Skip to content

Here you will find all the example code for extensions and tools for the pfc family

License

Notifications You must be signed in to change notification settings

WAGO/pfc-howtos

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

69 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

This repo includes all the HowTos available for PFC

Overview of existing HowTos

Name for Version Description
AccessRetainVariables FW17 Accessing retain variables using C or C++
AddPerfTool FW12 Adding perf tool
AddTRDP FW12 Adding TRDP/TCNopen
AddSQLiteCommandLineTool FW12 Install the command-Line-Tool "sqlite3"
ADI-MyKBusApplikation FW12 Demo C Application for KBUS
ADI-DALwithSerialTerminal750-652 FW20.1 Utilize serial terminal 750-652 via DAL/ADI
AutoCopySD-CardImage2InternalFlash FW12 Automaticaly copies SD card image to internal flash
BuildRustExecutables FW17 Cross-compile RUST executables
Certmonger FW20.1 Daemon monitors certificates for impending expiration
HowTo_GenerateWUPFile FW12 Generate WAGO-Upload-File
KbusModbusSlave FW14 Adding KbusModbusSlave
Mono FW14 Mono is a runtime implementation
mosquittoBroker FW12.1 Adding a Mosquitto Broker
OpenDDS FW18 Open source C++ implementation of DDS
ReadOperatingModeSwitches FW12 Reads out the switch position
Ser2Net FW13 Serial to Network Proxy
ZeroMQ FW18 High-performance asynchronous messaging library
Libkbus-register-settings FW20.1 Precompiled version of kbus-register-settings
Register-access-65x-demo FW20.1 Demo usage of the libkbus-register-settings library
AddUserOrGroup FW20 Add a user or a group in different FW-versions
SplitAdminUser FW20 Seperate admin user for codesys3 and wbm

You will find in any specific HowTo a dedicaded README.md which included a table that shows you the compatibiliy of this how to.

For example:

PFC Compatible
PFC 100
750-8100 Y
750-8101 Y
750-8102 Y
PFC 200
750-8202 Y
750-8203 Y
750-8204 Y
750-8206 Y
750-8207 Y
750-8208 Y
PFC 200 G2
750-8212 Y
750-8213 Y
750-8214 Y
750-8216 Y

Also you will find a version information that show exactly the firmware version on which this Howto was created. This means if you will find an older HowTo for a newer firmware it might require a little extra effort to transfer it to the actual firmware version. Pleasw keep in mind that some HowTos includes a precompiled package. Those could work on older versions but we recommend to recompile them within the actual firmware.

A version Information looks like this:


HowTo XY - For Version BSP2017.17.1


Inside the HowTo directory you will find for older HowTos a HowTo_XY.txt file. This file contains a setup guide and provides some extra informations.