Skip to content

AhmedAchraf2001/Vital-signs-PPG-Signal-Analysis

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

6 Commits
 
 
 
 
 
 

Repository files navigation

Vital signs: PPG Signal Analysis

Using only the driver's hands, Vital signs such as heart rate can be monitored to confirm whether he is in good condition or not to avoid accidents. And make a decision such as stopping the vechile.



Why use PPG over ECG?

PPG indirectly measures heart rate and can be measured anywhere with adequate access to skin vessels. Although not as accurate as ECG, it is worth noting that PPG is still an incredibly accurate measure of heart rate



Algorithm

Description : Systolic upslopes are detected from a signal generated with a slope sum function, which sums the magnitudes of the PPG upslopes in the previous 0.17 s. Adaptive thresholding is used to identify systolic upslopes in this signal. The 'qppgfast' implementation of this beat detector was used, after testing showed it performed similarly to the original 'qppg' implementation.

inputs

    sig : a vector of PPG values

    fs : the sampling frequency of the PPG in Hz

outputs

    peaks : indices of detected pulse peaks

    onsets : indices of detected pulse onsets


My Contribuation

My contribution was about implementation the algorithm in Python programming language.



References

A. N. Vest et al., 'An open source benchmarked toolbox for cardiovascular waveform and interval analysis,' Physiological Measurement, vol. 39, no. 10, 2018. https://doi.org/10.1088/1361-6579/aae021