Remove monitor op from stonith-sbd #83080

Closed
wants to merge 1 commit into from
Closed

Commits on Oct 28, 2021

  1. Remove monitor op from stonith-sbd

    I removed    op monitor interval="15" timeout="15" from stonith-sbd. 
    With multiple SBD disks, in case one disk failed, the monitor operation will detect a failure and pacemaker will try to restart stonith-sbd resource on all node and the start will fail and stonith-sbd become inactive. 
    stonith-sbd    (stonith:external/sbd): Stopped
    
    Removing above monitor operation, the system will log failure messages in logs but resource will not restart. 
    Oct 25 11:42:38 ora1 sbd[3034]:  warning: inquisitor_child: Servant /dev/disk/by-path/ip-192.168.0.10:3260-iscsi-iqn.2019-11.sbd.local:ora1-sbd-2-lun-1 is outdated (age: 4)
    Oct 25 11:42:38 ora1 sbd[3035]: /dev/disk/by-path/ip-192.168.0.10:3260-iscsi-iqn.2019-11.sbd.local:ora1-sbd-2-lun-1:    error: header_get: Unable to read header from device 5
    Oct 25 11:42:38 ora1 sbd[3035]: /dev/disk/by-path/ip-192.168.0.10:3260-iscsi-iqn.2019-11.sbd.local:ora1-sbd-2-lun-1:    error: servant_md: No longer found a valid header on /dev/disk/by-path/ip-192.168.0.10:3260-iscsi-iqn.2019-11.sbd.local:ora1-sbd-2-lun-1
    
    Also, in our HAE documentation we don't advice customer to us op monitor for stonith-sbd resource:
    https://documentation.suse.com/sle-ha/15-SP3/single-html/SLE-HA-administration/#book-administration 
    