PLCComS - Communication server implemented as Home Assistant addon.
Communication server provide TCP/IP connection with client device and a PLC. Communication of server with client is created by simple text oriented protocol - question/answer. Server communicates with PLS optimalized by EPSNET protocol or in case of SoftPLC by shared module.
switch:
- platform: telnet
switches:
ac_bedroom:
name: "A/C Bedroom"
resource: 192.168.1.190 #ip of PLCcomS (Home Assistant)
port: 5011 #port of PLCcomS (defined in addon config)
command_on: "SET:T_ZONES_SET[0].TOPIT_TC,1\n"
command_off: "SET:T_ZONES_SET[0].TOPIT_TC,0\n"
command_state: "GET:T_ZONES_SET[0].TOPIT_TC\r\n"
value_template: '{{ value == "GET:T_ZONES_SET[0].TOPIT_TC,1" }}'
timeout: 3
Your TECO device has to be defined in rootfs / opt / plccoms / PLCComS.ini
Is simple text oriented protocol. Every line is ended new line character (DOS [\r\n] or UNIX [\n]). For testing is possible use telnet client.
Commands:
LIST:\n - Get list of all variables in public file.
SET:<variable_name,value>\n - Set variable in PLC to requested value.
GET:<variable_name>\n - Get value of variable from PLC.
EN:[variable_name] [delta]\n - Enable variable(s) in public file and set variance delta.
DI:[variable_name] [delta]\n - Disable variable(s) in public file and set variance delta.
HIDE:<variable_name>\n - Hide variable(s) in public file.
UNHIDE:<variable_name>\n - Unhide variable(s) in public file.
GETMEM:<variable_name mem_size> - Get memory block from PLC.
GETFILE:<file_name>\n - Get file from PLC.
GETFILEINFO:<file_name>\n - Get informations about file from PLC.
WRITEFILE:<file_name>[<block_size>]=data\n - Write file into PLC or PC.
WRITEFILEINFO:<file_name>[<block_size>]=data\n - Write informations about file into PLC or PC.
GETINFO:[name]\n - Get informations about communication server.
name:
version - Version of the communication server.
version_epsnet - Version of EPSNET library.
version_ini - Version of INI parsing library.
version_plc - PLC version.
ipaddr - IP address of PLC.
epsaddr - EPSNET source address.
epsport - EPSNET communication port.
serial_device - Settings of serial line.
pubfile - The names of actual public files.
network - List of connected clients.
SETCONF:<variable_name,value>\n - Change variable listed in configuration file.
variable_name:
ipaddr - IP address of PLC.
epsaddr - EPSNET source address (1 - 126).
epsport - EPSNET communication port.
serial_device - Name of serial line.
serial_speed - Communication speed for serial line.
pubfile - Public file.
crlf - End line character (yes = DOS [\r\n], no = UNIX [\n]).
diff - Enable or disable sending DIFF messages (yes = Enabled).
variables (yes = Enabled).
HELP:\n - Display help message.
Answers for commands:
LIST:\n
LIST:test_1\n
LIST:test_2\n
LIST:\n
SET:test_1,123\n
DIFF:test_1,123\n - DIFF is send if any variables change value.
GET:test_1\n
GET:test_1,123\n
GET:test_string\n
GET:test_string,"Hello!"\n
GETFILE:https://www/LOGIN.XML\n
GETFILE:https://www/LOGIN.XML[195]=<?xml version="1.0"
encoding="windows-1250" ?>\n
<?xml-stylesheet type="text/xsl" href="login.xsl"
version="1.0"?>\n
<LOGIN>\n
<USER VALUE=""/>\n
<PASS VALUE=""/>\n
<ACER VALUE="0"/>\n
</LOGIN>\n
\n
GETFILE:https://www/LOGIN.XML[0]=\n
GETFILEINFO:https://www/LOGIN.XML\n
GETFILEINFO:https://www/LOGIN.XML[36]=195 32 59391128503405 59391128503405\n
GETINFO:\n
GETINFO:VERSION,Ver 5.9 May 9 2022 11:19:25
GETINFO:VERSION_EPSNET,Ver 3.5 May 9 2022 11:19:21
GETINFO:VERSION_INI,Ver 3.2 May 9 2022 11:19:25
GETINFO:VERSION_PLC,CP2080I B 2.7 2.1
GETINFO:IPADDR,192.168.134.176
GETINFO:EPSADDR,1
GETINFO:EPSPORT,61682
GETINFO:PUBFILE,2/2 [FIXED_Foxtrot.pub,//iFoxtrot.pub]
GETINFO:NETWORK,1/128 [127.0.0.1]
GETINFO:\n
Commands and variable names is not case sensitive. Is possible combine upper and lower chracters. Closing connection in telnet client is via ansi escape sequence ctrl+d.