Hi all, Have two basics, one on 5.8.0m and the other on 5.5.2b
Using a dht22 on both - both have identical setup though the on on 5.8.0m shows no sensor output, not even the sensor line in console, hoping this was a misconfiguration but all looks the same .

Working Basic:
20:34:25 MQTT: tele/sonoffsingle1/STATE = {"Time":"2017-10-27T20:34:25", "Uptime":34, "Vcc":3.165, "POWER":"ON", "Wifi":{"AP":1, "SSID":"BT-OpenRelay", "RSSI":70, "APMac":"00:1D:AA:F4:85:30"}}
20:34:25 MQTT: tele/sonoffsingle1/SENSOR = {"Time":"2017-10-27T20:34:25", "DHT22-14":{"Temperature":20.1, "Humidity":54.6}, "TempUnit":"C"}

Non working Basic (5.8.0m)
00:20:24 MQT: tele/sonoffsingle2/STATE = {"Time":"1970-01-01T00:20:24", "Uptime":1, "Vcc":3.138, "POWER":"OFF", "Wifi":{"AP":2, "SSId":"Error", "RSSI":40, "APMac":"00:1A:8C:C0:E4:31"}}

notice the MQT after the time stamp, all other logs are 3 chars long - not sure if that is relevant

@arendst
Copy link
Owner

arendst commented Oct 27, 2017

Try the latest version and enable more logging with option 3.

@edit21
Copy link
Author

edit21 commented Oct 28, 2017

Thanks - will do!

@edit21
Copy link
Author

edit21 commented Oct 28, 2017

Working now as expected on new FW \o/
TYVM for the code Arendst!

@edit21 edit21 closed this as completed Oct 28, 2017
arendst added a commit that referenced this issue Oct 29, 2017
5.8.0q
 * Shrink code by 4k using command lookup tables
 * Add retry
counter to DHT11/21/22 sensors (#1082)
 * Add commands RfSync, RfLow,
RfHigh, RfHost and RfCode to allow sending custom RF codes (#1001)
arendst added a commit that referenced this issue Oct 30, 2017
5.9.0 20171030
* Rewrite code (partly) using Google C++ Style Guide
(https://google.github.io/styleguide/cppguide.html)
* Rewrite code by using command lookup tables and javascript (client
side) web page expansions
* Change HTML/CSS to enable nicer form field entry
* Change default PWM assignments for H801 RGB(CW) led controller to
support optional Color/Dimmer control
*   GPIO04 (W2)    from GPIO_PWM2 to GPIO_USER to be user configurable
for GPIO_PWM5 (second White - Warm if W1 is Cold)
*   GPIO12 (Blue)  GPIO_PWM3 no change
*   GPIO13 (Green) from GPIO_PWM4 to GPIO_PWM2
*   GPIO14 (W1)    from GPIO_PWM1 to GPIO_USER to be user configurable
for GPIO_PWM4 (first White - Cold or Warm)
*   GPIO15 (Red)   from GPIO_PWM5 to GPIO_PWM1
* Change default PWM assignments for MagicHome RGB(W) led controller to
support optional Color/Dimmer control
*   GPIO05 (Green) from GPIO_PWM4 to GPIO_PWM2
*   GPIO12 (Blue)  from GPIO_PWM5 to GPIO_PWM3
*   GPIO13 (White) GPIO_USER to be user configurable for GPIO_PWM4
(White - Cold or Warm)
*   GPIO14 (Red)   from GPIO_PWM3 to GPIO_PWM1
* Change default PWM assignment for Witty Cloud to support optional
Color/Dimmer control (#976)
*   GPIO12 (Green) from GPIO_PWM4 to GPIO_PWM2
*   GPIO13 (Blue)  from GPIO_PWM5 to GPIO_PWM3
*   GPIO15 (Red)   from GPIO_PWM3 to GPIO_PWM1
* Change when another module is selected now all GPIO user configuration
is removed
* Change command name IRRemote to IRSend (#956)
* Remove Arduino IDE version too low warning as it interferes with
platformio.ini platform = espressif8266_stage
* Fix command FullTopic entry when using serial or console interface
* Fix possible UDP syslog blocking
* Fix minimum TelePeriod of 10 seconds set by web page
* Fix command GPIOx JSON response (#897)
* Fix inverted relay power on state (#909)
* Fix compile error when DOMOTICZ_UPDATE_TIMER is not defined (#930)
* Fix alignment of web page items in some browsers (#935)
* Fix setting all saved power settings to Off when SetOption0
(SaveState) = 0 (#955)
* Fix timezone range from -12/12 to -13/13 (#968)
* Fix Southern Hemisphere TIME_STD/TIME_DST (#968)
* Fix TLS MQTT SSL fingerprint test (#970, #808)
* Fix virtual relay status message used with Color/Dimmer control (#989)
* Fix command IRSend and IRHvac case sensitive parameter regression
introduced with version 5.8.0 (#993)
* Fix pressure calculation for some BMP versions regression introduced
with version 5.8.0i (#974)
* Fix Domoticz Dimmer set to same level not powering on (#945)
* Fix Blocked Loop when erasing large flash using command reset 2
(#1002)
* Fix relay power control when light power control is also configured as
regression from 5.8.0 (#1016)
* Fix Mqtt server mDNS lookup only when MqttHost name is empty (#1026)
* Add debug information to MQTT subscribe
* Add translations to I2Cscan
* Add translation to BH1750 unit lx
* Add light scheme options (Color cycle Up, Down, Random) and moving
WS2812 schemes up by 3
* Add Domoticz counter sensor to IrReceive representing Received IR
Protocol and Data
* Add option 0 to MqttHost to allow empty Mqtt host name
* Add support for Arilux AL-LC01 RGB Led controller (#370)
* Add esp8266 de-blocking to PubSubClient library (#790)
* Add Domoticz sensors for Voltage and Current (#903)
* Add platformio OTA upload support (#928, #934)
* Add warning to webpage when USE_MINIMAL is selected (#929)
* Add smoother movement of hour hand in WS2812 led clock (#936)
* Add support for Magic Home RGBW and some Arilux Led controllers (#940)
* Add command SetOption15 0 (default) for command PWM control or
SetOption15 1 for commands Color/Dimmer control to PWM RGB(CW) leds
(#941)
* Add Domoticz counter sensor to Sonoff Bridge representing Received RF
code (#943)
* Add support for Luani HVIO board
(https://luani.de/projekte/esp8266-hvio/) (#953)
* Add PWM initialization after restart (#955)
* Add IR Receiver support. Disable in user_config.h (#956)
* Add support for inverted PWM (#960)
* Add Sea level pressure calculation and Provide command Altitude (#974)
* Add support for up to 8 relays (#995)
* Add commands RfSync, RfLow, RfHigh, RfHost and RfCode to allow sending
custom RF codes (#1001)
* Add retain to ENERGY messages controlled by command SensorRetain
(#1013)
* Add commands Color2, Color3, Color4, Width2, Width3, Width4 and
SetOption16 to set Ws2812 Clock parameters (#1019)
* Add German language file (#1022)
* Add support for connecting to MQTT brokers without userid and/or
password (#1023)
* Add support for esp8266 core v2.4.0-rc2 (#1024)
* Add commands PwmRange 1,255..1023 and PwmFrequency 1,100..4000 (#1025)
* Add Polish language file (#1044, #1047)
* Add support for KMC 70011 Power Monitoring Smart Plug (#1045)
* Add support for VEML6070 I2C Ultra Violet level sensor (#1053)
* Add light turn Off Fade (#925)
* Add IrSend command option Panasonic as IrSend {"Protocol":"Panasonic",
"Bits":16388, "Data":<Panasonic data>}
*   where 16388 is 0x4004 hexadecimal (#1014)
* Add retry counter to DHT11/21/22 sensors (#1082)
curzon01 pushed a commit to curzon01/Tasmota that referenced this issue Sep 6, 2018
5.8.0q
 * Shrink code by 4k using command lookup tables
 * Add retry
counter to DHT11/21/22 sensors (arendst#1082)
 * Add commands RfSync, RfLow,
RfHigh, RfHost and RfCode to allow sending custom RF codes (arendst#1001)
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants