1 00 00 00 09 ff 10 02 be 00 01 02 00 00
[weidmüller] TRACE 2024/07/29 14:53:45 modbus: recv 18 c1 00 00 00 06 ff 10 02 be 00 01
[lp-1 ] DEBUG 2024/07/29 14:53:45 charger disable
[lp-1 ] DEBUG 2024/07/29 14:53:45 wake-up timer: stop
[site ] DEBUG 2024/07/29 14:54:02 ----
[weidmüller] TRACE 2024/07/29 14:54:02 modbus: send 18 c2 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:54:02 modbus: recv 18 c2 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:54:02 charge power: 0W
[weidmüller] TRACE 2024/07/29 14:54:02 modbus: send 18 c3 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:54:02 modbus: recv 18 c3 00 00 00 0f ff 03 0c 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:54:02 charge currents: [0 0 0]A
[site ] DEBUG 2024/07/29 14:54:03 pv power: 3828W
[site ] DEBUG 2024/07/29 14:54:03 battery soc: 100%
[site ] DEBUG 2024/07/29 14:54:03 battery power: -5W
[site ] DEBUG 2024/07/29 14:54:03 grid meter: -3492W
[site ] DEBUG 2024/07/29 14:54:03 grid currents: [-5.68 -4.65 -4.79]A
[site ] DEBUG 2024/07/29 14:54:03 site power: -3397W
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: send 18 c4 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: recv 18 c4 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: send 18 c5 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: recv 18 c5 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:54:03 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: send 18 c6 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: recv 18 c6 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:54:03 charger status: C
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: send 18 c7 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: recv 18 c7 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:54:03 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:54:03 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:54:03 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: send 18 c8 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:54:03 modbus: recv 18 c8 00 00 00 05 ff 03 02 00 00
[lp-1 ] WARN 2024/07/29 14:54:03 charger logic error: disabled but charging
[site ] DEBUG 2024/07/29 14:54:32 ----
[weidmüller] TRACE 2024/07/29 14:54:32 modbus: send 18 c9 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:54:32 modbus: recv 18 c9 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:54:32 charge power: 0W
[weidmüller] TRACE 2024/07/29 14:54:32 modbus: send 18 ca 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:54:32 modbus: recv 18 ca 00 00 00 0f ff 03 0c 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:54:32 charge currents: [0 0 0]A
[site ] DEBUG 2024/07/29 14:54:33 pv power: 3818W
[site ] DEBUG 2024/07/29 14:54:33 battery soc: 100%
[site ] DEBUG 2024/07/29 14:54:33 battery power: -4W
[site ] DEBUG 2024/07/29 14:54:33 grid meter: -3482W
[site ] DEBUG 2024/07/29 14:54:33 grid currents: [-5.67 -4.64 -4.77]A
[site ] DEBUG 2024/07/29 14:54:33 site power: -3385W
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: send 18 cb 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: recv 18 cb 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: send 18 cc 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: recv 18 cc 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:54:33 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: send 18 cd 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: recv 18 cd 00 00 00 05 ff 03 02 00 43
[lp-1 ] DEBUG 2024/07/29 14:54:33 charger status: C
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: send 18 ce 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: recv 18 ce 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:54:33 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:54:33 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:54:33 vehicle range: 52km
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: send 18 cf 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:54:33 modbus: recv 18 cf 00 00 00 05 ff 03 02 00 00
[lp-1 ] WARN 2024/07/29 14:54:33 charger logic error: disabled but charging
[site ] DEBUG 2024/07/29 14:55:02 ----
[weidmüller] TRACE 2024/07/29 14:55:02 modbus: send 18 d0 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:55:02 modbus: recv 18 d0 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:55:02 charge power: 0W
[weidmüller] TRACE 2024/07/29 14:55:02 modbus: send 18 d1 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:55:02 modbus: recv 18 d1 00 00 00 0f ff 03 0c 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:55:02 charge currents: [0 0 0]A
[site ] DEBUG 2024/07/29 14:55:03 pv power: 3804W
[site ] DEBUG 2024/07/29 14:55:03 battery soc: 100%
[site ] DEBUG 2024/07/29 14:55:03 battery power: -0W
[site ] DEBUG 2024/07/29 14:55:03 grid meter: -3466W
[site ] DEBUG 2024/07/29 14:55:03 grid currents: [-5.63 -4.62 -4.76]A
[site ] DEBUG 2024/07/29 14:55:03 site power: -3366W
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: send 18 d2 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: recv 18 d2 00 00 00 07 ff 03 04 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: send 18 d3 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: recv 18 d3 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:55:03 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: send 18 d4 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: recv 18 d4 00 00 00 05 ff 03 02 00 42
[lp-1 ] DEBUG 2024/07/29 14:55:03 charger status: B
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: send 18 d5 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: recv 18 d5 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:55:03 final charge energy: 0kWh
[lp-1 ] INFO 2024/07/29 14:55:03 stop charging <-
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: send 18 d6 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: recv 18 d6 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:55:03 charge total import: 0.000kWh
[lp-1 ] DEBUG 2024/07/29 14:55:03 !! session: start=0.000 stop=0.000 chargedEnergy=0.000
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: send 18 d7 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: recv 18 d7 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:55:03 soc estimated: 88.00% (vehicle: 88.00%)
[lp-1 ] DEBUG 2024/07/29 14:55:03 vehicle soc: 88%
[lp-1 ] DEBUG 2024/07/29 14:55:03 vehicle range: 54km
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: send 18 d8 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:55:03 modbus: recv 18 d8 00 00 00 05 ff 03 02 00 00
[site ] DEBUG 2024/07/29 14:55:32 ----
[weidmüller] TRACE 2024/07/29 14:55:32 modbus: send 18 d9 00 00 00 06 ff 03 01 a2 00 02
[weidmüller] TRACE 2024/07/29 14:55:32 modbus: recv 18 d9 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:55:32 charge power: 0W
[weidmüller] TRACE 2024/07/29 14:55:32 modbus: send 18 da 00 00 00 06 ff 03 01 96 00 06
[weidmüller] TRACE 2024/07/29 14:55:32 modbus: recv 18 da 00 00 00 0f ff 03 0c 00 00 00 00 00 00 00 00 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:55:32 charge currents: [0 0 0]A
[site ] DEBUG 2024/07/29 14:55:33 pv power: 3793W
[site ] DEBUG 2024/07/29 14:55:33 battery soc: 100%
[site ] DEBUG 2024/07/29 14:55:33 battery power: 6W
[site ] DEBUG 2024/07/29 14:55:33 grid meter: -3480W
[site ] DEBUG 2024/07/29 14:55:33 grid currents: [-5.7 -4.61 -4.74]A
[site ] DEBUG 2024/07/29 14:55:33 site power: -3375W
[weidmüller] TRACE 2024/07/29 14:55:33 modbus: send 18 db 00 00 00 06 ff 03 01 c9 00 02
[weidmüller] TRACE 2024/07/29 14:55:33 modbus: recv 18 db 00 00 00 07 ff 03 04 00 00 00 00
[lp-1 ] DEBUG 2024/07/29 14:55:33 charge total import: 0.000kWh
[weidmüller] TRACE 2024/07/29 14:55:33 modbus: send 18 dc 00 00 00 06 ff 03 01 2d 00 01
[weidmüller] TRACE 2024/07/29 14:55:33 modbus: recv 18 dc 00 00 00 05 ff 03 02 00 42
[lp-1 ] DEBUG 2024/07/29 14:55:33 charger status: B
[weidmüller] TRACE 2024/07/29 14:55:33 modbus: send 18 dd 00 00 00 06 ff 03 03 e8 00 0b
[weidmüller] TRACE 2024/07/29 14:55:33 modbus: recv 18 dd 00 00 00 19 ff 03 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
[weidmüller] TRACE 2024/07/29 14:55:33 modbus: send 18 de 00 00 00 06 ff 03 02 be 00 01
[weidmüller] TRACE 2024/07/29 14:55:33 modbus: recv 18 de 00 00 00 05 ff 03 02 00 00
[site ] DEBUG 2024/07/29 14:56:02 ----

@premultiply
Copy link
Member Author

premultiply commented Jul 29, 2024

Die WB frage ich via Modbus mit ioBroker im Sekundeninterval ab. Zwischen Meldung "Strom = 0" und Meldung "Satus = B" vergehen 63 Sekunden.

Oha! 😨
Dauert das auch so lang wenn du die Box nicht anderweitig im Sekundentakt mit Abfragen beschäftigst? 😀

Ansonsten würde wohl nur helfen das Interval auf >= 63 Sekunden zu schrauben (was die ganze Sache quasi unbenutzbar macht)
oder den Hersteller zu Fragen ob das so sein soll und wenn nein wie und wann es gefixt werden kann.

@tobi119
Copy link

tobi119 commented Jul 29, 2024

Oha! 😨
Dauert das auch so lang wenn du die Box nicht anderweitig im Sekundentakt mit Abfragen beschäftigst? 😀

Ja, auch wenn ich die Abfrage der Box stoppe und die Box neu starte (zur Sicherheit), kommt die Warnung zwei mal im Log.
Das bedeutet wohl, dass sich in der zeitlichen Abfolge nichts ändert.

Ich werde den Hersteller auch hier anfragen.

@premultiply
Copy link
Member Author

Zumindest die Sache mit dem Strom ist schon mal mit c4b5f87 gefixt.

Aus der Weidmüller Doku wird man ansonsten aber auch leider nicht so richtig schlau.
Vor allem verstehe ich nicht warum angeblich die externen Stromvorgaben im Flash gespeichert werden.
Vielleicht dauert das deshalb auch so ewig lange. Wer weiss...
Oder es braucht für Enable() (= Ladefreigabe/Ladesperre) irgendein anderes Register welches sich aber auch nicht so einfach aus der Doku erschließt.

@tobi119
Copy link

tobi119 commented Jul 30, 2024

Zumindest die Sache mit dem Strom ist schon mal mit c4b5f87 gefixt.

Danke für den Fix, der Test war erfolgreich.

Oder es braucht für Enable() (= Ladefreigabe/Ladesperre) irgendein anderes Register welches sich aber auch nicht so einfach aus der Doku erschließt.

Die Anregungen habe ich aufgenommen und getestet. Mit Register 705 kann bei entsprechender Konfiguration der WB der Ladevorgang gestartet und gestoppt werden (mein Test über Modbus). Die zeitlichen Verhältnisse ändern sich aber nicht. Der car_state ändert sich erst 63 Sekunden, nachdem das Enable weggenommen wurde.

Vor allem verstehe ich nicht warum angeblich die externen Stromvorgaben im Flash gespeichert werden.