SITOP
SITOP
SITOP
Catalog KT 10.1
2012
SITOP
Answers for industry.
Umschlag_Katalog_KT10_1_2012_en.indd 2 17.10.2011 17:34:35
Siemens AG 2011
Note:
Information on customer-specific power supplies is included on
our website under:
www.siemens.com/sitop
Industrial Controls IC 10
SIRIUS
E86060-K1010-A101-A2-7600
SIMATIC ST 70
Products for
Totally Integrated Automation
and Micro Automation
E86060-K4670-A101-B3-7600
SIMATIC HMI / ST 80/ST PC
PC-based Automation
Human Machine Interface Systems
PC-based Automation
E86060-K4680-A101-B8-7600
SINUMERIK & SINAMICS NC 61
Equipment for Machine Tools
E86060-K4461-A101-A3-7600
Motion Control PM 21
SIMOTION, SINAMICS S120
and Motors for
Production Machines
E86060-K4921-A101-A2-7600
Catalog CA 01 CA 01
Products for Automation and Drives
DVD: E86060-D4001-A510-C9-7600
Industry Mall
Information and Ordering Platform
in the Internet:
www.siemens.com/industrymall
Related catalogs
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Power supply SITOP
Catalog KT 10.1 2012
Supersedes:
Catalog KT 10.1 2009
Refer to the Industry Mall for current updates
of this catalog:
www.siemens.com/industrymall
The products contained in this
catalog can also be found in the
Interactive Catalog CA 01 on DVD.
Order No.:
E86060-D4001-A510-D0-7600
Please contact your local Siemens branch
Siemens AG 2011
The products and sys-
tems described in this
catalog are manufac-
tured/distributed under
application of a certified
quality management
system in accordance
with DIN EN ISO 9001
(Certified Registration
No. 1108). The certifi-
cate is recognized by all
IQNet countries.
Introduction
1
SITOP 1-phase
24 V DC, up to 2 A
2
SITOP 1-phase
24 V DC, 2.5 A
3
SITOP 1-phase
24 V DC, 4 A
4
SITOP 1-phase and 2-phase
24 V DC, 5 A
5
SITOP 1-phase and 2-phase
24 V DC, 6 A
6
SITOP 1-phase and 2-phase
24 V DC, 10 A
7
SITOP 1-phase and 2-phase
24 V DC, 12 up to 40 A
8
SITOP 3-phase
24 V DC, 5 up to 20 A
9
SITOP 3-phase
24 V DC, 30 up to 40 A
10
SITOP expansion modules
24 V DC
11
SITOP uninterruptible power supplies
DC UPS
12
SITOP
Alternative voltages
13
Accessories
14
SIPLUS power supplies
15
Technical information and
configuring notes
16
Appendix
17
Printed on paper
fromsustainably
managed forests and
controlled sources.
www.pefc.org PEFC/04-31-1267
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/2
Siemens KT 10.1 2012
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/3
Siemens KT 10.1 2012
Answers for industry.
Siemens Industry answers the challenges in the
manufacturing and the process industry as well as in
the building automation business. Our drive and automation
solutions based on Totally Integrated Automation (TIA) and
Totally Integrated Power (TIP) are employed in all kinds
of industry. In the manufacturing and the process industry.
In industrial as well as in functional buildings.
Siemens offers automation, drive, and
low-voltage switching technology as
well as industrial software from stan-
dard products up to entire industry solu-
tions. The industry software enables our
industry customers to optimize the en-
tire value chain from product design
and development through manufacture
and sales up to after-sales service. Our
electrical and mechanical components
offer integrated technologies for the en-
tire drive train from couplings to gear
units, from motors to control and drive
solutions for all engineering industries.
Our technology platform TIP offers ro-
bust solutions for power distribution.
The high quality of our products
sets industry-wide benchmarks.
High environmental aims are part of
our eco-management, and we imple-
ment these aims consistently. Right
from product design, possible effects on
the environment are examined. Hence
many of our products and systems are
RoHS compliant (Restriction of Hazard-
ous Substances). As a matter of course,
our production sites are certified ac-
cording to DIN EN ISO 14001, but to us,
environmental protection also means
most efficient utilization of valuable
resources. The best example are our
energy-efficient drives with energy sav-
ings up to 60 %.
Check out the opportunities our
automation and drive solutions provide.
And discover how you can sustainably
enhance your competitive edge with us.
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/4
Siemens KT 10.1 2012
SIMATIC IT
IO-Link
PROFIBUS PA
HART
Totally
Integrated
Automation
SIMATIC Distributed I/O
SIMATIC Controllers
Modular / PC-based
Energy Management
Asset Management
Field Level
SIMATIC Ident
Industrial Identication
Process Instrumentation
SIMATIC NET
Industrial
Communication
SIMOTION
Motion Control
SINUMERIK
Computer Numerical Control
Industrial Software for
Product Design
Production Planning
Engineering
Commissioning
Operation
Maintenance
Modernization and Upgrade
ERP Enterprise Resource Planning
MES Manufacturing Execution Systems
SIMATIC PCS 7
Process Control (DCS)
Operations Level
Management Level
Control Level
Setting standards in
productivity and competitiveness.
Totally Integrated Automation.
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/5
Siemens KT 10.1 2012
KNX GAMMA instabus
AS-Interface
PROFIBUS
Industrial Ethernet
PROFINET
Totally
Integrated
Power
Industrial Ethernet
Industrial Ethernet
Ethernet
Ethernet
SINAMICS Drive Systems Low-Voltage Distribution
SIMATIC HMI
Human Machine Interface
SIRIUS Industrial Controls
SIMATIC WinCC
SCADA-System
Thanks to Totally Integrated Automation, Siemens provides
an integrated basis for the implementation of customized
automation solutions in all industries from inbound to
outbound.
TIA is characterized by its unique continuity.
It provides maximum transparency at all levels
with reduced interfacing requirements covering
the field level, production control level, up to the
corporate management level. With TIA you also
profit throughout the complete life cycle of your
plant starting with the initial planning steps
through operation up to modernization, where
we offer a high measure of investment security re-
sulting from continuity in the further development
of our products and from reducing the number of
interfaces to a minimum.
The unique continuity is already a defined
characteristic at the development stage of
our products and systems.
The result: maximum interoperability covering
the controller, HMI, drives, up to the process
control system. This reduces the complexity of
the automation solution in your plant. You will
experience this, for example, in the engineering
phase of the automation solution in the form of
reduced time requirements and cost, or during
operation using the continuous diagnostics facili-
ties of Totally Integrated Automation for increasing
the availability of your plant.
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Selecting
Find your products in the structure tree, in the new "Bread-crumb"
navigation or with the integral search machine with expert functions.
Electronic configurators are also integrated into the Mall. Enter the
various characteristic values and the appropriate product will be dis-
played with the relevant order numbers. You can save configurations,
load them and reset them to their initial status.
Ordering
You can load the products that you have selected in this way into the
shopping basket at a click of the mouse. You can create your own tem-
plates and you will be informed about the availability of the products
in your shopping cart. You can load the completed parts lists directly
into Excel or Word.
Delivery status
When you have sent the order, you will receive a short e-mail confir-
mation which you can print out or save. With a click on "Carrier", you
will be directly connected to the website of the carrier where you can
easily track the delivery status.
Added value due to additional information
So you have found your product and want more information about it?
In just a few clicks of the mouse, you will arrive at the image data base,
manuals and operating instructions. Create your own user documen-
tation with My Documentation Manager.
Also available are FAQs, software downloads, certificates and techni-
cal data sheets as well as our training programs. In the image database
you will find, depending on the product, 2D/3D graphics, dimension
drawings and exploded drawings, characteristic curves or circuit
diagrams which you can download.
Convinced? We look forward to your visit!
Much more
than a catalog.
The Industry Mall.
You have a catalog in your hands that will serve
you well for selecting and ordering your products.
But have you heard of the electronic online cata-
log (the Industry Mall) and all its benefits? Take a
look around it sometime:
www.siemens.com/industrymall
KT10_EN_gesamt.book Seite 14 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/7
Siemens KT 10.1 2012
SITOP power supplies
Energy efficient and usable
world-wide
The fan-free power supplies deliver sta-
bilized 24 Volts and are characterized by
their compact and rugged design, high
overload capability, as well as special
energy efficiency. The high efficiency
across the entire load range and the low
no-load loss ensure efficient operation.
The large input voltage range and the
international approvals mean that use is
possible in almost all supply networks
worldwide.
Every day, SITOP is used successfully in
innumerable practical applications.
Quick selection and fast
delivery
With the SITOP Selection Tool - available
in the Internet under
www.siemens.com/sitop-selection-tool
and in the Industry Mall - the suitable
power supply can be selected quickly
and easily The selected products can be
saved or placed into the Mall's shopping
cart and then ordered there.
We deliver all SITOP standard products
from stock to ensure that you receive
the SITOP power supply you selected
quickly.
Customized SITOP products
Our standard power supplies cannot, of
course, satisfy the requirements of ev-
ery application. We can design a specific
power supply for your application-spe-
cific requirements. You benefit from the
expertise of large-scale production and
gain maximum development security
and quality.
Our customer-specific solutions are
used today in many sectors of mechani-
cal engineering, in automation technol-
ogy, vehicle electronics, equipment
manufacturing, or in industrial instru-
mentation technology.
If your are interested, please contact
your local Siemens office.
The benchmark in reliability, compactness and functionality
Efficient operation of a machine or plant requires a reliable, con-
stant power supply. The quality and reliability of the SITOP stabi-
lized power supplies ensure high levels of safety in DC power sup-
ply in industrial engineering and building management systems.
Our extensive selection of SITOP power supplies is enhanced by
expansion modules that extensively protect the 24 V power sup-
plies against interference on the primary and secondary side,
right up to complete all-round protection.
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/8
Siemens KT 10.1 2012
SITOP lite
Low-cost basic power supply
The new range of power supplies is designed for standard re-
quirements in industrial environments and offers all impor-
tant functions at a favorable price, of course without compro-
mising quality and the proverbial SITOP reliability. The wide-
range input with manual switchover supports connection to a
wide range of 1-phase supply systems. Thanks to the narrow
width, the primary switched-mode regulators require little
space on the DIN rail, and the good efficiency results in low
thermal losses in the control cabinet. Short-circuit and over-
load protection as well as UL approval for export ensure prob-
lem-free use.
Its essential characteristics are
24 V/2.5 A, 5 A and 10 A for industrial applications with
standard requirements
1-phase wide-range input with manual switchover
Narrow mounting width
High degree of efficiency
Green LED for "24 V OK"
Parallel connection possible
No lateral installation clearances required
Ambient temperature range of 0 C to 60 C
(above 45 C with derating)
Cooling through natural convection
Short-circuit and overload protection
Certification in accordance with UL
SITOP compact
The slim power supply unit for control boxes
Thanks to the extremely space-saving slim design, the new
power supply series for the lower performance range is espe-
cially suited to distributed applications in control boxes or in
small control cabinets. The switched-mode power supplies are
characterized by their low power losses throughout the load
range. The losses are extremely low even during idling which
predestines them for supplying machines and plants which
are frequently in stand-by mode. The SITOP PSU100C power
supplies have a wide-range input for AC and DC networks;
plug-in terminals facilitate the electrical connection.
Its essential characteristics are
For 24 V at 0.6 A, 1.3 A, 2.5 A and 4 A and for 12 V at 2 A
and 6.5 A
Small mounting surface thanks to its slim design
Wide-range input for 85 V to 264 V AC or 110 V to 300 V DC
High efficiency across the entire load range. Up to 28 % en-
ergy savings in comparison with similar devices
Low energy consumption during no-load operation or
stand-by. Energy savings of up to 53 % are possible
Adjustable output voltage
Green LED for "Output voltage OK"
Plug-in terminals
Temperature range from -20 C to +70 C
Comprehensive certifications, such as ATEX
KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/9
Siemens KT 10.1 2012
LOGO!Power
The flat power supply unit for distribution boards
The new miniature power supply units now offer even greater
performance in the smallest space: The efficiency has been
improved across the entire load range, and the power loss in
no-load operation has been cut in half. The wide-range input
now also allows operation with direct voltage, the switch-on
behavior has been optimized for capacitive loads, and the op-
erating temperature range has been extended to +70 C. The
power supplies with logic module design can be used ex-
tremely flexibly in numerous applications thanks to their
flat, stepped profile in distribution boards, for example.
Its essential characteristics are
2 performance classes, each with 5 V, 12 V, and 15 V
3 performance classes with 24 V
Flat LOGO! design
Wide-range input for 85 V to 264 V AC or 110 V to 300 V DC
Constant current for connection of loads with high inrush
current
Power reserve on starting up through 1.5 times the rated
current for capacitive loads
Adjustable output voltage
Green LED for "Output voltage OK"
Temperature range from -20 C to +70 C
Comprehensive certification, e.g. ATEX and GL
SITOP smart
The powerful standard power supply
SITOP smart is the optimum power supply for many 24 V ap-
plications, with the new SITOP PSU300S 10 A, 20 A, and 40 A
now also for 3-phase networks. Whether 1-phase or 3-phase:
They offer compact dimensions, a strong performance, and a
favorable price. Despite its compactness it offers an outstand-
ing overload withstand capability.
Thanks to the extra power feature with 1.5 times the rated
current for 5 seconds, even large loads can be switched on
without any problems. With a continuous rated power of 120
percent, the slim power supply units are among the most reli-
able of their kind.
Numerous certifications facilitate the universal and global use
and permit their use in hazardous areas .
Its essential characteristics are
24 V/2.5 A, 5 A, 10 A, 20 A and 40 A for standard
applications
24 V/10 A wall-mounted for high shock and vibration
requirements
Capable of providing extra power (150 %) for brief
operational overloads
Can be permanently overloaded with 120 %
(provided ambient temperature is less than 45 C)
No lateral installation clearances required
Output voltages are adjustable up to 28 V
PSU300S: With signaling contact 24 V DC OK
Comprehensive certification, e.g. GL and ATEX
Expandable with DC UPS, and extension modules
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/10
Siemens KT 10.1 2012
SITOP power supplies in SIMATIC design
The optimum supply for SIMATIC S7 and more
The original SIMATIC power supplies merge perfectly into the
PLC network in terms of their design and functionality. In ad-
dition to the following SIMATIC systems, they also supply fur-
ther loads reliably with 24 V.
Its essential characteristics are
SIMATIC S7-1200 The compact PM1207 power module
supplies power to the new micro PLCs. The automatic
range switchover ensures problem-free connection to
1-phase 120 to 230 V grids.
SIMATIC S7-200 This flat power supply unit is also used
for low installation depths.
SIMATIC S7-300 These innovative power supplies require
up to 33 % less space on the S7 rail than the previous
PS307. The range switchover to 1-phase 120/230 V AC
grids now takes place automatically, thus preventing oper-
ator errors. The scope of supply includes the connection
comb for the CPU, an optional adapter permits mounting
on a DIN rail.
The SIMATIC ET 200pro The power supply unit with IP67
is used as electronics/encoder supply and load voltage sup-
ply of the new I/O device. With a signaling contact for "24 V
OK" and "Overtemperature", as well as a second plug-in
connector for input voltage loop-through.
SITOP modular
The technology power supply for demanding solutions
SITOP modular fulfills the highest functionality requirements,
e.g. for use in complex plants and machines. The wide-range
input allows a connection to almost any electrical power sys-
tem worldwide and ensures a high degree of safety even if
there are large voltage fluctuations. The power boost provides
up to three times the rated current for brief periods. In the
event of an overload, you have two options: Constant current
with automatic restart or latching shutdown.
The innovated power supplies SITOP PSU100M 20 A with 1-
phase connection, the SITOP PSU300M 20 and 40 A 3-phase,
and the SITOP PSU400M 20 A with a second DC input have
even more to offer. Due to their slim design, they are among
the most compact units in their performance class. The inno-
vations include the integrated signaling contact for "24 V OK",
the extended input range, the high efficiency and 1.5 times
the rated current for up to 5 seconds.
Its essential characteristics are
For demanding applications from 5 to 40 A
DC/DC converter 24 V/20 A for drive and battery networks
48 V/10 A and 20 A enable small cable cross-sections
Compact metal enclosure
No lateral installation clearances required
Wide-range input
Extra power of 150 % for brief operational overloads
Power boost of 300 % for tripping protective devices
Selectable short-circuit response
A soft characteristic can be selected for parallel connection
High efficiency
Operating status on 3 LEDs
Expandable with SITOP add-on modules and DC UPS
KT10_EN_gesamt.book Seite 10 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/11
Siemens KT 10.1 2012
SITOP in special designs, made for special tasks
Well prepared for special tasks and conditions
Whether restricted installation conditions, harsh ambient con-
ditions, or special input or output voltages are concerned:
These standard power supply units also fulfill exceptional re-
quirements.
It is the purpose of the new, low cost power supplies
PSU100D, which reside in an aluminium housing, to provide
you with 12 V and 24 V voltages. The sturdy aluminium hous-
ing can be screwed directly to a wall. Or, if the task a t hand is
to charge batteries, you can use the SITOP PSU300B which is
optimized for battery charging. This PS comes in slim design
and 3-phase wide range input.
Its essential characteristics are
PSU100D cost-effective power supplies up to 300 W, for
direct wall mounting, in many orientations.
SITOP flat design with flat metal housing, suitable for DIN
rail mounting.
SITOP PSA100E for DIN rails or wall mounting
SITOP 3.7 A Class II, with power limiter set to 100 W
SITOP PSU300P in IP67 type of protection, identical in
construction to SIMATIC ET 200pro PS, but without the sec-
ond connector for looping the input voltage.
SITOP PSU300B power supply optimized for battery
charging, with 3-phase wide-range input, 12 V and 24 V
output voltages.
Alternative voltages
Power supplies with alternative output voltages
SITOP provides a reliable supply of precisely stabilized DC volt-
age not just to 24 V loads, but also to loads with "alternative"
supply voltages.
SITOP flexi: 3 52 V/10 A
Limitless diversity thanks to variable output. Allows flexible
adjustment between 3 and 52 V, so just one standard PS can
be used for different voltages.
SITOP compact: 12 V/2 A and 6.5 A
Narrow power supply, designed for switching cubicles, also
suitable for 12 V consumers.
LOGO!Power: 5 V, 12 V and 15 V
Flat power supply, for installation junction boxes, available in
two power classes.
SITOP modular: 48 V/10 A und 20 A
The high output voltage allows smaller strand cross sections
for wires leading to consumers.
SITOP DC/DC: 12 V/2.5 A
The DC/DC converter features a narrow DIN rail housing and
needs a 24 V DC input voltage. It is possible to operate it in
conjunction with a SITOP DC UPS, thus obtaining uninterrupt-
ible 12 V.
SITOP dual: 2 x 15 V/3.5 A
The electronics power supply for the control cabinet. The in-
dustry-standard rail-mounted device has two 15 V outputs.
For example, for electronic loads requiring 15 V.
KT10_EN_gesamt.book Seite 11 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/12
Siemens KT 10.1 2012
Expansion modules
Reliable protection against the most varied hazard
sources: SITOP expansion modules
A power supply unit on its own cannot guarantee fault-free
24 V supply. Power failures, extreme variations in the mains
voltage, or a faulty load can bring plant operation to a stand-
still and cause high costs. The expansion modules offer every-
thing from extensive protection against interference on the
primary and secondary side right up to complete all-round
protection.
The signaling module with signal contacts and remote ON/
OFF function optimally integrates SITOP modular (devices
without integral signaling contact) into automated plants.
For maximum availability, the redundancy module decou-
ples SITOP power supplies of the same type.
The buffer module bridges short power failures up to 3 sec-
onds with capacitors as energy storage.
The SITOP select diagnostics module and the new SITOP
PSE200U selectivity module offer selective protection of in-
dividual 24 V paths against overload and short-circuits.
With this protection and by means of fast fault localization,
downtimes can be reduced to a minimum. New features of
the selectivity module include the finely adjustable current
range (from 0.5 A), remote reset, and a reset button for
each channel.
DC UPS
Permanently reliable 24 V even when the power fails:
Uninterruptible power supplies
Supply network irregularities in the millisecond range are
compensated for supremely well by all our power supplies.
Large fluctuations or even power failures, however, require
special measures: The buffer module (see SITOP expansion
modules) ensures optimal protection in the case of brief
power failures up to 3 seconds.
SITOP UPS500 uses capacitors to cover power failures in the
time range of minutes. Its essential characteristics are:
Absolutely maintenance free DC UPS featuring high-capac-
ity double-layer capacitors.
Modularly cascadable for standard mounting rail: Basic
unit SITOP UPS500S 24 V / 15 A with integrated energy stor-
age 2.5 oder 5 kWs, combinable with up to three expansion
modules UPS501S (5 kWs).
SITOP UPS500P 24 V / 7 A, 5 or 10 kWs in IP65 type of pro-
tection, for distributed use.
Long-life capacitors protect your investment, replacements
can be postponed:
After 8 years the UPS500 (at 50 C ambient temperature)
still retains 80 % of its rated capacity.
No ventilation is required in the installation area
(VDE 0510 Part 2 / EN 50272-2).
Fast restoration of buffering capability.
DC UPS modules outfitted with batteries secure operation in
the time range of hours. Its essential characteristics are:
DC UPS modules 6 A, 15 A and 40 A.
Maintenance-free battery modules from 1.2 to 12 Ah.
High security and availability due to monitoring of back-up
capability status, battery cables, aging and charging status.
Long service life of consumers, and batteries , facilitated by
an integrated battery management.
DIP switches can be used for setting the following: Connec-
tion threshold for buffering, end-of-charge voltage, charg-
ing current, buffering time.
Uninterrupted transition from buffer ready to buffering.
Both DC UPS systems can be incorporated into PC-based auto-
mation solutions with a free software tool. This tool supports
the processing of status annunciations and the secure shut-
ting down of the PC.
KT10_EN_gesamt.book Seite 12 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/13
Siemens KT 10.1 2012
SITOP Selection Tool
find the appropriate power supply quickly and easily
The SITOP Selection Tool is available in the Internet under
www.siemens.com/sitop-selection-tool
and also in the Industry Mall. This tool enables you to find the
appropriate power supply in just a few steps.
And this is how it works:
Entering a few technical specifications the tool will automat-
ically select the relevant parameters and show the matching
products. You can edit the selection parameters anytime.
An added support is provided by the possibility to compare
several products according to their technical data. You can se-
lect between "all data", "all identical data" and "all different
data".
The products thus selected can be transferred into a product
list. You can export this list into several file formats, or even let
the Industry Mall adopt this list in the cart. It is also possible to
invoke additional data concerning the selected products, for
example 3D data, circuit diagram macros, or certificates.
First step: Preselect the relevant power supplies with the help of technical
properties
Second step: To further limit the selection compare the technical data of
several power supplies
Third step: Once you have have selected the appropriate product, you can
export the data or transfer it into the Industry Mall
KT10_EN_gesamt.book Seite 13 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/14
Siemens KT 10.1 2012
Input voltage Output current SITOP
lite
SITOP
compact
LOGO!Power SITOP
smart
SIMATIC design SITOP
modular
Special design
special uses
Output voltage 24 V DC The complete technical specifications on these products are on the pages shown
1-phase AC
120 V, 230 V 0.6 A 2/2
1.3 A 2/2 2/3
2 A 2/3
2.1 A 3/3
2.5 A 3/3 3/2 3/2 3/2 3/3 3/3
3.1 A 4/3
3.5 A 4/2
3.7 A 4/3
4 A 4/2 4/2 4/3
4.1 A 4/3
5 A 5/3 5/2 5/3 5/2 5/3
6 A 6/2
6.2 A 6/2
10 A 7/3 7/2 7/3 7/2 7/3
12 A 8/2
12.5 A 8/2
20 A 8/2, 8/3
40 A 8/3
1-phase DC
48 ... 220 V 0.375 A 2/2
48 ... 110 V 2 A 2/3
24 ... 110 V 2 A 2/3
110 ... 300 V 0.6 A 2/2
1.3 A 2/2 2/3
2.5 A 3/2 3/2
4 A 4/2 4/2
120 ... 375 V 2.1 A
3.1 A
4.1 A
6.2 A
12 A
200 ... 900 V 20 A 8/3
3-phase AC
400 ... 500 V 5 A 5/2, 9/2
8 A 9/2
10 A 9/3 7/2, 9/2
20 A 9/3 8/2, 8/3, 9/3
30 A 10/2
40 A 10/3 8/3, 10/2, 10/3
Selection table
SITOP power supplies
KT10_EN_gesamt.book Seite 14 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/15
Siemens KT 10.1 2012
Input voltage Output current SITOP
lite
SITOP
compact
LOGO!Power SITOP
smart
SIMATIC design SITOP
modular
Special design
special uses
Output voltage
5, 12, 15, 48 V DC
The complete technical specifications on these products are on the pages shown
1-phase AC
120 V, 230 V 3 - 52 V/
2 - 10 A
13/2
5 V/3 A 13/4
5 V/6.3 A 13/4
12 V/1.9 A 13/6
12 V/2 A 13/6
12 V/3 A 13/7
12 V/4.5 A 13/7
12 V/6.5 A 13/7
12 V/8.3 A 13/10
15 V/1.9 A 13/12
15 V/4 A 13/12
2 x 15 V/3.5 A 13/12
1-phase DC
24 V 12 V/2.5 A 13/6
110 ... 300 V 5 V/3 A 13/4
5 V/6.3 A 13/4
12 V/1.9 A 13/6
12 V/2 A 13/6
12 V/4.5 A 13/7
12 V/6.5 A 13/7
15 V/1.9 A 13/12
15 V/4 A 13/12
3-phase AC
400 ... 500 V 12 V/20 A 13/10
48 V/10 A 13/14
48 V/20 A 13/14
KT10_EN_gesamt.book Seite 15 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/16
Siemens KT 10.1 2012
KT10_EN_gesamt.book Seite 16 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
2
2/2 The smallest ones 0.375 A
2/2 SITOP PSU100C 0.6 A
2/2 SITOP PSU100C 1.3 A
2/3 LOGO!Power 1.3 A
2/3 The S7-300 version 2 A
2/3 The outdoor version 2 A
2/3 The DC/DC converter 2 A
2/6 Ordering data and additional information
SITOP 1-phase
24 V DC, up to 2 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current up to 2 A
2/2
Siemens KT 10.1 2012
2
Overview
Technical data
1)
SIPLUS module see page 15/2.
Product Special design
The smallest ones
SITOP compact
PSU100C
SITOP compact
PSU100C
Power supply, type 0.375 A 0.6 A 1.3 A
Order No. 6EP1 731-2BA00
1)
6EP1 331-5BA00 6EP1 331-5BA10
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
The optimum power supply units for
automation solutions in the lowest
performance range; with wide-
range input for AC or DC voltages;
thanks to their compact and slim
design, they are particularly
suitable for solutions where space
is limited and in conjunction with
low-voltage switchgear.
Narrow power supply in the lower
performance range, e.g. for
distributed use in cubicles.
Low energy consumption over the
entire power range, minimal
energy loss at no load, with
removable terminals.
Narrow power supply in the lower
performance range, e.g. for
distributed use in cubicles.
Low energy consumption over the
entire power range, minimal
energy loss at no load, with
removable terminals.
Product Special design
The smallest ones
SITOP compact
PSU100C
SITOP compact
PSU100C
Input
DC voltage 1-phase AC or DC 1-phase AC or DC
Rated voltage value V
in rated
48-220 V DC
Wide-range input
100-230 V AC
Wide-range input
100-230 V AC
Wide-range input
Voltage range 30 ... 264 V
(AC 30 ... 187 V AC)
85 ... 264 V AC or 110 ... 300 V DC 85 ... 264 V AC or 110 ... 300 V DC
Overvoltage resistance 2.3 x V
in
rated
, 1.3 ms 2.3 x V
in
rated
, 1.3 ms
Mains buffering
at I
out rated
> 10 ms at V
in
= 220 V > 20 ms at V
in
= 230 V > 20 ms at V
in
= 230 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
0.3-0.06 A 0.28-0.18 A 0.63-0.31 A
Switch-on current limit (+25 C) < 35 A, typ. 3 ms < 28 A < 34 A
I
2
t 1.2 A
2
s 0.7 A
2
s 1.2 A
2
s
Built-in incoming fuse F 4 A/250 V (not accessible) Internal Internal
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
6 A or higher, characteristic C,
suitable for DC
16 A or higher, characteristic B or
10 A or higher, characteristic C
16 A or higher, characteristic B or
10 A or higher, characteristic C
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
24 V DC 24 V DC 24 V DC
Total tolerance 3 % 3 % 3 %
Static line compensation Approx. 0.1 % Approx. 0.1 %
Static load compensation Approx. 0.1 % Approx. 0.2%
Residual ripple < 150 mV
pp
(typ. 50 mV
pp
) < 200 mV
pp
(typ. 40 mVpp) < 200 mV
pp
(typ. 25 mVpp)
Spikes (bandwidth: 20 MHz) < 240 mV
pp
(typ. 50 mV
pp
) < 300 mV
pp
(typ. 20 mVpp) < 300 mV
pp
(typ. 20 mVpp)
Adjustment range 22.2 ... 26.4 V
Status display Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
On/off behavior No overshoot of V
out
(soft start)
Overshoot of V
out
approx. 5 % Overshoot of V
out
approx. 5 %
Startup delay /
voltage rise
< 2.5 s/typ. 90 ms < 1 s/typ. 25 ms < 0.6 s/typ. 90 ms
Rated current value I
out rated
0.375 A 0.6 A 1.3 A
Current range
Up to +60 C 0 ... 0.375 A 0 ... 0.6 A (up to +55 C) 0 ... 1.3 A (up to +55 C)
Derating 0 ... 0.255 A (up to +70 C) 0 ... 0.33 A (up to +70 C) 0 ... 0.7 A (up to +70 C)
Dynamic overcurrent on
Power-up on short circuit
Short circuit during operation Typ. 2.7 A for 200 ms Typically 1 A Typically 3.1 A
Parallel switching for
enhanced performance
Not permitted Not permitted Yes, 2 units
NEW NEW
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current up to 2 A
2/3
Siemens KT 10.1 2012
2
2)
SIPLUS module see page 15/2.
LOGO!Power SITOP in SIMATIC design
The S7-300 version
SITOP in SIMATIC design
The outdoor version
Special design
The DC/DC converter
1.3 A 2 A 2 A 2 A
6EP1 331-1SH03 6ES7 307-1BA01-0AA0 6ES7 305-1BA80-0AA0
2)
6EP1 732-0AA00
LOGO!Power supplies are
optimally matched in design and
functionality to the LOGO! logic
modules; with wide-range input
85 V to 264 V AC and 110 V to
300 V DC, as well as an option for
installing in built-in miniature
distribution boards, they can be
used universally in the low-end
performance range.
The proven power supply in
SIMATIC S7-300 design; with PS-
CPU connecting comb and for
mounting directly on S7 rail.
The power supply for extreme
environmental conditions in
SIMATIC S7-300 design; can be
snapped onto S7 rail; with
PS-CPU connecting comb.
The DC/DC converter for
supply from battery and DC
systems; with a wide input voltage
range from 38 V to 121 V DC.
LOGO!Power SITOP in SIMATIC design
The S7-300 version
SITOP in SIMATIC design
The outdoor version
Special design
The DC/DC converter
1-phase AC or DC 1-phase AC DC voltage DC voltage
100-240 V AC
Wide-range input
120/230 V AC
Automatic
range switch-over
24 V-110 V DC
Wide-range input
48-110 V DC
Wide-range input
AC 85 ... 264 V or DC 110 ... 300 V 85 ... 132 V/170 ... 264 V 16.8 ... 138 V 38 ... 121 V
2.3 V
in
rated
, 1.3 ms 2.3 V
in
rated
, 1.3 ms 154 V; 0.1 s
> 40 ms at V
in
= 187 V > 20 ms at V
in
= 93/187 V > 10 ms at V
in rated
> 5 ms at V
in
= 48 V
50/60 Hz; 47 ... 63 Hz 50/60 Hz, 47 ... 63 Hz
0.7-0.35 A 0.9/0.5 A 2.7-0.6 A (4.0-0.9 A) 1.2-0.5 A
< 25 A < 22 A, < 3 ms < 20 A, < 10 ms < 33 A
< 0.8 A
2
s < 1.0 A
2
s < 5 A
2
s
Internal T 1.6 A/250 V (not accessible) T 6.3 A/250 V (not accessible) T 2.5 A (not accessible)
16 A or higher, characteristic B or
10 A or higher, characteristic C
3 A, characteristic C 10 A or higher, characteristic C,
suitable for DC
10 to 25 A, characteristic B, or 6 to
25 A, characteristic C,
DC-compatible
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
24 V DC 24 V DC 24 V DC 24 V DC
3 % 3 % 3 % 1 %
Approx. 0.1 % Approx. 0.1 % Approx. 0.2 % Approx. 0.1 %
Approx. 1.5 % Approx. 0.2 % Approx. 0.4% Approx. 0.4 %
< 200 mV
pp
(typ. 10 mV
pp
) < 50 mV
pp
(typ. < 5 mV
pp
) < 150 mV
pp
(typ. < 30 mV
pp
) < 100 mV
pp
< 300 mV
pp
(typ. 20 mV
pp
) < 150 mV
pp
(typ. < 20 mV
pp
) < 240 mV
pp
(typ. < 150 mV
pp
) < 300 mV
pp
22.2 ... 26.4 V 23.5 ... 26.5 V
Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
No overshoot of V
out
(soft start)
No overshoot of V
out
(soft start)
No overshoot of V
out
(soft start)
Overshoot of V
out
on startup max.
25 V
< 0.5 s/typ. 15 ms < 2 s/typ. 10 ms < 3 s/typ. 5 ms < 3 s/typ. 30 ms
1.3 A 2 A 2 A (3 A at V
in
> 24 V) 2 A
0 ... 1.3 A (up to +55 C) 0 ... 2 A 0 ... 2 A (3 A) 0 ... 2 A
0 ... 0.9 A (up to +70 C) 0 ... 2 A (up to +70 C)
Typ. 9 A for 90 ms Typ. 9 A for 270 ms
Typ. 9 A for 90 ms Typ. 9 A for 270 ms
Yes, 2 units Yes Yes, 2 units Yes, 2 units
NEW
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current up to 2 A
2/4
Siemens KT 10.1 2012
2
Technical specifications (continued)
Product Special design
The smallest ones
SITOP compact
PSU100C
SITOP compact
PSU100C
Power supply, type 0.375 A 0.6 A 1.3 A
Order No. 6EP1 731-2BA00 6EP1 331-5BA00 6EP1 331-5BA10
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 66% Approx. 82 % Approx. 86 %
Power loss at V
out rated
, I
out rated
Approx. 4.6 W Approx. 2.6 W Approx. 4.5 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
Typ. 0.3 % V
out
Typ. 0.1 % V
out
Typ. 0.1 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. 0.4 % V
out
Typ. 3 % V
out
(I
out
: 10/90/10 %)
Typ. 3 % V
out
(I
out
: 10/90/10 %)
Load step settling time
50 to 100 % Typ. 2 ms Typ. 3 ms (10 to 90 %) Typ. 5 ms (10 to 90 %)
100 to 50 % Typ. 2 ms Typ. 3 ms (10 to 90 %) Typ. 5 ms (10 to 90 %)
Protection and monitoring
Output overvoltage protection Yes, according to EN 60950 Yes, according to EN 60950 Yes, according to EN 60950
Current limitation 0.41 ... 0.49 A Typically 0.7 A Typically 1.4 A
Short-circuit protection Electronic shutdown, auto restart Electronic shutdown, auto restart Electronic shutdown, auto restart
Sustained short-circuit current rms
value
< 0.9 A
Overload/short-circuit indicator
Safety
Primary/secondary isolation Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Protection class Class I Class I Class I
Leakage current < 3.5 mA < 3.5 mA < 3.5 mA
Safety test Yes Yes; CB Scheme Yes; CB Scheme
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2
No. 142), File E143289; cURus-
recognized (UL 60950, CSA C22.2
No. 60950), File E151273
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cCSAus (CSA C22.2 No. 60950-1,
UL 60950-1)
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cCSAus (CSA C22.2 No. 60950-1,
UL 60950-1)
Explosion protection ATEX (EX) II 3G Ex nA IIC T4;
cCSAus (CSA C22.2 No. 213-
M1987, ANSI/ISA-12.12.01-2007)
Class I, Div. 2. Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T4;
cCSAus (CSA C22.2 No. 213-
M1987, ANSI/ISA-12.12.01-2007)
Class I, Div. 2. Group ABCD, T4
FM approval
Marine approval GL and ABS available soon GL and ABS available soon
Degree of protection (EN 60529) IP20 IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation Not applicable Not applicable Not applicable
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range -25 ... +70 C with natural
convection
-20 ... +70 C with natural
convection
-20 ... +70 C with natural
convection
Transport/storage temp. range -40 ... +70 C -40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L, N, PE
(DC input: L+1, M1, PE)
1 screw terminal each for
0.5 ... 2.5 mm
2
single-core/finely stranded
Removable screw terminals,
one each 0.5 ... 2.5 mm
2
solid/finely stranded
Removable screw terminals,
one each 0.5 ... 2.5 mm
2
solid/finely stranded
Output + 1 screw terminal for
0.5 ... 2.5 mm
2
1 screw terminal for
0.5 ... 2.5 mm
2
1 screw terminal for
0.5 ... 2.5 mm
2
Output 2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
Dimensions (W x H x D) in mm 22.5 80 91 22.5 x 80 x 100 30 x 80 x 100
Weight, approx. 0.14 kg 0.12 kg 0.17 kg
Installation Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail
EN 60715 35x7.5/15
Accessories
Removable spring-loaded
terminals (6EP1971-5BA00)
Removable spring-loaded
terminals (6EP1971-5BA00)
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current up to 2 A
2/5
Siemens KT 10.1 2012
2
LOGO!Power SITOP in SIMATIC design
The S7-300 version
SITOP in SIMATIC design
The outdoor version
Special design
The DC/DC converter
1.3 A 2 A 2 A 2 A
6EP1 331-1SH03 6ES7 307-1BA01-0AA0 6ES7 305-1BA80-0AA0 6EP1 732-0AA00
Approx. 85 % Approx. 84% Approx. 75 % Approx. 84 %
Approx. 6 W Approx. 9 W Approx. 16 W (24 W) Approx. 9 W
<0.2 % V
out
Typ. 0.1 % V
out
Typ. 0.3 % V
out
Typ. 0.3 % V
out
Typ. 1 % V
out
(I
out
: 10/90/10 %)
Typ. 0.8 % V
out
Typ. 2.5 % V
out
Typ. 0.8 % V
out
Typ. 1 ms (10 to 90 %) < 1 ms (typ. 0.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms)
Typ. 1 ms (90 to 10%) < 1 ms (typ. 0.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms)
Yes, according to EN 60950 Additional control loop, shutdown
at < 28.8 V, automatic restart
Additional control loop, shutdown
at approx. 30 V, automatic restart
Yes, suppressor diode at output
Typically 1.7 A 2.2 ... 2.6 A 3.3 ... 3.9 A 2.1 ... 3 A
Constant current characteristic Electronic shutdown, auto restart Electronic shutdown, auto restart Electronic shutdown, auto restart
< 2.4 A < 2 A < 2 A < 2 A
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Yes, SELV output V
out
acc. to
EN 60950-1, EN 50178, creepage
distances and clearances > 5 mm
Yes, safety extra low output
voltage V
out
according to
EN 60950-1
Class II (without protective conductor) Class I Class I Class I
< 3.5 mA (typ. 0.5 mA) < 3.5 mA (typ. 0.7 mA) < 3.5 mA (typ. 0.7 mA)
Yes; CB Scheme Yes Yes Yes
Yes Yes Yes Yes
cULus-listed (UL 508, CSA C22.2 No.
107.1), File E197259; cURus-recognized
(UL 60950, CSA C22.2 No. 60950),
File E151273
cULus-Listed (UL 508, CSA C22.2
No. 142), File E143289
UL-listed (UL 508),
File E143289, CSA
(CSA C22.2 No. 142)
cULus-listed (UL 508, CSA C22.2
No. 142), File E179336
ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Group ABCD, T4
ATEX (EX) II 3G Ex nA II T4;
UL 1604 Class I Div. 2
Group ABCD
Class I Div. 2. Group ABCD, T4 Class I Div. 2. Group ABCD, T4
GL, ABS In S7-300 system
IP20 IP20 IP20 IP20
EN 55022 Class B EN 55022 Class B EN 55011 Class A EN 55022 Class B
Not applicable Not applicable Not applicable Not applicable
EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
-20 ... +70 C with natural convection 0 ... +60 C with natural
convection
-25 ... +70 C with natural
convection
0 ... +70 C with natural
convection
-40 ... +85 C -40 ... +85 C -40 ... +85 C -40 ... +70 C
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K5 according to EN
60721, transient condensation
permitted
Climate class 3K3 according to
EN 60721, no condensation
One screw-type terminal each (L, N)
for 0.5 ... 2.5 mm
2
solid/finely stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
1 screw terminal each for
0.5 ... 2.5 mm
2
single-core/finely
stranded
One screw-type terminal each for
2 0.5 ... 2.5/1.5 mm
2
solid/finely stranded
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
1 screw terminal for
2 0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
1 screw terminal for
2 0.5 ... 2.5 mm
2
54 90 55 40 125 120 80 125 120 80 135 120
0.17 kg 0.4 kg 0.75 kg 0.5 kg
Snaps onto DIN rail
EN 60715 35x7.5/15
Can be mounted onto S7 rail Can be mounted onto S7 rail Snaps onto DIN rail
EN 60715 357.5/15
Mounting adapter for standard
mounting rail (6EP1 971-1BA00)
Mounting adapter for DIN rail
(6ES7 390-6BA00-0AA0)
Dimensions (W H D) in mm 72 80 72 72 80 72 72 90 90
Weight, approx. 0.2 kg 0.2 kg 0.4 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
24 V DC
PSE200U selectivity module,
SITOP select diagnostics module
11/6
Siemens KT 10.1 2012
11
Characteristics
Switch-off characteristic
Circuit diagrams
Switching principle SITOP select
Switching principle SITOP PSE200U
0 20 40 60 80 100 120 140 %
Load current
R
e
l
e
a
s
e
t
i
m
e
100.0
10.0
1.0
0.1
0.0
5.0 s
0.10 s
rated
G
_
K
T
0
1
_
E
N
_
0
0
0
6
2
s
-
Reset
24V
G
_
K
T
0
1
_
E
N
_
0
0
0
6
3
a
Power supply
Control Logics
Floating
signaling
contact
Load 1 Load 2 Load 3 Load 4
SITOP select
+ 24V
Power supply, e.g. SITOP
SITOP PSE200 U
Remote
reset
(24 V DC)
Floating
signaling
contact
Control
Logics
Load
1
Load
2
Load
3
Load
4
G_KT01_EN_00378
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
100 - 480 V AC
SITOP inrush current limiter
11/7
Siemens KT 10.1 2012
11
Overview
Technical specifications
Product SITOP inrush current limiter
Order No. 6EP1 967-2AA00
The SITOP inrush current limiter module is used to reliably reduce the
starting currents that are caused, for example, by capacitors or with
pulse-controlled power supplies by the rectifier circuit on the input side
with capacitor charging
In 1-phase AC networks, it is supplied with rated voltages of 100 V,
120 V or 230 V and in 2-phase and 3-phase AC networks with 208 V to
480 V on the line side upstream of capacitors and power supplies and it
limits the inrush current temperature-independently up to e. g. < 10 A at
230 V. In static operation the limit resistance is bypassed after approx.
120 ms and the resulting power loss is reduced.
Product SITOP inrush current limiter
Order No. 6EP1 967-2AA00
Input
AC voltage 1-phase, 2-phase,
50/60 Hz
Rated voltage value V
in rated
100 ... 480 V AC
Voltage range 85 ... 575 V
Overvoltage resistance
Input current I
in rated
Output
Rated voltage V
out rated
In accordance with
the supply voltage
Rated current value I
out rated
Max. 10 A
Mains buffering
Buffering time, max.
Parallel switching for
enhanced performance
No
Protection and monitoring
Current limiting, static
Short-circuit protection Must be ensured with an upstream
protective device
Signaling/alarm signals
Status display Green LED
Alarm signals
Product SITOP inrush current limiter
Order No. 6EP1 967-2AA00
Safety
In accordance with EN 60950-1
and EN 50178
Galvanic isolation No
Protection class Class II
CE mark Yes
UL/cUL (CSA) approval Yes, cULus-listed (UL 508, CSA
C22.2 No. 107.1), File E197259
Degree of protection (EN 60529) IP20
EMC
Emitted interference EN 61000-6-3
Noise immunity EN 61000-6-2
Operating data
Permitted ambient temperature 0 ... +60 C with natural
convection
Transport/storage temperature
range
-40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections Input and output (L1, N):
One screw terminal each for
0.2 ... 2.5 mm
2
single-core/finely
stranded;
Dimensions (W H D) in mm 22.5 80 91
Weight, approx. 0.12 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
100 - 480 V AC
SITOP inrush current limiter
11/8
Siemens KT 10.1 2012
11
Circuit diagrams
SITOP inrush current limiter connection diagram
1 Phase 2 Phases 3 Phases* 3 Phases without
G
_
K
T
0
1
_
E
N
_
0
0
3
5
0
* Note: For 3-phase applications N shall only be wired on the input side for internal power supply. N must not be wired on the output side.
PE L1.1 N PE L1.1 L2.1 PE L1.1 L2.1 L3.1 PE L1.1 L2.1 L3.1
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
N
PE PE PE N N L3 L2 L2 L1 L1 L1 L3 L2 L1 PE
KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
24 V DC / 100 - 480 V AC
11/9
Siemens KT 10.1 2012
11
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP modular signaling module
6EP1 961-3BA10
PSE202U redundancy module
24 V DC V
in
approx. 0.5 V 20 A 6EP1 961-3BA21
SITOP modular buffer module
24 V DC V
in
approx. 1 V 40 A 6EP1 961-3BA01
SITOP PSE200U selectivity module
24 V DC V
in
approx. 0.2 V 4 x 3 A 6EP1 961-2BA11
4 x 10 A 6EP1 961-2BA21
SITOP select diagnostics module
24 V DC V
in
approx. 0.3 V 4 x 10 A 6EP1 961-2BA00
SITOP inrush current limiter
100-480 V AC 100-480 V AC 10 A 6EP1 967-2AA00
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
Notes
11/10
Siemens KT 10.1 2012
11
Mechanics
Input connections 24 V DC 2 screw terminals for 1 ... 4 mm
2
/17 ... 11 AWG See connector set
1)
Output connections 24 V DC 4 screw terminals for 1 ... 4 mm
2
/17 ... 11 AWG See connector set
1)
Connections for control circuit and
alarm signals
10 screw terminals for 0.5 ... 2.5 mm
2
/20 ... 13 AWG not applicable
USB port Yes Yes
Dimensions (W x H x D) in mm 120 125 ca. 125 400 (without connector) 80 80
470 (without connector) 80 80
Required clearances 50 mm above and 50 mm underneath unit 50 mm above and 50 mm underneath unit
Weight Approx. 1.0 kg Approx. 1.9 kg
Approx. 2.2 kg
Installation Snaps onto DIN rail EN 60715 35x7.5/15 Screw mounting
Product SITOP UPS501S
Power supply, type Expansion module
Order No. 6EP1 935-5PG01
Additional energy storage
(5 kW)
Up to 3 expansion modules can
be connected to a SITOP
UPS500S to extend the buffer
times
Complete with balancing and
safety circuits
Product SITOP UPS501S
Power supply, type Expansion module
Order No. 6EP1 935-5PG01
Mechanics
Connections Can be easily connected to SITOP
UPS500S via a user-friendly plug-
in system
Dimensions (W H D) in mm Approx. 70 125 125
Weight Approx. 0.7 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
Overview
12/10
Siemens KT 10.1 2012
12
Overview
By combining a DC UPS module with at least one 24 V battery
module and a SITOP power supply unit, longer power failures
can be bridged without any interruption.
The combination is used for example in machine-tool building, in
the textile industry, on all types of production lines and filling
plants, and in conjunction with 24 V industrial PCs. This prevents
the negative effects which often result from power failures.
DC-UPS modules: 6 A, 15 A, 40 A
Battery modules:
1.2 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium, high-capacity grid plates and fiberglass mat)
3.2 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium, high-capacity grid plates and fiberglass mat)
7 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium, high-capacity grid plates and fiberglass mat)
12 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium, high-capacity grid plates and fiberglass mat)
2.5 Ah (contains "high-temperature battery" lead-acid type)
Selection table for battery modules and mains buffering times
Important information for selecting the battery capacity:
The mains buffering times are based on the discharge period
of new or non-aged, fully charged battery modules at a battery
temperature of not less than +25 C down to a battery voltage
of 21 V (with voltage drops in the DC UPS, approximately
20.4 V DC still remain for the load).
Battery aging reduces the still available battery capacity up to
the end of the service life to typically around 50 % of the original
capacity value when new (1.2 Ah or 3.2 Ah or 7 Ah, etc.) and
the internal resistance increases. When the message "Battery
charge > 85 %" appears, only around 50 % 85 % = approx. 43
% of the originally available capacity can be assumed at the
end of the battery service life.
At battery temperatures below +25 C, the available capacity
drops by another 30 % at +5 C battery temperature from ap-
prox. 43 % to approx. 70 %. There is then only around 30 % of
the original capacity available.
A significantly larger battery capacity must therefore be se-
lected when configuring the plant: A drop to approx. 50 % is
compensated for by selecting 1 / approx. 0.5 = approx.
double the battery capacity (required as per the table for the
relevant load current and the relevant buffering time).
Available capacity of approx. 43 % is compensated for by
selecting 1 / approx. 0.43 = approx. 2.33 times battery capacity.
Available capacity of approx. 30 % is compensated for by
selecting 1 / approx. 0.3 = approx. 3.33 times battery capacity.
Recommendation:
Instead of installing double the battery capacity to cope with
battery aging, regular battery replacement midway through
the expected service life (reduction of capacity to approx.
50 %) can be more advisable for the following reasons: Until
the halfway point of the expected battery service life (or
slightly beyond), capacity does not drop below 100 %. With
regular replacement after halfway through expected service
life, only single battery capacity (instead of double capacity)
must be installed regarding aging ( neutral in price with regard
to battery module costs but requires only half the space).
Replacing after half the service life dispenses in particular with
the large scatter range of the residual capacity at the end of
the service life, which is not accurately defined by battery
manufacturers (after the full time, many batteries are above,
but many are also below the average of 50 % residual
capacity, that is, even if double the capacity is installed, the
influence of aging at the end of service life is not reliably
compensated for, but only typically) In the case of
replacement after half the expected service life, the configured
buffering time is maintained significantly more reliably.
Load current Battery module 1.2 Ah
(6EP1935-6MC01)
Battery module 3.2 Ah
(6EP1935-6MD11)
Battery module 7 Ah
(6EP1935-6ME21)
Battery module 12 Ah
(6EP1935-6MF01)
Battery module 2.5 Ah
(6EP1935-6MD31)
1 A 30 min 2.5 h 6 h 11 h 2 h
2 A 11 min 45 min 2.5 h 5 h 45 min
3 A 4 min 25 min 1.5 h 3 h 30 min
4 A 2 min 20 min 45 min 2 h 20 min
6 A 1 min 10 min 30 min 1 h 13 min
8 A 4 min 20 min 40 min 9 min
10 A 1.5 min 15 min 30 min 7 min
12 A 1 min 10 min 25 min 5.5 min
14 A 50 s 8 min 20 min 4.5 min
16 A 40 s 6 min 15 min 4 min
20 A 2 min 11 min
KT10_EN_gesamt.book Seite 10 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
Overview
12/11
Siemens KT 10.1 2012
12
Overview (continued)
In the case of batteries stored in cool conditions (not
exceeding +25 C) and for not longer than approximately 4
months, the following service life can be assumed, strongly
dependent on battery temperature:
In normal cases (installation in the coolest location in the
control cabinet at approx. +30 C), the battery with single
installed battery capacity should be replaced in accordance
with the selection table after 1 year of operation!
On the DC UPS module 40 A, at least 2 battery modules of 7 Ah
or higher must be connected in parallel for output currents > 30
A. When connecting battery modules in parallel, you must ensure
identical capacity and aging.
After a power failure, the battery module is disconnected from the
loads at the end of the selected buffering time either
automatically or electronically by opening the On/Off control
circuit, and as soon as the 24 V input voltage is available again,
it is quickly re-charged with the charge current of the relevant DC
UPS module (with I-V charge characteristic: First constant
current I for fast charging, and changeover to constant voltage V
to maintain the charge when the battery is almost full).
Integration
Battery
temperature
Drop to
approx. 50 % of
residual
capacity
Recommenda-
tion:
Replace all (with
100 %
residual
capacity)
Alternative
recommendation
+20 C 4 years 2 years
+30 C 2 years 1 year
+40 C 1 year 0.5 years Install double
capacity and
replace
(1 per year)
1
X3.1-9
L+ X1.1
M X1.2
Input V
e
24V DC
DC
DC
X1.7 +Bat
27-
18.5V DC
X1.8 -Bat
X1.3 L+
X1.4 M
X1.6 M
output
V
a
X2.1
X2.3
X2.2
X2.4
X2.6
X2.5
X2.7
X2.8
X2.9
X2.10 M
+2V
+1V
+0,5V
+1V
+0,5V
+0,2V
+0,2V
+0,1V
+320s
+160s
+ 80s
+ 40s
+ 20s
+ 10s
Bat
24V DC o.k.
Batt. o.k. Ba<85%
optional USB
for 6EP1931-2DC42
and 6EP1931-2EC42
serial
interface
only 6EP1931-2DC31
and 6EP1931-2EC31
power
supply
battery
power stack
load
charging current *
1
set time/max. time
disconnect V
a
green yellow green red
monitoring/control
operating elements
*1: charging current 0.2 A or 0.4 A for 6EP1931-2DC../0.35 A or 0.7 A for 6EP1931-2EC..
readiness to buffer
charge <85%
operating state battery
On/Off
opperating state battery
On/Off
buffering time
cut-in threshold
SITOP
alarm
G_KT01_EN_00226
alarm
end-of-charge
voltage
+22V fixed
+26.3V fixed
DC UPS module
KT10_EN_gesamt.book Seite 11 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
Overview
12/12
Siemens KT 10.1 2012
12
Function
The following timing diagrams show examples of the characteristic of the input and output voltage at the terminals of the DC UPS
module as well as the signal characteristic of the signals (relays) and of the remote signal (port).
"Long" power failure with DC UPS without serial or USB port
(Fig. 12/1)
Power restoration only once buffer time tp has expired
(t3 follows t4):
Upon failure of the input voltage on the DC UPS module (time t1),
the battery "Bat" immediately takes over the DC supply, and the
output voltage V
out
is then retained absolutely without
interruption.
The isolated changeover contact "OK/Bat" switches over to its off
position "Bat".
At the same point in time t1, the buffer time tp set on the DIP
switches is started automatically.
The fact that the DIP switch is set to "Interruption output V
out
" in
this example has no effect because the input voltage returns at
time t3 only once the set buffer time (time t4) has expired.
"Short" power failure with DC UPS without serial or USB port
(Fig. 12/2)
Power restoration before buffer time tp has expired (t3 before t4):
Upon failure of the input voltage on the DC UPS module (time t1),
the battery "Bat" immediately takes over the DC supply, and the
output voltage V
out
is then retained absolutely without
interruption.
The isolated changeover contact "OK/Bat" switches over to its off
position "Bat".
At the same point in time t1, the buffer time tp set on the DIP
switches is started automatically.
With the DIP switch set to "Interruption output V
out
", the output
voltage V
out
is automatically interrupted for 5 s once the set buffer
time tp (time t4) has expired.
The battery has already been disconnected because the input
voltage has returned at the time t3.
If the DIP switch is not set to "Interruption output V
out
", there is no
interruption in this example because the input voltage has
already returned at time t3 prior to expiry of the set buffer time
(time t4).
Figure 12/1 "Long power failure" Figure 12/2 "Short power failure"
DC UPS without serial or USB port (6EP1931-2DC21/-2EC21/-2FC21)
DIP switch settings on device: buffer time tp (from 5 s to 635 s with bottom row nos. 2 to 7) /
/ t = according to setting (with bottom row no. 1 to left) / = with setting for interruption V
out
(with bottom row no. 8 to left)
Legend:
V
in
V
out
ok
Bat
t1 t4 t3
(t4 - t1 = tp)
G_KT01_XX_00220
V
in
V
out
ok
Bat
t1 t3 t4 t5
(t4 - t1 = tp) (t5 - t4 = 5 s)
V
in
: Input voltage at terminals X1.1 X1.2
V
out
: Output voltage at terminals X1.3 X1.4 and X1.5 - X1.6
ok: Signal for input voltage V
in
OK or above the set battery
connection threshold
Bat: Signal for battery operation (batteries connected to output,
batteries supply the load)
Remote: Signal for remote timer start with signal level = 0 at pin 7 of
9-pin serial interface (pin 7 is usually the positive power
supply for the interface)
t1: Input voltage V
in
missing or falls below the set connection
threshold
t2: Buffer time set on DIP switches is started by remote timer
start (signal level = 0)
t3: Input voltage V
in
rises above set connection threshold
t4: End of set buffer time (output is switched off and/or battery
is disconnected)
t5: Output is connected again 5 s after shutdown
tp: Buffer time set on the DIP switches (bottom row nos. 2 to 7)
KT10_EN_gesamt.book Seite 12 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
Overview
12/13
Siemens KT 10.1 2012
12
Function (continued)
"Long" power failure with DC UPS with serial or USB port
(Fig. 12/3)
Power restoration only once buffer time tp
(t3 follows t4) has expired:
Upon failure of the input voltage on the DC UPS module (time t1),
the battery "Bat" immediately takes over the DC supply, and the
output voltage V
out
is then retained absolutely without
interruption.
The isolated changeover contact "OK/Bat" switches over to its off
position "Bat".
The buffer time tp set on the DIP switches is started at the user-
selectable time t2 by means of the signal "Remote timer start"
(signal level = 0 at pin 7 of the 9-pin serial port following previous
signal chart according to operating instructions).
The fact that the DIP switch is set to "Interruption output V
out
" in
this example has no effect because the input voltage returns at
time t3 only once the set buffer time (time t4) has expired.
Note: Without a remote signal level = 0 with a setting t = max.
duration, there is no interruption to the output voltage in this case
because the set buffer time is not started (or interruption only if
the exhaustive discharge protection disconnects the
accumulator and the input voltage has not returned by then).
"Short" power failure with DC UPS with serial or USB port
(Fig. 12/4)
Power restoration before buffer time tp
(t3 before t4) has expired:
Upon failure of the input voltage on the DC UPS module (time t1),
the battery "Bat" immediately takes over the DC supply, and the
output voltage V
out
is then retained absolutely without
interruption.
The isolated changeover contact "OK/Bat" switches over to its off
position "Bat".
The buffer time tp set on the DIP switches is started at the user-
selectable time t2 by means of the signal "Remote timer start"
(signal level = 0 at pin 7 of the 9-pin serial port following previous
signal chart according to operating instructions).
With the DIP switch set to "Interruption output V
out
", the output
voltage V
out
is automatically interrupted for 5 s once the set buffer
time tp (time t4) has expired.
The battery has already been disconnected because the input
voltage has returned at the time t3.
The interruption to the output voltage V
out
for 5 s permits an
automatic restart for many industrial PCs, even if the line voltage
(or the input voltage V
in
on the DC UPS module) returns during
shutdown of the PC, as in this example.
Note: Without a remote signal level=0 with a setting t = max.
duration, there is no interruption in the output voltage here
because the set buffer time is not started.
Figure 12/3 "Long power failure" Figure 12/4 "Short power failure"
DC UPS with serial or USB port (6EP1931-2DC31/-2DC42/-2EC31/-2EC42/-2FC42)
DIP switch settings on device: buffer time tp (from 5 s to 635 s with bottom row nos. 2 to 7) /
/ t = max. time (with bottom row no. 1 to right) / interruption of V
out
(with bottom row no. 8 to left)
Legend:
V
in
V
out
ok
Bat
Remote
t1 t2 t4 t3
(t4 - t2 = tp)
G_KT01_XX_00222
V
in
V
out
ok
Bat
Remote
t1 t2 t4 t5 t3
(t4 - t2 = tp) (t5 - t4 = 5 s)
G_KT01_XX_00223
V
in
: Input voltage at terminals X1.1 X1.2
V
out
: Output voltage at terminals X1.3 X1.4 and X1.5 - X1.6
ok: Signal for input voltage V
in
OK or above the set battery
connection threshold
Bat: Signal for battery operation (batteries connected to output,
batteries supply the load)
Remote: Signal for remote timer start with signal level = 0 at pin 7 of
9-pin serial interface (pin 7 is usually the positive power
supply for the interface)
t1: Input voltage V
in
missing or falls below the set connection
threshold
t2: Buffer time set on DIP switches is started by remote timer
start (signal level = 0)
t3: Input voltage V
in
rises above set connection threshold
t4: End of set buffer time (output is switched off and/or battery
is disconnected)
t5: Output is connected again 5 s after shutdown
tp: Buffer time set on the DIP switches (bottom row nos. 2 to 7)
KT10_EN_gesamt.book Seite 13 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
DC UPS modules 6 A, 15 A, 40 A
12/14
Siemens KT 10.1 2012
12
Overview
Technical specifications
1)
SIPLUS modules see page 15/4.
2)
All SITOP 24 V DC power supplies are permissible without restriction.
3)
In order to implement more than 30 A up to max. 40 A output current for the DC-UPS module 40 A, two 7 Ah or 12 Ah battery modules connected in parallel
are required.
Product DC UPS module DC UPS module DC UPS module
Power supply, type 6 A 15 A 40 A
Order No. 6EP1 931-2DC21
6EP1 931-2DC31
(with serial interface)
6EP1 931-2DC42
(with USB interface)
6EP1 931-2EC21
1)
6EP1 931-2EC31
(with serial interface)
6EP1 931-2EC42
(with USB interface)
6EP1 931-2FC21
1)
6EP1 931-2FC42
(with USB interface)
Product DC UPS module DC UPS module DC UPS module
Power supply, type 6 A 15 A 40 A
Input L+/M in normal operation
Controlled DC voltage Controlled DC voltage Controlled DC voltage
Rated voltage value V
in rated
2)
24 V DC 24 V DC 24 V DC
Voltage range 22 ... 29 V DC 22 ... 29 V DC 22 ... 29 V DC
Connection threshold for battery 22.5 V DC 0.1 V (factory setting),
adjustable in the range 22 to
25.5 V DC
(in 0.5 V increments)
22.5 V DC 0.1 V (factory setting),
adjustable in the range 22 to
25.5 V DC
(in 0.5 V increments)
22.5 V DC 0.1 V (factory setting),
adjustable in the range 22 to
25.5 V DC
(in 0.5 V increments)
Rated current value I
in rated
6 A + approx. 0.6 A with empty
battery
15 A +approx. 1 A with empty
battery
40 A + approx. 2.6 A with empty
battery
Mains buffering
Mains buffering or
buffer time
Dependent on connected battery and load current, see selection table battery module and mains buffering
times as well as the relevant important information notes!
On/off control circuit External isolated NO contact required (max. load 15 V DC / max. 10 mA).
With an open control circuit, the battery is isolated from output L+, thus canceling mains buffering. If there is no
input voltage, a quiescent current of approximately 0.3 mA is drawn from the battery disconnected from the
output.
Methods of setting
the buffering time
Adjustable using DIP switches to a maximum buffering time up to forced shutdown due to exhaustive discharge
protection (at approx. 19 V) or to a time limit of 5 ... 635 s (in 10 s steps)
Interruption Adjustable using DIP switch, either:
Interruption in output voltage despite returning input voltage for min. 5 s following expiry of set buffer time to
support automatic restarting of industrial PCs or
No forced interruption on expiry of the set buffer time
Output L+/M in normal operation
Rated voltage V
out rated
24 V DC (output voltage of SITOP
power supply)
24 V DC (output voltage of SITOP
power supply)
24 V DC (output voltage of SITOP
power supply)
Voltage range Input voltage V
in
less approx.
0.5 V DC
Input voltage V
in
less approx.
0.5 V DC
Input voltage V
in
less approx.
0.5 V DC
Startup delay Approx. 1 s Approx. 1 s Approx. 1 s
Voltage rise Typ. 60 ms Typ. 60 ms Typ. 360 ms
Output current I
out
0 ... 6 A 0 ... 15 A 0 ... 40 A
Dynamic current with overload Electronic current limitation to 1.05 ... 1.4 I
out rated
for approx. 80 ms, then electronic shutdown of the output
with automatic restart attempts (approx. 20 s intervals between restart attempts)
Dynamic current with short-circuit Electronic current limitation to1.5... 3 I
out rated
for approx.20 ms, then electronic shutdown of the output with
automatic restart attempts (approx. 20 s intervals between restart attempts)
Output L+/M with battery operation
Rated voltage V
out rated
24 V DC (from battery module) 24 V DC (from battery module) 24 V DC (from battery module)
Approximate voltage range 27 ... 19 V DC at I
out
= 0.05 C 1/h or 24 V at I
out
= 1 C 1/h or 23 V at I
out
= 2 C 1/h
(C = total connected battery capacity in Ah), 19 V switch-off threshold for deep discharge protection
Output current I
out
3)
0 ... 6 A (permanently permissible) 0 ... 15 A (permanently
permissible)
0 ... 40 A (permanently
permissible)
Dynamic current with overload Electronic current limitation to 1.05 ... 1.4 I
out rated
for approx. 80 ms, then latching switch-off of
output (restart following return to normal operation)
Dynamic current with short-circuit Electronic current limitation to 1.5 ... 3 I
out rated
for approx. 20 ms, then latching switch-off of
output (restart following return to normal operation)
KT10_EN_gesamt.book Seite 14 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
DC UPS modules 6 A, 15 A, 40 A
12/15
Siemens KT 10.1 2012
12
Technical specifications (continued).
4)
Permissible contact rating: 60 V DC/1 A or 30 V AC/1 A.
5)
"24 V DC OK" means: Voltage of the power supply unit is greater than the battery connection threshold set on the DC UPS module.
Product DC UPS module DC UPS module DC UPS module
Power supply, type 6 A 15 A 40 A
Order No. 6EP1 931-2DC21
6EP1 931-2DC31
(with serial interface)
6EP1 931-2DC42
(with USB interface)
6EP1 931-2EC21
1)
6EP1 931-2EC31
(with serial interface)
6EP1 931-2EC42
(with USB interface)
6EP1 931-2FC21
6EP1 931-2FC42
(with USB interface)
Output + Bat / Bat in normal operation
Output +Bat/-Bat
in normal operation
I-V charging characteristic
(first constant current I,
then constant voltage V)
I-V charging characteristic
(first constant current I,
then constant voltage V)
I-V charging characteristic
(first constant current I,
then constant voltage V)
End-of-charge voltage V 26.6 V DC 0.1 V (factory setting
for +40 C battery temperature),
adjustable in the range
26.3 to 29.3 V (in 0.1 V
increments)
26.6 V DC 0.1 V (factory setting
for +40 C battery temperature),
adjustable in the range
26.3 to 29.3 V (in 0.1 V
increments)
26.6 V DC 0.1 V (factory setting
for +40 C battery temperature),
adjustable in the range
26.3 to 29.3 V (in 0.1 V
increments)
Charging current I Approx. 0.4 A (factory setting),
adjustable to 0.2 A or 0.4 A
(charging is carried out with
closed and open on/off circuit)
At a battery voltage of < 6 V
(batteries defective), charging is
not carried out as a protective
measure.
Approx. 0.7 A (factory setting),
adjustable to 0.35 A or 0.7 A
(charging is carried out with
closed and open on/off circuit)
At a battery voltage of < 6 V
(batteries defective), charging is
not carried out as a protective
measure.
Approx. 2 A (factory setting),
adjustable to 1 A or 2 A
(charging is carried out with
closed and open on/off circuit)
At a battery voltage of < 6 V
(batteries defective), charging is
not carried out as a protective
measure.
Efficiency/heat loss
At V
out rated
, I
out rated
approx. 95 % / 7 W 96.2 % / 14 W 97.2 % / 28.6 W
With battery operation, approx. 94.5 % / 8 W 96 % / 15 W 96V
in
% / 33.6 W
Protection and monitoring
Reverse polarity protection Against polarity reversal on input
voltage and batteries
Against polarity reversal on input
voltage and batteries
Against polarity reversal on input
voltage and batteries
Overload protection In accordance with "dynamic current with overload" in normal operation (automatic restart attempts) or in battery
mode (restart following return to normal operation)
Short-circuit protection In accordance with "dynamic current with short-circuit" in normal operation (automatic restart attempts)
or in battery mode (restart following return to normal operation). Built-in (not accessible) 16 A fuse
(6 A and 15 A on DC UPS module) or 64 A fuse (40 A on DC UPS module).
Exhaustive discharge protection Automatic shutdown when battery voltage falls below approx. 19 V.
At a battery voltage of < 6 V (batteries defective), charging is not carried out as a protective measure.
Monitoring
"Wire breakage in battery circuit"
Alarm signal if battery circuit not closed or if it opens during operation
(cyclic test approximately every 20 s)
Monitoring
"Battery replacement required"
Alarm signal flashing at approx.
0.25 Hz repetition frequency
(approx. 2 s alarm, approx. 2 s no
alarm, approx. 2 s alarm, etc.).
Check every 4 hours with
6 ohm load for 1 s if no buffer
mode or switch-off has taken
place within 4 hours.
Alarm signal flashing at approx.
0.25 Hz repetition frequency
(approx. 2 s alarm, approx. 2 s no
alarm, approx. 2 s alarm, etc.).
Check every 4 hours with
3 ohm load for 1 s if no buffer
mode or switch-off has taken
place within 4 hours.
Alarm signal flashing at approx.
0.25 Hz repetition frequency
(approx. 2 s alarm, approx. 2 s
no alarm, approx. 2 s alarm, etc.).
Check every 4 hours with
1 ohm load for 1 s if no buffer
mode or switch-off has taken
place within 4 hours.
No monitoring if switch position of
compatibility switch is "On"!
Monitoring "Battery charge > 85 %" Indication whether batteries are charged to at least 85 % of residual capacity still available depending on aging
Signaling
4)
Normal operation Green LED (OK) and isolated changeover contact "24 V DC OK / Bat" at setting "24 V DC OK"
5)
Buffer or battery mode (battery
supplies load alone or in addition to
PS in the case of overload)
Yellow LED (Bat) and isolated changeover contact "24 V DC OK / Bat" at setting "Bat" (= de-energized position)
Alarm (buffer not ready
or pre-warning from < 20.4 V
battery voltage)
Red LED (Alarm) and isolated changeover contact at setting "Alarm" (= de-energized position).
Causes of the buffer not being ready during normal operation can include: Off status or open on/off control circuit,
battery module not connected, polarity reversal or defective battery (battery voltage< 18.5 V) or wire breakage
between battery and UPS module. Scanning and thus updating of the signal every 20 s.
Causes of the buffer not being available during buffer operation can include: Accumulator voltage has dropped
below 20.4 V DC (= pre-warning before shutdown through exhaustive discharge protection) and shutdown of the
accumulator due to overload, short-circuit, exhaustive discharge protection or expired buffer time. The red LED
then goes out.
"Battery replacement required" Red LED (alarm) flashing at 0.25 Hz and floating changeover contact (alarm) switching at approx. 0.25 Hz
"Battery charge > 85 %" Second green LED (Bat > 85 %) and floating NO contact closed (de-energized position = open)
KT10_EN_gesamt.book Seite 15 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
DC UPS modules 6 A, 15 A, 40 A
12/16
Siemens KT 10.1 2012
12
Technical specifications (continued)
Product DC UPS module DC UPS module DC UPS module
6 A 15 A 40 A
Power supply, type 6EP1 931-2DC21
6EP1 931-2DC31
(with serial interface)
6EP1 931-2DC42
(with USB interface)
6EP1 931-2EC21
1)
6EP1 931-2EC31
(with serial interface)
6EP1 931-2EC42
(with USB interface)
6EP1 931-2FC21
6EP1 931-2FC42
(with USB interface)
Order No. 6 A 15 A 40 A
Signaling
4)
Compatibility switch Only on 6EP1 931-2FC21
The following can be selected using DIP switches: Switch position "Off" - "significant properties analogous to new
DC UPS range" or "On" switch position - "analogous to previous DC UPS module 40 (6EP1931-2FC01)".
With compatibility switch in "On" position:
Output of the Alarm signal changes: - The red LED flashes on wire-break between rechargeable battery and
UPS DC module with
1
/
3
Hz and isolated changeover contact (alarm) switching at approx.
1
/
3
Hz.
A battery test does not take place.
Optional port and software
Serial interface Only on 6EP1 931-2.C31
Output of all alarm signals and receipt of the "Remote timer start" signal. Technical design: PC-compatible. 8N1
send and receive,
9600 baud, 8 data bits, 1 stop bit, no parity bit. Required connection to the PC: 1 : 1 interconnected 9-pole sub
D extension cable (connector/socket); only pin 2 (RXD), pin 3 (TDX) and pin 7 (RTS) are required.
USB interface Only on 6EP1 931-2.C42
Output of all alarm signals and receipt of the "Remote timer start" signal. Technical design: Specification 2.0 with
full speed, i.e. 2 Mbit/s. Supplied with +5 V by DC UPS ("self powered"). Required connection to the PC:
Commercially available 4-core shielded cable, 90 ohm, max. 5 m, USB series "A" connector to PC and USB
series "B" connector to DC UPS
Software A software tool for reading out and processing the signals (can run under Windows 2000, Windows XP, Windows
Vista and Windows 7) is available for downloading from the Internet at https://www.siemens.com/sitop-ups. This
site also provides more information on the interface.
Control signals
On/off control signal Buffering is terminated or the battery is disconnected from the output by opening the control circuit or by means
of DIP switches on the device (DIP switch must be in "Off" position). All other functions are retained.
"Remote Timer start" via serial
interface or USB
Starts mains buffering for the set
buffer time
Starts mains buffering for the set
buffer time
Starts mains buffering for the set
buffer time
Safety
Primary/secondary isolation No No No
Protection class Class III (ext. circuit and power-
supply unit: SELV in accordance
with EN 60950 required)
Class III (ext. circuit and power-
supply unit: SELV in accordance
with EN 60950 required)
Class III (ext. circuit and power-
supply unit: SELV in accordance
with EN 60950 required)
EMC
Emitted interference according to EN 55022. Class B according to EN 55022. Class B according to EN 55022. Class B
Noise immunity according to EN 61000-6-2 according to EN 61000-6-2 according to EN 61000-6-2
Ambient conditions
Ambient temperature during
operation
-25 ... +60 C with natural
convection
-25 ... +60 C with natural
convection
-25 ... +60 C with natural
convection
Transport/storage temperature -40 ... +85 C -40 ... +85 C - 40 ... +85 C
Degree of protection (EN 60529) IP20 IP20 IP20
Humidity class Conditions of use in accordance
with EN 60721, climate class 3K3
(relative humidity 5 % to 85 % and
absolute humidity
1 g/m
3
to 25 g/m
3
; no
condensation)
Conditions of use in accordance
with EN 60721, climate class 3K3
(relative humidity 5 % to 85 % and
absolute humidity
1 g/m
3
to 25 g/m
3
; no
condensation)
Conditions of use in accordance
with EN 60721, climate class 3K3
(relative humidity 5 % to 85 % and
absolute humidity
1 g/m
3
to 25 g/m
3
; no
condensation)
KT10_EN_gesamt.book Seite 16 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
DC UPS modules 6 A, 15 A, 40 A
12/17
Siemens KT 10.1 2012
12
Technical specifications (continued)
Product DC UPS module DC UPS module DC UPS module
6 A 15 A 40 A
Power supply, type 6EP1 931-2DC21
6EP1 931-2DC31
(with serial interface)
6EP1 931-2DC42
(with USB interface)
6EP1 931-2EC21
1))
6EP1 931-2EC31
(with serial interface)
6EP1 931-2EC42
(with USB interface)
6EP1 931-2FC21
6EP1 931-2FC42
(with USB interface)
Order No. 6 A 15 A 40 A
Approvals
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2
No.107.1), File E197259
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259
Mechanics
Input connections 24 V DC 2 screw terminals
for 1 ... 4 mm
2
/17 ... 11 AWG
2 screw terminals
for 1 ... 4 mm
2
/17 ... 11 AWG
2 screw terminals for
0.33 ... 10 mm
2
/22 ... 7 AWG
Output connections 24 V DC 4 screw terminals for
1 ... 4 mm
2
/17 ... 11 AWG
4 screw terminals for
1 ... 4 mm
2
/17 ... 11 AWG
4 screw terminals for
0.33 ... 10 mm
2
/22 ... 7 AWG
Connections for rechargeable
battery 24 V DC
2 screw terminals
for 1 ... 4 mm
2
/17 ... 11 AWG
2 screw terminals
for 1 ... 4 mm
2
/17 ... 11 AWG
2 screw terminals for
0.33 ... 10 mm
2
/22 ... 7 AWG
Connections for control circuit and
alarm signals
10 screw terminals for
0.5 ... 2.5 mm
2
/20 ... 13 AWG
10 screw terminals for
0.5 ... 2.5 mm
2
/20 ... 13 AWG
10 screw terminals for
0.5 ... 2.5 mm
2
/20 ... 13 AWG
Dimensions (W H D) in mm 50 125 approx. 125 50 125 approx. 125 102 125 125
Weight, approx. 0.4 kg (with serial or USB
interface: 0.45 kg)
0.4 kg (with serial or USB
interface: 0.45 kg)
1.1 kg (with serial or USB
interface: 1.1 kg)
Installation Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 17 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Battery modules
12/18
Siemens KT 10.1 2012
12
Overview
Technical specifications
1)
For storage, mounting and operation of lead-acid batteries, the relevant DIN/VDE regulations or country-specific regulations
(e.g. VDE 0510 Part 2/EN 50272-2) must be observed. You must ensure that the battery site is sufficiently ventilated. Possible sources of ignition must be at
least 50 cm away.
Product Battery module 1.2 Ah Battery module 2.5 Ah Battery module 3.2 Ah
Battery type Maintenance-free
lead-acid batteries
Maintenance-free
pure lead batteries
Maintenance-free, sealed lead-
acid batteries
Order No. 6EP1 935-6MC01 6EP1 935-6MD31 6EP1 935-6MD11
Battery module for DC UPS
module 6 A
It has two maintenance-free,
closed lead-acid batteries (from
the same lot) which are installed in
a holder and connected in series
with corrosion-resistant lead-cal-
cium high-performance grid
plates and glass fiber.
Completely prewired with battery
retainer and terminals
Low self-discharge rate of
approximately 3 % per month
(at +20 C)
High-temperature battery module
for DC UPS module 6 A and
15 A
It has two maintenance-free,
closed pure lead-acid batteries
(from the same lot), which are
installed in a holder and
connected in series.
Completely prewired with battery
retainer and terminals
Low self-discharge rate of
approximately 3 % per month
(at +20 C)
Battery module for DC UPS
module 6 A and 15 A
It has two maintenance-free,
closed lead-acid batteries (from
the same lot) which are installed in
a holder and connected in series
with corrosion-resistant lead-cal-
cium high-performance grid
plates and glass fiber.
Complete with battery retainer and
terminals
Low self-discharge rate of
approximately 3 % per month
(at +20 C)
Product Battery module 1.2 Ah Battery module 2.5 Ah Battery module 3.2 Ah
Battery type Maintenance-free
lead-acid batteries
Maintenance-free
pure lead batteries
Maintenance-free, sealed lead-
acid batteries
Order No. 6EP1 935-6MC01 6EP1 935-6MD31 6EP1 935-6MD11
Charging current/charging voltage
Maintenance-free, sealed lead-
acid batteries
Maintenance-free
pure lead-acid batteries
Maintenance-free, sealed lead-
acid batteries
Recommended end-of-charge
voltage (stand-by use), dependent
on battery temperature
27.8 V at +10 C
27.3 V at +20 C
26.8 V at +30 C
26.6 V at +40 C
29.0 V at 10 C
28.6 V at 0 C
28.3 V at +10 C
27.9 V at +20 C
27.5 V at +30 C
27.2 V at +40 C
26.8 V at +50 C
26.4 V at +60 C
27.8 V at +10 C
27.3 V at +20 C
26.8 V at +30 C
26.6 V at +40 C
Recommended charging current Max. 0.3 A Max. 5 A Max. 0.8 A
Protection
Short-circuit protection Battery fuse 7.5 A/32 V
(solid-state circuitry blade-type
fuse + support)
Battery fuse 15 A/32 V
(solid-state circuitry blade-type
fuse + support)
Battery fuse 15 A/32 V
(solid-state circuitry blade-type
fuse + support)
Battery protection Valve control Valve control Valve control
Safety
Protection class Class III Class III Class III
UL/cUL (CSA) approval cURus-recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
cURus-recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
cURus-recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
Degree of protection (EN 60529) IP00 IP00 IP00
Operating data
1)
Ambient temperature range 0 ... +40 C -40 ... +60 C with natural
convection
0 ... +40 C with natural
convection
Transport/storage temperature
range
-20 ... +50 C -40 ... +60 C - 20 ... +50 C
Self-discharge rate Approx. 3 % per month at 20 C
battery temperature (increases
with temperature)
Approx. 3 % per month at 20 C
battery temperature (increases
with temperature)
Approx. 3 % per month at 20 C
battery temperature (increases
with temperature)
KT10_EN_gesamt.book Seite 18 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Battery modules
12/19
Siemens KT 10.1 2012
12
Battery module 7 Ah Battery module 12 Ah
Maintenance-free, sealed lead-
acid batteries
Maintenance-free, sealed lead-
acid batteries
6EP1 935-6ME21 6EP1 935-6MF01
Battery module for DC UPS
module 6 A, 15 A, and 40 A
(for > 20 to 40 A, 2 modules are
required in parallel).
It has two maintenance-free,
closed lead-acid batteries (from
the same lot) which are installed in
a holder and connected in series
with corrosion-resistant lead-cal-
cium high-performance grid
plates and glass fiber.
Completely pre-wired with termi-
nals and battery retainer
Low self-discharge rate of
approximately 3 % per month
(at +20 C)
Battery module for DC UPS
module 6 A and 15 A and
DC UPS module 40 A (for > 20 to
40 A, 2 modules are required in
parallel)
It has two maintenance-free,
closed lead-acid batteries (from
the same lot) which are installed in
a holder and connected in series
with corrosion-resistant lead-cal-
cium high-performance grid
plates and glass fiber.
Completely pre-wired with
terminals and battery retainer
Low self-discharge rate of
approximately 3 % per month
(at +20 C).
Battery module 7 Ah Battery module 12 Ah
Maintenance-free, sealed lead-
acid batteries
Maintenance-free, sealed lead-
acid batteries
6EP1 935-6ME21 6EP1 935-6MF01
Maintenance-free, sealed lead-
acid batteries
Maintenance-free, closed lead-
acid batteries
27.8 V at +10 C
27.3 V at +20 C
26.8 V at +30 C
26.6 V at +40 C
27.8 V at +10 C
27.3 V at +20 C
26.8 V at +30 C
26.6 V at +40 C
Max. 1.75 A Max. 3 A
Battery fuse 30 A/32 V
(solid-state circuitry blade-type
fuse + support)
Battery fuse 30 A/32 V
(solid-state circuitry blade-type
fuse + support)
Valve control Valve control
Class III Class III
UL/cUL-Recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
cURus-recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
IP00 IP00
0 ... +40 C 0 ... +40 C
20 ... +50 C 20 ... +50 C
Approx. 3 % per month at 20 C
battery temperature
Approx. 3 % per month at 20 C
battery temperature
KT10_EN_gesamt.book Seite 19 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Battery modules
12/20
Siemens KT 10.1 2012
12
Technical specifications (continued)
.
1)
Along with the storage and operating temperature, other factors such as the duration of the storage period and the charge status during storage have a
decisive influence on the possible useful life. Batteries should therefore be stored as briefly as possible, always fully charged, and within the temperature
range 0 to +20 C.
Product Battery module 1.2 Ah Battery module 2.5 Ah Battery module 3.2 Ah
Battery type Maintenance-free
lead-acid batteries
Maintenance-free
pure lead batteries
Maintenance-free, sealed lead-
acid batteries
Order No. 6EP1 935-6MC01 6EP1 935-6MD31 6EP1 935-6MD11
Battery life
1)
The service life of the lead-acid
batteries (when capacity falls to
50 % of original capacity) depends
on the battery temperature as
follows:
Approx. 4 years at +20 C
Approx. 2 years at +30 C
Approx. 1 year at +40 C
Approx. >10 years at +20 C
Approx. 7 years at +30 C
Approx. 3 years at +40 C
Approx. 1.5 years at +50 C
Approx. 1 year at +60 C
Approx. 4 years at +20 C
Approx. 2 years at +30 C
Approx. 1 year at +40 C
Mechanics
Connection 1 screw terminal each for
0.08 to 2.5 mm
2
for +BAT
and BAT
1 screw terminal each for
0.08 to 2.5 mm
2
for +BAT
and BAT
1 screw terminal each for
0.08 to 2.5 mm
2
for +BAT
and BAT
Accessories, included Accessories pack with solid-state
circuitry fuse 7.5 A
Accessories pack with solid-state
circuitry fuse 15 A
Accessories pack with solid-state
circuitry fuse 15 A
Dimensions (W H D) in mm 96 106 108 265 151 91 190 151 82
Weight, approx. 1.8 kg 3.8 kg 3.2 kg
Installation Snaps onto DIN rail
EN 60715 357.5/15 or keyhole
mounting for hooking in to M4
screws
Snaps onto DIN rail
EN 60715 357.5/15 or keyhole
mounting for hooking in to M4
screws
Snaps onto DIN rail
EN 60715 357.5/15 or keyhole
mounting for hooking in to M4
screws
KT10_EN_gesamt.book Seite 20 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Battery modules
12/21
Siemens KT 10.1 2012
12
Battery module 7 Ah Battery module 12 Ah
Maintenance-free, sealed lead-
acid batteries
Maintenance-free, sealed lead-
acid batteries
6EP1 935-6ME21 6EP1 935-6MF01
Approx. 4 years at +20 C
Approx. 2 years at +30 C
Approx. 1 year at +40 C
Approx. 4 years at +20 C
Approx. 2 years at +30 C
Approx. 1 year at +40 C
1 screw terminal each for
0.08 to 4 mm
2
for +BAT
and BAT
1 screw terminal each for
0.08 to 4 mm
2
for +BAT
and BAT
Accessories pack with spare
solid-state circuitry fuse 15 A and
30 A
Accessories pack with spare
solid-state circuitry fuse 15 A and
30 A
186 168 121 253 168 121
6.0 kg 9.0 kg
Can be screwed onto flat surface
("keyhole mounting" for hooking
onto M4 screws)
Can be screwed onto flat surface
("keyhole mounting" for hooking
onto M4 screws)
KT10_EN_gesamt.book Seite 21 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS
12/22
Siemens KT 10.1 2012
12
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Product Input Output; Energy Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP UPS500S
24 V DC 24 V DC; 2.5 kWs 15 A 6EP1 933-2EC41
24 V DC 24 V DC; 5 kWs 15 A 6EP1 933-2EC51
SITOP UPS501S
24 V DC 24 V DC; 5 kWs 15 A 6EP1 935-5PG01
SITOP UPS500P
24 V DC 24 V DC; 5 kWs 7 A 6EP1 933-2NC01
24 V DC 24 V DC; 10 kWs 7 A 6EP1 933-2NC11
Connector set
Connector set with connector for input and output with
pre-assembled USB cable (2 m long)
6EP1 975-2ES00
DC UPS module
24 V DC 24 V DC 6 A 6EP1 931-2DC21
24 V DC 24 V DC,
with serial interface
6 A 6EP1 931-2DC31
24 V DC 24 V DC,
with USB interface
6 A 6EP1 931-2DC42
24 V DC 24 V DC 15 A 6EP1 931-2EC21
24 V DC 24 V DC,
with serial interface
15 A 6EP1 931-2EC31
24 V DC 24 V DC,
with USB interface
15 A 6EP1 931-2EC42
24 V DC 24 V DC 40 A 6EP1 931-2FC21
24 V DC 24 V DC,
with USB interface
40 A 6EP1 931-2FC42
Battery modules
Capacity:
1.2 Ah 6EP1 935-6MC01
2.5 Ah, high-temperature battery module 6EP1 935-6MD31
3.2 Ah 6EP1 935-6MD11
7 Ah 6EP1 935-6ME21
12 Ah 6EP1 935-6MF01
KT10_EN_gesamt.book Seite 22 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
13
13/2 Output voltage 3-52 V
SITOP flexi
13/4 Output voltage 5 V
13/4 LOGO!Power 5 V/3 A
13/4 LOGO!Power 5 V/6.3 A
13/6 Output voltage 12 V
13/6 LOGO!Power 12 V/1.9 A
13/6 SITOP PSU100C 12 V/2 A
13/6 SITOP DC/12 V DC/2.5 A
13/7 PSU100D 12 V/3 A
13/7 LOGO!Power 12 V/4.5 A
13/7 SITOP PSU100C 12 V/6.5 A
13/10 PSU100D 12 V/8.3 A
13/10 SITOP PSU300B 12 V/20 A
13/12 Output voltage 15 V
13/12 LOGO!Power 15 V/1.9 A
13/12 LOGO!Power 15 V/4 A
13/12 SITOP dual 2 x 15 V/3.5 A
13/14 Output voltage 48 V
13/14 SITOP PSU300M 48 V/10 A
13/14 SITOP modular 48 V/20 A
13/16 Ordering data and additional
information
SITOP
Alternative voltages
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltages 3 - 52 V
13/2
Siemens KT 10.1 2012
13
Overview
Technical specifications
Product Special design
SITOP flexi
Power supply, type 3-52 V/2-10 A
Order No. 6EP1 353-2BA00
The power supply with flexible output voltage from
3 to 52 V; suitable for all application areas requiring a
special voltage other than 24 V.
Product Special design
SITOP flexi
Input
1-phase AC
Rated voltage value V
in rated
120/230 V AC
Set via wire jumper
Voltage range 85 ... 132 V/170 ... 264 V
Overvoltage resistance 2.3 V
in
rated
.1.3 ms
Mains buffering at I
out rated
> 10 ms at V
in
= 93/187 V
(P
a
= 120 W)
Rated line frequency value; range 50/60 Hz, 47 ... 63 Hz
Rated current I
in rated
2.2/0.9 A
Switch-on current limit (+25 C) < 32 A
I
2
t < 0.8 A
2
s
Built-in incoming fuse T 3.15 A/250 V (not accessible)
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
From 6 A, characteristic C
Output
Controlled, isolated DC voltage
Rated voltage V
out rated
3-52 V DC
Total tolerance 1 %
Static line compensation Approx. 0.1 %
Static load compensation Approx. 0.2 %
Sense line connection Yes, maximum voltage control 0.5 V per line
Residual ripple < 50 mV
pp
(typ. 20 mV
pp
)
Spikes (bandwidth: 20 MHz) < 100 mV
pp
(typ. 80 mV
pp
)
Adjustment range 3 ... 52 V, via potentiometer or analog control voltage signal 0 ... 2.5 V
Status display Green LED for 24 V OK
Signaling Power good via relay contact, current monitor signal 0 ... 2.5 V
On/off behavior No overshoot of V
out
(soft start)
Startup delay /
voltage rise
< 3 s/typ. 80 ms
Rated current value I
out rated
2 to 10 A (max. 120 W)
Current range
Up to +60 C 0 ... 10 A (max. 120 W)
Derating
Dynamic overcurrent on
Power-up on short-circuit Constant current 2 ... 10 A
Short circuit during operation Constant current 2 ... 10 A
Parallel switching for
enhanced performance
Yes, 2 units
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltages 3 - 52 V
13/3
Siemens KT 10.1 2012
13
Technical specifications (continued)
Product Special design
SITOP flexi
Power supply, type 3-52 V/2-10 A
Order No. 6EP1 353-2BA00
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 84 % (at 24 V/5 A)
Power loss at V
out rated
, I
out rated
Approx. 23 W (at 24 V/5 A)
Protection and monitoring
Output overvoltage protection Yes, according to EN 60950
Current limitation 2 ... 10 A, adjustable by potentiometer or with analog control voltage signal 0 ... 2.5 V
Short-circuit protection Electronic current limitation
(2 ... 10 A) in the range 3 ... 12 V or power limitation (120 W) in the range 12 ... 52 V
Sustained short-circuit current rms
value
matching the set current limitation 2 ...10 A
Overload/short-circuit indicator Red LED for current or power limiting
Safety
Primary/secondary isolation Yes, SELV output voltage V
out
according to EN 60950-1 and EN 50178
Protection class Class I
Leakage current < 3.5 mA
Safety test Yes
CE mark Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289
Degree of protection (EN 60529) IP20
EMC
Emitted interference EN 55022 Class B
Supply harmonics limitation EN 61000-3-2
Noise immunity EN 61000-6-2
Operating data
Permitted ambient temperature 0 ... +60 C with natural convection
Transport/storage temperature
range
-40 ... +85 C
Humidity class Climate class 3K3 according to EN 60721, no
condensation
Mechanics
Connections
Supply input L1, N, PE One screw-type terminal each for 0.5 mm to 2.5 mm
2
Output + 1 screw terminal for 0.5 ... 2.5 mm
2
(L+) und
Output - 2 screw-type terminals for 0.5 ... 2.5 mm
2
(M)
Alarm signals, control inputs Screw terminals for 0.14 ... 1.5 mm
2
Dimensions (W x H x D) in mm 75 125 125
Weight, approx. 0.9 kg
Installation Snaps onto DIN rail EN 60715 35x7.5/15
Accessories
Marine approval GL GL
X X
X X X X
X X
X X X X
X X
X X X X
X X
X X X X
X X X
X X X X X X
X X
X X
X X
X
X X X X
KT10_EN_gesamt.book Seite 19 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Standards and approvals
16/20
Siemens KT 10.1 2012
16
Overview of important standards and approvals
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
EN European standards
EN 50178 Electronic equipment for use in power installations
EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement
EN 60529 Degrees of protection provided by enclosures (IP-Code)
EN 60721 Classification of environmental conditions
EN 60950-1 Information technology equipment Safety
EN 61000-3-2 Electromagnetic compatibility (EMC) Part 3-2: Limits for harmonic current emissions (equipment input
current 16 A per phase)
EN 61000-6-2 Electromagnetic compatibility (EMC) Part 6-2: Generic standards Immunity for industrial environments
EN 61000-6-3 Electromagnetic compatibility (EMC) Part 6-3: Generic standards Emission standard for residential,
commercial and light industrial environments
UL Underwriters Laboratories
UL 508 Industrial control equipment
UL 1604 Electrical equipment for use in class I and class II, division 2. and class III hazardous (classified) locations
UL 1778 Uninterruptible power supply equipment
UL 2367 Standard for solid state overcurrent protectors
UL 60079 Electrical apparatus for explosive gas atmospheres
UL 60950 -1 Information technology equipment Safety
CSA Canadian Standards Association
CSA C22.2 No. 14 Industrial control equipment
CSA C22.2 No. 142 Process control equipment
CSA C22.2 No. 107.1 General use power supplies
CSA C22.2 No. 60079 Electrical apparatus for explosive gas atmospheres
CSA C22.2 No. 60950-1 Information technology equipment Safety
ATEX Equipment and protective systems intended for use in Potentially Explosive Atmospheres
FM Factory Mutual Research
ABS American Bureau of Shipping
GL Germanischer Lloyd
KT10_EN_gesamt.book Seite 20 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
17
17/2 Partners at
Industry Automation and
Drive Technologies
17/2 Contact partners worldwide
17/3 Siemens Solution Partners
17/4 Online Services
17/4 Information and ordering
in the Internet and on DVD
17/5 Service & Support
17/5 Services covering the entire life cycle
17/7 Knowledge Base on DVD
17/7 Automation Value Card
17/8 Alphabetical index
17/9 Order No. index
17/12 Terms and conditions of sale
and delivery
17/12 Export regulations
Appendix
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Partner at Industry Automation and Drive Technologies
17/2
Siemens KT 10.1 2012
17
At Siemens Industry Automation and Drive Technologies, more
than 85 000 people are resolutely pursuing the same goal: long-
term improvement of your competitive ability. We are committed
to this goal. Thanks to our commitment, we continue to set new
standards in automation and drive technology. In all industries
worldwide.
At your service locally, around the globe for consulting, sales,
training, service, support, spare parts ... on the entire Industry
Automation and Drive Technologies range.
Your personal contact can be found in our Contacts Database at:
www.siemens.com/automation/partner
You start by selecting a
Product group,
Country,
City,
Service.
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Partner at Industry Automation and Drive Technologies
Siemens Solution Partner Automation
17/3
Siemens KT 10.1 2012
17
Overview
Siemens Solution Partner Automation
Solution Partner: Highest quality - guaranteed
The products and systems from Siemens Industry Automation
and Drive Technologies offer the ideal platform for all automation
applications.
Under the name of Siemens Solution Partner Automation,
selected system integrators around the world act as uniformly
qualified solution providers for the Siemens range of products
and services in the fields of automation and drives. Day after
day, they utilize their qualified product and system know-how as
well as their excellent industry expertise to your advantage for
all requirements.
The partner emblem is the guarantee and indicator of proven
quality. The basis for this are defined quality features that identify
Solution Partners as reliable and competent solution providers:
Solution quality
Always a good result with tried and tested solutions expertise.
Expert quality
Certified technical competence ensures maximum efficiency.
Project quality
With proven project experience straight to the target.
Portfolio quality
Comprehensive portfolio for state-of-the-art solutions from a
single source.
Solution Partner Finder
The Siemens Solution Partner Program helps you to find the
optimum partner for your specific requirements.
Support is provided by the Solution Partner Finder, a compre-
hensive online platform that showcases the profiles of all our
solution partners. You can convince yourself of the competence
of the respective Solution Partner by means of the references
provided. Various search criteria are available for this purpose.
Once you have located a partner, you are only one small step
away from contacting them.
Find the right partner here for your specific task and convince
yourself of the solution competence provided:
https://www.siemens.com/automation/partnerfinder
Additional information on the Siemens Solution Partner Program
is available online at:
https://www.siemens.com/automation/solutionpartner
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Online Services
Information and Ordering
in the Internet and on DVD
17/4
Siemens KT 10.1 2012
17
Siemens Industry Automation and Drive Technologies in the WWW
A detailed knowledge of the range of products and services
available is essential when planning and configuring automation
systems. It goes without saying that this information must always
be fully up-to-date.
Siemens Industry Automation and Drive Technologies has
therefore built up a comprehensive range of information in the
World Wide Web, which offers quick and easy access to all data
required.
Under the address
www.siemens.com/industry
you will find everything you need to know about products, sys-
tems and services.
Product Selection Using the Interactive Catalog CA 01 of Industry
Detailed information together with convenient interactive
functions:
The interactive catalog CA 01 covers more than 80 000 products
and thus provides a full summary of the Siemens Industry Auto-
mation and Drive Technologies product base.
Here you will find everything that you need to solve tasks in the
fields of automation, switchgear, installation and drives.
All information is linked into a user interface which is easy to
work with and intuitive.
After selecting the product of your choice you can order at the
press of a button, by fax or by online link.
Information on the interactive catalog CA 01 can be found in the
Internet under
www.siemens.com/automation/ca01
or on DVD.
Easy Shopping with the Industry Mall
The Industry Mall is the virtual department store of Siemens AG
in the Internet. Here you have access to a huge range of prod-
ucts presented in electronic catalogs in an informative and at-
tractive way.
Data transfer via EDIFACT allows the whole procedure from
selection through ordering to tracking of the order to be carried
out online via the Internet.
Numerous functions are available to support you.
For example, powerful search functions make it easy to find the
required products, which can be immediately checked for avail-
ability. Customer-specific discounts and preparation of quotes
can be carried out online as well as order tracking and tracing.
Please visit the Industry Mall on the Internet under:
www.siemens.com/industrymall
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Service & Support
The unmatched complete service
for the entire life cycle
17/5
Siemens KT 10.1 2012
17
For machine constructors, solution providers and plant opera-
tors: The service offering from Siemens Industry, Automation and
Drive Technologies includes comprehensive services for a wide
range of different users in all sectors of the manufacturing and
process industry
To accompany our products and systems, we offer integrated
and structured services that provide valuable support in every
phase of the life cycle of your machine or plant - from planning
and implementation through commissioning as far as mainte-
nance and modernization.
Our Service & Support accompanies you worldwide in all mat-
ters concerning automation and drives from Siemens. We pro-
vide direct on-site support in more than 100 countries through all
phases of the life cycle of your machines and plants.
You have an experienced team of specialists at your side to pro-
vide active support and bundled know-how. Regular training
courses and intensive contact among our employees - even
across continents - ensure reliable service in the most diverse
areas.
Online Support
The comprehensive online infor-
mation platform supports you in
all aspects of our Service & Sup-
port at any time and from any lo-
cation in the world.
www.siemens.com/
automation/service&support
Technical Support
Expert advice on technical
questions with a wide range of
demand-optimized services for
all our products and systems.
www.siemens.com/
automation/support-request
Technical Consulting
Support in planning and design-
ing your project: From detailed
actual-state analysis, definition
of the goal and consulting on
product and system questions
right through to the creation of
the automation solution.
Training
Extend your competitive edge -
through practical know-how
directly from the manufacturer.
www.siemens.com/sitrain
S
p
a
r
e
P
a
r
t
s
S
p
a
r
e
P
a
r
t
s
T
e
c
h
n
ic
a
l
S
u
p
p
o
r
t
Technical
Consulting
Technical
Consulting
T
e
c
h
n
ic
a
l
S
u
p
p
o
r
t
Service
Programs
Service
Programs
Engineering
Support
Engineering
Support
Training Training
Modernization
Services
Modernization
Services
O
n
lin
e
S
u
p
p
o
r
t
O
n
lin
e
S
u
p
p
o
r
t
F
i
e
l
d
S
e
r
v
i
c
e
F
i
e
l
d
S
e
r
v
i
c
e
Optimization
Services
Optimization
Services
Contact information is available in the Internet at:
www.siemens.com/automation/partner
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Service & Support
The unmatched complete service
for the entire life cycle
17/6
Siemens KT 10.1 2012
17
Engineering Support
Support during project engi-
neering and development with
services fine-tuned to your re-
quirements, from configuration
through to implementation of an
automation project.
Field Service
Our Field Service offers you ser-
vices for commissioning and
maintenance - to ensure that
your machines and plants are
always available.
Spare parts
In every sector worldwide,
plants and systems are required
to operate with constantly in-
creasing reliability. We will pro-
vide you with the support you
need to prevent a standstill from
occurring in the first place: with
a worldwide network and opti-
mum logistics chains.
Repairs
Downtimes cause problems in
the plant as well as unnecessary
costs. We can help you to re-
duce both to a minimum - with
our worldwide repair facilities.
Optimization
During the service life of ma-
chines and plants, there is often
a great potential for increasing
productivity or reducing costs.
To help you achieve this poten-
tial, we are offering a complete
range of optimization services.
Modernization
You can also rely on our support
when it comes to modernization
- with comprehensive services
from the planning phase all the
way to commissioning.
Service programs
Our service programs are se-
lected service packages for an
automation and drives system or
product group. The individual
services are coordinated with
each over to ensure smooth
coverage of the entire life cycle
and support optimum use of
your products and systems.
The services of a Service Pro-
gram can be flexibly adapted at
any time and used separately.
Examples of service programs:
7 Service contracts
7 Plant IT Security Services
7 Life Cycle Services for Drive Engineering
7 SIMATIC PCS 7 Life Cycle Services
7 SINUMERIK Manufacturing Excellence
7 SIMATIC Remote Support Services
Advantages at a glance:
7 Reduced downtimes for increased productivity
7 Optimized maintenance costs due to a tailored scope of ser-
vices
7 Costs that can be calculated and therefore planned
7 Service reliability due to guaranteed response times and
spare part delivery times
7 Customer service personnel will be supported and relieved of
additional tasks
7 Comprehensive service from a single source, fewer interfaces
and greater expertise
Contact information is available in the Internet at:
www.siemens.com/automation/partner
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Service & Support
17/7
Siemens KT 10.1 2012
17
Knowledge Base on DVD
For locations without online con-
nections to the Internet there are
excerpts of the free part of the
information sources available on
DVD (Service & Support Knowl-
edge Base). This DVD contains
all the latest product information
at the time of production (FAQs,
Downloads, Tips and Tricks, Up-
dates) as well as general infor-
mation on Service & Support.
The DVD also includes a full-text search and our Knowledge
Manager for targeted searches for solutions. The DVD will be up-
dated every 4 months.
Just the same as our online offer in the Internet, the Service &
Support Knowledge Base on DVD comes complete in 5 lan-
guages (German, English, French, Italian, Spanish).
You can order the Service & Support Knowledge Base DVD
from your Siemens contact.
Order no. 6ZB5310-0EP30-0BA2
Automation Value Card
Small card - great support
The Automation Value Card is an integral component of the com-
prehensive service concept with which Siemens Drive Automa-
tion and Drive Technologies will accompany you in each phase
of your automation project.
It doesn't matter whether you want just specific services from our
Technical Support or want to purchase something on our Online
portal, you can always pay with your Automation Value Card. No
invoicing, transparent and safe. With your personal card number
and associated PIN you can view the state of your account and
all transactions at any time.
Services on card. This is how it's done.
Card number and PIN are on the back of the Automation Value
Card. When delivered, the PIN is covered by a scratch field,
guaranteeing that the full credit is on the card.
By entering the card number and PIN you have full access to the
Service & Support services being offered. The charge for the
services procured is debited from the credits on your Automa-
tion Value Card.
All the services offered are marked in currency-neutral credits,
so you can use the Automation Value Card worldwide.
Order your Automation and Value Card easily and comfortably
like a product with your sales contact.
Detailed information on the services offered is available on our
Internet site at:
www.siemens.com/automation/service&support
Service & Support la Card: Examples
Automation Value Card order numbers
Credits Order no.
200 6ES7 997-0BA00-0XA0
500 6ES7 997-0BB00-0XA0
1 000 6ES7 997-0BC00-0XA0
10 000 6ES7 997-0BG00-0XA0
Technical Support
Priority Priority processing for urgent cases
24 h Availability round the clock
Extended Technical consulting for complex questions
Mature
Products
Consulting service for products that are not available
any more
Support Tools in the Support Shop
Tools that can be used directly for configuration, anal-
ysis and testing
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Alphabetical index
17/8
Siemens KT 10.1 2012
17
A
Automation Value Card .............................................................................17/7
B
Buffer module SITOP modular ..................................................................11/2
C
Circuit diagrams ........................................................................................11/6
Class2 version 24 V/3.7 A ...........................................................................4/3
Conditions of sale and delivery ...............................................................17/12
Configuring notes ......................................................................................16/2
Connector for devices in IP65 and IP67 ...................................................14/2
D
DC/DC converter .........................................................................................2/3
Device labeling plates ..............................................................................14/2
E
Export regulations ...................................................................................17/12
F
Flat design 24 V/10 A ..................................................................................7/3
Flat design 24 V/5 A ....................................................................................5/3
I
Installation notes......................................................................................16/10
International supply voltages and frequencies in low-voltage systems ...16/5
K
Knowledge Base on DVD .........................................................................17/7
L
LOGO!Power 24 V/1.3 A .............................................................................2/3
LOGO!Power 12 V/1.9 A ...........................................................................13/6
LOGO!Power 12 V/4.5 A ...........................................................................13/7
LOGO!Power 15 V/1.9 A .........................................................................13/12
LOGO!Power 15 V/4 A ............................................................................13/12
LOGO!Power 24 V/2.5 A .............................................................................3/2
LOGO!Power 24 V/4 A ................................................................................4/2
LOGO!Power 5 V/3 A ................................................................................13/4
LOGO!Power 5 V/6.3 A .............................................................................13/4
M
Mounting adapter for DIN rail ...................................................................14/2
Mounting bracket ......................................................................................14/2
Mounting, mounting areas and installation options .................................16/10
O
Outdoor version 24 V/2 A.............................................................................2/3
Outdoor version 24 V/5 A ............................................................................5/3
P
Parallel connections for voltage increase ...............................................16/15
Parallel connections for performance enhancement ..............................16/14
Partners at Industry Automation and Drive Technologies ........................17/2
Power connection plug for PSU300P ........................................................14/2
PSA100E 24 V/12 A ....................................................................................8/2
PSA100E 24 V/2.5 A ...................................................................................3/3
PSA100E 24 V/4 A ......................................................................................4/3
PSA100E 24 V/6 A ......................................................................................6/2
PSU100D 12 V/3 A ....................................................................................13/7
PSU100D 24 V/12.5 A .................................................................................8/2
PSU100D 24 V/2.1 A ...................................................................................3/3
PSU100D 24 V/3.1 A ...................................................................................4/3
PSU100D 24 V/4.1 A ...................................................................................4/3
PSU100D 24 V/6.2 A ...................................................................................6/2
PSU300B 24 V/30 A ..................................................................................10/2
PSU300P 24 V/8 A ......................................................................................9/2
R
Redundancy module PSE202U ................................................................11/2
S
S7-1200 version 24 V/2.5 A ........................................................................ 3/3
S7-200-Type 24 V/3.5 A .............................................................................. 4/2
S7-300 version 24 V/3 A ............................................................................. 2/3
S7-300 version 24 V/10 A ........................................................................... 7/3
S7-300 version 24 V/5 A ............................................................................. 5/3
Series connection to increase the voltage .............................................. 16/15
Signaling module SITOP modular ............................................................ 11/2
Siemens Solution Partner Automation ...................................................... 17/3
SIPLUS extreme ........................................................................................ 15/2
SITOP 1-phase ........................................................................................... 2/2
SITOP compact PSU100C 12 V/2 A ......................................................... 13/6
SITOP compact PSU100C 12 V/6.5 A ...................................................... 13/7
SITOP compact PSU100C 24 V/0.6 A ........................................................ 2/2
SITOP compact PSU100C 24 V/1.3 A ........................................................ 2/2
SITOP compact PSU100C 24 V/2.5 A ........................................................ 3/2
SITOP compact PSU100C 24 V/4 A ........................................................... 4/2
SITOP DC/DC 12 V/2.5 A ......................................................................... 13/6
SITOP dual 2 x 15 V/3.5 A ...................................................................... 13/12
SITOP flexi 3-52 V/2-10 A ......................................................................... 13/2
SITOP in SIMATIC-Design .......................................................................... 2/3
SITOP in SIMATIC-Design 24 V/10 A .......................................................... 7/3
SITOP in SIMATIC-Design 24 V/2.5 A ......................................................... 3/3
SITOP in SIMATIC-Design 24 V/3.5 A ......................................................... 4/2
SITOP in SIMATIC-Design 24 V/5 A ............................................................ 5/3
SITOP lite PSU100L 24 V/10 A ................................................................... 7/3
SITOP lite PSU100L 24 V/2.5 A .................................................................. 3/3
SITOP lite PSU100L 24 V/5 A ..................................................................... 5/3
SITOP modular 24 V/10 A .................................................................... 7/2, 9/2
SITOP modular 24 V/20 A .................................................................... 8/3, 9/3
SITOP modular 24 V/40 A .................................................................. 8/3, 10/3
SITOP modular 24 V/5 A ...................................................................... 5/2, 9/2
SITOP modular 48 V/20 A ....................................................................... 13/14
SITOP modular PSU100M 24 V/20 A .......................................................... 8/2
SITOP modular PSU300M 24 V/20 A .......................................................... 9/3
SITOP modular PSU300M 24 V/40 A ........................................................ 10/2
SITOP modular PSU300M 48 V/10 A ...................................................... 13/14
SITOP modular PSU400M 24 V/20 A .......................................................... 8/3
SITOP smart 24 V/10 A ............................................................................... 7/2
SITOP smart 24 V/2.5 A .............................................................................. 3/2
SITOP smart 24 V/5 A ................................................................................. 5/2
SITOP smart PSU300S 24 V/10 A ............................................................... 9/3
SITOP smart PSU300S 24 V/20 A ............................................................... 9/3
SITOP smart PSU300S 24 V/40 A ............................................................. 10/3
Software SITOP DC UPS .......................................................................... 12/4
Solution Partner Finder ............................................................................. 17/3
Standards and approvals ....................................................................... 16/20
Support ..................................................................................................... 17/5
U
Uninterruptible DC power supplies ........................................................... 12/2
KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Order No. index
17/9
Siemens KT 10.1 2012
17
Order No. Page Export regulations
AL ECCN
3RK1
3RK1 911-2BE50 14/2 N N
3RT1
3RT1 900-1SB20 14/2 N N
6AG1
6AG1 053-1AA00-2AA0 15/3 9I999 N
6AG1 203-1AA00-2AA0 15/3 9I999 N
6AG1 203-1SH31-2AA0 15/3 9I999 EAR99H
6AG1 305-1AA00-2AA0 15/3 9I999 EAR99H
6AG1 305-1BA80-2AA0 15/3 9I999 N
6AG1 307-1EA80-2AA0 15/3 9I999 N
6AG1 307-1KA02-7AA0 15/3 N N
6AG1 332-1SH71-4AA0 15/3 N N
6AG1 332-1SH71-7AA0 15/3 9I999 N
6AG1 334-2BA01-4AA0 15/3 9I999 N
6AG1 334-3BA00-2AA0 15/3, 15/4 9I999 N
6AG1 334-3BA00-4AA0 15/3 9I999 N
6AG1 336-3BA00-7AA0 15/3 N N
6AG1 337-3BA00-4AA0 15/3 9I999 N
6AG1 436-3BA00-7AA0 15/4 N N
6AG1 437-3BA00-4AA0 15/4 9I999 EAR99H
6AG1 437-3BA10-7AA0 15/4 N N
6AG1 931-2BA00-3AA0 15/3 9I999 EAR99H
6AG1 931-2EC21-2AA0 15/4 9I999 N
6AG1 931-2FC21-7AA0 15/4 N N
6AG1 936-3BA00-4AA0 15/3 9I999 N
6AG1 933-3BA00-2AA0 15/3, 15/4 9I999 N
6AG1 961-3BA01-7AA0 15/4 N N
6AG1 961-3BA10-6AA0 15/4 9I999 EAR99H
6AG1 961-3BA10-7AA0 15/4 9I999 N
6AG1 961-3BA21-4AX0 15/4 9I999 N
6AG1 961-3BA21-7AX0 15/4 N N
6EP1
6EP1 232-1AA00 3/6 N N
6EP1 232-1AA10 4/6 N N
6EP1 233-1AA00 6/4 N N
6EP1 234-1AA00 8/8 N N
6EP1 311-1SH03 13/16 N N
6EP1 311-1SH13 13/16 N N
6EP1 321-1LD00 13/16 N EAR99H
6EP1 321-1SH03 13/16 N N
6EP1 321-5BA00 13/16 N N
6EP1 322-1LD00 13/17 N EAR99H
6EP1 322-1SH03 13/16 N N
6EP1 322-5BA10 13/17 N N
6EP1 331-1LD00 3/6 N EAR99H
6EP1 331-1SH03 2/6 N N
6EP1 331-5BA00 2/6 N N
6EP1 331-5BA10 2/6 N N
6EP1 332-1LB00 3/6 N N
6EP1 332-1LD00 4/6 N EAR99H
6EP1 332-1LD10 4/6 N N
6EP1 332-1SH31 4/6 N N
6EP1 332-1SH43 3/6 N N
6EP1 332-1SH52 4/6 N N
6EP1 332-1SH71 3/6 N N
6EP1 332-2BA00 4/6 N N
6EP1 332-2BA10 3/6 N N
6EP1 332-5BA00 3/6 N N
6EP1 332-5BA10 4/6 N N
6EP1 333-1AL12 5/6 N N
6EP1 333-1LB00 5/6 N N
6EP1 333-1LD00 6/4 N EAR99H
6EP1 333-2AA01 5/6 N N
6EP1 333-2BA01 5/6 N N
6EP1 333-3BA00 5/6, 9/6 N N
6EP1 333-3BA00-8AC0 5/6 N N
6EP1 334-1AL12 7/6 N N
6EP1 334-1LB00 7/6 N N
Order No. Page Export regulations
AL ECCN
6EP1 334-1LD00
8/8 N EAR99H
6EP1 334-2AA01 7/6 N N
6EP1 334-2BA01 7/6 N N
6EP1 334-3BA00 7/6, 9/6 N N
6EP1 334-3BA00-8AB0 7/6 N N
6EP1 336-3BA00 8/8 N N
6EP1 336-3BA00-8AA0 8/8 N N
6EP1 336-3BA10 8/8 N N
6EP1 337-3BA00 8/8 N N
6EP1 351-1SH03 13/17 N N
6EP1 352-1SH03 13/17 N N
6EP1 353-0AA00 13/17 N N
6EP1 353-2BA00 13/16 N N
6EP1 424-3BA00 13/17 N N
6EP1 433-2CA00 9/6 N EAR99H
6EP1 436-3BA00 9/6 N N
6EP1 436-3BA00-8AA0 9/6 N N
6EP1 436-3BA10 9/6 N N
6EP1 437-3BA00 10/6 N N
6EP1 437-3BA00-8AA0 10/6 N N
6EP1 437-3BA10 10/6 N N
6EP1 437-3BA20 10/6 N N
6EP1 456-3BA00 13/17 N N
6EP1 457-3BA00 13/17 N N
6EP1 536-3AA00 8/8 N N
6EP1 621-2BA00 13/16 N N
6EP1 731-2BA00 2/6 N N
6EP1 732-0AA00 2/6 N EAR99H
6EP1 931-2DC21 12/22 N N
6EP1 931-2DC31 12/22 N N
6EP1 931-2DC42 12/22 N N
6EP1 931-2EC21 12/22 N N
6EP1 931-2EC31 12/22 N N
6EP1 931-2EC42 12/22 N N
6EP1 931-2FC21 12/22 N N
6EP1 931-2FC42 12/22 N N
6EP1 933-2EC41 12/22 N N
6EP1 933-2EC51 12/22 N N
6EP1 933-2NC01 12/22 N EAR99H
6EP1 933-2NC11 12/22 N EAR99H
6EP1 935-5PG01 12/22 N N
6EP1 935-6MC01 12/22 N EAR99H
6EP1 935-6MD11 12/22 N N
6EP1 935-6MD31 12/22 N N
6EP1 935-6ME21 12/22 N N
6EP1 935-6MF01 12/22 N N
6EP1 961-2BA00 11/9 N N
6EP1 961-2BA11 11/9 N N
6EP1 961-2BA21 11/9 N EAR99
6EP1 961-3BA01 11/9 N N
6EP1 961-3BA10 11/9 N N
6EP1 961-3BA21 11/9 N N
6EP1 967-2AA00 11/9 N N
6EP1 971-1BA00 14/2 N N
6EP1 971-2BA00 14/2 N N
6EP1 975-2ES00 12/22, 14/2 N N
6EP1 434-2BA10 9/6 N N
6EP1 436-2BA10 9/6 N N
6EP1 437-2BA20 10/6 N N
6ES7
6ES7 148-4PC00-0HA0 9/6 N EAR99H
6ES7 305-1BA80-0AA0 2/6 N N
6ES7 307-1BA01-0AA0 2/6 N N
6ES7 307-1EA01-0AA0 5/6 N N
6ES7 307-1EA80-0AA0 5/6 N N
6ES7 307-1KA02-0AA0 7/6 N N
6ES7 390-6BA00-0AA0 14/2 N N
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Notes
17/10
Siemens KT 10.1 2012
17