PGCLS1000KW: Leroy-Somer LSA49.1L11 Stamford LVI634E Tide TPA404S5

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

PGCLS1000KW

CUMMINS Alternator Leroy-somer


: TCM1125X (Open)
Engine: LSA49.1L11 Generator
KTA38-G4 Optioanl: Stamford LVI634E Model: TCM1125XC
Electronic Governor Tide TPA404S5 (Silent)

60Hz 3 Phase Pow er Factor: Emissions


N/A
1800 r.p.m 4 W ires Cos ¢ = 0.8 Certification:

Prime Pow er Standby Pow er Rated Current


RATINGS (PRP) (LTP) (A )
Voltage (V) kW kVA kW kVA Amps
480/277 900 1125 1000 1250 1353.2
440/254 900 1125 1000 1250 1476.2
416/240 900 1125 1000 1250 1561.4
240/138 900 1125 1000 1250 2706.4
220/127 900 1125 1000 1250 2952.4

RATINGS:
All three Phase generator sets are rated at 0.8 power factor. All single-phase generator sets are rated at 0.8 or 1.0 power
factor. POWERGEN reserves the right to change the design or specifications without notice and without any
obligation or liability whatsoever.
Prime
Available continuously at variable load in lieu of Standby Pow er:
commercially purchased power for an unlimited number Emergency Standby Power in variable load applications in
of hours per year in accordance with ISO8528-1, and an accordance with ISO8528-1 in the event of a utility power
overload of 10% permitted for one hour in every twelve failure. No overload available for this service as relevant
hours of operation in accordance with ISO 3046-1. alternators are peak continuous rated at 27℃.
StandardFeatures
▲ High efficient water cooled diesel engine ▲ Radiator with cap and drain point.
▲ Brushless alternators (Class H, with AVR.) ▲ Fully guarded engine driven fa
▲ Heavy duty rubber anti-vibration mountings ▲ No MCCB
▲ 12/24V starter batteries and connecting cables ▲ Oil filter - Diesel filter - Air filter
▲ Separate engine-drive battery charging alternator ▲ Fully welded steel baseframe with lifting and
▲ Industrial silencer for open type generator sets fork-lifting facilities.
▲ Residential silencer for open type generator sets ▲ Sound proof & Weather protective enclosures for
▲ Auto start / Digital PowerGen Easycon Control Panel silent type generator sets.
▲ Wiring with IEC standard
▲ Factory Test Certificate
▲ Operation & Maintenance Manual & Diagrams
▲ Worldwide Product / Technical Support

Optional
△ Automatic Transfer Switch (ATS) △Extra air filters for time-maintenance
△ Water - fuel separator △Extra diesel filters for time-maintenance
△ Water heater for severe cold weather △Extra oil filters for time-maintenance
△ Lub-oil heater for severe cold weather △Separated standing fuel tank
△ 50℃-60℃ Radiator △Low coolant level sensor
△Dual wall fuel tank base △Full range of attachments and options available
△Fuellevel sensor for alternator
△Maintenance free battery △ACB
△Additional CE Features Selection

OverallDimensions(mm)&W eight(kg)
Open Type Silent Type

Length: Length:
4350 5890
W idth: W idth:
2100 2438
Height: Height:
2400 2591
W eight: W eight:
8900 12400
Dimension and design are subject to change without notice.

W arranty

The goods of POWERGEN System are under warranty against defects in materials and
workmanship for a period of 12 months or 1000 hours whichever comes first from the
date of delivery to the end user (except the damageable spare parts of genset caused
by incorrect man-made operation), and that the aforementioned warranty for the same
token is back up by the engine & alternator manufactures and their global distributors.
EngineSpecification 60HZ

General Performance Lubrication System


Manufacture CCEC Cummins Oil Pan Capacity(High-Low) 114-87 Litres
Engine Model KTA38-G4 Maximum Oil Temperature 121℃
Engine Type 4 Cycle, V 60°, 12 Cylinder Maximum Oil Consumption N/A
Engine Speed 1800 r.p.m Total System Capacity Including Bypass Filter 135 Litres
Base Output Power 1007kW/1350hp
Standby Power 1112kW/1490hp Fuel System
Governor Type Electronic Type Injection System Direct Injection Cummins PT
Air Intake Way Turbocharged & Aftercooled Fuel Consumption at 100% Standby power 271 Litres/hour
Displacement 37.8L Fuel Consumption at 100% Prime power 245 Litres/hour
Cylinder Bore * Stroke 159mm × 159mm Fuel Consumption at 75% Prime power 190 Litres/hour
NO. of Cylinders 12 Fuel Consumption at 50% Prime power 136 Litres/hour
Compression Ratio 13.9:1 Fuel Consumption at 25% Prime power 81 Litres/hour
Engine Idle Speed 725-775 r/min Fuel Tank Capacity
Piston Speed 9.5 m/s - Open Type Genset N/A
Intake Air Flow 1435 Litres/sec. - Silent Type Gensets N/A
Air Clearner Type Dry
Cooling System
Exhaust System Coolant Capacity - Engine Only 124 Litres
Exhaust Gas Flow 3967 Litres/sec. Standard Thermostat (Modulating) Range 82 - 93℃
Exhaust Gas Temperature 499 - 524℃ Maximum Top Tank Temperature
Maximum Back Pressure 76mm Hg - Standby Power 104℃
Exhaust Pipe Size N/A - Prime Power 100℃

Air Intake System Electric System


Recommended intake piping size N/A Electrical System Voltage 24V
Maximum Intake Air Restriction Battery Maintenance-free
- Dirty Element 635mm H2O Connecting Cables Auailable
- Clean Element 254mm H2O
Thermal
Radiated Heat to Ambient 148-163kW
Heat Rejection to Coolant 617-681kW
Heat Rejection to Exhaust 694-762kW
AlternatorSpecification
GeneralData 60HZ/1800R.P.M
Manufacture / Brand Leroy-somer Prime Output Power 1124kW/1405kVA
Model LSA49.1L11 Standby Output Power 1236kW/1545kVA
AVR Model R450 Insulation class H
Coupling / Bearing Direct / Single Bearing Voltage regulation ± 0,5 %
Phase 3 Phase Total harmonic TGH / THC <3,5%
Power Factor Cos¢ = 0.8 Wave form : NEMA = TIF - (*) < 50
Winding pitch - Code 2/3 - (N° 6) Wave form : I.E.C. = THF - (*) <2%
Drip Proof IP 23 Altitude ≤ 1000 m
Excitation AREP or PMG Overspeed 2250 min -1
POWERGEN EasyconControlSystems “LetyourGeneratoralwaysinControl”

PowerGen comprehensive Easycon range control panels are compact, versatile and easy to use.

Easycon 2.0L/H (GU601A / Deepsea DSE3110) panel is a key-start


auto control panel, it’s a basic control panel fits for generators up to
100kVA to provide basic operating parameters display and
protection.

Easycon 3.0 L/H (GU641B / Deepsea DSE7210) panel is an


auto & digital control panel, it’s an entry level control panel
which provides full power monitoring and protection facilities.
All operating parameters are with LCD display.
(Auto Main Failure Version DSE7220 also Available.)

Easycon 4.0L/H (GU620A / Deepsea DSE7310) panel is an


auto & digital & Remote control panel which includes all the
features of Easycon 3.0, and plus data communication of full
telemetry via the RS232/RS485 interfaces, CANBus is
also included.
(Auto Main Failure Version DSE7320 also Available.)

Specifications
2 Over Speed pre-alarm & shutdown - Auto Start -
. Low Oil Pressure Pre-Alarm & shutdown - Oil Pressure -
3 0 High Water Temp. Pre-alarm & shutdown - Genset Running Hours -
4 . L Volts, Current, Frequency, Rpm (Instruments)- Battery Voltage and Charging -
. 0 / Fuel Sensor as optional -
0 L H AMF Module as optional -
L / Digital Control Panel - Switch Opening as Optional -
/ H Overcurrent Pre-alarm - AMF Module as optional -
H Overcurrent Shutdown - Power Factor -
Prefix Start, Service Indicate, Fault History for Deepsea Module.-
Remote Start (Data communication of full telemetry via the RS232/RS485) -
CANBus -

Options
Easycon 5.0H (Deepsea DSE8610) panel fits for Easycon 6.0H (Deepsea DSE8620) panel fits for Single Gen
Gen-Gen automatic Synchronising and load sharing. - Mains automatic Synchronising.

Deepsea DSE7560 Synchronising Controller for Multi


gen – Mains Synchronising. This is a separate control (For details specifications of Control Panels,
unit which enables multiple Easycon 5.0 equipped Gens please consult our sale department.)
to be synchronised with the Mains supply.
CircuitBreaker
The generators are supplied together with a circuit breaker that permits a thermal protection against overloads and
magnetic protection against short-circuit.

AutomaticTransferSw itch A .T.S-4Poles

POWERGEN offers not only a changeover switch but also an


integrated mains detection and switch system for your 24 Hour Power
Protection. The system enables automatic start-up and operation of the
generating set in the event of a mains power failure, overvoltage or loss
of phase; and also mains automatic re-transfer once it come back.

ATS: Automatically transfer and re-transfer load from main power to


gen-power without operator intervention. (Both Automatic and manual
operation.)
Please consult our sales department for specifications.

ContainerizedEnclosure/Canopy (Sound-attenuated&W eatherProtective)

“Ensure a quieter life w ith our sound attenuation system.”


Features:

RobustContainerDesign SecurityandSafety
▲20ft 40ft (HC also available) ISO footprint ▲Control panel viewing window in a lockable access door
▲Container made from steel components with ▲Emergency stop button mounted on canopy exterior
durable paint system ▲Fuel fill and battery can only be reached via
▲Full bunded steel floor and steel louvres lockable access doors
▲Rugged surface - excellent corrosion & rust protection ▲Fire extinguisher
▲Long service life ▲Exhaust silencing system enclosed for operator
safety (residential silencer included)
ExcellentAccessforMaintenance ▲Excellent cooling system to avoid high water temp.,
▲Separate & Standing control cabinet at one side reliable operation under harshest conditions.
▲Walk around interior with access doors ▲(Ambient temp.upto 40-52℃ and altitudes up to 1000M)
▲Fully bounded steel floor
▲Anti-explosive light bulb Optional
△Sockets
Transportability △Floor Standing MCCB/ACB (>1250Amp)
▲ISO shipping dimensioned container △Interior Separate fuel tank volume (100–2000L/depends)
▲Lifting capability △Automatic fuel fill-in & cut off system
Quiet (Reduce Sound and V ibration) △Exterior Separate fuel tank volume
Noice Level: (No limitation, shipped by separate container.)
≤85-88dBA at 1m Pleaseconsultactualdimension&w eight&freightcost.

You might also like