You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Bug description
With more than 10 members connected to a single joint an error from hydrodyn is issued:
"JointID2 in the Members table does not appear in the Joints table."
To Reproduce
A jacket structure with more than 10 members connected to a single joint. In my case the interface node at top of the transition piece was connected with 13 members.
Expected behavior
Run without errors...
It's an easy fix to correct the error. Just increase the size of "ConnectionList" in Morison_Types.f90. There are 2 occurrences of the table. I.e.:
! Increased size of ConnectionList. B. Melhus 27.09.2021
! INTEGER(IntKi) , DIMENSION(1:10) :: ConnectionList !< List of Members connected etc..
INTEGER(IntKi) , DIMENSION(1:20) :: ConnectionList !< List of Members connected etc..
and:
! Increased size of ConnectionList. B. Melhus 27.09.2021
! INTEGER(IntKi) , DIMENSION(1:10) :: ConnectionList !< Indices of all the members etc...
INTEGER(IntKi) , DIMENSION(1:20) :: ConnectionList !< Indices of all the members etc..
It might be prudent to also have a check if the dimension is violated, e.g. in hydrodyn
Screenshots, if applicable
OpenFAST Version
OpenFAST-v3.0.0-dirty
Compile Info:
**************************************************************************************************
OpenFAST
Copyright (C) National Renewable Energy Laboratory
Copyright (C) Envision Energy USA LTD
This program is licensed under Apache License Version 2.0 and comes with ABSOLUTELY NO WARRANTY.
See the "LICENSE" file distributed with this software for details.
**************************************************************************************************
**System Information (please complete the following information):**
- Visual studio
**Additional context**
<Add any other context about the problem here.>
The text was updated successfully, but these errors were encountered:
Bug description
With more than 10 members connected to a single joint an error from hydrodyn is issued:
"JointID2 in the Members table does not appear in the Joints table."
To Reproduce
A jacket structure with more than 10 members connected to a single joint. In my case the interface node at top of the transition piece was connected with 13 members.
Expected behavior
Run without errors...
It's an easy fix to correct the error. Just increase the size of "ConnectionList" in Morison_Types.f90. There are 2 occurrences of the table. I.e.:
! Increased size of ConnectionList. B. Melhus 27.09.2021
! INTEGER(IntKi) , DIMENSION(1:10) :: ConnectionList !< List of Members connected etc..
INTEGER(IntKi) , DIMENSION(1:20) :: ConnectionList !< List of Members connected etc..
and:
! Increased size of ConnectionList. B. Melhus 27.09.2021
! INTEGER(IntKi) , DIMENSION(1:10) :: ConnectionList !< Indices of all the members etc...
INTEGER(IntKi) , DIMENSION(1:20) :: ConnectionList !< Indices of all the members etc..
It might be prudent to also have a check if the dimension is violated, e.g. in hydrodyn
Screenshots, if applicable
OpenFAST Version
OpenFAST-v3.0.0-dirty
Compile Info:
Execution Info:
OpenFAST input file heading:
IEA 15 MW offshore reference model jacket configuration
The text was updated successfully, but these errors were encountered: