SITOP

Download as pdf or txt
Download as pdf or txt
You are on page 1of 164
At a glance
Powered by AI
The catalog covers power supply products from Siemens including SITOP, SIPLUS, and alternative voltages.

The catalog covers power supply products for 1-phase, 2-phase, and 3-phase applications with voltages of 24V DC and various amperages.

The document mentions that Siemens provides solutions for the manufacturing and process industries as well as building automation.

Power Supply SITOP

Catalog KT 10.1

2012
SITOP
Answers for industry.
Umschlag_Katalog_KT10_1_2012_en.indd 2 17.10.2011 17:34:35
Siemens AG 2011
Note:
Information on customer-specific power supplies is included on
our website under:
www.siemens.com/sitop
Industrial Controls IC 10
SIRIUS
E86060-K1010-A101-A2-7600
SIMATIC ST 70
Products for
Totally Integrated Automation
and Micro Automation
E86060-K4670-A101-B3-7600
SIMATIC HMI / ST 80/ST PC
PC-based Automation
Human Machine Interface Systems
PC-based Automation
E86060-K4680-A101-B8-7600
SINUMERIK & SINAMICS NC 61
Equipment for Machine Tools
E86060-K4461-A101-A3-7600
Motion Control PM 21
SIMOTION, SINAMICS S120
and Motors for
Production Machines
E86060-K4921-A101-A2-7600
Catalog CA 01 CA 01
Products for Automation and Drives
DVD: E86060-D4001-A510-C9-7600
Industry Mall
Information and Ordering Platform
in the Internet:
www.siemens.com/industrymall
Related catalogs
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Power supply SITOP
Catalog KT 10.1 2012
Supersedes:
Catalog KT 10.1 2009
Refer to the Industry Mall for current updates
of this catalog:
www.siemens.com/industrymall
The products contained in this
catalog can also be found in the
Interactive Catalog CA 01 on DVD.
Order No.:
E86060-D4001-A510-D0-7600
Please contact your local Siemens branch
Siemens AG 2011
The products and sys-
tems described in this
catalog are manufac-
tured/distributed under
application of a certified
quality management
system in accordance
with DIN EN ISO 9001
(Certified Registration
No. 1108). The certifi-
cate is recognized by all
IQNet countries.
Introduction
1
SITOP 1-phase
24 V DC, up to 2 A
2
SITOP 1-phase
24 V DC, 2.5 A
3
SITOP 1-phase
24 V DC, 4 A
4
SITOP 1-phase and 2-phase
24 V DC, 5 A
5
SITOP 1-phase and 2-phase
24 V DC, 6 A
6
SITOP 1-phase and 2-phase
24 V DC, 10 A
7
SITOP 1-phase and 2-phase
24 V DC, 12 up to 40 A
8
SITOP 3-phase
24 V DC, 5 up to 20 A
9
SITOP 3-phase
24 V DC, 30 up to 40 A
10
SITOP expansion modules
24 V DC
11
SITOP uninterruptible power supplies
DC UPS
12
SITOP
Alternative voltages
13
Accessories
14
SIPLUS power supplies
15
Technical information and
configuring notes
16
Appendix
17
Printed on paper
fromsustainably
managed forests and
controlled sources.
www.pefc.org PEFC/04-31-1267
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/2
Siemens KT 10.1 2012
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/3
Siemens KT 10.1 2012
Answers for industry.
Siemens Industry answers the challenges in the
manufacturing and the process industry as well as in
the building automation business. Our drive and automation
solutions based on Totally Integrated Automation (TIA) and
Totally Integrated Power (TIP) are employed in all kinds
of industry. In the manufacturing and the process industry.
In industrial as well as in functional buildings.
Siemens offers automation, drive, and
low-voltage switching technology as
well as industrial software from stan-
dard products up to entire industry solu-
tions. The industry software enables our
industry customers to optimize the en-
tire value chain from product design
and development through manufacture
and sales up to after-sales service. Our
electrical and mechanical components
offer integrated technologies for the en-
tire drive train from couplings to gear
units, from motors to control and drive
solutions for all engineering industries.
Our technology platform TIP offers ro-
bust solutions for power distribution.
The high quality of our products
sets industry-wide benchmarks.
High environmental aims are part of
our eco-management, and we imple-
ment these aims consistently. Right
from product design, possible effects on
the environment are examined. Hence
many of our products and systems are
RoHS compliant (Restriction of Hazard-
ous Substances). As a matter of course,
our production sites are certified ac-
cording to DIN EN ISO 14001, but to us,
environmental protection also means
most efficient utilization of valuable
resources. The best example are our
energy-efficient drives with energy sav-
ings up to 60 %.
Check out the opportunities our
automation and drive solutions provide.
And discover how you can sustainably
enhance your competitive edge with us.
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/4
Siemens KT 10.1 2012
SIMATIC IT
IO-Link
PROFIBUS PA
HART
Totally
Integrated
Automation
SIMATIC Distributed I/O
SIMATIC Controllers
Modular / PC-based
Energy Management
Asset Management
Field Level
SIMATIC Ident
Industrial Identication
Process Instrumentation
SIMATIC NET
Industrial
Communication
SIMOTION
Motion Control
SINUMERIK
Computer Numerical Control
Industrial Software for
Product Design
Production Planning
Engineering
Commissioning
Operation
Maintenance
Modernization and Upgrade
ERP Enterprise Resource Planning
MES Manufacturing Execution Systems
SIMATIC PCS 7
Process Control (DCS)
Operations Level
Management Level
Control Level
Setting standards in
productivity and competitiveness.
Totally Integrated Automation.
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/5
Siemens KT 10.1 2012
KNX GAMMA instabus
AS-Interface
PROFIBUS
Industrial Ethernet
PROFINET
Totally
Integrated
Power
Industrial Ethernet
Industrial Ethernet
Ethernet
Ethernet
SINAMICS Drive Systems Low-Voltage Distribution
SIMATIC HMI
Human Machine Interface
SIRIUS Industrial Controls
SIMATIC WinCC
SCADA-System
Thanks to Totally Integrated Automation, Siemens provides
an integrated basis for the implementation of customized
automation solutions in all industries from inbound to
outbound.
TIA is characterized by its unique continuity.
It provides maximum transparency at all levels
with reduced interfacing requirements covering
the field level, production control level, up to the
corporate management level. With TIA you also
profit throughout the complete life cycle of your
plant starting with the initial planning steps
through operation up to modernization, where
we offer a high measure of investment security re-
sulting from continuity in the further development
of our products and from reducing the number of
interfaces to a minimum.
The unique continuity is already a defined
characteristic at the development stage of
our products and systems.
The result: maximum interoperability covering
the controller, HMI, drives, up to the process
control system. This reduces the complexity of
the automation solution in your plant. You will
experience this, for example, in the engineering
phase of the automation solution in the form of
reduced time requirements and cost, or during
operation using the continuous diagnostics facili-
ties of Totally Integrated Automation for increasing
the availability of your plant.
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Selecting
Find your products in the structure tree, in the new "Bread-crumb"
navigation or with the integral search machine with expert functions.
Electronic configurators are also integrated into the Mall. Enter the
various characteristic values and the appropriate product will be dis-
played with the relevant order numbers. You can save configurations,
load them and reset them to their initial status.
Ordering
You can load the products that you have selected in this way into the
shopping basket at a click of the mouse. You can create your own tem-
plates and you will be informed about the availability of the products
in your shopping cart. You can load the completed parts lists directly
into Excel or Word.
Delivery status
When you have sent the order, you will receive a short e-mail confir-
mation which you can print out or save. With a click on "Carrier", you
will be directly connected to the website of the carrier where you can
easily track the delivery status.
Added value due to additional information
So you have found your product and want more information about it?
In just a few clicks of the mouse, you will arrive at the image data base,
manuals and operating instructions. Create your own user documen-
tation with My Documentation Manager.
Also available are FAQs, software downloads, certificates and techni-
cal data sheets as well as our training programs. In the image database
you will find, depending on the product, 2D/3D graphics, dimension
drawings and exploded drawings, characteristic curves or circuit
diagrams which you can download.
Convinced? We look forward to your visit!
Much more
than a catalog.
The Industry Mall.
You have a catalog in your hands that will serve
you well for selecting and ordering your products.
But have you heard of the electronic online cata-
log (the Industry Mall) and all its benefits? Take a
look around it sometime:
www.siemens.com/industrymall
KT10_EN_gesamt.book Seite 14 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/7
Siemens KT 10.1 2012
SITOP power supplies
Energy efficient and usable
world-wide
The fan-free power supplies deliver sta-
bilized 24 Volts and are characterized by
their compact and rugged design, high
overload capability, as well as special
energy efficiency. The high efficiency
across the entire load range and the low
no-load loss ensure efficient operation.
The large input voltage range and the
international approvals mean that use is
possible in almost all supply networks
worldwide.
Every day, SITOP is used successfully in
innumerable practical applications.
Quick selection and fast
delivery
With the SITOP Selection Tool - available
in the Internet under
www.siemens.com/sitop-selection-tool
and in the Industry Mall - the suitable
power supply can be selected quickly
and easily The selected products can be
saved or placed into the Mall's shopping
cart and then ordered there.
We deliver all SITOP standard products
from stock to ensure that you receive
the SITOP power supply you selected
quickly.
Customized SITOP products
Our standard power supplies cannot, of
course, satisfy the requirements of ev-
ery application. We can design a specific
power supply for your application-spe-
cific requirements. You benefit from the
expertise of large-scale production and
gain maximum development security
and quality.
Our customer-specific solutions are
used today in many sectors of mechani-
cal engineering, in automation technol-
ogy, vehicle electronics, equipment
manufacturing, or in industrial instru-
mentation technology.
If your are interested, please contact
your local Siemens office.
The benchmark in reliability, compactness and functionality
Efficient operation of a machine or plant requires a reliable, con-
stant power supply. The quality and reliability of the SITOP stabi-
lized power supplies ensure high levels of safety in DC power sup-
ply in industrial engineering and building management systems.
Our extensive selection of SITOP power supplies is enhanced by
expansion modules that extensively protect the 24 V power sup-
plies against interference on the primary and secondary side,
right up to complete all-round protection.
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/8
Siemens KT 10.1 2012
SITOP lite
Low-cost basic power supply
The new range of power supplies is designed for standard re-
quirements in industrial environments and offers all impor-
tant functions at a favorable price, of course without compro-
mising quality and the proverbial SITOP reliability. The wide-
range input with manual switchover supports connection to a
wide range of 1-phase supply systems. Thanks to the narrow
width, the primary switched-mode regulators require little
space on the DIN rail, and the good efficiency results in low
thermal losses in the control cabinet. Short-circuit and over-
load protection as well as UL approval for export ensure prob-
lem-free use.
Its essential characteristics are
24 V/2.5 A, 5 A and 10 A for industrial applications with
standard requirements
1-phase wide-range input with manual switchover
Narrow mounting width
High degree of efficiency
Green LED for "24 V OK"
Parallel connection possible
No lateral installation clearances required
Ambient temperature range of 0 C to 60 C
(above 45 C with derating)
Cooling through natural convection
Short-circuit and overload protection
Certification in accordance with UL
SITOP compact
The slim power supply unit for control boxes
Thanks to the extremely space-saving slim design, the new
power supply series for the lower performance range is espe-
cially suited to distributed applications in control boxes or in
small control cabinets. The switched-mode power supplies are
characterized by their low power losses throughout the load
range. The losses are extremely low even during idling which
predestines them for supplying machines and plants which
are frequently in stand-by mode. The SITOP PSU100C power
supplies have a wide-range input for AC and DC networks;
plug-in terminals facilitate the electrical connection.
Its essential characteristics are
For 24 V at 0.6 A, 1.3 A, 2.5 A and 4 A and for 12 V at 2 A
and 6.5 A
Small mounting surface thanks to its slim design
Wide-range input for 85 V to 264 V AC or 110 V to 300 V DC
High efficiency across the entire load range. Up to 28 % en-
ergy savings in comparison with similar devices
Low energy consumption during no-load operation or
stand-by. Energy savings of up to 53 % are possible
Adjustable output voltage
Green LED for "Output voltage OK"
Plug-in terminals
Temperature range from -20 C to +70 C
Comprehensive certifications, such as ATEX
KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/9
Siemens KT 10.1 2012
LOGO!Power
The flat power supply unit for distribution boards
The new miniature power supply units now offer even greater
performance in the smallest space: The efficiency has been
improved across the entire load range, and the power loss in
no-load operation has been cut in half. The wide-range input
now also allows operation with direct voltage, the switch-on
behavior has been optimized for capacitive loads, and the op-
erating temperature range has been extended to +70 C. The
power supplies with logic module design can be used ex-
tremely flexibly in numerous applications thanks to their
flat, stepped profile in distribution boards, for example.
Its essential characteristics are
2 performance classes, each with 5 V, 12 V, and 15 V
3 performance classes with 24 V
Flat LOGO! design
Wide-range input for 85 V to 264 V AC or 110 V to 300 V DC
Constant current for connection of loads with high inrush
current
Power reserve on starting up through 1.5 times the rated
current for capacitive loads
Adjustable output voltage
Green LED for "Output voltage OK"
Temperature range from -20 C to +70 C
Comprehensive certification, e.g. ATEX and GL
SITOP smart
The powerful standard power supply
SITOP smart is the optimum power supply for many 24 V ap-
plications, with the new SITOP PSU300S 10 A, 20 A, and 40 A
now also for 3-phase networks. Whether 1-phase or 3-phase:
They offer compact dimensions, a strong performance, and a
favorable price. Despite its compactness it offers an outstand-
ing overload withstand capability.
Thanks to the extra power feature with 1.5 times the rated
current for 5 seconds, even large loads can be switched on
without any problems. With a continuous rated power of 120
percent, the slim power supply units are among the most reli-
able of their kind.
Numerous certifications facilitate the universal and global use
and permit their use in hazardous areas .
Its essential characteristics are
24 V/2.5 A, 5 A, 10 A, 20 A and 40 A for standard
applications
24 V/10 A wall-mounted for high shock and vibration
requirements
Capable of providing extra power (150 %) for brief
operational overloads
Can be permanently overloaded with 120 %
(provided ambient temperature is less than 45 C)
No lateral installation clearances required
Output voltages are adjustable up to 28 V
PSU300S: With signaling contact 24 V DC OK
Comprehensive certification, e.g. GL and ATEX
Expandable with DC UPS, and extension modules
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/10
Siemens KT 10.1 2012
SITOP power supplies in SIMATIC design
The optimum supply for SIMATIC S7 and more
The original SIMATIC power supplies merge perfectly into the
PLC network in terms of their design and functionality. In ad-
dition to the following SIMATIC systems, they also supply fur-
ther loads reliably with 24 V.
Its essential characteristics are
SIMATIC S7-1200 The compact PM1207 power module
supplies power to the new micro PLCs. The automatic
range switchover ensures problem-free connection to
1-phase 120 to 230 V grids.
SIMATIC S7-200 This flat power supply unit is also used
for low installation depths.
SIMATIC S7-300 These innovative power supplies require
up to 33 % less space on the S7 rail than the previous
PS307. The range switchover to 1-phase 120/230 V AC
grids now takes place automatically, thus preventing oper-
ator errors. The scope of supply includes the connection
comb for the CPU, an optional adapter permits mounting
on a DIN rail.
The SIMATIC ET 200pro The power supply unit with IP67
is used as electronics/encoder supply and load voltage sup-
ply of the new I/O device. With a signaling contact for "24 V
OK" and "Overtemperature", as well as a second plug-in
connector for input voltage loop-through.
SITOP modular
The technology power supply for demanding solutions
SITOP modular fulfills the highest functionality requirements,
e.g. for use in complex plants and machines. The wide-range
input allows a connection to almost any electrical power sys-
tem worldwide and ensures a high degree of safety even if
there are large voltage fluctuations. The power boost provides
up to three times the rated current for brief periods. In the
event of an overload, you have two options: Constant current
with automatic restart or latching shutdown.
The innovated power supplies SITOP PSU100M 20 A with 1-
phase connection, the SITOP PSU300M 20 and 40 A 3-phase,
and the SITOP PSU400M 20 A with a second DC input have
even more to offer. Due to their slim design, they are among
the most compact units in their performance class. The inno-
vations include the integrated signaling contact for "24 V OK",
the extended input range, the high efficiency and 1.5 times
the rated current for up to 5 seconds.
Its essential characteristics are
For demanding applications from 5 to 40 A
DC/DC converter 24 V/20 A for drive and battery networks
48 V/10 A and 20 A enable small cable cross-sections
Compact metal enclosure
No lateral installation clearances required
Wide-range input
Extra power of 150 % for brief operational overloads
Power boost of 300 % for tripping protective devices
Selectable short-circuit response
A soft characteristic can be selected for parallel connection
High efficiency
Operating status on 3 LEDs
Expandable with SITOP add-on modules and DC UPS
KT10_EN_gesamt.book Seite 10 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/11
Siemens KT 10.1 2012
SITOP in special designs, made for special tasks
Well prepared for special tasks and conditions
Whether restricted installation conditions, harsh ambient con-
ditions, or special input or output voltages are concerned:
These standard power supply units also fulfill exceptional re-
quirements.
It is the purpose of the new, low cost power supplies
PSU100D, which reside in an aluminium housing, to provide
you with 12 V and 24 V voltages. The sturdy aluminium hous-
ing can be screwed directly to a wall. Or, if the task a t hand is
to charge batteries, you can use the SITOP PSU300B which is
optimized for battery charging. This PS comes in slim design
and 3-phase wide range input.
Its essential characteristics are
PSU100D cost-effective power supplies up to 300 W, for
direct wall mounting, in many orientations.
SITOP flat design with flat metal housing, suitable for DIN
rail mounting.
SITOP PSA100E for DIN rails or wall mounting
SITOP 3.7 A Class II, with power limiter set to 100 W
SITOP PSU300P in IP67 type of protection, identical in
construction to SIMATIC ET 200pro PS, but without the sec-
ond connector for looping the input voltage.
SITOP PSU300B power supply optimized for battery
charging, with 3-phase wide-range input, 12 V and 24 V
output voltages.
Alternative voltages
Power supplies with alternative output voltages
SITOP provides a reliable supply of precisely stabilized DC volt-
age not just to 24 V loads, but also to loads with "alternative"
supply voltages.
SITOP flexi: 3 52 V/10 A
Limitless diversity thanks to variable output. Allows flexible
adjustment between 3 and 52 V, so just one standard PS can
be used for different voltages.
SITOP compact: 12 V/2 A and 6.5 A
Narrow power supply, designed for switching cubicles, also
suitable for 12 V consumers.
LOGO!Power: 5 V, 12 V and 15 V
Flat power supply, for installation junction boxes, available in
two power classes.
SITOP modular: 48 V/10 A und 20 A
The high output voltage allows smaller strand cross sections
for wires leading to consumers.
SITOP DC/DC: 12 V/2.5 A
The DC/DC converter features a narrow DIN rail housing and
needs a 24 V DC input voltage. It is possible to operate it in
conjunction with a SITOP DC UPS, thus obtaining uninterrupt-
ible 12 V.
SITOP dual: 2 x 15 V/3.5 A
The electronics power supply for the control cabinet. The in-
dustry-standard rail-mounted device has two 15 V outputs.
For example, for electronic loads requiring 15 V.
KT10_EN_gesamt.book Seite 11 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/12
Siemens KT 10.1 2012
Expansion modules
Reliable protection against the most varied hazard
sources: SITOP expansion modules
A power supply unit on its own cannot guarantee fault-free
24 V supply. Power failures, extreme variations in the mains
voltage, or a faulty load can bring plant operation to a stand-
still and cause high costs. The expansion modules offer every-
thing from extensive protection against interference on the
primary and secondary side right up to complete all-round
protection.
The signaling module with signal contacts and remote ON/
OFF function optimally integrates SITOP modular (devices
without integral signaling contact) into automated plants.
For maximum availability, the redundancy module decou-
ples SITOP power supplies of the same type.
The buffer module bridges short power failures up to 3 sec-
onds with capacitors as energy storage.
The SITOP select diagnostics module and the new SITOP
PSE200U selectivity module offer selective protection of in-
dividual 24 V paths against overload and short-circuits.
With this protection and by means of fast fault localization,
downtimes can be reduced to a minimum. New features of
the selectivity module include the finely adjustable current
range (from 0.5 A), remote reset, and a reset button for
each channel.
DC UPS
Permanently reliable 24 V even when the power fails:
Uninterruptible power supplies
Supply network irregularities in the millisecond range are
compensated for supremely well by all our power supplies.
Large fluctuations or even power failures, however, require
special measures: The buffer module (see SITOP expansion
modules) ensures optimal protection in the case of brief
power failures up to 3 seconds.
SITOP UPS500 uses capacitors to cover power failures in the
time range of minutes. Its essential characteristics are:
Absolutely maintenance free DC UPS featuring high-capac-
ity double-layer capacitors.
Modularly cascadable for standard mounting rail: Basic
unit SITOP UPS500S 24 V / 15 A with integrated energy stor-
age 2.5 oder 5 kWs, combinable with up to three expansion
modules UPS501S (5 kWs).
SITOP UPS500P 24 V / 7 A, 5 or 10 kWs in IP65 type of pro-
tection, for distributed use.
Long-life capacitors protect your investment, replacements
can be postponed:
After 8 years the UPS500 (at 50 C ambient temperature)
still retains 80 % of its rated capacity.
No ventilation is required in the installation area
(VDE 0510 Part 2 / EN 50272-2).
Fast restoration of buffering capability.
DC UPS modules outfitted with batteries secure operation in
the time range of hours. Its essential characteristics are:
DC UPS modules 6 A, 15 A and 40 A.
Maintenance-free battery modules from 1.2 to 12 Ah.
High security and availability due to monitoring of back-up
capability status, battery cables, aging and charging status.
Long service life of consumers, and batteries , facilitated by
an integrated battery management.
DIP switches can be used for setting the following: Connec-
tion threshold for buffering, end-of-charge voltage, charg-
ing current, buffering time.
Uninterrupted transition from buffer ready to buffering.
Both DC UPS systems can be incorporated into PC-based auto-
mation solutions with a free software tool. This tool supports
the processing of status annunciations and the secure shut-
ting down of the PC.
KT10_EN_gesamt.book Seite 12 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/13
Siemens KT 10.1 2012
SITOP Selection Tool
find the appropriate power supply quickly and easily
The SITOP Selection Tool is available in the Internet under
www.siemens.com/sitop-selection-tool
and also in the Industry Mall. This tool enables you to find the
appropriate power supply in just a few steps.
And this is how it works:
Entering a few technical specifications the tool will automat-
ically select the relevant parameters and show the matching
products. You can edit the selection parameters anytime.
An added support is provided by the possibility to compare
several products according to their technical data. You can se-
lect between "all data", "all identical data" and "all different
data".
The products thus selected can be transferred into a product
list. You can export this list into several file formats, or even let
the Industry Mall adopt this list in the cart. It is also possible to
invoke additional data concerning the selected products, for
example 3D data, circuit diagram macros, or certificates.
First step: Preselect the relevant power supplies with the help of technical
properties
Second step: To further limit the selection compare the technical data of
several power supplies
Third step: Once you have have selected the appropriate product, you can
export the data or transfer it into the Industry Mall
KT10_EN_gesamt.book Seite 13 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/14
Siemens KT 10.1 2012

Input voltage Output current SITOP
lite
SITOP
compact
LOGO!Power SITOP
smart
SIMATIC design SITOP
modular
Special design
special uses
Output voltage 24 V DC The complete technical specifications on these products are on the pages shown
1-phase AC
120 V, 230 V 0.6 A 2/2
1.3 A 2/2 2/3
2 A 2/3
2.1 A 3/3
2.5 A 3/3 3/2 3/2 3/2 3/3 3/3
3.1 A 4/3
3.5 A 4/2
3.7 A 4/3
4 A 4/2 4/2 4/3
4.1 A 4/3
5 A 5/3 5/2 5/3 5/2 5/3
6 A 6/2
6.2 A 6/2
10 A 7/3 7/2 7/3 7/2 7/3
12 A 8/2
12.5 A 8/2
20 A 8/2, 8/3
40 A 8/3
1-phase DC
48 ... 220 V 0.375 A 2/2
48 ... 110 V 2 A 2/3
24 ... 110 V 2 A 2/3
110 ... 300 V 0.6 A 2/2
1.3 A 2/2 2/3
2.5 A 3/2 3/2
4 A 4/2 4/2
120 ... 375 V 2.1 A
3.1 A
4.1 A
6.2 A
12 A
200 ... 900 V 20 A 8/3
3-phase AC
400 ... 500 V 5 A 5/2, 9/2
8 A 9/2
10 A 9/3 7/2, 9/2
20 A 9/3 8/2, 8/3, 9/3
30 A 10/2
40 A 10/3 8/3, 10/2, 10/3
Selection table
SITOP power supplies
KT10_EN_gesamt.book Seite 14 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/15
Siemens KT 10.1 2012

Input voltage Output current SITOP
lite
SITOP
compact
LOGO!Power SITOP
smart
SIMATIC design SITOP
modular
Special design
special uses
Output voltage
5, 12, 15, 48 V DC
The complete technical specifications on these products are on the pages shown
1-phase AC
120 V, 230 V 3 - 52 V/
2 - 10 A
13/2
5 V/3 A 13/4
5 V/6.3 A 13/4
12 V/1.9 A 13/6
12 V/2 A 13/6
12 V/3 A 13/7
12 V/4.5 A 13/7
12 V/6.5 A 13/7
12 V/8.3 A 13/10
15 V/1.9 A 13/12
15 V/4 A 13/12
2 x 15 V/3.5 A 13/12
1-phase DC
24 V 12 V/2.5 A 13/6
110 ... 300 V 5 V/3 A 13/4
5 V/6.3 A 13/4
12 V/1.9 A 13/6
12 V/2 A 13/6
12 V/4.5 A 13/7
12 V/6.5 A 13/7
15 V/1.9 A 13/12
15 V/4 A 13/12
3-phase AC
400 ... 500 V 12 V/20 A 13/10
48 V/10 A 13/14
48 V/20 A 13/14
KT10_EN_gesamt.book Seite 15 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
1/16
Siemens KT 10.1 2012
KT10_EN_gesamt.book Seite 16 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
2
2/2 The smallest ones 0.375 A
2/2 SITOP PSU100C 0.6 A
2/2 SITOP PSU100C 1.3 A
2/3 LOGO!Power 1.3 A
2/3 The S7-300 version 2 A
2/3 The outdoor version 2 A
2/3 The DC/DC converter 2 A
2/6 Ordering data and additional information
SITOP 1-phase
24 V DC, up to 2 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current up to 2 A
2/2
Siemens KT 10.1 2012
2
Overview

Technical data
1)
SIPLUS module see page 15/2.
Product Special design
The smallest ones
SITOP compact
PSU100C
SITOP compact
PSU100C
Power supply, type 0.375 A 0.6 A 1.3 A
Order No. 6EP1 731-2BA00
1)
6EP1 331-5BA00 6EP1 331-5BA10
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
The optimum power supply units for
automation solutions in the lowest
performance range; with wide-
range input for AC or DC voltages;
thanks to their compact and slim
design, they are particularly
suitable for solutions where space
is limited and in conjunction with
low-voltage switchgear.
Narrow power supply in the lower
performance range, e.g. for
distributed use in cubicles.
Low energy consumption over the
entire power range, minimal
energy loss at no load, with
removable terminals.
Narrow power supply in the lower
performance range, e.g. for
distributed use in cubicles.
Low energy consumption over the
entire power range, minimal
energy loss at no load, with
removable terminals.
Product Special design
The smallest ones
SITOP compact
PSU100C
SITOP compact
PSU100C
Input
DC voltage 1-phase AC or DC 1-phase AC or DC
Rated voltage value V
in rated
48-220 V DC
Wide-range input
100-230 V AC
Wide-range input
100-230 V AC
Wide-range input
Voltage range 30 ... 264 V
(AC 30 ... 187 V AC)
85 ... 264 V AC or 110 ... 300 V DC 85 ... 264 V AC or 110 ... 300 V DC
Overvoltage resistance 2.3 x V
in

rated
, 1.3 ms 2.3 x V
in

rated
, 1.3 ms
Mains buffering
at I
out rated
> 10 ms at V
in
= 220 V > 20 ms at V
in
= 230 V > 20 ms at V
in
= 230 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
0.3-0.06 A 0.28-0.18 A 0.63-0.31 A
Switch-on current limit (+25 C) < 35 A, typ. 3 ms < 28 A < 34 A
I
2
t 1.2 A
2
s 0.7 A
2
s 1.2 A
2
s
Built-in incoming fuse F 4 A/250 V (not accessible) Internal Internal
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
6 A or higher, characteristic C,
suitable for DC
16 A or higher, characteristic B or
10 A or higher, characteristic C
16 A or higher, characteristic B or
10 A or higher, characteristic C
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
24 V DC 24 V DC 24 V DC
Total tolerance 3 % 3 % 3 %
Static line compensation Approx. 0.1 % Approx. 0.1 %
Static load compensation Approx. 0.1 % Approx. 0.2%
Residual ripple < 150 mV
pp
(typ. 50 mV
pp
) < 200 mV
pp
(typ. 40 mVpp) < 200 mV
pp
(typ. 25 mVpp)
Spikes (bandwidth: 20 MHz) < 240 mV
pp
(typ. 50 mV
pp
) < 300 mV
pp
(typ. 20 mVpp) < 300 mV
pp
(typ. 20 mVpp)
Adjustment range 22.2 ... 26.4 V
Status display Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
On/off behavior No overshoot of V
out
(soft start)
Overshoot of V
out
approx. 5 % Overshoot of V
out
approx. 5 %
Startup delay /
voltage rise
< 2.5 s/typ. 90 ms < 1 s/typ. 25 ms < 0.6 s/typ. 90 ms
Rated current value I
out rated
0.375 A 0.6 A 1.3 A
Current range
Up to +60 C 0 ... 0.375 A 0 ... 0.6 A (up to +55 C) 0 ... 1.3 A (up to +55 C)
Derating 0 ... 0.255 A (up to +70 C) 0 ... 0.33 A (up to +70 C) 0 ... 0.7 A (up to +70 C)
Dynamic overcurrent on
Power-up on short circuit
Short circuit during operation Typ. 2.7 A for 200 ms Typically 1 A Typically 3.1 A
Parallel switching for
enhanced performance
Not permitted Not permitted Yes, 2 units
NEW NEW
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current up to 2 A
2/3
Siemens KT 10.1 2012
2
2)
SIPLUS module see page 15/2.
LOGO!Power SITOP in SIMATIC design
The S7-300 version
SITOP in SIMATIC design
The outdoor version
Special design
The DC/DC converter
1.3 A 2 A 2 A 2 A
6EP1 331-1SH03 6ES7 307-1BA01-0AA0 6ES7 305-1BA80-0AA0
2)
6EP1 732-0AA00
LOGO!Power supplies are
optimally matched in design and
functionality to the LOGO! logic
modules; with wide-range input
85 V to 264 V AC and 110 V to
300 V DC, as well as an option for
installing in built-in miniature
distribution boards, they can be
used universally in the low-end
performance range.
The proven power supply in
SIMATIC S7-300 design; with PS-
CPU connecting comb and for
mounting directly on S7 rail.
The power supply for extreme
environmental conditions in
SIMATIC S7-300 design; can be
snapped onto S7 rail; with
PS-CPU connecting comb.
The DC/DC converter for
supply from battery and DC
systems; with a wide input voltage
range from 38 V to 121 V DC.
LOGO!Power SITOP in SIMATIC design
The S7-300 version
SITOP in SIMATIC design
The outdoor version
Special design
The DC/DC converter
1-phase AC or DC 1-phase AC DC voltage DC voltage
100-240 V AC
Wide-range input
120/230 V AC
Automatic
range switch-over
24 V-110 V DC
Wide-range input
48-110 V DC
Wide-range input
AC 85 ... 264 V or DC 110 ... 300 V 85 ... 132 V/170 ... 264 V 16.8 ... 138 V 38 ... 121 V
2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms 154 V; 0.1 s
> 40 ms at V
in
= 187 V > 20 ms at V
in
= 93/187 V > 10 ms at V
in rated
> 5 ms at V
in
= 48 V
50/60 Hz; 47 ... 63 Hz 50/60 Hz, 47 ... 63 Hz
0.7-0.35 A 0.9/0.5 A 2.7-0.6 A (4.0-0.9 A) 1.2-0.5 A
< 25 A < 22 A, < 3 ms < 20 A, < 10 ms < 33 A
< 0.8 A
2
s < 1.0 A
2
s < 5 A
2
s
Internal T 1.6 A/250 V (not accessible) T 6.3 A/250 V (not accessible) T 2.5 A (not accessible)
16 A or higher, characteristic B or
10 A or higher, characteristic C
3 A, characteristic C 10 A or higher, characteristic C,
suitable for DC
10 to 25 A, characteristic B, or 6 to
25 A, characteristic C,
DC-compatible
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
24 V DC 24 V DC 24 V DC 24 V DC
3 % 3 % 3 % 1 %
Approx. 0.1 % Approx. 0.1 % Approx. 0.2 % Approx. 0.1 %
Approx. 1.5 % Approx. 0.2 % Approx. 0.4% Approx. 0.4 %
< 200 mV
pp
(typ. 10 mV
pp
) < 50 mV
pp
(typ. < 5 mV
pp
) < 150 mV
pp
(typ. < 30 mV
pp
) < 100 mV
pp
< 300 mV
pp
(typ. 20 mV
pp
) < 150 mV
pp
(typ. < 20 mV
pp
) < 240 mV
pp
(typ. < 150 mV
pp
) < 300 mV
pp
22.2 ... 26.4 V 23.5 ... 26.5 V
Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
No overshoot of V
out

(soft start)
No overshoot of V
out

(soft start)
No overshoot of V
out
(soft start)
Overshoot of V
out
on startup max.
25 V
< 0.5 s/typ. 15 ms < 2 s/typ. 10 ms < 3 s/typ. 5 ms < 3 s/typ. 30 ms
1.3 A 2 A 2 A (3 A at V
in
> 24 V) 2 A
0 ... 1.3 A (up to +55 C) 0 ... 2 A 0 ... 2 A (3 A) 0 ... 2 A
0 ... 0.9 A (up to +70 C) 0 ... 2 A (up to +70 C)
Typ. 9 A for 90 ms Typ. 9 A for 270 ms
Typ. 9 A for 90 ms Typ. 9 A for 270 ms
Yes, 2 units Yes Yes, 2 units Yes, 2 units
NEW
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current up to 2 A
2/4
Siemens KT 10.1 2012
2
Technical specifications (continued)
Product Special design
The smallest ones
SITOP compact
PSU100C
SITOP compact
PSU100C
Power supply, type 0.375 A 0.6 A 1.3 A
Order No. 6EP1 731-2BA00 6EP1 331-5BA00 6EP1 331-5BA10
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 66% Approx. 82 % Approx. 86 %
Power loss at V
out rated
, I
out rated
Approx. 4.6 W Approx. 2.6 W Approx. 4.5 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
Typ. 0.3 % V
out
Typ. 0.1 % V
out
Typ. 0.1 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. 0.4 % V
out
Typ. 3 % V
out
(I
out
: 10/90/10 %)
Typ. 3 % V
out
(I
out
: 10/90/10 %)
Load step settling time
50 to 100 % Typ. 2 ms Typ. 3 ms (10 to 90 %) Typ. 5 ms (10 to 90 %)
100 to 50 % Typ. 2 ms Typ. 3 ms (10 to 90 %) Typ. 5 ms (10 to 90 %)
Protection and monitoring
Output overvoltage protection Yes, according to EN 60950 Yes, according to EN 60950 Yes, according to EN 60950
Current limitation 0.41 ... 0.49 A Typically 0.7 A Typically 1.4 A
Short-circuit protection Electronic shutdown, auto restart Electronic shutdown, auto restart Electronic shutdown, auto restart
Sustained short-circuit current rms
value
< 0.9 A
Overload/short-circuit indicator
Safety
Primary/secondary isolation Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Protection class Class I Class I Class I
Leakage current < 3.5 mA < 3.5 mA < 3.5 mA
Safety test Yes Yes; CB Scheme Yes; CB Scheme
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2
No. 142), File E143289; cURus-
recognized (UL 60950, CSA C22.2
No. 60950), File E151273
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cCSAus (CSA C22.2 No. 60950-1,
UL 60950-1)
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cCSAus (CSA C22.2 No. 60950-1,
UL 60950-1)
Explosion protection ATEX (EX) II 3G Ex nA IIC T4;
cCSAus (CSA C22.2 No. 213-
M1987, ANSI/ISA-12.12.01-2007)
Class I, Div. 2. Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T4;
cCSAus (CSA C22.2 No. 213-
M1987, ANSI/ISA-12.12.01-2007)
Class I, Div. 2. Group ABCD, T4
FM approval
Marine approval GL and ABS available soon GL and ABS available soon
Degree of protection (EN 60529) IP20 IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation Not applicable Not applicable Not applicable
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range -25 ... +70 C with natural
convection
-20 ... +70 C with natural
convection
-20 ... +70 C with natural
convection
Transport/storage temp. range -40 ... +70 C -40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L, N, PE
(DC input: L+1, M1, PE)
1 screw terminal each for
0.5 ... 2.5 mm
2

single-core/finely stranded
Removable screw terminals,
one each 0.5 ... 2.5 mm
2

solid/finely stranded
Removable screw terminals,
one each 0.5 ... 2.5 mm
2

solid/finely stranded
Output + 1 screw terminal for
0.5 ... 2.5 mm
2
1 screw terminal for
0.5 ... 2.5 mm
2
1 screw terminal for
0.5 ... 2.5 mm
2
Output 2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
Dimensions (W x H x D) in mm 22.5 80 91 22.5 x 80 x 100 30 x 80 x 100
Weight, approx. 0.14 kg 0.12 kg 0.17 kg
Installation Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail
EN 60715 35x7.5/15
Accessories
Removable spring-loaded
terminals (6EP1971-5BA00)
Removable spring-loaded
terminals (6EP1971-5BA00)
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current up to 2 A
2/5
Siemens KT 10.1 2012
2
LOGO!Power SITOP in SIMATIC design
The S7-300 version
SITOP in SIMATIC design
The outdoor version
Special design
The DC/DC converter
1.3 A 2 A 2 A 2 A
6EP1 331-1SH03 6ES7 307-1BA01-0AA0 6ES7 305-1BA80-0AA0 6EP1 732-0AA00

Approx. 85 % Approx. 84% Approx. 75 % Approx. 84 %
Approx. 6 W Approx. 9 W Approx. 16 W (24 W) Approx. 9 W

<0.2 % V
out
Typ. 0.1 % V
out
Typ. 0.3 % V
out
Typ. 0.3 % V
out
Typ. 1 % V
out
(I
out
: 10/90/10 %)
Typ. 0.8 % V
out
Typ. 2.5 % V
out
Typ. 0.8 % V
out

Typ. 1 ms (10 to 90 %) < 1 ms (typ. 0.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms)
Typ. 1 ms (90 to 10%) < 1 ms (typ. 0.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms)

Yes, according to EN 60950 Additional control loop, shutdown
at < 28.8 V, automatic restart
Additional control loop, shutdown
at approx. 30 V, automatic restart
Yes, suppressor diode at output
Typically 1.7 A 2.2 ... 2.6 A 3.3 ... 3.9 A 2.1 ... 3 A
Constant current characteristic Electronic shutdown, auto restart Electronic shutdown, auto restart Electronic shutdown, auto restart
< 2.4 A < 2 A < 2 A < 2 A

Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output V
out
acc. to
EN 60950-1, EN 50178, creepage
distances and clearances > 5 mm
Yes, safety extra low output
voltage V
out
according to
EN 60950-1
Class II (without protective conductor) Class I Class I Class I
< 3.5 mA (typ. 0.5 mA) < 3.5 mA (typ. 0.7 mA) < 3.5 mA (typ. 0.7 mA)
Yes; CB Scheme Yes Yes Yes
Yes Yes Yes Yes
cULus-listed (UL 508, CSA C22.2 No.
107.1), File E197259; cURus-recognized
(UL 60950, CSA C22.2 No. 60950),
File E151273
cULus-Listed (UL 508, CSA C22.2
No. 142), File E143289
UL-listed (UL 508),
File E143289, CSA
(CSA C22.2 No. 142)
cULus-listed (UL 508, CSA C22.2
No. 142), File E179336
ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Group ABCD, T4
ATEX (EX) II 3G Ex nA II T4;
UL 1604 Class I Div. 2
Group ABCD

Class I Div. 2. Group ABCD, T4 Class I Div. 2. Group ABCD, T4
GL, ABS In S7-300 system
IP20 IP20 IP20 IP20

EN 55022 Class B EN 55022 Class B EN 55011 Class A EN 55022 Class B
Not applicable Not applicable Not applicable Not applicable
EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2

-20 ... +70 C with natural convection 0 ... +60 C with natural
convection
-25 ... +70 C with natural
convection
0 ... +70 C with natural
convection
-40 ... +85 C -40 ... +85 C -40 ... +85 C -40 ... +70 C
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K5 according to EN
60721, transient condensation
permitted
Climate class 3K3 according to
EN 60721, no condensation

One screw-type terminal each (L, N)
for 0.5 ... 2.5 mm
2
solid/finely stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
1 screw terminal each for
0.5 ... 2.5 mm
2
single-core/finely
stranded
One screw-type terminal each for
2 0.5 ... 2.5/1.5 mm
2
solid/finely stranded
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
1 screw terminal for
2 0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
1 screw terminal for
2 0.5 ... 2.5 mm
2
54 90 55 40 125 120 80 125 120 80 135 120
0.17 kg 0.4 kg 0.75 kg 0.5 kg
Snaps onto DIN rail
EN 60715 35x7.5/15
Can be mounted onto S7 rail Can be mounted onto S7 rail Snaps onto DIN rail
EN 60715 357.5/15
Mounting adapter for standard
mounting rail (6EP1 971-1BA00)
Mounting adapter for DIN rail
(6ES7 390-6BA00-0AA0)

KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
SITOP 1-phase
24 V DC
Output current up to 2 A
2/6
Siemens KT 10.1 2012
2
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
Special design: The smallest ones
48-220 V DC 24 V DC 0.375 A 6EP1 731-2BA00
SITOP compact, PSU100C
100-230 V AC 24 V DC 0.6 A 6EP1 331-5BA00
100-230 V AC 24 V DC 1.3 A 6EP1 331-5BA10
LOGO!Power
100-240 V AC 24 V DC 1.3 A 6EP1 331-1SH03
SITOP in SIMATIC design,
S7-300 version
120/230 V AC 24 V DC 2 A 6ES7 307-1BA01-0AA0
SITOP in SIMATIC design,
Outdoor version
24-110 V DC 24 V DC 2 A 6ES7 305-1BA80-0AA0
Special design,
The DC/DC converter
48-110 V DC 24 V DC 2 A 6EP1 732-0AA00
NEW
NEW
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
3
3/2 SITOP smart 2.5 A
3/2 SITOP PSU100C 2.5 A
3/2 LOGO!Power 2.5 A
3/3 SIMATIC S7-1200 PM1207 2.5 A
3/3 SITOP PSU100L 2.5 A
3/3 PSU100D 2.1 A
3/3 SITOP PSA100E 2.5 A
3/6 Ordering data and additional information
SITOP 1-phase
24 V DC, 2.5 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 2.5 A
3/2
Siemens KT 10.1 2012
3
Overview
Technical specifications
Product SITOP smart SITOP compact
PSU100C
LOGO!Power
Power supply, type 2.5 A 2.5 A 2.5 A
Order No. 6EP1 332-2BA10 6EP1 332-5BA00 6EP1 332-1SH43
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
The single-phase power supply for
universal use; complies with EU
directive 94/9/EEC (ATEX 100a);
slim design; with 50 %
extra power for 5 s and 120 %
rated power up to 45 C
Narrow power supply in the lower
performance range, e.g. for
distributed use in cubicles.
Low energy consumption thanks
to a high degree of efficiency
across the entire power range and
minimum power loss in no-load
operation.
LOGO!Power supplies are
optimally matched in design and
functionality to the LOGO! logic
modules; with wide-range input
85 V to 264 V AC and 110 V to
300 V DC, as well as an option for
installing in built-in miniature
distribution boards, they can be
used universally in the low-end
performance range.
Product SITOP smart SITOP compact
PSU100C
LOGO!Power
Input
1-phase AC 1-phase AC or DC 1-phase AC or DC
Rated voltage value V
in rated
120/230 V AC
set by means of selector switch
100-230 V AC
Wide-range input
100-240 V AC
Wide-range input
Voltage range 85 ... 132 V/170 ... 264 V 85 ... 264 V AC or 110 ... 300 V DC AC 85 ... 264 V or
DC 110 ... 300 V
Overvoltage resistance 2.3 V
in

rated
, 1.3 ms 2.3 x V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
Mains buffering
at I
out rated
> 20 ms at V
in
= 93/187 V > 20 ms at V
in
= 230 V > 40 ms at V
in
= 187 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current value I
in rated
1.1/0.65 A 1.21-0.67 A 1.22-0.66 A
Switch-on current limit (+25 C) < 27 A, typ. 3 ms < 31 A < 46 A
I
2
t < 0.3 A
2
s < 2.4 A
2
s < 3 A
2
s
Built-in incoming fuse T 2 A/250 V (not accessible) Internal Internal
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
From 3 A, characteristic C 16 A or higher, characteristic B or
10 A or higher, characteristic C
16 A or higher, characteristic B or
10 A or higher, characteristic C
Output
Controlled, isolated
DC voltage
Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage value V
out rated
24 V DC 24 V DC 24 V DC
Total tolerance 3 % 3 % 3 %
Static line compensation Approx. 0.1 % Approx. 0.1 %
Static load compensation Approx. 0.5 % Approx. 1.5 %
Residual ripple < 150 mV
pp
(typ. 10 mV
pp
) < 200 mV
pp
< 200 mV
pp
(typ. 10 mV
pp
)
Spikes (bandwidth: 20 MHz) < 240 mV
pp
(typ. 50 mV
pp
) < 300 mV
pp
< 300 mV
pp
(typ. 50 mV
pp
)
Adjustment range 22.8 ... 28 V 22.2 ... 26.4 V 22.2 ... 26.4 V
Status display Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
On/off behavior Overshoot of V
out
approx. 4% Overshoot of V
out
approx. 1 % No overshoot of V
out

(soft start)
Startup delay/voltage rise < 0.1 s at 230 V AC/typ. 50 ms < 0.7 s/typ. 100 ms < 0.5 s/typ. 10 ms
Rated current value I
out rated
2.5 A 2.5 A 2.5 A
Current range
Up to +60 C 0 ... 2.5 A 0 ... 2.5 A (up to +50 C) 0 ... 2.5 A (up to +55 C)
Derating 0 ... 3 A (up to +45 C) 0 ... 0.75 A (up to +70 C) 0 ... 1.75 A (up to +70 C)
Dynamic overcurrent on
Power-up on short circuit Typ. 7 A for 100 ms
Short circuit during operation Typ. 7 A for 200 ms
Parallel switching for
enhanced performance
Yes, 2 units Yes, 2 units Yes, 2 units
NEW NEW
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 2.5 A
3/3
Siemens KT 10.1 2012
3
1)
SIPLUS module see page 15/3
SITOP in SIMATIC design
The S7-1200 version
SITOP lite
PSU100L
Special design
PSU100D
Special design
PSA100E
2.5 A 2.5 A 2.1 A 2.5 A
6EP1 332-1SH71
1)
6EP1 332-1LB00 6EP1 331-1LD00 6EP1 232-1AA00
The power supply PM1207 (Power
Module) is optimized for the new
SIMATIC S7-1200 controllers in
terms of design and functionality
and serves as an external supply
for the inputs and outputs which,
to prevent an imbalance, must not
be drawn from the CPU encoder
supply.
The low-cost power supply for
standard requirements in industrial
environments; slim design;
wide-range input with manual
switchover.
The low-cost power supply in flat
aluminum housing can be
screwed directly on a wall in
various mounting positions; with
wide-range input for global use.
The power supply is optimally
tailored to standard requirements in
the industrial environment; rugged
metal enclosure; flexible mounting
either on standard rails or directly on
a wall; removable terminals.
SITOP in SIMATIC design
The S7-1200 version
SITOP lite
PSU100L
Special design
PSU100D
Special design
PSA100E
1-phase AC 1-phase AC 1-phase AC 1-phase AC
120/230 V AC
Automatic range switch-over
120/230 V AC
set by means of selector switch
100-240 V AC
Wide-range input
230 V AC
85 ... 132 V/176 ... 264 V 85 ... 132 V/170 ... 264 V 85 ... 264 V 187 ... 264 V
2.3 x V
in rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
> 20 ms at V
in
= 93/187 V > 20 ms at V
in
= 93/187 V > 15 ms at V
in
= 115/230 V > 10 ms
50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
1.2/0.67 A 1.1/0.65 A 1.1-0.7 A 0.65 A
< 13 A, < 3 ms (V
in
= 230 V) < 27 A, typ. 3 ms < 60 A < 30 A
< 0.5 A
2
s < 0.3 A
2
s < 1.2 A
2
s < 0.8 A
2
s
T 3.15 A/250 V (not accessible) T 2 A/250 V (not accessible) Internal Internal
16 A or higher, characteristic B or
10 A or higher, characteristic C
3 A or higher, characteristic C 16 A or higher, characteristic B or
10 A or higher, characteristic C
6 A or higher, characteristic C
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
24 V DC 24 V DC 24 V DC 24 V DC
3 % 3 % 2 % 3 %
Approx. 0.1 % Approx. 0.1 % Approx. 0.5 % Approx. 0.1 %
Approx. 0.2 % Approx. 0.5 % Approx. 1.0 % Approx. 0.5 %
< 150 mV
pp
< 150 mV
pp
(typ. 10 mV
pp
) < 100 mV
pp
< 150 mV
pp
< 240 mV
pp
< 240 mV
pp
(typ. 50 mV
pp
) < 100 mV
pp
< 250 mV
pp
22.8 ... 26.4 V 22.0 ... 28.0 V 23 ... 26 V
24 V OK = green LED Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
No overshoot of V
out
(soft start)
Overshoot of V
out
approx. 4 % Overshoot of V
out
<2% Overshoot of V
out
<1 %
< 2 (6) s at 230 (120) V / typ. 10 ms < 1.5 s/typ. 150 ms < 1 s/< 30 ms < 1.5 s/< 100 ms
2.5 A 2.5 A 2.1 A 2.5 A
0 ... 2.5 A 0 ... 1.75 A 0 ... 2.1 A (up to + 50 C) 0 ... 2.5 A (up to + 45 C)
0 ... 2.5 A (up to + 45 C) 0 ... 1.0 A (up to + 70 C) 0 ... 1.25 A (up to + 70 C)
Typ. 6 A for 100 ms
Typ. 6 A for 100 ms
Yes, 2 units Yes, 2 units Yes, 2 units Yes, 2 units
NEW NEW
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 2.5 A
3/4
Siemens KT 10.1 2012
3
Technical specifications (continued)
Product SITOP smart SITOP compact
PSU100C
LOGO!Power
Power supply, type 2.5 A 2.5 A 2.5 A
Order No. 6EP1 332-2BA10 6EP1 332-5BA00 6EP1 332-1SH43
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 85 % Approx. 87 % Approx. 88 %
Power loss at V
out rated
, I
out rated
Approx. 9 W Approx. 9 W Approx. 8 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
Typ. 0.3 % V
out
Typ. 0.1 % V
out
< 0.2 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. 1% V
out
Typ. 3 % V
out
(I
out
: 10/90/10 %)
Typ. 2 % V
out
(I
out
: 10/90/10 %)
Load step settling time
50 to 100% Typ. 0.2 ms Typ. 4 ms (10 to 90 %) Typ. 1 ms (10 to 90 %)
100 to 50% Typ. 0.2 ms Typ. 4 ms (10 to 90 %) Typ. 1 ms (90 to 10 %)
Protection and monitoring
Output overvoltage protection <33V Yes, according to EN 60950 Yes, according to EN 60950
Current limitation Typ. 3.2 ... 3.4 A, overload capability
150 % I
out rated
to 5 s/min
Typically 3 A Typically 3.3 A
Short-circuit protection Constant current characteristic Electronic shutdown, auto restart Constant current characteristic
Sustained short-circuit current rms
value
Approx. 5 A Approx. 3.5 A
Overload/short-circuit indicator
Safety
Primary/secondary isolation Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Protection class Class I Class I Class II (without protective cndct)
Leakage current < 3.5 mA (typ. 0.4 mA) < 3.5 mA
Safety test Yes; CB scheme Yes; CB Scheme Yes; CB Scheme
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cCSAus (CSA C22.2
No. 60950-1, UL 60950-1)
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cCSAus (CSA C22.2 No. 60950-1,
UL 60950-1)
cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cURus-recognized (UL 60950,
CSA C22.2 No. 60950), File
E151273
Explosion protection ATEX (EX) II 3G Ex nA II T4;
UL 1604 Class I, Div. 2. Group
ABCD
ATEX (EX) II 3G Ex nA IIC T4 ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Group ABDC T4
FM approval Class I, Div. 2. Group ABCD T4
Marine approval GL GL and ABS available soon GL, ABS
Degree of protection (EN 60529) IP20 IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation Not applicable Not applicable Not applicable
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range 0 ... +60 C with natural
convection
-20 ... +70 C with natural
convection
-20 ... +70 C with natural
convection
Transport/storage temp. range -40 ... +85 C -40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L, N, PE One screw terminal each for
0.5 ... 2.5 mm
2
single-core/finely
stranded
Removable screw terminals,
one each 0.5 ... 2.5 mm
2

solid/finely stranded
One screw-type terminal each
(L, N) for 0.5 ... 2.5 mm
2

solid/finely stranded
Output + 2 screw terminals for
0.5 ... 2.5 mm
2
1 screw terminal for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
Output 2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
Dimensions (W x H x D) in mm 32.5 125 125 45 x 80 x 100 72 90 55
Weight, approx. 0.32 kg 0.22 kg 0.25 kg
Installation Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail
EN 60715 35x7.5/15
Accessories
Removable spring-loaded
terminals (6EP1971-5BA00)

KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 2.5 A
3/5
Siemens KT 10.1 2012
3
SITOP in SIMATIC design
The S7-1200 version
SITOP lite
PSU100L
Special design
PSU100D
Special design
PSA100E
2.5 A 2.5 A 2.1 A 2.5 A
6EP1 332-1SH71 6EP1 332-1LB00 6EP1 331-1LD00 6EP1 232-1AA00
Approx. 83 % Approx. 85 % Approx. 86 % Approx. 84 %
Approx. 12 W Approx. 9 W Approx. 8 W Approx. 11 W
Typ. 0.3 % V
out
Typ. 0.3 % V
out
Typ. 0.5 % V
out
<0.3 % V
out
Typ. 0.3 % V
out
Typ. 2 % V
out
(I
out
: 10/90/10 %) Typ. 5.0 % V
out
(0 to 100 %) Typ. 2.0 % V
out
< 5 ms Typ. 0.5 ms (10 to 90 %) Typ. 0.2 ms
< 5 ms Typ. 0.7 ms (90 to 10 %) Typ. 0.2 ms
< 33 V <33 V < 35 V < 35 V
2.65 A Typically 2.6 A 2.5 A 3 A
Constant current characteristic Constant current characteristic Electronic shutdown, auto restart Electronic shutdown, auto restart
Approx. 4 A Approx. 6 A < 2 A

Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, safety extra low output
voltage V
out
according to
EN 60950-1
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Class I Class I Class I Class I
< 3.5 mA < 3.5 mA (typ. 0.4 mA) < 3.5 mA (typ. 1 mA) < 3.5 mA (typ. 0.4 mA)
Yes Yes; CB Scheme in preparation Yes; CB Scheme in preparation Yes; CB Scheme
Yes Yes Yes Yes
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259; cULus-
Recognized (UL 60950-1, CSA
C22.2 No. 60950-1), File E151273
cULus-Listed (UL 508, CSA C22.2
No. 107.1) in preparation
cULus-Listed (UL 508, CSA C22.2
No. 107.1) in preparation,
cURus (UL 60950-1, CSA C22.2
No. 60950-1) in preparation
cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259
ATEX (EX) II 3G Ex nA T4

GL, ABS, DNV, NK, BV, LRS
IP20 IP20 IP20 IP20
EN 55022 Class B EN 55022 Class A EN 55022 Class B EN 55022 Class B
Not applicable Not applicable Not applicable Not applicable
EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
-10 ... +70 C with natural
convection
-10 ... +70 C with natural
convection
-40 ... +85 C -40 ... +85 C -25 ... +85 C -40 ... +85 C
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
One screw terminal each for
0.5 ... 2.5 mm
2
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.3 ... 1.3 mm
2
solid/finely
stranded
Removable screw terminal, each
1 x 0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
1 screw terminal for 0.3 ... 1.3 mm
2

solid/finely stranded
Removable screw terminal, each
1 x 0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
1 screw terminal for 0.3 ... 1.3 mm
2

solid/finely stranded
Removable screw terminal, each
1 x 0.5 ... 2.5 mm
2
70 x 100 x 75 32.5 125 125 97 x 128 x 38 52 x 170 x 110
0.3 kg 0.32 kg 0.35 kg 0.8 kg
Snaps onto DIN rail
EN 60715 35x7.5/15.
Wall mounting
Snaps onto DIN rail EN 60715
35x7.5/15
Wall mounting Snaps onto DIN rail EN 60715
35x7.5/15. Wall mounting

KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 2.5 A
3/6
Siemens KT 10.1 2012
3
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP smart
120/230 V AC 24 V DC 2.5 A 6EP1 332-2BA10
SITOP compact, PSU100C
100-230 V AC 24 V DC 2.5 A 6EP1 332-5BA00
LOGO!Power
100-240 V AC 24 V DC 2.5 A 6EP1 332-1SH43
SITOP in SIMATIC design,
S7-1200 version
120/230 V AC 24 V DC 2.5 A 6EP1 332-1SH71
SITOP lite, PSU100L
(Planned delivery date:
November 2011)
120/230 V AC 24 V DC 2.5 A 6EP1 332-1LB00
Special design, PSU100D
(Planned delivery date:
December 2011)
100-240 V AC 24 V DC 2.1 A 6EP1 331-1LD00
Special design, PSA100E
230 V AC 24 V DC 2.5 A 6EP1 232-1AA00
NEW
NEW
NEW
NEW
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
4
4/2 SITOP PSU100C 4 A
4/2 LOGO!Power 4 A
4/2 The S7-200 version 3.5 A
4/3 PSU100D 3.1 A
4/3 The Class2 version 3.7 A
4/3 SITOP PSA100E 4 A
4/3 PSU100D 4.1 A
4/6 Ordering data and additional information
SITOP 1-phase
24 V DC, 4 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 4 A
4/2
Siemens KT 10.1 2012
4
Overview
Technical specifications
1)
SIPLUS module see page 15/3.
Product SITOP compact
PSU100C
LOGO!Power SITOP in SIMATIC design
The S7-200 version
Power supply, type 4 A 4 A 3.5 A
Order No. 6EP1 332-5BA10 6EP1 332-1SH52 6EP1 332-1SH31
1)

The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
Narrow power supply in the lower
performance range, e.g. for
distributed use in cubicles.
Low energy consumption thanks
to a high degree of efficiency
across the entire power range and
minimum power loss in no-load
operation.
LOGO!Power supplies are
optimally matched in design and
functionality to the LOGO! logic
modules; with wide-range input
85 V to 264 V AC and 110 V to
300 V DC, as well as an option for
installing in built-in miniature
distribution boards, they can be
used universally in the low-end
performance range.
Optimally matched in design and
functionality to the SIMATIC
S7-200 micro PLC; flat design,
particularly suitable for low
cabinet depths.
Product SITOP compact
PSU100C
LOGO!Power SITOP in SIMATIC design
The S7-200 version
Input
1-phase AC or DC 1-phase AC or DC 1-phase AC
Rated voltage value V
in rated
100-230 V AC
wide-range input
100-240 V AC
Wide-range input
120/230 V AC
Set with wire jumper
Voltage range 85 ... 264 V AC or 110 ... 300 V DC AC 85 ... 264 V
DC 110 300 V
93 ... 132 V/187 ... 264 V
Overvoltage resistance 2.3 x V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
Mains buffering at I
out rated
> 20 ms at V
in
= 230 V > 40 ms at V
in
= 187 V > 20 ms at V
in
= 187 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
0.28-0.18 A 1.95-0.97 A 1.65/0.95 A
Switch-on current limit (+25 C) < 35 A < 30 A < 33 A, < 3 ms (V
in
= 230 V)
I
2
t < 3 A
2
s < 2.5 A
2
s < 1.0 A
2
s
Built-in incoming fuse Internal Internal T 2.5 A/250 V (not accessible)
Recommended miniature circuit
breaker
(IEC 898) in the mains power input
16 A or higher, characteristic B or
10 A or higher, characteristic C
16 A or higher, characteristic B or
10 A or higher, characteristic C
Two-pole miniature circuit breaker,
10 A or higher, characteristic C or
6 A or higher, characteristic D
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
24 V DC 24 V DC 24 V DC
Total tolerance 3 % 3 % 5 % (typ. 2 %)
Static line compensation Approx. 0.1 % Approx. 0.1 %
Static load compensation Approx. 1.5 % Approx. 0.2 %
Residual ripple < 200 mV
pp
< 200 mV
pp
(typ. 30 mV
pp
) < 150 mV
pp
(typ. 30 mV
pp
)
Spikes (bandwidth: 20 MHz) < 300 mV
pp
< 300 mV
pp
(typ. 60 mV
pp
) < 240 mV
pp
(typ. 110 mV
pp
)
Adjustment range 22.2 ... 26.4 V 22.2 ... 26.4 V
Status display Green LED for 24 V OK Green LED for 24 V OK
On/off behavior Overshoot of V
out
approx. 1 % No overshoot of V
out

(soft start)
No overshoot of V
out
(soft start)
Startup delay/voltage rise < 1 s/typ. 500 ms < 0.5 s/typ. 15 ms < 1 s/typ. 80 ms
Rated current value I
out rated
4 A 4 A 3.5 A
Current range
Up to +60 C 0 ... 4 A (up to +50 C) 0 ... 4 A (up to +55 C) 0 ... 3.5 A
Derating 0 ... 1.2 A (up to +70 C) 0 ... 2.8 A (up to +70 C)
Dynamic overcurrent on
Power-up on short circuit Typ. 5 A for 100 ms
Short circuit during operation Typ. 5 A for 100 ms
Parallel switching for
enhanced performance
Yes, 2 units Yes, 2 units Yes, up to 5 units
NEW NEW
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 4 A
4/3
Siemens KT 10.1 2012
4
2)
Only permissible at ambient temperature 0 C to +50 C.
Special design
PSU100D
Special design
The Class2 version
Special design
PSA100E
Special design
PSU100D
3.1 A 3.7 A 4 A 4.1 A
6EP1 332-1LD00 6EP1 332-2BA00 6EP1 232-1AA10 6EP1 332-1LD10
The low-cost power supply in flat
aluminum housing can be
screwed directly on a wall in
various mounting positions; with
wide-range input for global use.
The Class2 version with output
limited to 100 W maximum.
The power supply is optimally
tailored to standard requirements
in the industrial environment;
rugged metal enclosure; flexible
mounting either on standard rails
or directly on a wall; removable
terminals.
The low-cost power supply in flat
aluminum housing can be screwed
directly on a wall in various
mounting positions;
with wide-range input for global use.
Special design
PSU100D
Special design
The Class2 version
Special design
PSA100E
Special design
PSU100D
1-phase AC 1-phase AC 1-phase AC 1-phase AC
100-240 V AC
Wide-range input
120/230 V AC
Set via wire jumper
230 V AC 120-240 V AC
Wide-range input
85 ... 264 V 93 ... 132 V/187 ... 264 V 187 ... 264 V 85 ... 264 V
2.3 V
in

rated
, 1.3 ms
> 15 ms at V
in
= 115/230 V > 10 ms at V
in
= 93/187 V > 10 ms > 15 ms at V
in
= 115/230 V
50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
1.5-1.0 A 1.8/0.7 A 1.1 A 2.0-1.1 A
< 60 A < 32 A, typ. 3 ms (V
in
= 230 V) < 30 A < 75 A
1.2 A
2
s < 0.8 A
2
s < 0.8 A
2
s 4 A
2
s
Internal T 3.15 A/250 V (not accessible) Internal Internal
10 A or higher, characteristic C or
16 A, characteristic B
From 6 A, characteristic C From 6 A, characteristic C 10 A or higher, characteristic C or
16 A, characteristic B
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
24 V DC 24 V DC 24 V DC 24 V DC
2 % 3 % 3 % 2 %
Approx. 0.5 % Approx. 0.1 % Approx. 0.1 % Approx. 0.5 %
Approx. 1.0 % Approx. 0.2 % Approx. 0.5 % Approx. 1.0 %
< 100 mV
pp
< 150 mV
pp
< 150 mV
pp
< 100 mV
pp
< 100 mV
pp
< 240 mV
pp
< 250 mV
pp
< 100 mV
pp
22.0 ... 28.0 V 22.8 ... 26.4 V
2)
23 ... 26 V 22.0 ... 28.0 V
Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
Overshoot of V
out
< 2 % No overshoot of V
out
(soft start)
Overshoot of V
out
< 1 % Overshoot of V
out
< 2 %
< 2.5 s/< 30 ms < 3 s/typ. 80 ms < 1.5 s/< 200 ms < 1 s/< 30 ms
3.1 A 3.7 A 4 A 4.1 A
0 ... 3.1 A (up to +50 C) 0 ... 3.7 A 0 ... 4 A (up to +45 C) 0 ... 4.1 A (up to +50 C)
0 ... 1.5 A (up to +70 C) 0 ... 2 A (up to +70 C) 0 ... 2.0 A (up to +70 C)
Yes, 2 units Yes, 2 units
2)
Yes, 2 units Yes, 2 units
NEW NEW
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 4 A
4/4
Siemens KT 10.1 2012
4
Technical specifications (continued)
Product SITOP compact
PSU100C
LOGO!Power SITOP in SIMATIC design
The S7-200 version
Power supply, type 4 A 4 A 3.5 A
Order No. 6EP1 332-5BA10 6EP1 332-1SH52 6EP1 332-1SH31
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 88 % Approx. 89 % Approx. 84 %
Power loss at V
out rated
, I
out rated
Approx. 13 W Approx. 12 W Approx. 16 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
<0.1 % V
out
<0.2 % V
out
Typ. 0.3 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. 3 % V
out
(I
out
: 10/90/10 %)
Typ. 1.5 % V
out
(I
out
: 10/90/10 %)
Typ. 3 % V
out
Load step settling time
50 to 100 % Typ. 4 ms (10 to 90 %) Typ. 1 ms (10 to 90 %) < 5 ms
100 to 50 % Typ. 4 ms (90 to 10%) Typ. 1 ms (90 to 10%) < 5 ms
Protection and monitoring
Output overvoltage protection Yes, according to EN 60950 Yes, according to EN 60950 Yes, according to EN 60950
Current limitation Typically 4.8 A Typically 5.2 A 3.8 A
Short-circuit protection Electronic shutdown, automatic
restart
Constant current characteristic Constant current characteristic up
to typ. 14 V, electronic shutdown
below that, automatic restart
Sustained short-circuit current rms
value
< 7.9 A < 4 A
Overload/short-circuit indicator
Safety
Primary/secondary isolation Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, safety extra low output
voltage V
out
according to
EN 60950-1
Protection class Class I Class II (without protective cndct) Class I
Leakage current < 3.5 mA < 3.5 mA
Safety test Yes; CB scheme Yes; CB Scheme Yes
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cCSAus (CSA C22.2 No. 60950-1,
UL 60950-1)
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cURus-Recognized (UL 60950, CSA
C22.2 No. 60950), File E151273
cULus-Listed (UL 508, CSA C22.2
No. 142), File E143289
Explosion protection ATEX (EX) II 3G Ex nA IIC T4 ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Group ABCD, T4

FM approval Class I, Div. 2. Group ABCD, T4


Marine approval GL and ABS available soon GL, ABS
Degree of protection (EN 60529) IP20 IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation EN 61000-3-2 EN 61000-3-2 EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range -20 ... +70 C with natural convection 20 ... +70 C with natural
convection
0 ... +60 C with natural
convection
Transport/storage temperature range -40 ... +85 C 40 ... +85 C 40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L, N, PE Removable screw terminals, one
each 0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each (L, N)
for 0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 1.5 mm
2
solid/finely
stranded
Output + 1 screw terminal for 0.5 ... 2.5 mm
2
2 screw terminals for 0.5 to 2.5 mm
2
1 screw terminal for 0.5 ... 1 mm
2
Output 2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 to 2.5 mm
2
2 screw terminals for
0.5 ... 1 mm
2
Dimensions (W x H x D) in mm 52.5 x 80 x 100 90 90 55 160 80 62
Weight, approx. 0.32 kg 0.34 kg 0.5 kg
Installation Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15. Wall mounting
Accessories
Removable spring-loaded terminals
(6EP1971-5BA00)

KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 4 A
4/5
Siemens KT 10.1 2012
4
Special design
PSU100D
Special design
The Class2 version
Special design
PSA100E
Special design
PSU100D
3.1 A 3.7 A 4 A 4.1 A
6EP1 332-1LD00 6EP1 332-2BA00 6EP1 232-1AA10 6EP1 332-1LD10
Approx. 86 % > 80 % Approx. 87 % Approx. 86 %
Approx. 12 W Approx. 22 W Approx. 15 W Approx. 16 W
Typ. 0.5 % V
out
Typ. 0.3 % V
out
<0.3 % V
out
Typ. 0.5 % V
out
Typ. 5.0 % V
out
(0 to 100 %) Typ. 2.5 % V
out
Typ. 3.0 % V
out
Typ. 5.0 % V
out
(0 to 100 %)
Typ. 0.2 ms Typ. 0.2 ms
Typ. 0.2 ms Typ. 0.2 ms
< 35 V Yes, according to EN 60950 < 35 V < 35 V
3.7 A Typ. 3.8 ... 4.1 A Typically 4.4 A 4.9 A
Electronic shutdown,
automatic restart
Electronic shutdown, automatic
restart
Electronic shutdown,
automatic restart
Electronic shutdown,
automatic restart
Approx. 6 A < 3 A Approx. 10 A

Yes, safety extra low output
voltage V
out
according to
EN 60950-1
Yes, safety extra low output
voltage V
out
according to
EN 60950-1
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, safety extra low output
voltage V
out
according to
EN 60950-1
Class I Class I Class I Class I
< 3.5 mA (typ. 1 mA) < 3.5 mA (typ. 0.4 mA) < 3.5 mA (typ. 0.4 mA) < 3.5 mA (typ. 1 mA)
Yes; CB Scheme in preparation Yes; CB Scheme Yes; CB Scheme Yes; CB Scheme in preparation
Yes Yes Yes Yes
cULus-Listed (UL 508, CSA C22.2
No. 107.1) in preparation,
cURus (UL 60950-1, CSA C22.2
No. 60950-1) in preparation
cULus-listed (UL 508, CSA C22.2
No. 142), File E143289; cURus-
recognized (UL 1950, CSA C22.2
No. 60950), File E151273; UL 1310
cULus-Listed (UL 508, CSA C22.2
No.107.1), File E197259
cULus-Listed (UL 508, CSA C22.2
No. 107.1) in preparation,
cURus (UL 60950-1, CSA C22.2
No. 60950-1) in preparation



IP20 IP20 IP20 IP20
EN 55022 Class B EN 55022 Class B EN 55022 Class B EN 55022 Class B
EN 61000-3-2 EN 61000-3-2 EN 61000-3-2
EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
-10 ... +70 C with natural
convection
0 ... +60 C with natural
convection
-10 ... +70 C with natural
convection
-10 ... +70 C with natural
convection
-25 ... +85 C -40 ... +85 C -40 ... +85 C -25 ... +85 C
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
One screw-type terminal each for
0.3 ... 1.3 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
Removable screw terminal, each
1 0.5 ... 2.5 mm
2
One screw-type terminal each for
0.3 ... 1.3 mm
2
solid/finely
stranded
1 screw terminal for 0.3 ... 1.3 mm
2
1 screw terminal for 0.5 ... 2.5 mm
2
Removable screw terminal,
1 0.5 ... 2.5 mm
2
2 screw terminals for
0.3 ... 1.3 mm
2

1 screw terminal for
0.3 ... 1.3 mm
2

2 screw terminals for
0.5 ... 2.5 mm
2
Removable screw terminal,
1 0.5 ... 2.5 mm
2
2 screw terminals for
0.3 ... 1.3 mm
2

97 x 128 x 38 75 125 125 52 170 110 97 x 158 x 38
0.37 kg 0.75 kg 0.8 kg 0.5 kg
Wall mounting Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15. Wall mounting
Wall mounting

KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase
24 V DC
Output current 4 A
4/6
Siemens KT 10.1 2012
4
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP compact, PSU100C
100-230 V AC 24 V DC 4 A 6EP1 332-5BA10
LOGO!Power
100-240 V AC 24 V DC 4 A 6EP1 332-1SH52
SITOP in SIMATIC design,
The S7-200 version
120/230 V AC 24 V DC 3.5 A 6EP1 332-1SH31
Special design,
The Class2 version
120/230 V AC 24 V DC 3.7 A 6EP1 332-2BA00
Special design, PSU100D
(Planned delivery date:
December 2011)
100-240 V AC 24 V DC 3.1 A 6EP1 332-1LD00
Special design, PSA100E
230 V AC 24 V DC 4 A 6EP1 232-1AA10
Special design, PSU100D
(Planned delivery date:
December 2011)
100-240 V AC 24 V DC 4.1 A 6EP1 332-1LD10
NEW
NEW
NEW
NEW
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
5
5/2 SITOP modular 5 A
5/2 SITOP smart 5 A
5/3 SITOP PSU100L 5 A
5/3 The S7-300 version 5 A
5/3 The outdoor version 5 A
5/3 The flat design 5 A
5/6 Ordering data and additional information
SITOP 1-phase and 2-phase
24 V DC, 5 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 5 A
5/2
Siemens KT 10.1 2012
5
Overview
Technical data
1)
SITOP modular plus 6EP1 333-3BA00-8AC0, PCB with protective coating.
2)
SIPLUS module see page 15/3.
Product SITOP modular SITOP smart SITOP smart
Power supply, type 5 A 5 A 5 A
Order No. 6EP1 333-3BA00
1)2)
6EP1 333-2AA01 6EP1 333-2BA01
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
The modular power supply with
1-phase and 2-phase wide-range
input for global use; with switch-
able output characteristic; func-
tional expansion possible using
expansion modules.
The 1-phase power supply for
universal use; complies with EU
directive 94/9/EEC (ATEX 100a);
slim design; with 50 % extra power
for 5 s and 120 % rated power up
to 45 C; without limiting supply
harmonics.
The 1-phase power supply for
universal use; complies with EU
directive 94/9/EEC (ATEX 100a);
slim design; with 50 % extra power
for 5 s and 120 % rated power up
to 45 C.
Expansion possibilities Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12)
Product SITOP modular SITOP smart SITOP smart
Input
1-phase and 2-phase AC 1-phase AC 1-phase AC
Rated voltage value V
in rated
120-230/230-500 V AC
Set by means of selector switch
on device
120/230 V AC
Set by means of selector switch
on device
120/230 V AC
Set by means of selector switch
on device
Voltage range 85 ... 264/176 ... 500 V
(startup from V
in
90/180 V)
85 ... 132 V/170 ... 264 V 85 ... 132 V/170 ... 264 V
Overvoltage resistance 1300 V
peak
, 1.3 ms 2.3 V
in

rated
, 1.3 ms 2.3 V
in rated
, 1.3 ms
Mains buffering at I
out rated
> 25 ms at V
in
= 120/230 V > 20 ms at V
in
= 93/187 V > 20 ms at V
in
= 93/187 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current value I
in rated
2.2-1.2/1.2-0.61 A 2.1/1.15 A 2.1/1.15 A
Switch-on current limit (+25 C) < 35 A < 32 A, typ. 3 ms < 32 A, typ. 3 ms
I
2
t < 1.7 A
2
s < 0.8 A
2
s < 0.8 A
2
s
Built-in incoming fuse T 3.15 A (not accessible) T 3.15A/250V (not accessible) T 3.15A/250V (not accessible)
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
From 6 A (10 A) characteristic C
(B); required for two-phase
operation: MCB 2-pole coupled or
circuit-breaker 3RV2011-1EA10
(setting 3.8 A) or 3RV2711-1ED10
(UL 489) at 230 V; 3RV2011-
1DA10 (setting 3 A) or 3RV2711-
1DD10 (UL 489) at 400/500 V
From 6 A, characteristic C From 6 A, characteristic C
Output
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
Controlled, isolated DC voltage
Rated voltage value V
out rated
24 V DC 24 V DC 24 V DC
Total tolerance 3 % 3 % 3 %
Static line compensation Approx. 0.1 % Approx. 0.1 % Approx. 0.1 %
Static load compensation Approx. 0.1 % Approx. 0.5 % Approx. 0.5 %
Residual ripple < 50 mV
pp
< 150 mV
pp
(typ. 50 mV
pp
)

< 150 mV
pp
(typ. 50 mV
pp
)
Spikes (bandwidth: 20 MHz) < 200 mV
pp
< 240 mV
pp
(typ. 150 mV
pp
) < 240 mV
pp
(typ. 150 mV
pp
)
Adjustment range 24 ... 28.8 V 22.8 ... 28 V 22.8 ... 28 V
Status display Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
On/off behavior Overshoot of V
out
approx. 3 % Overshoot of V
out
approx. 4 % Overshoot of V
out
approx. 4 %
Startup delay/voltage rise < 1 s/< 50 ms < 0.1 s at 230 V AC/typ. 50 ms < 0.1 s at 230 V AC/typ. 50 ms
Rated current value I
out rated
5 A 5 A 5 A
Current range
Up to +60 C 0 ... 5 A 0 ... 5 A 0 ... 5 A
Derating > 60 C 0 ... 6 A (up to +45 C) 0 ... 6 A (up to +45 C)
Dynamic overcurrent on
Power-up on short circuit Approx. 5.5 A constant current Typ. 17 A for 100 ms Typ. 17 A for 100 ms
Short circuit during operation Typ. 15 A for 25 ms Typ. 17 A for 200 ms Typ. 17 A for 200 ms
Parallel switching for
enhanced performance
Yes, 2 units (switchable
characteristic)
Yes, 2 units Yes, 2 units
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 5 A
5/3
Siemens KT 10.1 2012
5
SITOP lite
PSU100L
SITOP in SIMATIC design
The S7-300 version
SITOP in SIMATIC design
The outdoor version
Special design
The flat design
5 A 5 A 5 A 5 A
6EP1 333-1LB00 6ES7 307-1EA01-0AA0 6ES7 307-1EA80-0AA0
2)
6EP1 333-1AL12
The low-cost power supply for
standard requirements in industrial
environments; slim design; wide-
range input with manual
switchover.
The proven power supply in
SIMATIC S7-300 design; with PS-
CPU connecting comb and for
mounting direct on S7 rail.
The power supply unit for extreme
environmental conditions in
SIMATIC S7-300 design; can be
snapped onto S7 rail; with PS-CPU
connecting comb.
The flat design is of great
advantage where only low
mounting depths are available,
e.g. for use with distributed I/O, in
machine benches or alcoves;
design matched to SIMATIC
ET 200B.
Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12)
SITOP lite
PSU100L
SITOP in SIMATIC design
The S7-300 version
SITOP in SIMATIC design
The outdoor version
Special design
The flat design
1-phase AC 1-phase AC 1-phase AC 1-phase AC
120/230 V AC
Set by means of selector switch
on device
120/230 V AC
Automatic
range switch-over
120/230 V AC
Set by means of selector switch
on device
120/230 V AC
Set by means of selector switch
on device
85 ... 132 V/170 ... 264 V 85 ... 132 V/170 ... 264 V 93 ... 132 V/187 ... 264 V 85 ... 132 V/170 ... 264 V
2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
> 20 ms at V
in
= 93/187 V > 20 ms at V
in
= 93/187 V > 20 ms at V
in
= 93/187 V > 20 ms at V
in
= 93/187 V
50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
2.1/1.15 A 2.3/1.2 A 2.1/1.2 A 2.2/1.2 A
< 32 A, typ. 3 ms < 20 A, < 3 ms < 45 A, < 3 ms < 32 A, < 3 ms
< 0.8 A
2
s < 1.2 A
2
s < 1.8 A
2
s (typ. 1.2 A
2
s) < 0.8 A
2
s
T 3.15 A/250 V (not accessible) T 3.15 A/250 V (not accessible) T 3.15A/250V (not accessible) T 3.15A/250V (not accessible)
From 6 A, characteristic C From 6 A, characteristic C 10 A or higher, characteristic C or
6 A or higher, characteristic D
From 6 A, characteristic C
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
Controlled, isolated DC voltage Controlled, isolated DC voltage
24 V DC 24 V DC 24 V DC 24 V DC
3 % 3 % 3 % 1 %
Approx. 0.1 % Approx. 0.1 % Approx. 0.2 % Approx. 0.1 %
Approx. 0.5 % Approx. 0.5 % Approx. 0.4 % Approx. 0.5 %
< 150 mV
pp
(typ. 50 mV
pp
) < 50 mV
pp
(typ. 10 mV
pp
) < 150 mV
pp
(typ. 40 mV
pp
) < 150 mV
pp
(typ. 40 mV
pp
)
< 240 mV
pp
(typ. 150 mV
pp
) < 150 mV
pp
(typ. 20 mV
pp
) < 240 mV
pp
(typ. 90 mV
pp
) < 240 mV
pp
(typ. 100 mV
pp
)
22.8 ... 26.4 V 22 ... 29 V
Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
Overshoot of V
out
approx. 4 % No overshoot of V
out

(soft start)
No overshoot of V
out
(soft start)
No overshoot of V
out
(soft start)
< 1.5 s/typ. 130 ms < 2 s/typ. 10 ms < 3 s/typ. 100 ms < 2 s/typ. 40 ms
5 A 5 A 5 A 5 A
0 ... 3.5 A 0 ... 5 A 0 ... 5 A 0 ... 5 A
0 ... 5 A (up to +45 C) 0 ... 5 A (up to +70 C)
Typ. 20 A for 100 ms Typ. 20 A for 180 ms Typ. 20 A for 500 ms
Typ. 20 A for 100 ms Typ. 20 A for 80 ms Typ. 20 A for 500 ms
Yes, 2 units Yes Not permitted Yes, 2 units
NEW
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 5 A
5/4
Siemens KT 10.1 2012
5
Technical specifications (continued)
Product SITOP modular SITOP smart SITOP smart
Power supply, type 5 A 5 A 5 A
Order No. 6EP1 333-3BA00 6EP1 333-2AA01 6EP1 333-2BA01
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 87 % Approx. 87 % Approx. 87 %
Power loss at V
out rated
, I
out rated
Approx. 18 W Approx. 17 W Approx. 17 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
Typ. 0.1 % V
out
Typ. 0.3 % V
out
Typ. 0.3 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. +3 % V
out
Typ. 1 % V
out
Typ. 1 % V
out
Load step settling time
50 to 100 % < 5 ms (typ. 2 ms) Typ. 0.2 ms Typ. 0.2 ms
100 to 50 % < 5 ms (typ. 2 ms) Typ. 0.2 ms Typ. 0.2 ms
Protection and monitoring
Output overvoltage protection < 35 V < 33 V < 33 V
Current limitation Typ. 5.5 A Typ. 6.4 ... 6.6 A, overload
capability 150 % I
out

rated
< 5 s/min
Typ. 6.4 ... 6.6 A, overload
capability 150 % I
out

rated
< 5 s/min
Short-circuit protection Alternatively, constant current
characteristic approx. 5.5 A or
latching shutdown
Constant current characteristic Constant current characteristic
Sustained short-circuit current
rms value
Approx. 5.5 A Approx. 10 A Approx. 10 A
Overload/short-circuit indicator LED yellow for "overload", LED red
for "latching shutdown"

Safety
Primary/secondary isolation Yes, safety extra low output voltage
V
out
according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Protection class Class I Class I Class I
Leakage current < 3.5 mA (typ. 0.25 mA) < 3.5 mA (typ. 0.4 mA) < 3.5 mA (typ. 0.4 mA)
Safety test Yes Yes; CB Scheme Yes; CB Scheme
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259
cULus-Listed (UL 508,
CSA C22.2 No. 107.1), File
E197259; cCSAus (CSA C22.2 No.
60950-1, UL 60950-1)
cULus-Listed (UL 508,
CSA C22.2 No. 107.1), File
E197259; cCSAus (CSA C22.2 No.
60950-1, UL 60950-1)
Explosion protection ATEX (available soon) ATEX (EX) II 3G Ex nA II T4; UL
1604 Class I Div. 2 Group ABCD
ATEX (EX) II 3G Ex nA II T4; UL
1604 Class I Div. 2 Group ABCD
FM approval
Marine approval GL and ABS available soon GL GL
Degree of protection
(EN 60529)
IP20 IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation EN 61000-3-2 EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range -25 ... +70 C with natural
convection
0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
Transport/storage temp range -40 ... +85 C -40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L, N, PE One screw-type terminal each for
0.2 ... 2.5 mm
2
solid/finely stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely stranded
Output + 2 screw terminals for 0.2 ... 2.5 mm
2
2 screw terminals for 0.5 ... 2.5 mm
2
2 screw terminals for 0.5 ... 2.5 mm
2
Output 2 screw terminals for 0.2 ... 2.5 mm
2
2 screw terminals for 0.5 ... 2.5 mm
2
2 screw terminals for 0.5 ... 2.5 mm
2
Dimensions (W x H x D) in mm 70 125 125 50 125 125 50 125 125
Weight, approx. 1.2 kg 0.5 kg 0.5 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Accessories
Buffer module (6EP1961-3BA01)
Signaling module (6EP1961-3BA10)

KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 5 A
5/5
Siemens KT 10.1 2012
5
SITOP in SIMATIC design
The S7-300 version
SITOP lite
PSU100L
SITOP in SIMATIC design
The outdoor version
Special design
The flat design
5 A 5 A 5 A 5 A
6ES7 307-1EA01-0AA0 6EP1 333-1LB00 6ES7 307-1EA80-0AA0
2)
6EP1 333-1AL12
Approx. 87 % Approx. 86 % Approx. 84 % Approx. 88 %
Approx. 18 W Approx. 17 W Approx. 23 W Approx. 17 W
Typ. 0.1 % V
out
Typ. 0.3 % V
out
Typ. 0.3 % V
out
Typ. 0.3 % V
out
Typ. 1 % V
out
Typ. 2 % V
out
(I
out
: 10/90/10 %) Typ. 3 % V
out
Typ. 0.5 % V
out
Typ. 0.3 ms Typ. 0.4 ms (10 to 90 %) < 5 ms (typ. 0.2 ms) < 5 ms (typ. 0.1 ms)
Typ. 0.3 ms Typ. 0.4 ms (90 to 10 %) < 5 ms (typ. 0.2 ms) < 5 ms (typ. 0.1 ms)
Additional control loop, shutdown
at < 28.8 V, automatic restart
< 33 V Additional control loop, shutdown
at approx. 30 V, automatic restart
Additional control loop, shutdown
at approx. 33 V, automatic restart
5.5 ... 6.5 A Typically 5.25 A 5.5 ... 6.5 A 5.5 ... 6.5 A
Electronic shutdown, automatic
restart
Constant current characteristic Electronic shutdown, automatic
restart
Electronic shutdown, automatic
restart
< 7 A Approx. 8 A < 5 A < 5 A

Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178, creepage distances
and clearances > 8 mm
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Class I Class I Class I Class I
< 3.5 mA (typ. 0.5 mA) < 3.5 mA (typ. 0.4 mA) < 3.5 mA (typ. 0.3 mA) < 3.5 mA (typ. 0.26 mA)
Notified Body Yes; CB Scheme in preparation Yes Yes
Yes Yes Yes Yes
cULus-listed (UL 508, CSA C22.2
No. 142) File E143289
cULus-Listed (UL 508,
CSA C22.2 No. 107.1) in
preparation
UL-listed (UL 508), file E143289,
CSA (CSA 22.2 No. 142)
cULus-listed (UL 508,
CSA C22.2 No. 107.1),
File E197259
ATEX (EX) II 3G Ex nA II T4; UL
1604 Class I Div. 2 Group ABCD

Class I Div. 2 Group ABCD, T 4
In S7-300 system
IP20 IP20 IP20 IP20
EN 55022 Class B EN 55022 Class A EN 55011 Class A EN 55022 Class B
EN 61000-3-2
EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
-25 ... +70 C with natural
convection
0 ... +60 C with natural
convection
-40 ... +85 C -40 ... +85 C -40 ... +85 C -40 ... +85 C
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K5 acc to EN
60721, with transient condensation
Climate class 3K3 according to
EN 60721, no condensation
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
3 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
60 125 120 50 125 125 80 125 120 160 130 60
0.6 kg 0.5 kg 0.57 kg 0.6 kg
Can be mounted onto S7 rail Snaps onto DIN rail EN 60715
35x7.5/15
Can be mounted onto S7 rail Snaps onto DIN rail EN 60715
35x7.5/15
Mounting adapter for standard
mounting rail (6EP1 971-1BA00)
Mounting adapter for standard
mounting rail
(6ES7390-6BA00-0AA0)

KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 5 A
5/6
Siemens KT 10.1 2012
5
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP modular
120-230/230-500 V AC 24 V DC 5 A 6EP1 333-3BA00
Version with circuit board varnished for protection 6EP1 333-3BA00-8AC0
SITOP smart
120/230 V AC 24 V DC 5 A 6EP1 333-2AA01
120/230 V AC 24 V DC 5 A 6EP1 333-2BA01
SITOP in SIMATIC design,
The S7-300 version
120/230 V AC 24 V DC 5 A 6ES7 307-1EA01-0AA0
SITOP lite, PSU100L
(Planned delivery date:
November 2011)
120/230 V AC 24 V DC 5 A 6EP1 333-1LB00
SITOP in SIMATIC design,
The outdoor version
120/230 V AC 24 V DC 5 A 6ES7 307-1EA80-0AA0
Special design,
The flat design
120/230 V AC 24 V DC 5 A 6EP1 333-1AL12
NEW
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
6
6/2 SITOP PSA100E 6 A
6/2 PSU100D 6.2 A
6/4 Ordering data and additional information
SITOP 1-phase and 2-phase
24 V DC, 6 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 6 A
6/2
Siemens KT 10.1 2012
6
Overview
Technical specifications
Product Special design
PSA100E
Special design
PSU100D
Power supply, type 6 A 6.2 A
Order No. 6EP1 233-1AA00 6EP1 333-1LD00
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
The power supply is optimally designed for standard
requirements in the industrial environment; rugged metal
enclosure; flexible mounting either on standard rails or
directly on a wall; removable terminals.
The low-cost power supply in flat aluminum housing
can be screwed directly on a wall in various mounting
positions; with wide-range input for global use.
Product Special design
PSA100E
Special design
PSU100D
Input
1-phase AC 1-phase AC
Rated voltage value V
in rated
230 V AC 100-240 V AC
Wide-range input
Voltage range 187 ... 264 V 85 ... 264 V
Overvoltage resistance
Mains buffering at I
out rated
> 10 ms > 15 ms at V
in
= 115/230 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
1.4 A 3.1-2.0 A
Switch-on current limit (+25 C) < 35 A < 75 A
I
2
t < 1.2 A
2
s < 6.5 A
2
s
Built-in incoming fuse Internal Internal
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
10 A or higher, characteristic C 10 A or higher, characteristic C or 16 A, characteristic
B
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
24 V DC 24 V DC
Total tolerance 3 % 2 %
Static line compensation Approx. 0.1 % Approx. 0.5 %
Static load compensation Approx. 0.5 % Approx. 1 %
Residual ripple < 150 mV
pp
< 100 mV
pp
Spikes (bandwidth: 20 MHz) < 250 mV
pp
< 100 mV
pp
Adjustment range 23 ... 26 V 22.0 ... 28.0 V
Status display Green LED for 24 V OK Green LED for 24 V OK
On/off behavior Overshoot of V
out
< 5 % Overshoot of V
out
< 2 %
Startup delay /
voltage rise
< 0.3 s/< 500 ms < 1 s/< 30 ms
Rated current value I
out rated
6 A 6.2 A
Current range
Up to +60 C 0 ... 6 A (up to +45 C) 0 ... 6.2 A (up to +50 C)
Derating 0 ... 3 A (up to +70 C) 0 ... 3.1 A (up to +70 C)
Dynamic overcurrent on
Power-up on short circuit
Short circuit during operation
Parallel switching for
enhanced performance
Yes, 2 units Yes, 2 units
NEW
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 6 A
6/3
Siemens KT 10.1 2012
6
Technical specifications (continued)
Product Special design
PSA100E
Special design
PSU100D
Power supply, type 6 A 6.2 A
Order No. 6EP1 233-1AA00 6EP1 333-1LD00
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 87 % Approx. 86 %
Power loss at V
out rated
, I
out rated
Approx. 22 W Approx. 24 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
<0.3 % V
out
Typ. 0.5 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. 2.0 % V
out
Typ. 5.0 % V
out
(0 to 100 %)
Load step settling time
50 at 100 % Typ. 0.1 ms
100 at 50 % Typ. 0.1 ms
Protection and monitoring
Output overvoltage protection < 35 V < 35 V
Current limitation Typ. 6.6 A 7.4 A
Short-circuit protection Electronic shutdown,
automatic restart
Electronic shutdown,
automatic restart
Sustained short-circuit current rms
value
< 3.6 A 16 A
Overload/short-circuit indicator
Safety
Primary/secondary isolation Yes, SELV output voltage V
out
according to
EN 60950-1 and EN 50178
Yes, safety extra low output voltage V
out
according to
EN 60950-1
Protection class Class I Class I
Leakage current < 3.5 mA (typ. 0.8 mA) < 3.5 mA (typ. 1 mA)
Safety test Yes; CB Scheme Yes; CB Scheme in preparation
CE mark Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No.107.1), File
E197259
cULus-Listed (UL 508, CSA C22.2 No.107.1) in
preparation; cURus (UL 60950-1, CSA C22.2
No. 60950-1) in preparation
Explosion protection
FM approval
Marine approval
Degree of protection (EN 60529) IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B
Supply harmonics limitation
Noise immunity EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range -10 ... +70 C with natural convection -10 ... +70 C with natural convection
Transport/storage temperature
range
-40 ... +85 C -25 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L, N, PE Removable screw terminal for
1 0.5 ... 2.5 mm
2
each
One screw-type terminal each for 0.3 ... 1.3 mm
2
solid/finely stranded
Output + Removable screw terminal for 1 0.5 ... 2.5 mm
2
2 screw terminals for 0.3 ... 1.3 mm
2
Output Removable screw terminal for 1 0.5 ... 2.5 mm
2
2 screw terminals for 0.3 ... 1.3 mm
2
Dimensions (W x H x D) in mm 52 170 110 97 x 178 x 38
Weight, approx. 0.9 kg 0.55 kg
Installation Snaps onto DIN rail EN 60715 35x7.5/15.
Wall mounting
Wall mounting
Accessories

KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 6 A
6/4
Siemens KT 10.1 2012
6
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
Special design, PSA100E
230 V AC 24 V DC 6 A 6EP1 233-1AA00
Special design, PSU100D
(Planned delivery date:
December 2011)
100-240 V AC 24 V DC 6.2 A 6EP1 333-1LD00
NEW
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
7
7/2 SITOP modular 10 A
7/2 SITOP smart 10 A
7/3 The S7-300 version 10 A
7/3 SITOP PSU100L 10 A
7/3 The flat design 10 A
7/6 Ordering data and additional information
SITOP 1-phase and 2-phase
24 V DC, 10 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 10 A
7/2
Siemens KT 10.1 2012
7
Overview
Technical data
1)
SIPLUS module see page 15/3.
2)
SITOP modular plus 6EP1 334-3BA00-8AB0, PCB with protective coating.
Product SITOP modular SITOP smart SITOP smart
Power supply, type 10 A 10 A 10 A
Order No. 6EP1 334-3BA00
1)2)
6EP1 334-2AA01 6EP1 334-2BA01
1)
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
Modular power supply with
1-phase and 2-phase wide-range
inputs for global use; with
selectable output characteristic;
functional expansion possible
using add-on modules.
The single-phase power supply for
universal use; complies with EU
directive 94/9/EEC (ATEX 100a);
slim design; with 50 % extra power
for 5 s and 120 % rated power up
to 45 C; without limiting supply
harmonics.
The single-phase power supply for
universal use; complies with EU
directive 94/9/EEC (ATEX 100a);
slim design; with 50 % extra power
for 5 s and 120 % rated power up
to 45 C.
Expansion possibilities Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12)
Product SITOP modular SITOP smart SITOP smart
Input
1-phase and 2-phase AC 1-phase AC 1-phase AC
Rated voltage value V
in rated
120-230/230-500 V AC
Set by means of selector switch
on device
120/230 V AC
Set by means of selector switch
on device
120/230 V AC
Set by means of selector switch
on device
Voltage range 85 ... 264/176 ... 550 V 85 ... 132 V/170 ... 264 V 85 ... 132 V/170 ... 264 V
Overvoltage strength 1300 V
peak
, 1.3 ms 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
Mains buffering at I
out rated
> 25 ms at V
in
= 120/230 V > 20 ms at V
in
= 93/187 V > 20 ms at V
in
= 93/187 V
Rated line frequency; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
4.4-2.4/2.4-1.1 A 4.1/2.4 A 4.1/2.0 A
Switch-on current limit (+25 C) < 35 A < 65 A, typ. 3 ms < 65 A, typ. 3 ms
I
2
t < 4.0 A
2
s < 3.3 A
2
s < 3.3 A
2
s
Built-in incoming fuse T 6.3 A (not accessible) T 6.3 A/250 V (not accessible) T 6.3 A/250 V (not accessible)
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
From 6 A (10 A), Characteristic C
(B); required for 2-phase
operation: Miniature circuit-
breaker 2-pole coupled or circuit-
breaker 3RV2011-1EA10 (setting
3.8 A) or 3RV2711-1ED10 (UL
489) at 230 V; 3RV2011-1DA10
(setting 3 A) or 3RV2711-1DD10
(UL 489) at 400/500 V
10 A or higher, characteristic C 10 A or higher, characteristic C
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
24 V DC 24 V DC 24 V DC
Total tolerance 3 % 3 % 3 %
Static line compensation Approx. 0.1 % Approx. 0.1 % Approx. 0.1 %
Static load compensation Approx. 0.1 % Approx. 0.5 % Approx. 0.5 %
Residual ripple < 50 mV
pp
< 150 mV
pp
(typ. 50 mV
pp
) < 150 mV
pp
(typ. 50 mV
pp
)
Spikes (bandwidth: 20 MHz) < 200 mV
pp
< 240 mV
pp
(typ. 150 mV
pp
) < 240 mV
pp
(typ. 150 mV
pp
)
Adjustment range 24 ... 28.8 V 22.8 ... 28 V 22.8 ... 28 V
Status display Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
On/off behavior Overshoot of V
out
approx. 3 % Overshoot of V
out
approx. 4 % Overshoot of V
out
approx. 4 %
Startup delay/voltage rise < 1 s/< 50 ms < 0.1 s at 230 V AC/typ. 50 ms < 0.1 s at 230 V AC/typ. 50 ms
Rated current value I
out rated
10 A 10 A 10 A
Current range
Up to +60 C 0 ... 10 A 0 ... 10 A 0 ... 10 A
Derating > 60 C 0 ... 12 A (up to +45 C) 0 ... 12 A (up to +45 C)
Dynamic overcurrent on
Power-up on short circuit Approx. 12 A constant current Typ. 30 A for 100 ms Typ. 30 A for 100 ms
Short circuit during operation Typ. 30 A for 25 ms Typ. 33 A for 200 ms Typ. 33 A for 200 ms
Parallel switching for
enhanced performance
Yes, 2 units (switchable
characteristic)
Yes, 2 units Yes, 2 units
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 10 A
7/3
Siemens KT 10.1 2012
7
1)
1)
SIPLUS module see page 15/3.
SITOP in SIMATIC design
The S7-300 version
SITOP lite
PSU100L
Special design
The flat design
10 A 10 A 10 A
6ES7 307-1KA02-0AA0
1)
6EP1 334-1LB00 6EP1 334-1AL12
The proven power supply in
SIMATIC S7-300 design; with PS-
CPU connecting comb and for
mounting direct on S7 rail.
The low-cost power supply for
standard requirements in industrial
environments; slim design; wide-
range input with manual
switchover.
The flat design is of great
advantage where only low
mounting depths are available,
e.g. for use with distributed I/O, in
machine benches or alcoves;
design matched to SIMATIC
ET 200B.
Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12)
NEW
SITOP in SIMATIC design
The S7-300 version
SITOP lite
PSU100L
Special design
The flat design
1-phase AC 1-phase AC 1-phase AC
120/230 V AC
Automatic
range switch-over
120/230 V AC
Set by means of selector switch
on device
120/230 V AC
Set by means of selector switch
on device
85 ... 132 V/170 ... 264 V 85 ... 132 V/170 ... 264 V 85 ... 132 V/170 ... 264 V
2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
> 20 ms at V
in
= 93/187 V > 20 ms at V
in
= 93/187 V > 20 ms at V
in
= 93/187 V
50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
4.2/1.9 A 4.1/2.4 A 4.0/2.5 A
< 55 A, < 3 ms < 65 A, typ. 3 ms < 65 A, < 3 ms
< 3.3 A
2
s < 3.3 A
2
s < 3.3 A
2
s
T 6.3 A/250 V (not accessible) T 6.3 A/250 V (not accessible) T 6.3 A/250 V (not accessible)
10 A or higher, characteristic C 10 A or higher, characteristic C 10 A or higher, characteristic C
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
24 V DC 24 V DC 24 V DC
3 % 3 % 1 %
Approx. 0.1 % Approx. 0.1 % Approx. 0.1 %
Approx. 0.5 % Approx. 0.5 % Approx. 0.5 %
< 50 mV
pp
(typ. 15 mV
pp
) < 150 mV
pp
(typ. 50 mV
pp
) < 150 mV
pp
(typ. 50 mV
pp
)
< 150 mV
pp
(typ. 60 mV
pp
) < 240 mV
pp
(typ. 150 mV
pp
) < 240 mV
pp
(typ. 200 mV
pp
)
22.8 ... 26.4 V 22 ... 29 V
Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
No overshoot of V
out
(soft start) Overshoot of V
out
approx. 4 % No overshoot of V
out
(soft start)
< 2 s/typ. 10 ms < 1.5 s/typ. 170 ms < 2 s/typ. 40 ms
10 A 10 A 10 A
0 ... 10 A 0 ... 7 A 0 ... 10 A
0 ... 10 A (up to +45 C)
Typ. 38 A for 80 ms Typ. 35 A for 700 ms
Typ. 38 A for 80 ms Typ. 35 A for 700 ms
Yes Yes, 2 units Yes, 2 units
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 10 A
7/4
Siemens KT 10.1 2012
7
Technical specifications (continued)
.
Product SITOP modular SITOP smart SITOP smart
Power supply, type 10 A 10 A 10 A
Order No. 6EP1 334-3BA00 6EP1 334-2AA01 6EP1 334-2BA01
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 87 % Approx. 90 % Approx. 91 %
Power loss at V
out rated
, I
out rated
Approx. 36 W Approx. 27 W Approx. 24 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
Typ. 0.1 % V
out
Typ. 0.3 % V
out
Typ. 0.3 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. +3 % V
out
Typ. 1 % V
out
Typ. 1 % V
out
Load step settling time
50 to 100 % < 5 ms (typ. 2 ms) Typ. 0.2 ms Typ. 0.2 ms
100 to 50 % < 5 ms (typ. 2 ms) Typ. 0.2 ms Typ. 0.2 ms
Protection and monitoring
Output overvoltage protection < 35 V <33 V < 33V
Current limitation Typically 12 A Typ. 12.5 ... 13.5 A, overload
capability 150 % I
out

rated
up to
5 s/min
Typ. 12.5 ... 13.5 A, overload
capability 150 % I
out

rated
up to
5 s/min
Short-circuit protection Alternatively, constant current
characteristic approx. 12 A or
latching shutdown
Constant current characteristic Constant current characteristic
Sustained short-circuit current rms
value
Approx. 12 A Approx. 16 A Approx. 16 A
Overload/short-circuit indicator LED yellow for "overload", LED red
for "latching shutdown"

Safety
Primary/secondary isolation Safety extra low output voltage
V
out
according to EN 60950-1 and
EN 50178
Safety extra low output voltage
V
out
according to EN 60950-1 and
EN 50178
Safety extra low output voltage
V
out
according to EN 60950-1 and
EN 50178
Protection class Class I Class I Class I
Leakage current < 3.5 mA (typ. 0.32 mA) < 3.5 mA (typ. 0.8 mA) < 3.5 mA (typ. 0.8 mA)
Safety test Yes Yes; CB Scheme Yes; CB Scheme
CE mark Yes Yes Yes
UL/cUL (CSA) approval Yes, cULus-listed (UL 508,
CSA C22.2 No. 107.1),
File E197259
Yes, cULus-Listed (UL 508, CSA
C22.2 No. 107.1), File E197259;
cCSAus (CSA C22.2
No. 60950-1, UL 60950-1)
Yes, cULus-Listed (UL 508, CSA
C22.2 No. 107.1), File E197259;
cCSAus (CSA C22.2
No. 60950-1, UL 60950-1)
Explosion protection ATEX (available soon) ATEX (EX) II 3G Ex nA II T4;
UL 1604 Class I Div. 2
Group ABCD
ATEX (EX) II 3G Ex nA II T4;
UL 1604 Class I Div. 2
Group ABCD
FM approval
Marine approval GL and ABS available soon GL GL
Degree of protection (EN 60529) IP20 IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation EN 61000-3-2 EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range -25 ... +70 C with natural
convection
0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
Transport/storage temperature
range
-40 ... +85 C -40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L, N, PE One screw-type terminal each for
0.2 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
Output + 2 screw terminals for
0.2 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
Output 2 screw terminals for
0.2 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
Dimensions (W x H x D) in mm 90 125 125 70 125 125 70 125 125
Weight, approx. 1.4 kg 0.75 kg 0.8 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Accessories
Buffer module (6EP1961-3BA01)
Signaling module (6EP1961-3BA10)

KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 10 A
7/5
Siemens KT 10.1 2012
7
1)
SITOP in SIMATIC design
The S7-300 version
SITOP lite
PSU100L
Special design
The flat design
10 A 10 A 10 A
6ES7 307-1KA02-0AA0 6EP1 334-1LB00 6EP1 334-1AL12
Approx. 90 % Approx. 89 % Approx. 89 %
Approx. 27 W Approx. 34 W Approx. 30 W
Typ. 0.1 % V
out
Typ. 0.3 % V
out
Typ. 0.3 % V
out
Typ. 2 % V
out
Typ. 2 % V
out
(I
out
: 10/90/10 %) Typ. 0.6 % V
out
< 0.1 ms Typ. 0.5 ms (10 to 90 %) < 5 ms (typ. 0.1 ms)
< 0.1 ms Typ. 0.7 ms (90 to 10 %) < 5 ms (typ. 0.2 ms)
Additional control loop, shutdown
at < 28.8 V, automatic restart
<33V Additional control loop, shutdown
at approx. 33 V, automatic restart
11 ... 12 A Typically 10.5 A 11 ... 13 A
Electronic shutdown, automatic
restart
Constant current characteristic Electronic shutdown, automatic
restart
< 12 A Approx. 16 A < 10 A

Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Safety extra low output voltage
V
out
according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Class I Class I Class I
< 3.5 mA (typ. 0.6 mA) < 3.5 mA (typ. 0.8 mA) < 3.5 mA (typ. 0.27 mA)
Yes Yes; CB Scheme in preparation Yes
Yes Yes Yes
cULus-listed (UL 508,
CSA C22.2 No. 142), File E143289
cULus-listed (UL 508, CSA C22.2
No. 107.1) available soon
cULus-Listed (UL 508,
CSA C22.2 No. 107.1,
File E197259
ATEX (EX) II 3G Ex nA II T4; UL
1604 Class I Div. 2
Group ABCD

Class I Div. 2. Group ABCD, T4
in S7-300 system
IP20 IP20 IP20
EN 55022 Class B EN 55022 Class A EN 55022 Class B
EN 61000-3-2
EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
-40 ... +85 C -40 ... +85 C -40 ... +85 C
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
4 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
4 screw terminals for
0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
3 screw terminals for
0.5 ... 2.5 mm
2
80 125 120 70 125 125 160 130 60
0.8 kg 0.75 kg 0.72 kg
Can be mounted onto S7 rail Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Mounting adapter for standard
mounting rail (6EP1 971-1BA00)

KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 10 A
7/6
Siemens KT 10.1 2012
7
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP modular
120-230/230-500 V AC 24 V DC 10 A 6EP1 334-3BA00
Version with circuit board varnished for protection 6EP1 334-3BA00-8AB0
SITOP smart
120/230 V AC 24 V DC 10 A 6EP1 334-2AA01
120/230 V AC 24 V DC 10 A 6EP1 334-2BA01
SITOP in SIMATIC design,
The S7-300 version
120/230 V AC 24 V DC 10 A 6ES7 307-1KA02-0AA0
SITOP lite, PSU100L
(Planned delivery date:
November 2011)
120/230 V AC 24 V DC 10 A 6EP1 334-1LB00
Special design,
The flat design
120/230 V AC 24 V DC 10 A 6EP1 334-1AL12
NEW
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
8
8/2 SITOP PSA100E 12 A
8/2 PSU100D 12.5 A
8/2 SITOP PSU100M 20 A
8/3 SITOP PSU400M 20 A
8/3 SITOP modular 20 A
8/3 SITOP modular 40 A
8/8 Ordering data and additional information
SITOP 1-phase and 2-phase
24 V DC, 12 to 40 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 12 to 40 A
8/2
Siemens KT 10.1 2012
8
Overview
Technical specifications
1)
At V
in
< 100 V AC or DC: Temperature-derating to +50 C required.
Product Special design
PSA100E
Special design
PSU100D
SITOP modular
PSU100M
Power supply, type 12 A 12.5 A 20 A
Order No. 6EP1 234-1AA00 6EP1 334-1LD00 6EP1 336-3BA10
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
The power supply is optimally
tailored to standard requirements in
the industrial environment; rugged
metal enclosure; flexible mounting
either on standard rails or directly on
a wall; removable terminals.
The low-cost power supply in flat
aluminum housing can be screwed
directly on a wall in various
mounting positions;
with wide-range input for global use.
Modular power supply with 1-phase
and 2-phase input, for global use,
slim design, with 50 % extra power
for 5 s/min and switchable output
characteristic; function expansion
possible using additional modules
Expansion possibilities Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12)
Product Special design
SITOP PSA100E
Special design
PSU100D
SITOP modular
PSU100M
Input
1-phase AC 1-phase AC 1-phase/2-phase AC
Rated voltage value V
in rated
230 V AC 100-240 V AC
Wide-range input
120-230 V AC
wide-range input
Voltage range 187 ... 264 V 85 ... 264 V AC 85 ... 275 V or
DC 88 ... 350 V
1)
Overvoltage resistance With internal varistors
Mains buffering at I
out rated
> 10 ms > 15 ms at V
in
= 115/230 V > 20 ms at V
in
= 230 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 45 ... 65 Hz
Rated current I
in rated
2.5 A 4.0-2.0 A 4.6/2.5 A
Switch-on current limit (+25 C) < 50 A < 60 A < 20 A
I
2
t < 3.3 A
2
s < 1.1 A
2
s < 5 A
2
s
Built-in incoming fuse Internal Internal Yes
Recommended miniature circuit
breaker
(IEC 898) in the mains power input
10 A or higher, characteristic C 10 A or higher, characteristic C or
16 A, characteristic B
10 A, char. C (2-pole-linked with 2-
phase operation) or circuit breaker
(8 or 4 A) according to UL489:
3RV2711-1HD10 (120 V) or
3RV2711-1ED10 (230 V)
Output
Controlled, isolated DC voltage Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
Rated voltage V
out rated
24 V DC 24 V DC 24 V DC
Total tolerance 3 % 2 % 3 %
Static line compensation Approx. 0.1 % Approx. 0.5 % Approx. 0.1 %
Static load compensation Approx. 0.5 % Approx. 0.5 % Approx. 0.3 %
Residual ripple < 150 mV
pp
< 100 mV
pp
< 100 mV
pp
(typ. 80 mV
pp
)
Spikes (bandwidth: 20 MHz) < 250 mV
pp
< 100 mV
pp
< 200 mV
pp
(typ. 100 mV
pp
)
Adjustment range 23 ... 26 V 22.0 ... 28.0 V 24 ... 28.8 V
Status display Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
Signaling Relay contact (NO contact,
rating 60 V DC/0.3 A) for 24 V OK
On/off behavior Overshoot of V
out
< 5 % Overshoot of V
out
< 2 % No overshoot of V
out

(soft start)
Startup delay/voltage rise < 0.3 s/< 500 ms 1 s/< 30 ms < 0.25 s/< 15 ms
Rated current value I
out rated
12 A 12.5 A 20 A
NEW NEW
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 12 to 40 A
8/3
Siemens KT 10.1 2012
8
2)
SITOP modular plus 6EP1 336-3BA00-8AC0, PCB with protective coating.
3)
SIPLUS module see page 15/3.
SITOP modular
PSU400M
SITOP modular SITOP modular
20 A 20 A 40 A
6EP1 536-3AA00 6EP1 336-3BA00
2) 3)
6EP1 337-3BA00
3)

Power supply SITOP PSU400M with 600 V DC
input constitutes an efficient DC/DC converter
for drives and battery systems; wide input and
temperature range, high efficiency, slim design;
with 50 % extra power for 5 s/min, and with
switchable output characteristics.
The modular power supply units with 1-phase
and 2-phase inputs for global use; with
switchable output characteristics; functional
expansion possible using expansion modules.
The modular power supply units with 1-phase
and 2-phase inputs for global use; with
switchable output characteristics; functional
expansion possible using expansion modules.
Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12)
SITOP modular
PSU400M
SITOP modular SITOP modular
DC voltage 1-phase/2-phase AC 1-phase/2-phase AC
600 V DC 120/230 V AC
Set by means of wire jumper on the device
120/230 V AC
Set by means of wire jumper on the device
200 ... 900 V DC (startup from approx. 400 V DC)
Derating: 200 ... 300 V DC and 820 ... 900 V DC
85 ... 132/176 ... 264 V
(startup from V
in
> 93/183 V)
85 ... 132/176 ... 264 V
(startup from V
in
> 95/190 V)
Shutdown at V
in
> DC 900 V 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
> 20 ms at V
in
= 230 V > 20 ms at V
in
= 230 V
50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
0.85 A 7.7/3.5 A 15.0/8.0 A
< 8 A (V
in
slew rate 1 V/s) < 60 A < 125 A
< 0.02 A
2
s < 9.9 A
2
s < 26 A
2
s
Yes, cut-off capacity 20 kA; L/R < 2 ms
("+" and "" input)
Yes Yes
10 A, characteristic C (2-pole-linked with
2-phase operation) or circuit breaker
3RV2411-1JA10 (120 V) or 3RV2411-1FA10
(230 V)
20 A, characteristic C (2-pole-linked with
2-phase operation) or circuit breaker
3RV2421-4BA10 (120 V) or 3RV2411-1JA10
(230 V)
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
24 V DC 24 V DC 24 V DC
3 % 3 % 3 %
Approx. 0.3 % Approx. 0.1 % Approx. 0.1 %
Approx. 0.3 % Approx. 0.1 % Approx. 0.1 %
< 150 mV
pp
(typ. 30 mV
pp
) < 100 mV
pp
(typ. 30 mV
pp
) < 100 mV
pp
(typ. 60 mV
pp
)
< 200 mV
pp
(typ. 100 mV
pp
) < 200 mV
pp
(typ. 60 mV
pp
) < 200 mV
pp
(typ. 120 mV
pp
)
24 ... 28.8 V 24 ... 28.8 V (max. 480 W) 24 ... 28.8 V (max. 960 W)
Green LED for 24 V OK
Green flashing LED for start delay
Green LED for 24 V OK Green LED for 24 V OK
Relay contact (NO, rating DC 60 V/0.3 A,
30 V DC/1 A) for 24 V OK
Via signaling module
(6EP1961-3BA10)
Via signaling module
(6EP1961-3BA10)
No overshoot of V
out
(soft start) Overshoot of V
out
approx. 3 % Overshoot of V
out
approx. 3 %
<100 ms; 10 s adjustable with selector switch/
< 150 ms
< 0.1 s/< 50 ms < 0.1 s/< 50 ms
20 A 20 A 40 A
NEW
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 12 to 40 A
8/4
Siemens KT 10.1 2012
8
Technical specifications (continued)
Product Special design
PSA100E
Special design
PSU100D
SITOP modular
PSU100M
Power supply, type 12 A 12.5 A 20 A
Order No. 6EP1 234-1AA00 6EP1 334-1LD00 6EP1 336-3BA10
Output (continued)
Current range
Up to +60 C 0 ... 12 A (up to +45 C) 0 ... 12.5 A (up to +50 C) 0 ... 20 A
Derating 0 ... 6 A (up to +70 C) 0 ... 6.2 A (up to +70 C) > 60 C
Dynamic overcurrent on
Power-up on short circuit 30 A
Short circuit during operation Typ. 60 A for 25 ms
Parallel switching for enhanced
performance
Yes, 2 units Yes, 2 units Yes, 2 units (with switchable
characteristic)
Efficiency
Efficiency
at V
out rated
, I
out rated
ca. 88 % Approx. 86% Approx. 93 %
Power loss
at V
out rated
, I
out rated
Approx. 39 W Approx. 48 W Approx. 42 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
<0.3 % V
out
Typ. 0.5 % V
out
<0.5 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. 3.5 % V
out
Typ. 5 % V
out
(0 to 100 %) Typ. 1 % V
out
Load step settling time
50 to 100 % Typ. 0.1 ms < 5 ms (typ. 1 ms)
100 to 50 % Typ. 0.1 ms < 5 ms (typ. 1 ms)
Protection and monitoring
Output overvoltage protection < 35 V < 35 V < 33 V
Current limitation Typically 13.2 A 15 A Typ. 21.5 A, overload capability
150 % I
out rated
to 5 s/min
Short-circuit protection Electronic shutdown, automatic
restart
Electronic shutdown, automatic
restart
Alternatively, constant current
characteristic approx. 23 A or
latching shutdown
Sustained short-circuit current rms
value
< 7.5 A 15 A Approx. 23 A
Overload/short-circuit indicator Yellow LED for Overload, Red
LED for latching shutdown
Safety
Primary/secondary isolation Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, safety extra low output
voltage V
out
according to
EN 60950-1
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Protection class Class I Class I Class I
Leakage current < 3.5 mA (typ. 0.8 mA) < 3.5 mA (typ. 1 mA) < 3.5 mA
Safety test Yes; CB scheme Yes; CB Scheme in preparation Yes
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259
cULus-Listed (UL 508,
CSA C22.2 No. 107.1) in
preparation; cURus (UL 60950-1,
CSA C22.2 No. 60950-1)
in preparation
cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259
Explosion protection ATEX (available soon)
Marine approval GL and ABS available soon
Degree of protection (EN 60529) IP20 IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation EN 61000-3-2 EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range -10 ... +70 C with natural
convection
-10 ... +70 C with natural
convection
-25 ... +70 C with natural
convection
Transport/storage temperature
range
-40 ... +85 C -25 ... +85 C - 40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 12 to 40 A
8/5
Siemens KT 10.1 2012
8
SITOP modular
PSU400M
SITOP modular SITOP modular
20 A 20 A 40 A
6EP1 536-3AA00 6EP1 336-3BA00 6EP1 337-3BA00
0 ... 20 A 0 ... 20 A 0 ... 40 A
0 ... 9 A (up to +70 C) > 60 C > 60 C
Approx. 40 A for 150 ms Approx. 23 A constant current Approx. 46 A constant current
Typ. 60 A for 25 ms Typ. 120 A for 25 ms
P Yes, (switchable characteristic) Yes, 2 units (switchable characteristic) Yes, 2 units (switchable characteristic)
Approx. 95 % Approx. 89 % Approx. 88 %
Approx. 25 W Approx. 59 W Approx. 131 W
<1.5 % V
out
<1% V
out
<1% V
out
Typ. 1.5 % V
out
Typ. 2 % V
out
Typ. 2 % V
out
< 5 ms (typ. 1 ms) < 5 ms (typ. 2 ms) < 5 ms (typ. 2 ms)
< 5 ms (typ. 1 ms) < 5 ms (typ. 2 ms) < 5 ms (typ. 2 ms)
< 33 V < 35 V < 35 V
Typ. 22 A, overload capability 150 % I
out rated
to
5 s/min
Typ. 23 A Typically 46 A
Alternatively, constant current characteristic
approx. 22 A or latching shutdown
Alternatively, constant current characteristic
approx. 23 A or latching shutdown
Alternatively, constant current characteristic
approx. 46 A or latching shutdown
Approx. 22 A Approx. 23 A Approx. 46 A
Yellow LED for Overload, red LED for
latching shutdown, Red LED flashing for
"overtemperature"
Yellow LED for Overload, Red LED for
latching shutdown
Yellow LED for Overload, Red LED for
latching shutdown
Yes, SELV output voltage V
out

according to EN 60950-1 and EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and EN 50178
Class I Class I Class I
< 3.5 mA (typ. 0.4 mA) < 3.5 mA (typ. 0.4 mA)
Yes Yes Yes
Yes Yes Yes
cULus-Listed (UL 508, CSA C22.2 No. 107.1),
File E197259
cULus-listed (UL 508, CSA C22.2 No. 107.1),
File E197259
cULus-listed (UL 508, CSA C22.2 No. 107.1),
File E197259
IP20 IP20 IP20
ATEX (available soon)
GL and ABS available soon GL and ABS available soon
EN 55022 Class A (radiated emission) EN 55022 Class B EN 55022 Class B
EN 61000-3-2
EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
-25 ... +70 C with natural convection 0 ... +70 C with natural convection 0 ... +70 C with natural convection
-40 ... +85 C -40 ... +85 C -40 ... +85 C
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 12 to 40 A
8/6
Siemens KT 10.1 2012
8
Technical specifications (continued)
Product Special design
PSA100E
Special design
PSU100D
SITOP modular
PSU100M
Power supply, type 12 A 12.5 A 20 A
Order No. 6EP1 234-1AA00 6EP1 334-1LD00 6EP1 336-3BA10
Mechanics
Connections
DC input +, , PE
Supply input L, N, PE Removable screw terminal for
1 0.5 ... 2.5 mm
2
each
One screw-type terminal each for
0.5 ... 1.3 mm
2
solid/finely
stranded
One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
Output + Removable screw terminal for
1 0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 1.3 mm
2
2 screw terminals for
0.2 ... 4 mm
2
Output Removable screw terminal for
1 0.5 ... 2.5 mm
2
2 screw terminals for
0.5 ... 1.3 mm
2
2 screw terminals for
0.2 ... 4 mm
2
Alarm signals 2 screw terminals for
0.14 ... 1.5 mm
2
Dimensions (W x H x D) in mm 52 170 110 105 199 41 90 125 125
Weight, approx. 0.9 kg 0.81 kg 1.2 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15. Wall mounting
Wall mounting Snaps onto DIN rail EN 60715
35x7.5/15
Accessories
Buffer module (6EP1961-3BA01)
Device labeling plates
(3RT1900-1SB20)
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 12 to 40 A
8/7
Siemens KT 10.1 2012
8
SITOP modular
PSU400M
SITOP modular SITOP modular
20 A 20 A 40 A
6EP1 536-3AA00 6EP1 336-3BA00 6EP1 337-3BA00
One screw-type terminal each for
0.2 ... 6/4 mm
2
solid/finely stranded

One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
2 screw terminals for
0.2 ... 6/4 mm
2
solid/finely stranded
2 screw terminals for
0.5 ... 4 mm
2
2 screw terminals for
0.5 ... 10 mm
2
2 screw terminals for
0.2 ... 6/4 mm
2
solid/finely stranded
2 screw terminals for
0.5 ... 4 mm
2
2 screw terminals for
0.5 ... 10 mm
2
2 screw terminals for
0.14 ... 1.5 mm
2

90 125 125 160 125 125 240 125 125
1.2 kg 2.2 kg 2.9 kg
Snaps onto DIN rail
EN 60715 357.5/15
Snaps onto DIN rail
EN 60715 357.5/15
Snaps onto DIN rail
EN 60715 357.5/15
Unit labeling plates
(3RT1900-1SB20)
Buffer module (6EP1961-3BA01)
Signaling module (6EP1961-3BA10)
Buffer module (6EP1961-3BA01)
Signaling module (6EP1961-3BA10)
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 1-phase and 2-phase
24 V DC
Output current 12 to 40 A
8/8
Siemens KT 10.1 2012
8
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
Special design, PSA100E
230 V AC 24 V DC 12 A 6EP1 234-1AA00
Special design, PSU100D
(Planned delivery date:
December 2011)
100-240 V AC 24 V DC 12.5 A 6EP1 334-1LD00
SITOP modular, PSU100M
120 - 230 V AC 24 V DC 20 A 6EP1 336-3BA10
SITOP modular, PSU400M
600 V DC 24 V DC 20 A 6EP1 536-3AA00
SITOP modular
120/230 V AC 24 V DC 20 A 6EP1 336-3BA00
Version with circuit board varnished for protection 6EP1 336-3BA00-8AA0
SITOP modular
120/230 V AC 24 V DC 40 A 6EP1 337-3BA00
NEW
NEW
NEW
KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
9
9/2 SITOP modular 5 A
9/2 SITOP PSU300P 8 A
9/2 SITOP modular 10 A
9/3 SITOP PSU300S 10 A
9/3 SITOP PSU300M 20 A
9/3 SITOP modular 20 A
9/3 SITOP PSU300S 20 A
9/6 Ordering data and additional information
SITOP 3-phase
24 V DC, 5 to 20 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 5 to 20 A
9/2
Siemens KT 10.1 2012
9
Overview
Technical specifications
1)
Available with a second plug connector for loop-through of the input voltage as 2) SIPLUS module see page 15/4
SIMATIC ET 200pro PS (6ES7148-4PC00-0HA0), output "PELV".
Product SITOP modular Special design
PSU300P
SITOP modular
Power supply, type 5 A 8 A 10 A
Order No. 6EP1 333-3BA00
2)
6EP1 433-2CA00 6EP1 334-3BA00
2)
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
The modular power supply units
with wide-range input for
2-phase connection to three-
phase supply networks; for
global use; with switchable output
characteristics; functional
expansion possible using
expansion modules.
The power supplies with IP67 degree
of protection, SITOP PSU300P and
SIMATIC ET 200pro PS
1)
, serve as
electronics/encoder and load power
supplies for the new I/O device.
With a signaling contact for "24 V
OK" and "Overtemperature", and in
the case of SIMATIC ET 200pro with
a second plug-in connector for
input voltage loop-through.
The modular power supply units
with wide-range input for
2-phase connection to three-
phase supply networks; for
global use; with switchable output
characteristics; functional
expansion possible using
expansion modules.
Expansion possibilities Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12).
Product SITOP modular Special design PSU300P SITOP modular
Input
2-phase AC 3-phase AC 2-phase AC
Rated voltage value V
in rated
120-230/230-500 V 2 AC
Set with selector switch on device
400-480 V 3 AC
Wide-range input
120-230/230-500 V 2 AC
Set with selector switch on device
Voltage range 85 ... 264/176 ... 550 V 340 ... 550 V
(320 ... 340 V for max. 1 min)
85 ... 264/176 ... 550 V
Overvoltage resistance 1300 V
peak
, 1.3 ms Internal, with varistors 1300 V
peak
, 1.3 ms
Mains buffering at I
out rated
Typ. 150 ms at V
in
= 400 V > 15 ms at V
in
= 400 V Typ. 120 ms at V
in
= 400 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 45 ... 66 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
2.2-1.2/1.2-0.61 A 0.5 A (at V
in
400 V) 4.4-2.4/2.4-1.1 A
Switch-on current limit (+25 C) < 35 A < 40 A < 35 A
I
2
t < 1.7 A
2
s < 3.5 A
2
s < 4.0 A
2
s
Built-in incoming fuse T 3.15 A Intern, 4 A T 6.3 A
Required protection in the main
supply conductor
From 6 A (10 A) characteristic C
(B); required for two-phase
operation: Miniature circuit-
breaker 2-pole coupled or circuit-
breaker 3RV2011-1EA10 (setting
3.8 A) or 3RV2711-1ED10 (UL
489) at 230 V; 3RV2011-1DA10
(setting 3 A) or 3RV2711-1DD10
(UL 489) at 400/500 V
Circuit breaker 2.2 ... 3.2 A
3RV2011-1DA10 or
3RV2711-1DD10 (UL 489)
From 6 A (10 A) characteristic C
(B); required for two-phase
operation: Miniature circuit-
breaker 2-pole coupled or circuit-
breaker 3RV2011-1EA10 (setting
3.8 A) or 3RV2711-1ED10
(UL 489) at 230 V; 3RV2011-
1DA10 (setting 3 A) or 3RV2711-
1DD10 (UL 489) at 400/500 V
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
24 V DC 24 V DC 24 V DC
Total tolerance 3 % < 3 ... -5 % 3 %
Static line compensation Approx. 0.1 % Approx. 0.5 % Approx. 0.1 %
Static load compensation Approx. 0.1 % Approx. 0.5 % Approx. 0.1 %
Residual ripple < 50 mV
pp
< 200 mV
pp
< 50 mV
pp

Spikes (bandwidth: 20 MHz) < 200 mV
pp
< 250 mV
pp
< 200 mV
pp

Adjustment range 24 ... 28.8 V (max. 120 W) 24 ... 28.8 V (max. 240 W)
Status display Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
Signaling Use signaling module
(6EP1961-3BA10)
Power Good (high level 1L+ for
V
out
in range 21.3 ... 29 V)
Overtemperature warning at
least 30 s before switch-off (High
level 1L+ when the max. internal
temperature is exceeded)
Use signaling module
(6EP1961-3BA10)
On/off behavior Overshoot of V
out
approx. 3 % Overshoot of V
out
<2 % Overshoot of V
out
approx. 3 %
Startup delay/voltage rise < 1 s/< 50 ms < 1.5 s/< 400 ms < 1 s/< 50 ms
Rated current value I
out rated
5 A 8 A 10 A
Current range
Up to +60 C 0 ... 5 A 0 ... 8 A (up to +55 C) 0 ... 10 A
Derating > 60 C > 60 C
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 5 to 20 A
9/3
Siemens KT 10.1 2012
9

2)
SITOP modular plus 6EP1 436-3BA00-8AA0, PCB with protective coating.
3)
SIPLUS module see page 15/4..
SITOP smart
PSU300S
SITOP modular
PSU300M
SITOP modular SITOP smart
PSU300S
10 A 20 A 20 A 20 A
6EP1 434-2BA10 6EP1 436-3BA10 6EP1 436-3BA00
2) 3)
6EP1 436-2BA10
Powerful standard power supply
with three-phase wide-range input
for global use; high overload
capability with 50 % extra power
for 5 s/min. It also tolerates 1.2
times the rated current at ambient
temperatures under +45 C.
Modular power supply with three-
phase wide-range input for global
use; slim design; with 50 % extra
power for 5 s/min and switchable
output characteristic; expansion
possible using additional
modules.
Modular power supply with three-
phase wide-range input for global
use; with switchable output
characteristic; expansion possible
using additional modules.
Powerful standard power supply
with three-phase wide-range input
for global use; high overload
capability with 50 % extra power
for 5 s/min. It also tolerates 1.2
times the rated current at ambient
temperatures under +45 C.
This power supply is shown on the
title page of this catalog.
Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12).
SITOP smart
PSU300S
SITOP modular
PSU300M
SITOP modular SITOP smart
PSU300S
3-phase AC 3-phase AC 3-phase AC 3-phase AC
400-500 V AC
Wide-range input
400-500 V 3 AC
Wide-range input
400-500 V 3 AC
wide-range input
400-500 V AC
Wide-range input
340 ... 550 V 320 ... 575 V 320 ... 550 V
(startup from V
in
> 340 V)
340 ... 550 V
2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
> 6 ms/typ. 14 ms at V
in
= 400 V > 15 ms at V
in
= 400 V > 6 ms at V
in
= 400 V > 6 ms at V
in
= 400 V
50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
0.7-0.5 A 1.2-1.0 A 1.1-0.9 A 1.2-1.0 A
< 36 A < 18 A < 35 A < 36 A
< 0.9 A
2
s
< 0.8 A
2
s < 0.7 A
2
s < 0.9 A
2
s
None None None None
3-pole connected miniature circuit
breaker 6 ... 16 A, characteristic C
or circuit breaker 3RV2011-1DA10
(set to 3 A) or 3RV2711-1DD10
(UL 489)
3-pole connected miniature circuit
breaker 6 ... 16 A, characteristic C
or circuit breaker 3RV2011-1DA10
(set to 3 A) or 3RV2711-1DD10
(UL 489)
3-pole connected miniature circuit
breaker 6 ... 16 A, characteristic C
or circuit breaker 3RV2011-1DA10
(set to 3 A) or 3RV2711-1DD10
(UL 489)
3-pole connected miniature circuit
breaker 6 ... 16 A, characteristic C
or circuit breaker 3RV2011-1DA10
(set to 3 A) or 3RV2711-1DD10
(UL 489)
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
24 V DC 24 V DC 24 V DC 24 V DC
3 % 3 % 3 % 3 %
Approx. 0.5 % Approx. 0.1 % Approx. 0.1 % Approx. 0.5 %
Approx. 1 % Approx. 0.2 % Approx. 0.2 % Approx. 1 %
< 150 mV
pp
< 100 mV
pp
< 100 mV
pp
< 150 mV
pp
< 240 mV
pp
< 200 mV
pp
< 200 mV
pp
< 240 mV
pp
24 ... 28.0 V (max. 240 W) 24 ... 28.8 V (max. 480 W) 24 ... 28.8 V (max. 480 W) 24 ... 28.0 V (max. 480 W)
Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK Green LED for 24 V OK
Relay contact (NO contact,
contact rating 60 V DC/0.3 A)
for 24 V OK
Relay contact (NO contact,
contact rating 60 V DC/0.3 A)
for 24 V OK
Use signaling module
(6EP1961-3BA10)
Relay contact (NO contact,
contact rating 60 V DC/0.3 A)
for 24 V OK
No overshoot of V
out
(soft start) No overshoot of V
out
(soft start) No overshoot of V
out
(soft start) No overshoot of V
out
(soft start)
< 1.5 s/typ. 30 ms < 2.5 s/< 500 ms < 2.5 s/< 500 ms < 1.5 s/typ. 30 ms
10 A 20 A 20 A 20 A
0 ... 10 A (up to +70 C) 0 ... 20 A 0 ... 20 A 0 ... 20 A
12 A (up to +45 C) 14 A (up to +70 C) > 60 C 24 A (up to +45 C) 10 A
(up to +70 C)
NEW NEW
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 5 to 20 A
9/4
Siemens KT 10.1 2012
9
Product SITOP modular Special design
PSU300P
SITOP modular
Power supply, type 5 A 8 A 10 A
Order No. 6EP1 333-3BA00 6EP1 433-2CA00 6EP1 334-3BA00
Output
Dynamic overcurrent on
Power-up on short circuit Approx. 5.5 A constant current Approx. 50 A for 100 ms Approx. 12 A constant current
Short circuit during operation Typ. 15 A for 25 ms Approx. 50 A for 100 ms Typ. 30 A for 25 ms
Parallel switching for
enhanced performance
Yes, 2 units
(switchable characteristic)
No Yes, 2 units
(switchable characteristic)
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 87 % Typically 88 % Approx. 87 %
Power loss at V
out rated
, I
out rated
Approx. 18 W Typ. 25 W Approx. 36 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
Typ. 0.1 % V
out
Approx. 0.5 % V
out
Typ. 0.1 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. +3 % V
out
Typ. 1 % V
out
Typ. +3 % V
out
Load step settling time
50 to 100 % < 5 ms (typ. 2 ms) < 2 ms < 5 ms (typ. 2 ms)
100 to 50 % < 5 ms (typ. 2 ms) < 2 ms < 5 ms (typ. 2 ms)
Protection and monitoring
Output overvoltage protection < 35 V < 33 V < 35 V
Current limitation Typically 5.5 A Typically 9.4 A Typically 12 A
Short-circuit protection Alternatively, constant current
characteristic approx. 5.5 A or
latching shutdown
Electronic shutdown, automatic
restart
Alternatively, constant current
characteristic approx. 12 A or
latching shutdown
Sustained short-circuit rms value Approx. 5.5 A < 10 A Approx. 12 A
Overload/short-circuit indicator LED yellow for "overload", LED red
for "latching shutdown"
LED yellow for "overload", LED red
for "latching cutoff"
Safety
Primary/secondary isolation Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Protection class Class I Class I Class I
Leakage current < 3.5 mA (typ. 0.25 mA) < 3.5 mA < 3.5 mA (typ. 0.32 mA)
Safety test Yes Yes; CB scheme Yes
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259
In preparation: UL-Listed (UL 508) cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259
Explosion protection ATEX (available soon) ATEX (available soon)
Marine approval GL and ABS available soon GL and ABS available soon
Degree of protection (EN 60529) IP20 IP67, enclosure type 4 indoor IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class A EN 55022 Class B
Supply harmonics limitation EN 61000-3-2 EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range -25 ... +70 C with natural
convection
-25 ... +55 C with natural
convection
-25 ... +70 C with natural
convection
Transport and storage temperature -40 ... +85 C -40 ... +70 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L1, L2. L3, PE One screw-type terminal each for
0.2 ... 2.5 mm
2
solid/finely
stranded
Plug connector HAN Q4/2 One screw-type terminal each for
0.2 ... 2.5 mm
2
solid/finely
stranded
Output + 2 screw terminals for
0.2 ... 2.5 mm
2
1 2.5 mm
2
(2-pole cable for +/-
with open, labeled ends,
2 2.5 mm
2
)
2 screw terminals for
0.2 ... 2.5 mm
2
Output 2 screw terminals for
0.2 ... 2.5 mm
2
1 2.5 mm
2
(2-pole cable for +/-
with open, labeled ends,
2 2.5 mm
2
)
2 screw terminals for
0.2 ... 2.5 mm
2
Alarm signals M12 plug-in connector, 5-pin
Dimensions (W x H x D) in mm 70 125 125 310 135 90
+ additional height of connector
90 125 125
Weight, approx. 1.2 kg 2.8 kg 1.4 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
Can be mounted onto ET 200pro
mounting rail
Snaps onto DIN rail EN 60715
35x7.5/15
Accessories
Buffer module (6EP1961-3BA01)
Signaling module
(6EP1961-3BA10)
Power connector
(3RK1911-2BE50 (2.5 mm
2
))
Buffer module (6EP1961-3BA01)
Signaling module
(6EP1961-3BA10)
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 5 to 20 A
9/5
Siemens KT 10.1 2012
9
SITOP smart
PSU300S
SITOP modular
PSU300M
SITOP modular SITOP smart
PSU300S
10 A 20 A 20 A 20 A
6EP1 434-2BA10 6EP1 436-3BA10 6EP1 436-3BA00 6EP1 436-2BA10
Approx. 16 A for 100 ms Approx. 23 A constant current Approx. 23 A constant current Approx. 35 A for 100 ms
Approx. 16 A for 100 ms Typ. 60 A for 25 ms Typ. 60 A for 25 ms Approx. 35 A for 100 ms
Yes, 2 units Yes, 2 units
(switchable characteristic)
Yes, 2 units
(switchable characteristic)
Yes, 2 units
Approx. 91 % Approx. 93 % Approx. 90 % Approx. 91 %
Approx. 24 W Approx. 36 W Approx. 53 W Approx. 47 W
<3 % V
out
<1% V
out
<1% V
out
<3 % V
out
Typ. 3 % V
out
Typ. 2 % V
out
Typ. 2 % V
out
Typ. 3 % V
out
< 10 ms (typ. 2 ms) < 10 ms (typ. 2 ms) < 10 ms (typ. 4 ms) < 10 ms (typ. 2 ms)
< 10 ms (typ. 2 ms < 10 ms (typ. 2 ms) < 10 ms (typ. 4 ms) < 10 ms (typ. 2 ms
Yes, according to EN 60950 < 35 V < 35 V Yes, according to EN 60950
Typ. 11 A, overload capability
150 % I
out

rated
up to 5 s/min
Typ. 23 A, overload capability
150 % I
out

rated
up to 5 s/min
Typically 23 A Typ. 25 A, overload capability
150 % I
out

rated
up to 5 s/min
Electronic shutdown, automatic
restart
Alternatively, constant current
characteristic approx. 23 A or
latching shutdown
Alternatively, constant current
characteristic approx. 23 A or
latching shutdown
Electronic shutdown, automatic
restart
Approx. 3.2 A Approx. 23 A Approx. 23 A Approx. 7 A
LED yellow for "overload", LED red
for "latching cutoff"
LED yellow for "overload", LED red
for "latching cutoff"

Yes, SELV output voltage V


out
according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out
according to EN 60950-1 and
EN 50178
Class I Class I Class I Class I
< 3.5 mA (typ. 1 mA) < 3.5 mA < 3.5 mA < 3.5 mA mA (typ. 1 mA)
Yes; CB scheme Yes Yes Yes; CB scheme
Yes Yes Yes Yes
cULus-Listed (UL 508, CSA C22.2
No. 107.1) File E197259; cCSAus
(CSA C22.2 No. 60950-1,
UL 60950-1)
cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259
UL-listed (UL 508) File E197259,
CSA (CSA C22.2 No. 14, CSA
C22.2 No. 107.1)
cULus-Listed (UL 508, CSA C22.2
No. 107.1) File E197259; cCSAus
(CSA C22.2 No. 60950-1,
UL 60950-1)
ATEX (EX) II 3G Ex nAC IIC T4 ATEX (available soon) ATEX (available soon) ATEX (EX) II 3G Ex nAC IIC T4
GL in preparation GL and ABS available soon GL and ABS available soon GL in preparation
IP20 IP20 IP20 IP20
EN 55022 Class B EN 55022 Class B EN 55022 Class B EN 55022 Class B
EN 61000-3-2 EN 61000-3-2 EN 61000-3-2 EN 61000-3-2
EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
0 ... +70 C with natural
convection
-25 ... +70 C with natural
convection
0 ... +70 C with natural
convection
0 ... +70 C with natural
convection
-40 ... +85 C -40 ... +85 C -40 ... +85 C -40 ... +85 C
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
One screw terminal each for
0.2 ... 4 mm
2
solid/finely stranded
One screw terminal each for
0.2 ... 4 mm single-core/finely
stranded
One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
2 screw terminals for
0.2 ... 4 mm
2
2 screw terminals for
0.2 ... 4 mm
2
2 screw terminals for
0.33 to 4 mm
2 screw terminals for
0.2 ... 4 mm
2
2 screw terminals for
0.2 ... 4 mm
2
2 screw terminals for
0.2 ... 4 mm
2
2 screw terminals for
0.33 ... 4 mm
2
2 screw terminals for
0.2 ... 4 mm
2
2 screw terminals for
0.14 ... 1.5 mm
2
2 screw terminals for
0.14 ... 1.5 mm
2
2 screw terminals for
0.14 ... 1.5 mm
2
90 145 150 70 125 125 160 125 125 90 145 150
1.6 kg 1.2 kg 2 kg 1.6 kg
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Device labeling plates
(3RT1900-1SB20)
Buffer module (6EP1961-3BA01)
Device labeling plates
(3RT1900-1SB20)
Buffer module (6EP1961-3BA01)
Signaling module
(6EP1961-3BA10)
Device labeling plates
(3RT1900-1SB20)
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 5 to 20 A
9/6
Siemens KT 10.1 2012
9
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP modular
120-230/230-500 V
2 AC
24 V DC 5 A 6EP1 333-3BA00
Special design, PSU300P
400-480 V
3 AC
24 V DC 8 A 6EP1 433-2CA00
Special design,
SIMATIC ET 200pro PS
400-480 V
3 AC
24 V DC 8 A 6ES7 148-4PC00-0HA0
SITOP modular
120-230/230-500 V
2 AC
24 V DC 10 A 6EP1 334-3BA00
SITOP smart, PSU300S
400-500 V
3 AC
24 V DC 10 A 6EP1 434-2BA10
SITOP modular, PSU300M
400-500 V
3 AC
24 V DC 20 A 6EP1 436-3BA10
Version with circuit board varnished for protection 6EP1 436-3BA00-8AA0
SITOP modular
400-500 V
3 AC
24 V DC 20 A 6EP1 436-3BA00
SITOP smart, PSU300S
400-500 V
3 AC
24 V DC 20 A 6EP1 436-2BA10
NEW
NEW
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
10
10/2 SITOP PSU300B 30 A
10/2 SITOP PSU300M 40 A
10/3 SITOP modular 40 A
10/3 SITOP PSU300S 40 A
10/6 Ordering data and additional information
SITOP 3-phase
24 V DC, 30 to 40 A
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 30 to 40 A
10/2
Siemens KT 10.1 2012
10
Overview
Technical data
1)
SIPLUS module see page 15/4.
Product Special design
PSU300B
SITOP modular
PSU300M
Power supply, type 30 A 40 A
Order No. 6EP1 437-3BA20 6EP1 437-3BA10
1)
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
Power supply optimized for battery charging, with
3-phase wide-range input for use around the world;
small frame size; with switchable output
characteristic; functional expansion possible if
expansion modules are used.
Modular power supply with
3-phase wide-range input for
use around the world; small frame size; with 50 %
extra power for 5 s/min and switchable output
characteristic; functional expansion possible if
expansion modules are used.
Expansion possibilities Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12).
Product Special design
PSU300B
SITOP modular
PSU300M
Input
3-phase AC 3-phase AC
Rated voltage value V
in rated
400 to 500 V 3 AC
wide-range input
400 to 500 V 3 AC
wide-range input
Voltage range 320 ... 575 V 320 ... 575 V
Overvoltage strength
Mains buffering at I
out rated
> 20 ms at V
in
= 400 V > 15 ms at V
in
= 400 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
1.6-1.3 A 2.6-2.1 A
Switch-on current limit (+25 C) < 56 A < 56 A
I
2
t < 2.24 A
2
s < 2.24 A
2
s
Built-in incoming fuse None None
Required protection in the supply
feeder
3-pole connected miniature circuit breaker 10 ... 16 A,
characteristic C or circuit breaker 3RV2011-1DA10
(set to 3 A) or 3RV2711-1DD10 (UL 489)
3-pole connected miniature circuit breaker 10 ... 16 A,
characteristic C or circuit breaker 3RV2011-1DA10
(set to 3 A) or 3RV2711-1DD10 (UL 489)
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
24 V DC 24 V DC
Total tolerance 3 % 3 %
Static line compensation < 0.1 % < 0.1 %
Static load compensation < 0.1 % < 0.1 %
Residual ripple < 100 mV
pp
< 100 mV
pp
Spikes (bandwidth: 20 MHz) < 200 mV
pp
< 200 mV
pp
Adjustment range 24 ... 28.8 V 24 ... 28.8 V (max. 960 W)
Status display Green LED for 24 V OK Green LED for 24 V OK
Signaling Relay contact (NO contact, contact rating
DC 60 V/0.3 A) for 24 V OK
Relay contact (NO contact, contact rating
DC 60 V/0.3 A) for 24 V OK
On/off behavior No overshoot of V
out
(soft start) No overshoot of V
out
(soft start)
Startup delay/voltage rise < 2.5 s/< 500 ms < 2.5 s/< 500 ms
Rated current value I
out rated
30 A 40 A
Current range
Up to +60 C 0 ... 30 A 0 ... 40 A
Derating 25 A (up to +70 C) 25 A (up to +70 C)
Dynamic overcurrent on
Power-up on short-circuit Approx. 32 A constant current Approx. 44 A constant current
Short circuit during operation Approx. 32 A constant current Typ. 120 A for 25 ms
Parallel switching for
enhanced performance
Yes, 2 units
(switchable characteristic)
Yes, 2 units
(switchable characteristic)
NEW
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 30 to 40 A
10/3
Siemens KT 10.1 2012
10
1)
SIPLUS module see page 15/4.
2)
SITOP modular plus 6EP1 437-3BA00-8AA0 with circuit board varnished
for protection
SITOP modular SITOP smart
PSU300S
40 A 40 A
6EP1 437-3BA00
1)2)
6EP1 437-2BA20
Modular power supply with 3-phase wide-range input
for use around the world; small frame size; with
switchable output characteristic; functional expansion
possible if expansion modules are used.
Powerful standard power supply with
3-phase wide-range input for use around the world;
high overload capability with 50 % extra power for 5
s/min and 1.2 times the rated current continuously up
to +45 C ambient temperature.
Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds
(chapter 11) and DC UPS for additional protection against mains failures (chapter 12).
SITOP modular SITOP smart
PSU300S
3-phase AC 3-phase AC
400-500 V 3 AC
Wide-range input
400-500 V AC
Wide-range input
320 ... 550 V (startup from V
in
> 340 V) 340 ... 550 V
2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
> 6 ms at V
in
= 400 V > 6 ms at V
in
= 400 V
50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
2.2 A (V
in
= 400 V) 1.7-1.5 A
< 70 A < 60 A
< 2.8 A
2
s < 3.4 A
2
s
None None
3-pole connected miniature circuit breaker 10 ... 16 A,
characteristic C or circuit breaker 3RV2011-1DA10
(set to 3 A) or 3RV2711-1DD10 (UL 489)
3-pole connected miniature circuit breaker 10 ... 16 A,
characteristic C or circuit breaker 3RV2011-1DA10
(set to 3 A) or 3RV2711-1DD10 (UL 489)
Controlled, isolated DC voltage Controlled, isolated DC voltage
24 V DC 24 V DC
3 % 3 %
Approx. 0.1 % Approx. 1 %
Approx. 0.2 % Approx. 2 %
< 100 mV
pp
< 150 mV
pp
< 200 mV
pp
< 240 mV
pp
24 ... 28.8 V (max. 960 W) 24 ... 28.0 V (max. 960 W)
Green LED for 24 V OK Green LED for 24 V OK
Use signaling module
(6EP1961-3BA10)
Relay contact (NO contact,
contact rating DC 60 V/0.3 A) for 24 V OK
No overshoot of V
out
(soft start) No overshoot of V
out
(soft start)
< 2.5 s/< 500 ms < 1.5 s/typ. 15 ms
40 A 40 A
0 ... 40 A 0 ... 40 A
> 60 C 48 A (up to +45 C)/30 A (up to +70 C)
Approx. 46 A constant current Approx. 65 A for 120 ms
Typ. 120 A for 25 ms Approx. 65 A for 120 ms
Yes, 2 units
(switchable characteristic)
Yes, 2 units
NEW
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 30 to 40 A
10/4
Siemens KT 10.1 2012
10
Technical specifications (continued)
Product Special design
PSU300B
SITOP modular
PSU300M
Power supply, type 30 A 40 A
Order No. 6EP1 437-3BA20 6EP1 437-3BA10
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 93 % Approx. 92 %
Power loss at V
out rated
, I
out rated
Approx. 50 W Approx. 83 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
<1 % V
out
<1 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. 3 % V
out
Typ. 3 % V
out
Load-step settling time
50 to 100 % < 10 ms < 10 ms
100 to 50 % < 10 ms < 10 ms
Protection and monitoring
Output overvoltage protection < 35 V < 35 V
Current limitation Typically 32 A Typ. 44 A, overload capability
150 % I
out

rated
up to 5 s/min
Short-circuit protection Alternatively, constant current characteristic approx.
32 A or latching shutdown
Alternatively, constant current characteristic approx.
44 A or latching shutdown
Sustained short-circuit current rms
value
Approx. 32 A Approx. 44 A
Overload/short-circuit indicator LED yellow for "overload", LED red for "latching cutoff" LED yellow for "overload", LED red for "latching cutoff"
Safety
Primary/secondary isolation Yes, SELV output voltage V
out
according to
EN 60950-1 and EN 50178
Yes, SELV output voltage V
out
according to
EN 60950-1 and EN 50178
Protection class Class I Class I
Leakage current < 3.5 mA < 3.5 mA
Safety test Yes Yes
CE mark Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1)
File E197259
cULus-Listed (UL 508, CSA C22.2 No. 107.1)
File E197259
Explosion protection ATEX (available soon)
Marine approval GL and ABS available soon
Degree of protection (EN 60529) IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B
Supply harmonics limitation EN 61000-3-2 EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range -25 ... +70 C with natural convection -25 ... +70 C with natural convection
Transport/storage temperature
range
-40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to EN 60721,
no condensation
Climate class 3K3 according to EN 60721,
no condensation
Mechanics
Connections
Supply input L1, L2. L3, PE One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
Output + 2 screw terminals for
0.33 ... 10 mm
2
2 screw terminals for
0.33 ... 10 mm
2
Output 2 screw terminals for
0.33 ... 10 mm
2
2 screw terminals for
0.33 ... 10 mm
2
Alarm signal 2 screw terminals for
0.14 ... 1.5 mm
2
2 screw terminals for
0.14 ... 1.5 mm
2
Dimensions (W x H x D) in mm 150 125 150 150 125 150
Weight, approx. 3.4 kg 3.4 kg
Installation Snaps onto DIN rail EN 60715 35x15 Snaps onto DIN rail EN 60715 35x15
Accessories
Buffer module (6EP1961-3BA01)
Device labeling plates (3RT1900-1SB20)
Buffer module (6EP1961-3BA01)
Device labeling plates (3RT1900-1SB20)
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 30 to 40 A
10/5
Siemens KT 10.1 2012
10
SITOP modular SITOP smart
PSU300S
40 A 40 A
6EP1 437-3BA00 6EP1437-2BA20
Approx. 90 % Approx. 91.5 %
Approx. 106 W Approx. 89 W
<1 % V
out
<3 % V
out
Typ. 2 % V
out
Typ. 1.5 % V
out
< 10 ms (typ. 4 ms) < 10 ms (typ. 1 ms)
< 10 ms (typ. 4 ms) < 10 ms (typ. 1 ms
< 35 V Yes, according to EN 60950
Typically 46 A Typ. 50 A, overload capability 150%
I
out

rated
up to 5 s/min
Alternatively, constant current characteristic approx.
46 A or latching shutdown
Electronic shutdown, automatic restart
Approx. 46 A Approx. 14 A
LED yellow for "overload", LED red for "latching cutoff"
Yes, SELV output voltage V
out
according to
EN 60950-1 and EN 50178
Yes, SELV output voltage V
out
according to
EN 60950-1 and EN 50178
Class I Class I
< 3.5 mA < 3.5 mA mA (typ. 1 mA)
Yes Yes
Yes Yes; CB scheme
UL-listed (UL 508) File E197259, CSA (CSA C22.2
No. 14, CSA C22.2 No. 107.1)
cULus-Listed (UL 508, CSA C22.2 No. 107.1)
ATEX (EX) II 3G Ex nA nC IIC T3
GL in preparation
IP20 IP20
EN 55022 Class B EN 55022 Class B
EN 61000-3-2 EN 61000-3-2
EN 61000-6-2 EN 61000-6-2
0 ... +70 C with natural convection 0 ... +70 C with natural convection
-40 ... +85 C -40 ... +85 C
Climate class 3K3 according to EN 60721,
no condensation
Climate class 3K3 according to EN 60721,
no condensation
One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
2 screw terminals for
0.33 ... 10 mm
2
2 screw terminals for
0.5 ... 10 mm
2
2 screw terminals for
0.33 ... 10 mm
2
2 screw terminals for
0.5 ... 10 mm
2
2 screw terminals for
0.14 ... 1.5 mm
2
240 125 125 150 145 150
3.2 kg 3.7 kg
Snaps onto DIN rail EN 60715 3515 Snaps onto DIN rail EN 60715 3515
Buffer module (6EP1961-3BA01)
Signaling module (6EP1961-3BA10)

KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
SITOP 3-phase
24 V DC
Output current 30 to 40 A
10/6
Siemens KT 10.1 2012
10
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
Special design, PSU300B
(Planned delivery date:
December 2011)
400-500 V
3 AC
24 V DC 30 A 6EP1 437-3BA20
SITOP modular, PSU300M
400-500 V
3 AC
24 V DC 40 A 6EP1 437-3BA10
SITOP modular
400-500 V
3 AC
24 V DC 40 A 6EP1 437-3BA00
Version with circuit board varnished for protection 6EP1 437-3BA00-8AA0
SITOP smart, PSU300S
400-500 V
3 AC
24 V DC 40 A 6EP1437-2BA20
NEW
NEW
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
11
11/2 Signaling module
11/2 Redundancy module SITOP PSE202U
11/2 Buffer module
11/4 Selectivity module
SITOP PSE200U 4 x 3 A
11/4 Selectivity module
SITOP PSE200U 4 x 10 A
11/4 Diagnostics module
SITOP select 4 x 10 A
11/7 Inrush current limiter
11/9 Ordering data and additional information
SITOP expansion modules
24 V DC
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
24 V DC
Signaling module, redundancy module,
buffer module
11/2
Siemens KT 10.1 2012
11
Overview
Technical specifications
1)
SIPLUS module see page 15/4.
Product SITOP modular signaling
module
PSE202U redundancy module SITOP modular buffer module
Type 20 A 40 A
Order No. 6EP1 961-3BA10
1)
6EP1 961-3BA21
1)
6EP1 961-3BA01
1)

The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
The signaling module, in
combination with a SITOP modular
(6EP1 .3.-3BA00) regulated power
supply, can furnish annunciation
signals describing the operational
status of the power supply. It can
also switch the power supply on
and off by remote operation. It
hooks up to the power supply
automatically.
The SITOP PSE202U redundancy
module is used to decouple two
SITOP regulated power supplies in
parallel operation. The 24 V supply
is reliably maintained when one
power supply fails.
With short-term power failures, the
load current can be backed up
without interruption via the buffer
module in combination with a
SITOP modular regulated power
supply. The buffer module is
connected in parallel to the output
of the power supply.
Product SITOP modular signaling
module
PSE202U redundancy module SITOP modular buffer module
Type 20 A 40 A
Order No. 6EP1 961-3BA10
1)
6EP1 961-3BA21 6EP1 961-3BA01
Input
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
Rated voltage value V
in rated
24 V DC 24 V DC
Voltage range 24 ... 28.8 V 24 ... 28.8 V
Control input Non-isolated input for remote
ON/OFF switching of the power
supply

Power I
in
/ 1st connection 20 A
Power I
in
/ 2nd connection 20 A
Output
Rated voltage V
out rated
V
in
approx. 0.5 V V
in
approx. 1 V
Rated current value I
out rated
Max. 40 A 40 A
Mains buffering Backup time:
At 40 A load current: 200 ms
At 20 A load current: 400 ms
At 10 A load current: 800 ms
At 5 A load current: 1.6 s
In combination with
6EP1 437-3BA10 the buffer time is
reduced by 100 ms.
Buffering time, max. 10 s
Protection and monitoring
Current limiting, static No Typically 40 A
Short-circuit protection No Electronically
Signaling/alarm signals
Status display Green LED for both input
voltages > switching threshold
Red LED for at least one input
voltage < switching threshold
Green LED for Supply voltage >
20.5 V
Signaling Isolated relay contacts
(changeover contacts, contact
rating 6 A/240 V AC) for "Output
voltage OK" and "Power supply
availability OK"
solated relay contacts
(changeover contacts, contact
rating 8 A/240 V AC, 24 V DC):
signals OK if both input voltages >
switching threshold (adjustable)

KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
Expansion modules
24 V DC
Signaling module, redundancy module,
buffer module
11/3
Siemens KT 10.1 2012
11
Technical specifications (continued).
Product SITOP modular signaling
module
PSE202U redundancy module SITOP modular buffer module
Type 20 A 40 A
Order No. 6EP1 961-3BA10
1)
6EP1 961-3BA21 6EP1 961-3BA01
Safety
Galvanic isolation Yes, safety extra low voltage acc.
to EN 60950-1 (relay contacts)
Yes, safety extra low voltage acc.
to EN 60950-1 (relay contact)
Yes, SELV acc. to EN 60950-1
Protection class Class I Class II Class I
Safety test Yes Yes Yes
CE mark Yes Yes Yes
UL/cUL (CSA) approval UL-listed (UL 508) File E197259,
CSA (CSA C22.2 No. 14, CSA
C22.2 No. 107.1)
cULus-listed (UL 508,
CSA C22.2 No. 107.1),
File E197259
UL-listed (UL 508) File E197259,
CSA (CSA C22.2 No. 14, CSA
C22.2 No. 107.1)
Explosion protection ATEX (EX) II 3G Ex nAC IIC T4
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Groups ABCD

Degree of protection (EN 60529) IP20 IP20 IP20


EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range 0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
Transport/storage temperature
range
-40 ... +85 C -40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections Screw terminals for
0.14 ... 2.5 mm
2
single-core/finely stranded
Input, output, and ground:
one screw terminal each, with
0.33 ... 10 mm
2.
solid/finely
stranded;
Relay contact: 1 screw terminal
each for 0.5 ... 2.5 mm
2.

single-core/finely stranded
One screw terminal each for
+ and for 0.5 ... 10 mm
2
single-core/finely stranded
Dimensions (W H D) in mm 26 125 116 70 125 125 70 125 125
Weight, approx. 0.15 kg 0.5 kg 1.2 kg
Installation Can be snapped directly on the
side of the basic unit
(6EP1 .3.-3BA00)
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
24 V DC
PSE200U selectivity module,
SITOP select diagnostics module
11/4
Siemens KT 10.1 2012
11
Overview
Technical specifications
1)
SITOP select is not designed for operation with DC UPS module 40 A (6EP1 931-2FC21/-2FC42).
Product PSE200U selectivity module SITOP select
diagnostics module
Type 4 x 3 A 4 x 10 A 4 x 10 A
Order No. 6EP1 961-2BA11 6EP1 961-2BA21 6EP1 961-2BA00
The selectivity module is used in
conjunction with 24 V power
supplies to distribute the load
current over several current
circuits and to monitor the
individual currents. Faults in
individual circuits caused by
overload or short-circuit are
detected and selectively switched
off so that further load current
paths remain unaffected by the
fault. This achieves fast fault
diagnostics and minimizes
standstill times.
The selectivity module is used in
conjunction with 24 V power
supplies to distribute the load
current over several current
circuits and to monitor the
individual currents. Faults in
individual circuits caused by
overload or short-circuit are
detected and selectively switched
off so that further load current
paths remain unaffected by the
fault. This achieves fast fault
diagnostics and minimizes
standstill times.
The diagnostics module is used in
conjunction with 24 V power
supplies to distribute the load
current over several current
circuits and to monitor the
individual currents. Faults in
individual circuits caused by
overload or short-circuit are
detected and selectively switched
off so that further load current
paths remain unaffected by the
fault. This achieves fast fault
diagnostics and minimizes
standstill times.
Product PSE200U selectivity module SITOP select diagnostics
module
Type 4 x 3 A 4 x 10 A 4 x 10 A
Order No. 6EP1 961-2BA11 6EP1 961-2BA21 6EP1 961-2BA00
Input
Controlled DC voltage Controlled DC voltage Controlled DC voltage
1)
Rated voltage value V
in rated
24 V DC 24 V DC 24 V DC
Voltage range 22 ... 30 V 22 ... 30 V 22 ... 30 V
Overvoltage resistance 35 V 35 V 35 V; 100 ms
Rated current I
in rated
12 A 40 A 40 A
Output
Controlled DC voltage Controlled DC voltage Controlled DC voltage
Rated voltage V
out rated
V
in
approx. 0.2 V V
in
approx. 0.2 V V
in
approx. 0.3 V
Total tolerance In accordance with the supplying
input voltage
In accordance with the supplying
input voltage
In accordance with the supplying
input voltage
Number of output channels 4 4 4
Rated current value I
out rated
3 A per channel 10 A per channel 10 A per channel
Adjustment range 0.5 ... 3 A per channel via
potentiometer
3 ... 10 A per channel via
potentiometer
2 ... 10 A per channel via
potentiometer
Parallel switching of several
channels
Not permitted Not permitted Not permitted
Channel connection Simultaneous connection of all
channels after power up of the
supply voltage > 20 V,
delay time of 25 ms, 100 ms or
adjustable "load optimized" via
DIP switch for sequential
connection
Simultaneous connection of all
channels after power up of the
supply voltage > 20 V,
delay time of 25 ms, 100 ms or
adjustable "load optimized" via
DIP switch for sequential
connection
Simultaneous connection of all
channels after power up of the
supply voltage,
delay time of 24 ms or 100 ms
programmable for sequential
connection
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 97 % Approx. 97 % (typ. 99 %) Approx. 97 %
Power loss at V
out rated
, I
out rated
Approx. 9 W Approx. 30 W (typ. 10 W) Approx. 30 W
Switch-off characteristic per
channel
Overcurrent switch-off I
out
= 1.0 ... 1.3 set value, switch-
off after approx. 5 s
I
out
= 1.0 ... 1.3 set value, switch-
off after approx. 5 s
I
out
= 1.0 ... 1.3 set value, switch-
off after approx. 5 s
Current limitation I
a
= 1.3 set value, switch-off
not before typ. 100 ms
I
a
= 1.3 set value, switch-off
not before typ. 100 ms
I
out
= 1.35 set value, switch-off
after approx. 50 ...100 ms
Immediate switch-off I
out
> set value and V
in
< 20 V,
switch-off after approx. 0.5 ms
I
out
> set value and V
in
< 20 V,
switch-off after approx. 0.5 ms
I
out
> set value and V
in
< 20 V,
switch-off after approx. 0.5 ms
Residual current at switch-off Typ. 20 mA
Reset Using keys for each channel Using keys for each channel Using keys on the module
Remote reset Non-isolated 24 V input (signal
level "high" at >15 V)
Non-isolated 24 V input (signal
level "high" at >15 V)

KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
Expansion modules
24 V DC
PSE200U selectivity module,
SITOP select diagnostics module
11/5
Siemens KT 10.1 2012
11
Technical specifications (continued).
Product PSE200U selectivity module SITOP select diagnostics
module
Type 4 x 3 A 4 x 10 A 4 x 10 A
Order No. 6EP1 961-2BA11 6EP1 961-2BA21 6EP1 961-2BA00
Protection and monitoring
Device/line protection Internal fuse 5 A per channel (not
accessible)
Internal fuse 15 A per channel (not
accessible)
FKS blade-type fuse per channel
(equipped with 15 A fuse in as-
delivered state)
Status displays Three-color LED per channel:
Green LED for "Output
switched through"
Yellow LED for "Output turned off
manually"
Red LED for "Output turned off
because of overcurrent"
Three-color LED per channel:
Green LED for "Output
switched through"
Yellow LED for "Output turned off
manually"
Red LED for "Output turned off
because of overcurrent"
Two-color LED per channel:
Green LED for "Output
switched through"
Red LED for "Output turned off
because of overcurrent"
Signaling Common signal contact
(changeover contact,
rating 0.1 A/24 V DC)
Common signal contact
(changeover contact,
rating 0.1 A/24 V DC)
Common signal contact
(NO contact, rating 0.5 A/24 V DC)
Safety
In accordance with EN 60950-1
and EN 50178
In accordance with EN 60950-1
and EN 50178
In accordance with EN 60950-1
and EN 50178
Protection class Class III Class III Class III
Degree of protection (EN 60529) IP20 IP20 IP20
CE mark Yes Yes Yes
UL/cUL (CSA) approval UL-recognized (UL 2367) File
E328600; cURus (UL 508,
CSA22.2 No. 107.1), File E197259
UL-recognized (UL 2367) File
E328600; cURus (UL 508,
CSA22.2 No. 107.1), File E197259
UL-Recognized (UL 2367)
File E328600; cURus (UL 508,
CSA C22.2 No. 107.1) File
E197259; cURus (UL 60950, CSA
C22.2 No. 60950), File E151273
Explosion protection ATEX (EX) II 3G Ex nAC II T4;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Gr ABCD T4
ATEX (EX) II 3G Ex nAC II T4;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Gr ABCD T4
ATEX (EX) II 3G Ex nAC IIC T4 U;
cCSAus (CSA C22.2 No. 60079,
UL 60079), Class I, Div. 2.
Gr ABCD T4
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Permitted ambient temperature 0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
0 ... +60 C with natural
convection
Transport/storage temperature
range
-40 ... +85 C -40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Input +24 V 2 screw terminals
for 0.5 ... 10 mm
2
2 screw terminals
for 0.5 ... 10 mm
2
2 screw terminals
for 0.33 ... 10 mm
2
Input 0 V 2 screw terminals
for 0.5 ... 4 mm
2
2 screw terminals
for 0.5 ... 4 mm
2
2 screw terminals
for 0.22 ... 4 mm
2
Output 1 ... 4 1 screw terminal each
for 0.5 ... 4 mm
2
1 screw terminal each
for 0.5 ... 4 mm
2
1 screw terminal each
for 0.22 ... 4 mm
2
Signaling contact 3 screw terminals
for 0.5 ... 4 mm
2
3 screw terminals
for 0.5 ... 4 mm
2
2 screw terminals
for 0.22 ... 4 mm
2
Remote reset 1 screw terminal
for 0.5 ... 4 mm
2
1 screw terminal
for 0.5 ... 4 mm
2

Dimensions (W H D) in mm 72 80 72 72 80 72 72 90 90
Weight, approx. 0.2 kg 0.2 kg 0.4 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
24 V DC
PSE200U selectivity module,
SITOP select diagnostics module
11/6
Siemens KT 10.1 2012
11
Characteristics
Switch-off characteristic
Circuit diagrams

Switching principle SITOP select
Switching principle SITOP PSE200U
0 20 40 60 80 100 120 140 %
Load current
R
e
l
e
a
s
e

t
i
m
e
100.0
10.0
1.0
0.1
0.0
5.0 s
0.10 s
rated
G
_
K
T
0
1
_
E
N
_
0
0
0
6
2
s
-
Reset
24V
G
_
K
T
0
1
_
E
N
_
0
0
0
6
3
a
Power supply
Control Logics
Floating
signaling
contact
Load 1 Load 2 Load 3 Load 4
SITOP select
+ 24V
Power supply, e.g. SITOP
SITOP PSE200 U
Remote
reset
(24 V DC)
Floating
signaling
contact
Control
Logics
Load
1
Load
2
Load
3
Load
4
G_KT01_EN_00378
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
100 - 480 V AC
SITOP inrush current limiter
11/7
Siemens KT 10.1 2012
11
Overview
Technical specifications
Product SITOP inrush current limiter
Order No. 6EP1 967-2AA00
The SITOP inrush current limiter module is used to reliably reduce the
starting currents that are caused, for example, by capacitors or with
pulse-controlled power supplies by the rectifier circuit on the input side
with capacitor charging
In 1-phase AC networks, it is supplied with rated voltages of 100 V,
120 V or 230 V and in 2-phase and 3-phase AC networks with 208 V to
480 V on the line side upstream of capacitors and power supplies and it
limits the inrush current temperature-independently up to e. g. < 10 A at
230 V. In static operation the limit resistance is bypassed after approx.
120 ms and the resulting power loss is reduced.
Product SITOP inrush current limiter
Order No. 6EP1 967-2AA00
Input
AC voltage 1-phase, 2-phase,
50/60 Hz
Rated voltage value V
in rated
100 ... 480 V AC
Voltage range 85 ... 575 V
Overvoltage resistance
Input current I
in rated

Output
Rated voltage V
out rated
In accordance with
the supply voltage
Rated current value I
out rated
Max. 10 A
Mains buffering
Buffering time, max.
Parallel switching for
enhanced performance
No
Protection and monitoring
Current limiting, static
Short-circuit protection Must be ensured with an upstream
protective device
Signaling/alarm signals
Status display Green LED
Alarm signals
Product SITOP inrush current limiter
Order No. 6EP1 967-2AA00
Safety
In accordance with EN 60950-1
and EN 50178
Galvanic isolation No
Protection class Class II
CE mark Yes
UL/cUL (CSA) approval Yes, cULus-listed (UL 508, CSA
C22.2 No. 107.1), File E197259
Degree of protection (EN 60529) IP20
EMC
Emitted interference EN 61000-6-3
Noise immunity EN 61000-6-2
Operating data
Permitted ambient temperature 0 ... +60 C with natural
convection
Transport/storage temperature
range
-40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections Input and output (L1, N):
One screw terminal each for
0.2 ... 2.5 mm
2
single-core/finely
stranded;
Dimensions (W H D) in mm 22.5 80 91
Weight, approx. 0.12 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
100 - 480 V AC
SITOP inrush current limiter
11/8
Siemens KT 10.1 2012
11
Circuit diagrams

SITOP inrush current limiter connection diagram
1 Phase 2 Phases 3 Phases* 3 Phases without
G
_
K
T
0
1
_
E
N
_
0
0
3
5
0
* Note: For 3-phase applications N shall only be wired on the input side for internal power supply. N must not be wired on the output side.


PE L1.1 N PE L1.1 L2.1 PE L1.1 L2.1 L3.1 PE L1.1 L2.1 L3.1
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
L N
L N
Input
Output
N
PE PE PE N N L3 L2 L2 L1 L1 L1 L3 L2 L1 PE
KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules
24 V DC / 100 - 480 V AC

11/9
Siemens KT 10.1 2012
11
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP modular signaling module
6EP1 961-3BA10
PSE202U redundancy module
24 V DC V
in
approx. 0.5 V 20 A 6EP1 961-3BA21
SITOP modular buffer module
24 V DC V
in
approx. 1 V 40 A 6EP1 961-3BA01
SITOP PSE200U selectivity module
24 V DC V
in
approx. 0.2 V 4 x 3 A 6EP1 961-2BA11
4 x 10 A 6EP1 961-2BA21
SITOP select diagnostics module
24 V DC V
in
approx. 0.3 V 4 x 10 A 6EP1 961-2BA00
SITOP inrush current limiter
100-480 V AC 100-480 V AC 10 A 6EP1 967-2AA00
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Expansion modules

Notes
11/10
Siemens KT 10.1 2012
11

KT10_EN_gesamt.book Seite 10 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
Siemens KT 10.1 2012
12
12/2 Overview
12/4 DC UPS software
12/5 DC UPS with capacitors
12/5 Overview
12/6 SITOP UPS500S 15 A
12/6 SITOP UPS500P 7 A
12/9 SITOP UPS501S
12/10 DC UPS with battery modules
12/10 Overview
12/14 DC UPS module 6 A
12/14 DC UPS module 15 A
12/14 DC UPS module 40 A
12/18 Battery module 1.2 Ah
12/18 Battery module 2.5 Ah
12/18 Battery module 3.2 Ah
12/19 Battery module 7 Ah
12/19 Battery module 12 Ah
12/22 Ordering data and additional
information
SITOP Uninterruptible power
supplies UPS 24 V DC
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Overview
12/2
Siemens KT 10.1 2012
12
Overview
The uninterruptible power supply DC with battery modules con-
sists of DC UPS modules with 6 A, 15 A, or 40 A output current
and the battery modules 1.2 Ah, 3.2 Ah, 7 Ah and 12 Ah (con-
tains lead-acid batteries with corrosion-resistant lead-calcium
high-performance grid plates and fiber-glass mat) and 2.5 Ah
(contains high-purity lead-acid "high-temperature batteries").
The maintenance-free SITOP UPS500 with capacitors as energy
storage units is especially well suited for use at high ambient
temperatures. Another advantage of these high-capacity dou-
ble-layer capacitors is the shorter charge times.
For flexible use, there is the SITOP UPS500S - 15 A basic unit in
2.5 kW and 5 kW versions. A maximum of 3 SITOP UPS501S
expansion modules with 5 kW can be connected in parallel to
increase the buffer times. The IP65 version SITOP UPS500P
disposes of capacitors for 5 or 10 kW and provides up to 7 A of
output current.
High load current up to 40 A
No ventilation is required since no gas is
emitted
For distributed applications without
control cabinet
Supports the power supply unit when there
is a temporarily increased power demand
High ambient temperatures up to 60 C
Absolutely maintenance-free
Low-cost protection against power
failures for max. 10 seconds
The 24 V power supply is maintained for
a long time, e.g. in order to continue
processes.
Backup of data and closing of applica-
tions within minutes.
Selection criteria:
Expansion module with electrolyte
capacitors for bridging temporary power
failures. Can be combined with SITOP
modular. See also under Buffer module,
chapter 11.
DC UPS module with maintenance-free lead
batteries for energy storage. Bridging of
power failures even for hours.
DC UPS with high-capacity double-layer
capacitors. Bridging of power failures for
several minutes.
Buffer module
Selection criteria:
SITOP UPS500
High load current up to 40 A
Selection criteria:
SITOP DC UPS module
G_KT01_EN_00375
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Overview
12/3
Siemens KT 10.1 2012
12
Overview (continued)
G
_
K
T
0
1
_
E
N
_
0
0
3
5
7
SITOP power supply
24 V DC 24 V DC
DC UPS module with battery module
Messages
- Mains or buffer operation
- Buffer ready or alarm
- Charging status >85 % or <85 %
via USB interface or floating relay contacts
USB interface for data exchange with
industrial PC
SITOP UPS500S basic unit 15 A
maintanance-free with capacitor, optionally with
expansion module as additional energy storage
Load
AC or 3 AC
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS software
12/4
Siemens KT 10.1 2012
12
Overview
The uninterruptible DC power supplies are optionally available
with USB interface or serial interface. All relevant messages
about the status of the uninterruptible DC power supply can be
transferred to a PC (e.g. SIMATIC IPC) via this interface.
SITOP DC UPS software provides the user with a very easy to
use software tool with which the signals sent by the
uninterruptible DC power supply can be further processed on
the PC. In monitoring mode, the statuses of the uninterruptible
DC power supply are visualized on the PC.
Safe shutdown in the event of a power failure and automatic PC
restart are supported. It is also possible to freely define
responses to the different operating states of the uninterruptible
DC power supply, so that extremely flexible integration into a
wide variety of applications is possible.
The software runs under the operating systems, Windows 2000,
Windows XP, Windows Vista and Windows 7. It is available as
freeware on the SITOP homepage and can be downloaded free
of charge.
https://www.siemens.com/sitop-ups Monitoring and configuration window of software V3 for SITOP DC UPS
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with capacitors
Overview
12/5
Siemens KT 10.1 2012
12
Overview
Uninterruptible power supplies normally store the electrical en-
ergy in lead-acid batteries. Temperatures such as those preva-
lent in control cabinets considerably shorten the service life of
the battery, however, and the batteries must be replaced on a
regular basis annually at an ambient temperature of 40 C, for
example. The innovative SITOP UPS500, however, is based on
absolutely maintenance-free capacitors with a long service life.
Even at temperatures of 50 C they still have more than 80 % of
their capacity after 8 years, so there is no need to replace the en-
ergy stores. Because the capacitors do not emit any gas, the
control cabinet does not have to be ventilated.
Another advantage is the significantly shorter charging times of
the double-layer capacitors, which ensure that the buffer is
ready very quickly after loss of power.
The IP65 version SITOP UPS500P has capacitors for 5 or 10 kW
and provides up to 7 A of output current. The oblong metal
enclosure is also suitable for installing on support arm systems.
Selection table SITOP UPS500 (optional with SITOP UPS501S expansion module) and mains buffering times
Important information for selecting the energy storage units:
When the mains buffering times were determined, the discharge
period of new or non-aged, completely charged capacitors was
used as a basis. At a continuous ambient temperature of +50 C,
a loss of capacity of approx. 20% must be considered after a
service life of 8 years.
Buffering and charging times
SITOP UPS500S/501S configurations UPS500P
Basic unit 2.5 kW 5 kW 2.5 kW 5 kW 2.5 kW 5 kW 2.5 kW 5 kW 5 kW 10 kW
Expansion
modules
1 5 KWs 1 5 KWs 2 5 KWs 2 5 KWs 3 5 KWs 3 5 KWs
Total energy 2.5 kW 5 kW 7.5 kW 10 kW 12.5 kW 15 kW 17.5 kW 20 kW 5 kW 10 kW
Load current Buffer times
0.5 A 134 s 236 s 390 s 478 s 632 s 748 s 851 s 1007 s 284 s 647 s
0.8 A 90 s 167 s 266 s 346 s 440 s 527 s 580 s 706 s 190 s 435 s
1 A 75 s 138 s 219 s 296 s 365 s 414 s 490 s 572 s 153 s 351 s
2 A 38 s 76 s 122 s 156 s 203 s 230 s 265 s 306 s 80 s 152 s
3 A 26 s 52 s 82 s 106 s 136 s 159 s 186 s 213 s 53 s 108 s
4 A 19 s 39 s 61 s 81 s 101 s 120 s 139 s 160 s 40 s 84 s
5 A 15 s 31 s 49 s 65 s 81 s 95 s 111 s 130 s 30 s 68 s
6 A 12 s 26 s 40 s 55 s 67 s 80 s 94 s 106 s 25 s 57 s
7 A 10 s 21 s 34 s 47 s 58 s 69 s 81 s 82 s 21 s 49 s
8 A 8 s 18 s 29 s 40 s 50 s 59 s 69 s 79 s
10 A 6 s 15 s 23 s 32 s 39 s 47 s 54 s 62 s
12 A 4 s 12 s 19 s 26 s 32 s 38 s 44 s 52 s
15 A 3 s 9 s 14 s 20 s 25 s 30 s 35 s 40 s
Charging
current
Charging times
2 A 54 s 120 s 158 s 223 s 263 s 318 s 355 s 417 s 130 s 360 s
1 A 110 s 205 s 311 s 425 s 503 s 625 s 695 s 816 s - -
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with capacitors
SITOP UPS500
12/6
Siemens KT 10.1 2012
12
Overview
Technical specifications
1)
All SITOP 24 V DC power supplies are permissible without restriction.
Product SITOP UPS500S 15 A SITOP UPS500P 7 A
Power supply, type Basic unit 15 A Basic unit 7 A, IP65
Order No. 6EP1 933-2EC41
(with USB interface and 2.5 kWs)
6EP1 933-2EC51
(with USB interface and 5 kWs)
6EP1 933-2NC01
(with USB interface and 5 kWs)
6EP1 933-2NC11
(with USB interface and 10 kWs)
Compact design, only
120 mm wide
Two versions with integrated energy storage units:
2.5 kWs or 5 kWs
Can be expanded easily using a user-friendly plug-
in system with the expansion module 5 kWs
Absolutely uninterruptible bridging of power failures,
as soon as the DC UPS input voltage falls below the
value set by the DIP switches
High level of safety and availability through
monitoring of operational readiness, and monitoring
of the capacitor charge (message "> 85 % charged")
Support for automatic warm restart of industrial PCs
through selectable shutdown characteristics
With USB interface
Compact design, degree of protection IP65
For distributed use,
e.g. on support arms
Integrated energy storage:
5 kW or 10 kW
Ambient temperature range for operation: 0 to +55
C
High degree of efficiency 96.9 % or or low power
loss, approx. 6 W with 7 A load current
USB interface
Indication of the operating states "normal operation",
"buffer mode", alarm message "Buffer not ready" and
capacitor charge > 85 %
Product SITOP UPS500S 15 A SITOP UPS500P 7 A
Input L+/M in normal operation
Controlled DC voltage Controlled DC voltage
Rated voltage V
in

rated
1)
24 V DC 24 V DC
Voltage range 22 ... 29 V 22.5 ... 29 V
Connection threshold for buffering 22.5 V DC 0.1 V (factory setting), adjustable in the
range 22 ... 25.5 V DC (in 0.5 V increments)
22.5 V DC 0.1 V
Rated current I
in rated
15.2 A + approx. 2.3 A with empty energy storage
(capacitor)
7 A + approx. 2 A with empty energy storage
(capacitor)
Mains buffering
Mains buffering or buffering times
without add-on modules
6EP1 933-2EC41: 15 A for 3 s or 10 A for 6 s
or 5 A for 15 s or 2 A for 38 s
6EP1 933-2EC51: 15 A for 9 s or 10 A for 15 s
or 5 A for 31 s or 2 A for 76 s
7 A for 49 s or 5 A for 68 s or 3 A for 108 s
or 1 A for 351 s
Mains buffering or buffering times
with expansion modules
For longer buffering times, see table not applicable
On/off control circuit External isolated NO contact required (loading max.
15 V DC/max. 10 mA). Buffering is terminated by
disconnecting the control circuit.
not applicable
Methods of setting
the buffering time
Adjustable using DIP switches to a maximum
buffering time up to forced shutdown at approx. 7 V
internal capacitor voltage (output remains constant at
24 V up to that point) or to a time limit of 5 ... 315 s (in
10 s increments) if the energy content is sufficient for
the required current
not applicable
Interruption Adjustable with DIP switch, either:
Interruption of the output voltage despite returning
input voltage for 5 s following expiry of set buffering
time to support automatic restarting of industrial PCs
Or
No forced interruption at the end of the set buffer
time
not applicable
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with capacitors
SITOP UPS500
12/7
Siemens KT 10.1 2012
12
Technical specifications (continued).
Product SITOP UPS500S 15 A SITOP UPS500P 7 A
Power supply, type Basic unit 15 A Basic unit 7 A, IP65
Order No. 6EP1 933-2EC41
(with USB interface and 2.5 kWs)
6EP1 933-2EC51
(with USB interface and 5 kWs)
6EP1 933-2NC01
(with USB interface and 5 kWs)
6EP1 933-2NC11
(with USB interface and 10 kWs)
Output L+/M in normal operation
Rated voltage V
out rated
24 V DC (controlled) 24 V DC (controlled)
Voltage range 23.3 ... 24.7 V DC or 24 V DC 3% 23.3 ... 24.7 V DC or 24 V DC 3%
Startup delay Approx. 600 ms Approx. 600 ms
Voltage rise Approx. 25 ms Approx. 25 ms
Output current I
out
0 ... 15 A 0 ... 7 A
Dynamic current with overload Electronic current limitation to typically 25 A for
approx. 200 ms, then electronic shutdown of the
output with automatic restart attempts (approx. 20 s
intervals between restart attempts).
Electronic shutdown at typ. 30 A, automatic restart
after 20 s
Dynamic current with short-circuit Electronic current limitation to typically 25 A for
approx. 110 ms, then electronic shutdown of the
output with automatic restart attempts (approx. 20 s
intervals between restart attempts).
Electronic shutdown at typ. 30 A, automatic restart
after 20 s
Output L+/M with buffer mode
Rated voltage V
out rated
24 V DC 24 V DC
Approximate voltage range 23.3 ... 24.7 V DC or 24 V DC 3% 23.3 ... 24.7 V DC or 24 V DC 3%
Output current I
out
0 ... 15 A 0 ... 7 A
Dynamic current with overload Electronic current limitation to typically 25 A for
approx. 200 ms, then electronic shutdown of the
output (restarts after normal operation is resumed).
Electronic shutdown at typ. 30 A, automatic restart
after 20 s
Dynamic current with short-circuit Electronic current limitation to typically 25 A for
approx. 110 ms, then electronic shutdown of the
output (restarts after normal operation is resumed).
Electronic shutdown at typ. 30 A, automatic restart
after 20 s
Charging current Approx. 1 A (factory setting), adjustable to 1 A or 2 A
(charging is carried out with closed and open on/off
circuit).
2 A set permanently
Charge time after a discharge 6EP1 933-2EC41:
110 s with 1 A, 54 s with 2 A
6EP1 933-2EC51:
205 s with 1 A, 120 s with 2 A
approx. 300 s
Charging time with add-on modules For longer charging times, see table not applicable
Efficiency/heat loss
At V
out rated
, I
out rated
approx. 97.5 % / 9 W 96.5 % / 5.2 W
Protection and monitoring
Reverse polarity protection against polarity reversal on input voltage against polarity reversal on input voltage
Overload protection Electronic shutdown of the output in accordance with
"dynamic current with overload" in normal operation
(automatic restart attempts) or in buffer mode (restart
following return to normal operation).
Electronic shutdown of the output in accordance with
"dynamic current with overload" in normal operation
(automatic restart attempts) or in buffer mode (restart
following return to normal operation).
With thermal overload protection
Short-circuit protection Electronic shutdown of the output in accordance with
"dynamic current with overload" in normal operation
(automatic restart attempts) or in buffer mode (restart
following return to normal operation), built-in
(unaccessible) fuse rated at 20 A.
Electronic shutdown of the output in accordance with
"dynamic current with overload" in normal operation
(automatic restart attempts) or in buffer mode (restart
following return to normal operation).
With thermal overload protection
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with capacitors
SITOP UPS500
12/8
Siemens KT 10.1 2012
12
Technical specifications (continued).
1)
85 % with regard to residual capacity still available depending on aging. The original capacity (= capacity when new) reduces by only approx. 20 % within 8
years of operation even at a high ambient temperature of the device of +50 C, for example, so that 80 % residual capacity still remains. The backup times
also reduce by approximately 20 % in 8 years (at +50 C) with small currents (up to approximately 5 A), and by approximately 30 % with high load currents
(over 10 A).
Note: The lower the ambient temperature, the smaller the capacity reduction (approximately one half per 10 C lower ambient temperature, that is at +40 C,
for example, only 10 % capacity reduction in 8 years).
2)
Permissible contact rating: 60 V DC/1 A or 30 V AC/1 A.
Product SITOP UPS500S 15 A SITOP UPS500P 7 A
Power supply, type Basic unit 15 A Basic unit 7 A, IP65
Order No. 6EP1 933-2EC41
(with USB interface and 2.5 kWs)
6EP1 933-2EC51
(with USB interface and 5 kWs)
6EP1 933-2NC01
(with USB interface and 5 kWs)
6EP1 933-2NC11
(with USB interface and 10 kWs)
Signaling
Normal operation Green LED (OK) and isolated relay contact
(changeover contact)
2)
Green LED (OK)
Buffer mode (capacitor supplies
load alone or in addition to the PS in
the case of overload)
Yellow LED (Bat) and isolated relay contact
(changeover contact)
2)
Yellow LED (Bat)
Alarm (buffer not ready, or pre-
warning from < 12 V capacitor
voltage)
Red LED (Alarm) and isolated relay contact
(changeover contact)
2)
Red LED (Alarm)
"Capacitor charged > 85 %"
1)
Second green LED (Bat > 85 %) and isolated NO
contact (rest position = open)
Second green LED (Bat > 85 %)
USB interface
Output of all alarm signals and receipt of the "Remote
Timer start" signal.
Technical design: Specification 2.0 with Full Speed,
ie. 2 Mbit/s, supplied by DC UPS with +5 V ("self
powered")
Required connection to the PC: Commercially
available 4-core shielded cable, 90 ohms, max. 5 m,
USB series "A" connector to PC and USB series "B"
connector to DC UPS
Output of all alarm signals and receipt of the "Remote
Timer start" signal.
Technical design: Specification 2.0 with Full Speed,
ie. 2 Mbit/s, supplied by DC UPS with +5 V ("self
powered")
Required connection to the PC: see connector set
Software A software tool (executable under Windows 2000,
Windows XP, Windows Vista and Windows 7) for
reading and processing the signals can be
downloaded from
https://www.siemens.com/sitop-ups
Additional information on the interface is also
available at this site.
A software tool (executable under Windows 2000,
Windows XP, Windows Vista and Windows 7) for
reading and processing the signals can be
downloaded from
https://www.siemens.com/sitop-ups
Additional information on the interface is also
available at this site.
Control signals
On/off control signal Buffering is terminated by opening the control circuit
or by means of DIP switches on the device (DIP
switch must be in "Off" position). All other functions
are retained.
not applicable
"Remote Timer start" via USB
interface
Starts mains buffering for the set buffer time Starts mains buffering for the set buffer time
Safety
Primary/secondary isolation No No
Protection class Class III (ext. circuit and power-supply unit: SELV in
accordance with EN 60950 required)
Class III (ext. circuit and power-supply unit: SELV in
accordance with EN 60950 required)
EMC
Emitted interference Radio interference suppression according to
EN 55022. Limit-value curve B
Radio interference suppression according to
EN 55022. Limit-value curve B
Noise immunity according to EN 61000-6-2 according to EN 61000-6-2
Ambient conditions
Ambient temperature during
operation
0 ... +60 C with natural convection 0 ... +55 C with natural convection
Transport/storage temperature -40 ... +70 C -40 ... +70 C
Degree of protection (EN 60529) IP20 IP65
Humidity class Rated conditions in accordance with EN 60721,
climate class 3K3 (relative humidity 5 % ... 85 % and
absolute humidity 1 g/m
3
... 25 g/m
3
; no
condensation)
Rated conditions in accordance with EN 60721,
climate class 3K3 (relative humidity 5 % ... 85 % and
absolute humidity 1 g/m
3
... 25 g/m
3
; no
condensation)
KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with capacitors
SITOP UPS500
12/9
Siemens KT 10.1 2012
12
Technical specifications (continued).
1)
The connector set contains connection plugs for input and output and pre-assembled USB cables, 2 m long (connector set not included in the scope of
supply SITOP UPS500P!) MLFB: 6EP1 975-2ES00.
Overview Technical specifications
Product SITOP UPS500S 15 A SITOP UPS500P 7 A
Power supply, type Basic unit 15 A Basic unit 7 A, IP65
Order No. 6EP1 933-2EC41
(with USB interface and 2.5 kWs)
6EP1 933-2EC51
(with USB interface and 5 kWs)
6EP1 933-2NC01
(with USB interface and 5 kWs)
6EP1 933-2NC11
(with USB interface and 10 kWs)
Approvals
CE Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1)
File E197259

Mechanics
Input connections 24 V DC 2 screw terminals for 1 ... 4 mm
2
/17 ... 11 AWG See connector set
1)
Output connections 24 V DC 4 screw terminals for 1 ... 4 mm
2
/17 ... 11 AWG See connector set
1)
Connections for control circuit and
alarm signals
10 screw terminals for 0.5 ... 2.5 mm
2
/20 ... 13 AWG not applicable
USB port Yes Yes
Dimensions (W x H x D) in mm 120 125 ca. 125 400 (without connector) 80 80
470 (without connector) 80 80
Required clearances 50 mm above and 50 mm underneath unit 50 mm above and 50 mm underneath unit
Weight Approx. 1.0 kg Approx. 1.9 kg
Approx. 2.2 kg
Installation Snaps onto DIN rail EN 60715 35x7.5/15 Screw mounting
Product SITOP UPS501S
Power supply, type Expansion module
Order No. 6EP1 935-5PG01
Additional energy storage
(5 kW)
Up to 3 expansion modules can
be connected to a SITOP
UPS500S to extend the buffer
times
Complete with balancing and
safety circuits
Product SITOP UPS501S
Power supply, type Expansion module
Order No. 6EP1 935-5PG01
Mechanics
Connections Can be easily connected to SITOP
UPS500S via a user-friendly plug-
in system
Dimensions (W H D) in mm Approx. 70 125 125
Weight Approx. 0.7 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
Overview
12/10
Siemens KT 10.1 2012
12
Overview
By combining a DC UPS module with at least one 24 V battery
module and a SITOP power supply unit, longer power failures
can be bridged without any interruption.
The combination is used for example in machine-tool building, in
the textile industry, on all types of production lines and filling
plants, and in conjunction with 24 V industrial PCs. This prevents
the negative effects which often result from power failures.
DC-UPS modules: 6 A, 15 A, 40 A
Battery modules:
1.2 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium, high-capacity grid plates and fiberglass mat)
3.2 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium, high-capacity grid plates and fiberglass mat)
7 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium, high-capacity grid plates and fiberglass mat)
12 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium, high-capacity grid plates and fiberglass mat)
2.5 Ah (contains "high-temperature battery" lead-acid type)
Selection table for battery modules and mains buffering times
Important information for selecting the battery capacity:
The mains buffering times are based on the discharge period
of new or non-aged, fully charged battery modules at a battery
temperature of not less than +25 C down to a battery voltage
of 21 V (with voltage drops in the DC UPS, approximately
20.4 V DC still remain for the load).
Battery aging reduces the still available battery capacity up to
the end of the service life to typically around 50 % of the original
capacity value when new (1.2 Ah or 3.2 Ah or 7 Ah, etc.) and
the internal resistance increases. When the message "Battery
charge > 85 %" appears, only around 50 % 85 % = approx. 43
% of the originally available capacity can be assumed at the
end of the battery service life.
At battery temperatures below +25 C, the available capacity
drops by another 30 % at +5 C battery temperature from ap-
prox. 43 % to approx. 70 %. There is then only around 30 % of
the original capacity available.
A significantly larger battery capacity must therefore be se-
lected when configuring the plant: A drop to approx. 50 % is
compensated for by selecting 1 / approx. 0.5 = approx.
double the battery capacity (required as per the table for the
relevant load current and the relevant buffering time).
Available capacity of approx. 43 % is compensated for by
selecting 1 / approx. 0.43 = approx. 2.33 times battery capacity.
Available capacity of approx. 30 % is compensated for by
selecting 1 / approx. 0.3 = approx. 3.33 times battery capacity.
Recommendation:
Instead of installing double the battery capacity to cope with
battery aging, regular battery replacement midway through
the expected service life (reduction of capacity to approx.
50 %) can be more advisable for the following reasons: Until
the halfway point of the expected battery service life (or
slightly beyond), capacity does not drop below 100 %. With
regular replacement after halfway through expected service
life, only single battery capacity (instead of double capacity)
must be installed regarding aging ( neutral in price with regard
to battery module costs but requires only half the space).
Replacing after half the service life dispenses in particular with
the large scatter range of the residual capacity at the end of
the service life, which is not accurately defined by battery
manufacturers (after the full time, many batteries are above,
but many are also below the average of 50 % residual
capacity, that is, even if double the capacity is installed, the
influence of aging at the end of service life is not reliably
compensated for, but only typically) In the case of
replacement after half the expected service life, the configured
buffering time is maintained significantly more reliably.
Load current Battery module 1.2 Ah
(6EP1935-6MC01)
Battery module 3.2 Ah
(6EP1935-6MD11)
Battery module 7 Ah
(6EP1935-6ME21)
Battery module 12 Ah
(6EP1935-6MF01)
Battery module 2.5 Ah
(6EP1935-6MD31)
1 A 30 min 2.5 h 6 h 11 h 2 h
2 A 11 min 45 min 2.5 h 5 h 45 min
3 A 4 min 25 min 1.5 h 3 h 30 min
4 A 2 min 20 min 45 min 2 h 20 min
6 A 1 min 10 min 30 min 1 h 13 min
8 A 4 min 20 min 40 min 9 min
10 A 1.5 min 15 min 30 min 7 min
12 A 1 min 10 min 25 min 5.5 min
14 A 50 s 8 min 20 min 4.5 min
16 A 40 s 6 min 15 min 4 min
20 A 2 min 11 min
KT10_EN_gesamt.book Seite 10 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
Overview
12/11
Siemens KT 10.1 2012
12
Overview (continued)
In the case of batteries stored in cool conditions (not
exceeding +25 C) and for not longer than approximately 4
months, the following service life can be assumed, strongly
dependent on battery temperature:
In normal cases (installation in the coolest location in the
control cabinet at approx. +30 C), the battery with single
installed battery capacity should be replaced in accordance
with the selection table after 1 year of operation!
On the DC UPS module 40 A, at least 2 battery modules of 7 Ah
or higher must be connected in parallel for output currents > 30
A. When connecting battery modules in parallel, you must ensure
identical capacity and aging.
After a power failure, the battery module is disconnected from the
loads at the end of the selected buffering time either
automatically or electronically by opening the On/Off control
circuit, and as soon as the 24 V input voltage is available again,
it is quickly re-charged with the charge current of the relevant DC
UPS module (with I-V charge characteristic: First constant
current I for fast charging, and changeover to constant voltage V
to maintain the charge when the battery is almost full).
Integration
Battery
temperature
Drop to
approx. 50 % of
residual
capacity
Recommenda-
tion:
Replace all (with
100 %
residual
capacity)
Alternative
recommendation
+20 C 4 years 2 years
+30 C 2 years 1 year
+40 C 1 year 0.5 years Install double
capacity and
replace
(1 per year)
1
X3.1-9
L+ X1.1
M X1.2
Input V
e
24V DC
DC
DC
X1.7 +Bat
27-
18.5V DC
X1.8 -Bat
X1.3 L+
X1.4 M
X1.6 M
output
V
a

X2.1
X2.3
X2.2
X2.4
X2.6
X2.5
X2.7
X2.8
X2.9
X2.10 M
+2V
+1V
+0,5V
+1V
+0,5V
+0,2V
+0,2V
+0,1V
+320s
+160s
+ 80s
+ 40s
+ 20s
+ 10s
Bat
24V DC o.k.
Batt. o.k. Ba<85%
optional USB
for 6EP1931-2DC42
and 6EP1931-2EC42
serial
interface
only 6EP1931-2DC31
and 6EP1931-2EC31
power
supply
battery
power stack
load
charging current *
1
set time/max. time
disconnect V
a
green yellow green red
monitoring/control
operating elements
*1: charging current 0.2 A or 0.4 A for 6EP1931-2DC../0.35 A or 0.7 A for 6EP1931-2EC..
readiness to buffer
charge <85%
operating state battery
On/Off
opperating state battery
On/Off
buffering time
cut-in threshold
SITOP
alarm
G_KT01_EN_00226
alarm
end-of-charge
voltage
+22V fixed
+26.3V fixed
DC UPS module
KT10_EN_gesamt.book Seite 11 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
Overview
12/12
Siemens KT 10.1 2012
12
Function
The following timing diagrams show examples of the characteristic of the input and output voltage at the terminals of the DC UPS
module as well as the signal characteristic of the signals (relays) and of the remote signal (port).
"Long" power failure with DC UPS without serial or USB port
(Fig. 12/1)
Power restoration only once buffer time tp has expired
(t3 follows t4):
Upon failure of the input voltage on the DC UPS module (time t1),
the battery "Bat" immediately takes over the DC supply, and the
output voltage V
out
is then retained absolutely without
interruption.
The isolated changeover contact "OK/Bat" switches over to its off
position "Bat".
At the same point in time t1, the buffer time tp set on the DIP
switches is started automatically.
The fact that the DIP switch is set to "Interruption output V
out
" in
this example has no effect because the input voltage returns at
time t3 only once the set buffer time (time t4) has expired.
"Short" power failure with DC UPS without serial or USB port
(Fig. 12/2)
Power restoration before buffer time tp has expired (t3 before t4):
Upon failure of the input voltage on the DC UPS module (time t1),
the battery "Bat" immediately takes over the DC supply, and the
output voltage V
out
is then retained absolutely without
interruption.
The isolated changeover contact "OK/Bat" switches over to its off
position "Bat".
At the same point in time t1, the buffer time tp set on the DIP
switches is started automatically.
With the DIP switch set to "Interruption output V
out
", the output
voltage V
out
is automatically interrupted for 5 s once the set buffer
time tp (time t4) has expired.
The battery has already been disconnected because the input
voltage has returned at the time t3.
If the DIP switch is not set to "Interruption output V
out
", there is no
interruption in this example because the input voltage has
already returned at time t3 prior to expiry of the set buffer time
(time t4).
Figure 12/1 "Long power failure" Figure 12/2 "Short power failure"
DC UPS without serial or USB port (6EP1931-2DC21/-2EC21/-2FC21)
DIP switch settings on device: buffer time tp (from 5 s to 635 s with bottom row nos. 2 to 7) /
/ t = according to setting (with bottom row no. 1 to left) / = with setting for interruption V
out
(with bottom row no. 8 to left)
Legend:
V
in
V
out
ok
Bat
t1 t4 t3
(t4 - t1 = tp)
G_KT01_XX_00220
V
in
V
out
ok
Bat
t1 t3 t4 t5
(t4 - t1 = tp) (t5 - t4 = 5 s)
V
in
: Input voltage at terminals X1.1 X1.2
V
out
: Output voltage at terminals X1.3 X1.4 and X1.5 - X1.6
ok: Signal for input voltage V
in
OK or above the set battery
connection threshold
Bat: Signal for battery operation (batteries connected to output,
batteries supply the load)
Remote: Signal for remote timer start with signal level = 0 at pin 7 of
9-pin serial interface (pin 7 is usually the positive power
supply for the interface)
t1: Input voltage V
in
missing or falls below the set connection
threshold
t2: Buffer time set on DIP switches is started by remote timer
start (signal level = 0)
t3: Input voltage V
in
rises above set connection threshold
t4: End of set buffer time (output is switched off and/or battery
is disconnected)
t5: Output is connected again 5 s after shutdown
tp: Buffer time set on the DIP switches (bottom row nos. 2 to 7)
KT10_EN_gesamt.book Seite 12 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
Overview
12/13
Siemens KT 10.1 2012
12
Function (continued)
"Long" power failure with DC UPS with serial or USB port
(Fig. 12/3)
Power restoration only once buffer time tp
(t3 follows t4) has expired:
Upon failure of the input voltage on the DC UPS module (time t1),
the battery "Bat" immediately takes over the DC supply, and the
output voltage V
out
is then retained absolutely without
interruption.
The isolated changeover contact "OK/Bat" switches over to its off
position "Bat".
The buffer time tp set on the DIP switches is started at the user-
selectable time t2 by means of the signal "Remote timer start"
(signal level = 0 at pin 7 of the 9-pin serial port following previous
signal chart according to operating instructions).
The fact that the DIP switch is set to "Interruption output V
out
" in
this example has no effect because the input voltage returns at
time t3 only once the set buffer time (time t4) has expired.
Note: Without a remote signal level = 0 with a setting t = max.
duration, there is no interruption to the output voltage in this case
because the set buffer time is not started (or interruption only if
the exhaustive discharge protection disconnects the
accumulator and the input voltage has not returned by then).
"Short" power failure with DC UPS with serial or USB port
(Fig. 12/4)
Power restoration before buffer time tp
(t3 before t4) has expired:
Upon failure of the input voltage on the DC UPS module (time t1),
the battery "Bat" immediately takes over the DC supply, and the
output voltage V
out
is then retained absolutely without
interruption.
The isolated changeover contact "OK/Bat" switches over to its off
position "Bat".
The buffer time tp set on the DIP switches is started at the user-
selectable time t2 by means of the signal "Remote timer start"
(signal level = 0 at pin 7 of the 9-pin serial port following previous
signal chart according to operating instructions).
With the DIP switch set to "Interruption output V
out
", the output
voltage V
out
is automatically interrupted for 5 s once the set buffer
time tp (time t4) has expired.
The battery has already been disconnected because the input
voltage has returned at the time t3.
The interruption to the output voltage V
out
for 5 s permits an
automatic restart for many industrial PCs, even if the line voltage
(or the input voltage V
in
on the DC UPS module) returns during
shutdown of the PC, as in this example.
Note: Without a remote signal level=0 with a setting t = max.
duration, there is no interruption in the output voltage here
because the set buffer time is not started.
Figure 12/3 "Long power failure" Figure 12/4 "Short power failure"
DC UPS with serial or USB port (6EP1931-2DC31/-2DC42/-2EC31/-2EC42/-2FC42)
DIP switch settings on device: buffer time tp (from 5 s to 635 s with bottom row nos. 2 to 7) /
/ t = max. time (with bottom row no. 1 to right) / interruption of V
out
(with bottom row no. 8 to left)
Legend:
V
in
V
out
ok
Bat
Remote
t1 t2 t4 t3
(t4 - t2 = tp)
G_KT01_XX_00222
V
in
V
out
ok
Bat
Remote
t1 t2 t4 t5 t3
(t4 - t2 = tp) (t5 - t4 = 5 s)
G_KT01_XX_00223
V
in
: Input voltage at terminals X1.1 X1.2
V
out
: Output voltage at terminals X1.3 X1.4 and X1.5 - X1.6
ok: Signal for input voltage V
in
OK or above the set battery
connection threshold
Bat: Signal for battery operation (batteries connected to output,
batteries supply the load)
Remote: Signal for remote timer start with signal level = 0 at pin 7 of
9-pin serial interface (pin 7 is usually the positive power
supply for the interface)
t1: Input voltage V
in
missing or falls below the set connection
threshold
t2: Buffer time set on DIP switches is started by remote timer
start (signal level = 0)
t3: Input voltage V
in
rises above set connection threshold
t4: End of set buffer time (output is switched off and/or battery
is disconnected)
t5: Output is connected again 5 s after shutdown
tp: Buffer time set on the DIP switches (bottom row nos. 2 to 7)
KT10_EN_gesamt.book Seite 13 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
DC UPS modules 6 A, 15 A, 40 A
12/14
Siemens KT 10.1 2012
12
Overview
Technical specifications
1)
SIPLUS modules see page 15/4.
2)
All SITOP 24 V DC power supplies are permissible without restriction.
3)
In order to implement more than 30 A up to max. 40 A output current for the DC-UPS module 40 A, two 7 Ah or 12 Ah battery modules connected in parallel
are required.
Product DC UPS module DC UPS module DC UPS module
Power supply, type 6 A 15 A 40 A
Order No. 6EP1 931-2DC21
6EP1 931-2DC31
(with serial interface)
6EP1 931-2DC42
(with USB interface)
6EP1 931-2EC21
1)

6EP1 931-2EC31
(with serial interface)
6EP1 931-2EC42
(with USB interface)
6EP1 931-2FC21
1)

6EP1 931-2FC42
(with USB interface)
Product DC UPS module DC UPS module DC UPS module
Power supply, type 6 A 15 A 40 A
Input L+/M in normal operation
Controlled DC voltage Controlled DC voltage Controlled DC voltage
Rated voltage value V
in rated
2)
24 V DC 24 V DC 24 V DC
Voltage range 22 ... 29 V DC 22 ... 29 V DC 22 ... 29 V DC
Connection threshold for battery 22.5 V DC 0.1 V (factory setting),
adjustable in the range 22 to
25.5 V DC
(in 0.5 V increments)
22.5 V DC 0.1 V (factory setting),
adjustable in the range 22 to
25.5 V DC
(in 0.5 V increments)
22.5 V DC 0.1 V (factory setting),
adjustable in the range 22 to
25.5 V DC
(in 0.5 V increments)
Rated current value I
in rated
6 A + approx. 0.6 A with empty
battery
15 A +approx. 1 A with empty
battery
40 A + approx. 2.6 A with empty
battery
Mains buffering
Mains buffering or
buffer time
Dependent on connected battery and load current, see selection table battery module and mains buffering
times as well as the relevant important information notes!
On/off control circuit External isolated NO contact required (max. load 15 V DC / max. 10 mA).
With an open control circuit, the battery is isolated from output L+, thus canceling mains buffering. If there is no
input voltage, a quiescent current of approximately 0.3 mA is drawn from the battery disconnected from the
output.
Methods of setting
the buffering time
Adjustable using DIP switches to a maximum buffering time up to forced shutdown due to exhaustive discharge
protection (at approx. 19 V) or to a time limit of 5 ... 635 s (in 10 s steps)
Interruption Adjustable using DIP switch, either:
Interruption in output voltage despite returning input voltage for min. 5 s following expiry of set buffer time to
support automatic restarting of industrial PCs or
No forced interruption on expiry of the set buffer time
Output L+/M in normal operation
Rated voltage V
out rated
24 V DC (output voltage of SITOP
power supply)
24 V DC (output voltage of SITOP
power supply)
24 V DC (output voltage of SITOP
power supply)
Voltage range Input voltage V
in
less approx.
0.5 V DC
Input voltage V
in
less approx.
0.5 V DC
Input voltage V
in
less approx.
0.5 V DC
Startup delay Approx. 1 s Approx. 1 s Approx. 1 s
Voltage rise Typ. 60 ms Typ. 60 ms Typ. 360 ms
Output current I
out
0 ... 6 A 0 ... 15 A 0 ... 40 A
Dynamic current with overload Electronic current limitation to 1.05 ... 1.4 I
out rated
for approx. 80 ms, then electronic shutdown of the output
with automatic restart attempts (approx. 20 s intervals between restart attempts)
Dynamic current with short-circuit Electronic current limitation to1.5... 3 I
out rated
for approx.20 ms, then electronic shutdown of the output with
automatic restart attempts (approx. 20 s intervals between restart attempts)
Output L+/M with battery operation
Rated voltage V
out rated
24 V DC (from battery module) 24 V DC (from battery module) 24 V DC (from battery module)
Approximate voltage range 27 ... 19 V DC at I
out
= 0.05 C 1/h or 24 V at I
out
= 1 C 1/h or 23 V at I
out
= 2 C 1/h
(C = total connected battery capacity in Ah), 19 V switch-off threshold for deep discharge protection
Output current I
out
3)
0 ... 6 A (permanently permissible) 0 ... 15 A (permanently
permissible)
0 ... 40 A (permanently
permissible)
Dynamic current with overload Electronic current limitation to 1.05 ... 1.4 I
out rated
for approx. 80 ms, then latching switch-off of
output (restart following return to normal operation)
Dynamic current with short-circuit Electronic current limitation to 1.5 ... 3 I
out rated
for approx. 20 ms, then latching switch-off of
output (restart following return to normal operation)
KT10_EN_gesamt.book Seite 14 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
DC UPS modules 6 A, 15 A, 40 A
12/15
Siemens KT 10.1 2012
12
Technical specifications (continued).
4)
Permissible contact rating: 60 V DC/1 A or 30 V AC/1 A.
5)
"24 V DC OK" means: Voltage of the power supply unit is greater than the battery connection threshold set on the DC UPS module.
Product DC UPS module DC UPS module DC UPS module
Power supply, type 6 A 15 A 40 A
Order No. 6EP1 931-2DC21
6EP1 931-2DC31
(with serial interface)
6EP1 931-2DC42
(with USB interface)
6EP1 931-2EC21
1)
6EP1 931-2EC31
(with serial interface)
6EP1 931-2EC42
(with USB interface)
6EP1 931-2FC21
6EP1 931-2FC42
(with USB interface)
Output + Bat / Bat in normal operation
Output +Bat/-Bat
in normal operation
I-V charging characteristic
(first constant current I,
then constant voltage V)
I-V charging characteristic
(first constant current I,
then constant voltage V)
I-V charging characteristic
(first constant current I,
then constant voltage V)
End-of-charge voltage V 26.6 V DC 0.1 V (factory setting
for +40 C battery temperature),
adjustable in the range
26.3 to 29.3 V (in 0.1 V
increments)
26.6 V DC 0.1 V (factory setting
for +40 C battery temperature),
adjustable in the range
26.3 to 29.3 V (in 0.1 V
increments)
26.6 V DC 0.1 V (factory setting
for +40 C battery temperature),
adjustable in the range
26.3 to 29.3 V (in 0.1 V
increments)
Charging current I Approx. 0.4 A (factory setting),
adjustable to 0.2 A or 0.4 A
(charging is carried out with
closed and open on/off circuit)
At a battery voltage of < 6 V
(batteries defective), charging is
not carried out as a protective
measure.
Approx. 0.7 A (factory setting),
adjustable to 0.35 A or 0.7 A
(charging is carried out with
closed and open on/off circuit)
At a battery voltage of < 6 V
(batteries defective), charging is
not carried out as a protective
measure.
Approx. 2 A (factory setting),
adjustable to 1 A or 2 A
(charging is carried out with
closed and open on/off circuit)
At a battery voltage of < 6 V
(batteries defective), charging is
not carried out as a protective
measure.
Efficiency/heat loss
At V
out rated
, I
out rated
approx. 95 % / 7 W 96.2 % / 14 W 97.2 % / 28.6 W
With battery operation, approx. 94.5 % / 8 W 96 % / 15 W 96V
in
% / 33.6 W
Protection and monitoring
Reverse polarity protection Against polarity reversal on input
voltage and batteries
Against polarity reversal on input
voltage and batteries
Against polarity reversal on input
voltage and batteries
Overload protection In accordance with "dynamic current with overload" in normal operation (automatic restart attempts) or in battery
mode (restart following return to normal operation)
Short-circuit protection In accordance with "dynamic current with short-circuit" in normal operation (automatic restart attempts)
or in battery mode (restart following return to normal operation). Built-in (not accessible) 16 A fuse
(6 A and 15 A on DC UPS module) or 64 A fuse (40 A on DC UPS module).
Exhaustive discharge protection Automatic shutdown when battery voltage falls below approx. 19 V.
At a battery voltage of < 6 V (batteries defective), charging is not carried out as a protective measure.
Monitoring
"Wire breakage in battery circuit"
Alarm signal if battery circuit not closed or if it opens during operation
(cyclic test approximately every 20 s)
Monitoring
"Battery replacement required"
Alarm signal flashing at approx.
0.25 Hz repetition frequency
(approx. 2 s alarm, approx. 2 s no
alarm, approx. 2 s alarm, etc.).
Check every 4 hours with
6 ohm load for 1 s if no buffer
mode or switch-off has taken
place within 4 hours.
Alarm signal flashing at approx.
0.25 Hz repetition frequency
(approx. 2 s alarm, approx. 2 s no
alarm, approx. 2 s alarm, etc.).
Check every 4 hours with
3 ohm load for 1 s if no buffer
mode or switch-off has taken
place within 4 hours.
Alarm signal flashing at approx.
0.25 Hz repetition frequency
(approx. 2 s alarm, approx. 2 s
no alarm, approx. 2 s alarm, etc.).
Check every 4 hours with
1 ohm load for 1 s if no buffer
mode or switch-off has taken
place within 4 hours.
No monitoring if switch position of
compatibility switch is "On"!
Monitoring "Battery charge > 85 %" Indication whether batteries are charged to at least 85 % of residual capacity still available depending on aging
Signaling
4)

Normal operation Green LED (OK) and isolated changeover contact "24 V DC OK / Bat" at setting "24 V DC OK"
5)
Buffer or battery mode (battery
supplies load alone or in addition to
PS in the case of overload)
Yellow LED (Bat) and isolated changeover contact "24 V DC OK / Bat" at setting "Bat" (= de-energized position)
Alarm (buffer not ready
or pre-warning from < 20.4 V
battery voltage)
Red LED (Alarm) and isolated changeover contact at setting "Alarm" (= de-energized position).
Causes of the buffer not being ready during normal operation can include: Off status or open on/off control circuit,
battery module not connected, polarity reversal or defective battery (battery voltage< 18.5 V) or wire breakage
between battery and UPS module. Scanning and thus updating of the signal every 20 s.
Causes of the buffer not being available during buffer operation can include: Accumulator voltage has dropped
below 20.4 V DC (= pre-warning before shutdown through exhaustive discharge protection) and shutdown of the
accumulator due to overload, short-circuit, exhaustive discharge protection or expired buffer time. The red LED
then goes out.
"Battery replacement required" Red LED (alarm) flashing at 0.25 Hz and floating changeover contact (alarm) switching at approx. 0.25 Hz
"Battery charge > 85 %" Second green LED (Bat > 85 %) and floating NO contact closed (de-energized position = open)
KT10_EN_gesamt.book Seite 15 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
DC UPS modules 6 A, 15 A, 40 A
12/16
Siemens KT 10.1 2012
12
Technical specifications (continued)
Product DC UPS module DC UPS module DC UPS module
6 A 15 A 40 A
Power supply, type 6EP1 931-2DC21
6EP1 931-2DC31
(with serial interface)
6EP1 931-2DC42
(with USB interface)
6EP1 931-2EC21
1)

6EP1 931-2EC31
(with serial interface)
6EP1 931-2EC42
(with USB interface)
6EP1 931-2FC21
6EP1 931-2FC42
(with USB interface)
Order No. 6 A 15 A 40 A
Signaling
4)

Compatibility switch Only on 6EP1 931-2FC21
The following can be selected using DIP switches: Switch position "Off" - "significant properties analogous to new
DC UPS range" or "On" switch position - "analogous to previous DC UPS module 40 (6EP1931-2FC01)".
With compatibility switch in "On" position:
Output of the Alarm signal changes: - The red LED flashes on wire-break between rechargeable battery and
UPS DC module with
1
/
3
Hz and isolated changeover contact (alarm) switching at approx.
1
/
3
Hz.
A battery test does not take place.
Optional port and software
Serial interface Only on 6EP1 931-2.C31
Output of all alarm signals and receipt of the "Remote timer start" signal. Technical design: PC-compatible. 8N1
send and receive,
9600 baud, 8 data bits, 1 stop bit, no parity bit. Required connection to the PC: 1 : 1 interconnected 9-pole sub
D extension cable (connector/socket); only pin 2 (RXD), pin 3 (TDX) and pin 7 (RTS) are required.
USB interface Only on 6EP1 931-2.C42
Output of all alarm signals and receipt of the "Remote timer start" signal. Technical design: Specification 2.0 with
full speed, i.e. 2 Mbit/s. Supplied with +5 V by DC UPS ("self powered"). Required connection to the PC:
Commercially available 4-core shielded cable, 90 ohm, max. 5 m, USB series "A" connector to PC and USB
series "B" connector to DC UPS
Software A software tool for reading out and processing the signals (can run under Windows 2000, Windows XP, Windows
Vista and Windows 7) is available for downloading from the Internet at https://www.siemens.com/sitop-ups. This
site also provides more information on the interface.
Control signals
On/off control signal Buffering is terminated or the battery is disconnected from the output by opening the control circuit or by means
of DIP switches on the device (DIP switch must be in "Off" position). All other functions are retained.
"Remote Timer start" via serial
interface or USB
Starts mains buffering for the set
buffer time
Starts mains buffering for the set
buffer time
Starts mains buffering for the set
buffer time
Safety
Primary/secondary isolation No No No
Protection class Class III (ext. circuit and power-
supply unit: SELV in accordance
with EN 60950 required)
Class III (ext. circuit and power-
supply unit: SELV in accordance
with EN 60950 required)
Class III (ext. circuit and power-
supply unit: SELV in accordance
with EN 60950 required)
EMC
Emitted interference according to EN 55022. Class B according to EN 55022. Class B according to EN 55022. Class B
Noise immunity according to EN 61000-6-2 according to EN 61000-6-2 according to EN 61000-6-2
Ambient conditions
Ambient temperature during
operation
-25 ... +60 C with natural
convection
-25 ... +60 C with natural
convection
-25 ... +60 C with natural
convection
Transport/storage temperature -40 ... +85 C -40 ... +85 C - 40 ... +85 C
Degree of protection (EN 60529) IP20 IP20 IP20
Humidity class Conditions of use in accordance
with EN 60721, climate class 3K3
(relative humidity 5 % to 85 % and
absolute humidity
1 g/m
3
to 25 g/m
3
; no
condensation)
Conditions of use in accordance
with EN 60721, climate class 3K3
(relative humidity 5 % to 85 % and
absolute humidity
1 g/m
3
to 25 g/m
3
; no
condensation)
Conditions of use in accordance
with EN 60721, climate class 3K3
(relative humidity 5 % to 85 % and
absolute humidity
1 g/m
3
to 25 g/m
3
; no
condensation)
KT10_EN_gesamt.book Seite 16 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS with battery modules
DC UPS modules 6 A, 15 A, 40 A
12/17
Siemens KT 10.1 2012
12
Technical specifications (continued)
Product DC UPS module DC UPS module DC UPS module
6 A 15 A 40 A
Power supply, type 6EP1 931-2DC21
6EP1 931-2DC31
(with serial interface)
6EP1 931-2DC42
(with USB interface)
6EP1 931-2EC21
1))

6EP1 931-2EC31
(with serial interface)
6EP1 931-2EC42
(with USB interface)
6EP1 931-2FC21
6EP1 931-2FC42
(with USB interface)
Order No. 6 A 15 A 40 A
Approvals
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2
No.107.1), File E197259
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259
Mechanics
Input connections 24 V DC 2 screw terminals
for 1 ... 4 mm
2
/17 ... 11 AWG
2 screw terminals
for 1 ... 4 mm
2
/17 ... 11 AWG
2 screw terminals for
0.33 ... 10 mm
2
/22 ... 7 AWG
Output connections 24 V DC 4 screw terminals for
1 ... 4 mm
2
/17 ... 11 AWG
4 screw terminals for
1 ... 4 mm
2
/17 ... 11 AWG
4 screw terminals for
0.33 ... 10 mm
2
/22 ... 7 AWG
Connections for rechargeable
battery 24 V DC
2 screw terminals
for 1 ... 4 mm
2
/17 ... 11 AWG
2 screw terminals
for 1 ... 4 mm
2
/17 ... 11 AWG
2 screw terminals for
0.33 ... 10 mm
2
/22 ... 7 AWG
Connections for control circuit and
alarm signals
10 screw terminals for
0.5 ... 2.5 mm
2
/20 ... 13 AWG
10 screw terminals for
0.5 ... 2.5 mm
2
/20 ... 13 AWG
10 screw terminals for
0.5 ... 2.5 mm
2
/20 ... 13 AWG
Dimensions (W H D) in mm 50 125 approx. 125 50 125 approx. 125 102 125 125
Weight, approx. 0.4 kg (with serial or USB
interface: 0.45 kg)
0.4 kg (with serial or USB
interface: 0.45 kg)
1.1 kg (with serial or USB
interface: 1.1 kg)
Installation Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 17 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Battery modules
12/18
Siemens KT 10.1 2012
12
Overview

Technical specifications
1)
For storage, mounting and operation of lead-acid batteries, the relevant DIN/VDE regulations or country-specific regulations
(e.g. VDE 0510 Part 2/EN 50272-2) must be observed. You must ensure that the battery site is sufficiently ventilated. Possible sources of ignition must be at
least 50 cm away.
Product Battery module 1.2 Ah Battery module 2.5 Ah Battery module 3.2 Ah
Battery type Maintenance-free
lead-acid batteries
Maintenance-free
pure lead batteries
Maintenance-free, sealed lead-
acid batteries
Order No. 6EP1 935-6MC01 6EP1 935-6MD31 6EP1 935-6MD11
Battery module for DC UPS
module 6 A
It has two maintenance-free,
closed lead-acid batteries (from
the same lot) which are installed in
a holder and connected in series
with corrosion-resistant lead-cal-
cium high-performance grid
plates and glass fiber.
Completely prewired with battery
retainer and terminals
Low self-discharge rate of
approximately 3 % per month
(at +20 C)
High-temperature battery module
for DC UPS module 6 A and
15 A
It has two maintenance-free,
closed pure lead-acid batteries
(from the same lot), which are
installed in a holder and
connected in series.
Completely prewired with battery
retainer and terminals
Low self-discharge rate of
approximately 3 % per month
(at +20 C)
Battery module for DC UPS
module 6 A and 15 A
It has two maintenance-free,
closed lead-acid batteries (from
the same lot) which are installed in
a holder and connected in series
with corrosion-resistant lead-cal-
cium high-performance grid
plates and glass fiber.
Complete with battery retainer and
terminals
Low self-discharge rate of
approximately 3 % per month
(at +20 C)
Product Battery module 1.2 Ah Battery module 2.5 Ah Battery module 3.2 Ah
Battery type Maintenance-free
lead-acid batteries
Maintenance-free
pure lead batteries
Maintenance-free, sealed lead-
acid batteries
Order No. 6EP1 935-6MC01 6EP1 935-6MD31 6EP1 935-6MD11
Charging current/charging voltage
Maintenance-free, sealed lead-
acid batteries
Maintenance-free
pure lead-acid batteries
Maintenance-free, sealed lead-
acid batteries
Recommended end-of-charge
voltage (stand-by use), dependent
on battery temperature
27.8 V at +10 C
27.3 V at +20 C
26.8 V at +30 C
26.6 V at +40 C
29.0 V at 10 C
28.6 V at 0 C
28.3 V at +10 C
27.9 V at +20 C
27.5 V at +30 C
27.2 V at +40 C
26.8 V at +50 C
26.4 V at +60 C
27.8 V at +10 C
27.3 V at +20 C
26.8 V at +30 C
26.6 V at +40 C
Recommended charging current Max. 0.3 A Max. 5 A Max. 0.8 A
Protection
Short-circuit protection Battery fuse 7.5 A/32 V
(solid-state circuitry blade-type
fuse + support)
Battery fuse 15 A/32 V
(solid-state circuitry blade-type
fuse + support)
Battery fuse 15 A/32 V
(solid-state circuitry blade-type
fuse + support)
Battery protection Valve control Valve control Valve control
Safety
Protection class Class III Class III Class III
UL/cUL (CSA) approval cURus-recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
cURus-recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
cURus-recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
Degree of protection (EN 60529) IP00 IP00 IP00
Operating data
1)
Ambient temperature range 0 ... +40 C -40 ... +60 C with natural
convection
0 ... +40 C with natural
convection
Transport/storage temperature
range
-20 ... +50 C -40 ... +60 C - 20 ... +50 C
Self-discharge rate Approx. 3 % per month at 20 C
battery temperature (increases
with temperature)
Approx. 3 % per month at 20 C
battery temperature (increases
with temperature)
Approx. 3 % per month at 20 C
battery temperature (increases
with temperature)
KT10_EN_gesamt.book Seite 18 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Battery modules
12/19
Siemens KT 10.1 2012
12
Battery module 7 Ah Battery module 12 Ah
Maintenance-free, sealed lead-
acid batteries
Maintenance-free, sealed lead-
acid batteries
6EP1 935-6ME21 6EP1 935-6MF01
Battery module for DC UPS
module 6 A, 15 A, and 40 A
(for > 20 to 40 A, 2 modules are
required in parallel).
It has two maintenance-free,
closed lead-acid batteries (from
the same lot) which are installed in
a holder and connected in series
with corrosion-resistant lead-cal-
cium high-performance grid
plates and glass fiber.
Completely pre-wired with termi-
nals and battery retainer
Low self-discharge rate of
approximately 3 % per month
(at +20 C)
Battery module for DC UPS
module 6 A and 15 A and
DC UPS module 40 A (for > 20 to
40 A, 2 modules are required in
parallel)
It has two maintenance-free,
closed lead-acid batteries (from
the same lot) which are installed in
a holder and connected in series
with corrosion-resistant lead-cal-
cium high-performance grid
plates and glass fiber.
Completely pre-wired with
terminals and battery retainer
Low self-discharge rate of
approximately 3 % per month
(at +20 C).
Battery module 7 Ah Battery module 12 Ah
Maintenance-free, sealed lead-
acid batteries
Maintenance-free, sealed lead-
acid batteries
6EP1 935-6ME21 6EP1 935-6MF01
Maintenance-free, sealed lead-
acid batteries
Maintenance-free, closed lead-
acid batteries
27.8 V at +10 C
27.3 V at +20 C
26.8 V at +30 C
26.6 V at +40 C
27.8 V at +10 C
27.3 V at +20 C
26.8 V at +30 C
26.6 V at +40 C
Max. 1.75 A Max. 3 A
Battery fuse 30 A/32 V
(solid-state circuitry blade-type
fuse + support)
Battery fuse 30 A/32 V
(solid-state circuitry blade-type
fuse + support)
Valve control Valve control
Class III Class III
UL/cUL-Recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
cURus-recognized (UL 1778, CSA
C22.2 No. 107.1), File E219627
IP00 IP00
0 ... +40 C 0 ... +40 C
20 ... +50 C 20 ... +50 C
Approx. 3 % per month at 20 C
battery temperature
Approx. 3 % per month at 20 C
battery temperature
KT10_EN_gesamt.book Seite 19 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Battery modules
12/20
Siemens KT 10.1 2012
12
Technical specifications (continued)
.
1)
Along with the storage and operating temperature, other factors such as the duration of the storage period and the charge status during storage have a
decisive influence on the possible useful life. Batteries should therefore be stored as briefly as possible, always fully charged, and within the temperature
range 0 to +20 C.
Product Battery module 1.2 Ah Battery module 2.5 Ah Battery module 3.2 Ah
Battery type Maintenance-free
lead-acid batteries
Maintenance-free
pure lead batteries
Maintenance-free, sealed lead-
acid batteries
Order No. 6EP1 935-6MC01 6EP1 935-6MD31 6EP1 935-6MD11
Battery life
1)
The service life of the lead-acid
batteries (when capacity falls to
50 % of original capacity) depends
on the battery temperature as
follows:
Approx. 4 years at +20 C
Approx. 2 years at +30 C
Approx. 1 year at +40 C
Approx. >10 years at +20 C
Approx. 7 years at +30 C
Approx. 3 years at +40 C
Approx. 1.5 years at +50 C
Approx. 1 year at +60 C
Approx. 4 years at +20 C
Approx. 2 years at +30 C
Approx. 1 year at +40 C
Mechanics
Connection 1 screw terminal each for
0.08 to 2.5 mm
2
for +BAT
and BAT
1 screw terminal each for
0.08 to 2.5 mm
2
for +BAT
and BAT
1 screw terminal each for
0.08 to 2.5 mm
2
for +BAT
and BAT
Accessories, included Accessories pack with solid-state
circuitry fuse 7.5 A
Accessories pack with solid-state
circuitry fuse 15 A
Accessories pack with solid-state
circuitry fuse 15 A
Dimensions (W H D) in mm 96 106 108 265 151 91 190 151 82
Weight, approx. 1.8 kg 3.8 kg 3.2 kg
Installation Snaps onto DIN rail
EN 60715 357.5/15 or keyhole
mounting for hooking in to M4
screws
Snaps onto DIN rail
EN 60715 357.5/15 or keyhole
mounting for hooking in to M4
screws
Snaps onto DIN rail
EN 60715 357.5/15 or keyhole
mounting for hooking in to M4
screws
KT10_EN_gesamt.book Seite 20 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
Battery modules
12/21
Siemens KT 10.1 2012
12
Battery module 7 Ah Battery module 12 Ah
Maintenance-free, sealed lead-
acid batteries
Maintenance-free, sealed lead-
acid batteries
6EP1 935-6ME21 6EP1 935-6MF01
Approx. 4 years at +20 C
Approx. 2 years at +30 C
Approx. 1 year at +40 C
Approx. 4 years at +20 C
Approx. 2 years at +30 C
Approx. 1 year at +40 C
1 screw terminal each for
0.08 to 4 mm
2
for +BAT
and BAT
1 screw terminal each for
0.08 to 4 mm
2
for +BAT
and BAT
Accessories pack with spare
solid-state circuitry fuse 15 A and
30 A
Accessories pack with spare
solid-state circuitry fuse 15 A and
30 A
186 168 121 253 168 121
6.0 kg 9.0 kg
Can be screwed onto flat surface
("keyhole mounting" for hooking
onto M4 screws)
Can be screwed onto flat surface
("keyhole mounting" for hooking
onto M4 screws)
KT10_EN_gesamt.book Seite 21 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP Uninterruptible power supplies (UPS)
24 V DC
DC UPS
12/22
Siemens KT 10.1 2012
12
Selection and ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Product Input Output; Energy Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP UPS500S
24 V DC 24 V DC; 2.5 kWs 15 A 6EP1 933-2EC41
24 V DC 24 V DC; 5 kWs 15 A 6EP1 933-2EC51
SITOP UPS501S
24 V DC 24 V DC; 5 kWs 15 A 6EP1 935-5PG01
SITOP UPS500P
24 V DC 24 V DC; 5 kWs 7 A 6EP1 933-2NC01
24 V DC 24 V DC; 10 kWs 7 A 6EP1 933-2NC11
Connector set
Connector set with connector for input and output with
pre-assembled USB cable (2 m long)
6EP1 975-2ES00
DC UPS module
24 V DC 24 V DC 6 A 6EP1 931-2DC21
24 V DC 24 V DC,
with serial interface
6 A 6EP1 931-2DC31
24 V DC 24 V DC,
with USB interface
6 A 6EP1 931-2DC42
24 V DC 24 V DC 15 A 6EP1 931-2EC21
24 V DC 24 V DC,
with serial interface
15 A 6EP1 931-2EC31
24 V DC 24 V DC,
with USB interface
15 A 6EP1 931-2EC42
24 V DC 24 V DC 40 A 6EP1 931-2FC21
24 V DC 24 V DC,
with USB interface
40 A 6EP1 931-2FC42
Battery modules
Capacity:
1.2 Ah 6EP1 935-6MC01
2.5 Ah, high-temperature battery module 6EP1 935-6MD31
3.2 Ah 6EP1 935-6MD11
7 Ah 6EP1 935-6ME21
12 Ah 6EP1 935-6MF01
KT10_EN_gesamt.book Seite 22 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
13
13/2 Output voltage 3-52 V
SITOP flexi
13/4 Output voltage 5 V
13/4 LOGO!Power 5 V/3 A
13/4 LOGO!Power 5 V/6.3 A
13/6 Output voltage 12 V
13/6 LOGO!Power 12 V/1.9 A
13/6 SITOP PSU100C 12 V/2 A
13/6 SITOP DC/12 V DC/2.5 A
13/7 PSU100D 12 V/3 A
13/7 LOGO!Power 12 V/4.5 A
13/7 SITOP PSU100C 12 V/6.5 A
13/10 PSU100D 12 V/8.3 A
13/10 SITOP PSU300B 12 V/20 A
13/12 Output voltage 15 V
13/12 LOGO!Power 15 V/1.9 A
13/12 LOGO!Power 15 V/4 A
13/12 SITOP dual 2 x 15 V/3.5 A
13/14 Output voltage 48 V
13/14 SITOP PSU300M 48 V/10 A
13/14 SITOP modular 48 V/20 A
13/16 Ordering data and additional
information
SITOP
Alternative voltages
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltages 3 - 52 V
13/2
Siemens KT 10.1 2012
13
Overview

Technical specifications
Product Special design
SITOP flexi
Power supply, type 3-52 V/2-10 A
Order No. 6EP1 353-2BA00
The power supply with flexible output voltage from
3 to 52 V; suitable for all application areas requiring a
special voltage other than 24 V.
Product Special design
SITOP flexi
Input
1-phase AC
Rated voltage value V
in rated
120/230 V AC
Set via wire jumper
Voltage range 85 ... 132 V/170 ... 264 V
Overvoltage resistance 2.3 V
in

rated
.1.3 ms
Mains buffering at I
out rated
> 10 ms at V
in
= 93/187 V
(P
a
= 120 W)
Rated line frequency value; range 50/60 Hz, 47 ... 63 Hz
Rated current I
in rated
2.2/0.9 A
Switch-on current limit (+25 C) < 32 A
I
2
t < 0.8 A
2
s
Built-in incoming fuse T 3.15 A/250 V (not accessible)
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
From 6 A, characteristic C
Output
Controlled, isolated DC voltage
Rated voltage V
out rated
3-52 V DC
Total tolerance 1 %
Static line compensation Approx. 0.1 %
Static load compensation Approx. 0.2 %
Sense line connection Yes, maximum voltage control 0.5 V per line
Residual ripple < 50 mV
pp
(typ. 20 mV
pp
)
Spikes (bandwidth: 20 MHz) < 100 mV
pp
(typ. 80 mV
pp
)
Adjustment range 3 ... 52 V, via potentiometer or analog control voltage signal 0 ... 2.5 V
Status display Green LED for 24 V OK
Signaling Power good via relay contact, current monitor signal 0 ... 2.5 V
On/off behavior No overshoot of V
out

(soft start)
Startup delay /
voltage rise
< 3 s/typ. 80 ms
Rated current value I
out rated
2 to 10 A (max. 120 W)
Current range
Up to +60 C 0 ... 10 A (max. 120 W)
Derating
Dynamic overcurrent on
Power-up on short-circuit Constant current 2 ... 10 A
Short circuit during operation Constant current 2 ... 10 A
Parallel switching for
enhanced performance
Yes, 2 units
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltages 3 - 52 V
13/3
Siemens KT 10.1 2012
13
Technical specifications (continued)
Product Special design
SITOP flexi
Power supply, type 3-52 V/2-10 A
Order No. 6EP1 353-2BA00
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 84 % (at 24 V/5 A)
Power loss at V
out rated
, I
out rated
Approx. 23 W (at 24 V/5 A)
Protection and monitoring
Output overvoltage protection Yes, according to EN 60950
Current limitation 2 ... 10 A, adjustable by potentiometer or with analog control voltage signal 0 ... 2.5 V
Short-circuit protection Electronic current limitation
(2 ... 10 A) in the range 3 ... 12 V or power limitation (120 W) in the range 12 ... 52 V
Sustained short-circuit current rms
value
matching the set current limitation 2 ...10 A
Overload/short-circuit indicator Red LED for current or power limiting
Safety
Primary/secondary isolation Yes, SELV output voltage V
out
according to EN 60950-1 and EN 50178
Protection class Class I
Leakage current < 3.5 mA
Safety test Yes
CE mark Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289
Degree of protection (EN 60529) IP20
EMC
Emitted interference EN 55022 Class B
Supply harmonics limitation EN 61000-3-2
Noise immunity EN 61000-6-2
Operating data
Permitted ambient temperature 0 ... +60 C with natural convection
Transport/storage temperature
range
-40 ... +85 C
Humidity class Climate class 3K3 according to EN 60721, no
condensation
Mechanics
Connections
Supply input L1, N, PE One screw-type terminal each for 0.5 mm to 2.5 mm
2
Output + 1 screw terminal for 0.5 ... 2.5 mm
2
(L+) und
Output - 2 screw-type terminals for 0.5 ... 2.5 mm
2
(M)
Alarm signals, control inputs Screw terminals for 0.14 ... 1.5 mm
2
Dimensions (W x H x D) in mm 75 125 125
Weight, approx. 0.9 kg
Installation Snaps onto DIN rail EN 60715 35x7.5/15
Accessories

KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
SITOP
Alternative voltages
Output voltage 5 V
13/4
Siemens KT 10.1 2012
13
Overview

Technical specifications
Product LOGO!Power LOGO!Power
Power supply, type 5 V/3 A 5 V/6.3 A
Order No. 6EP1 311-1SH03 6EP1 311-1SH13
LOGO!Power supplies are optimally matched in design and functionality to the LOGO! logic modules;
with wide-range input 85 V to 264 V AC and option for installing in built-in miniature distribution boards,
they can be used universally in the low-end performance range.
It is also possible to operate them with 110 V DC to 300 V DC.
Product LOGO!Power LOGO!Power
Input
1-phase AC or DC 1-phase AC or DC
Rated voltage value V
in rated
100-240 V AC
Wide-range input
100-240 V AC
Wide-range input
Voltage range AC 85 ... 264 V
DC 110 ... 300 V
AC 85 ... 264 V
DC 110 ... 300 V
Overvoltage resistance 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
Line buffering at I
out rated
> 40 ms at V
in
= 187 V > 40 ms at V
in
= 187 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
0.36-0.22 A 0.71-0.37 A
Switch-on current limit (+25 C) < 26 A < 50 A
I
2
t < 0.8 A
2
s < 3 A
2
s
Built-in incoming fuse Internal Internal
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
16 A or higher, characteristic B or 10 A or higher,
characteristic C
16 A or higher, characteristic B or 10 A or higher,
characteristic C
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
5 V DC 5 V DC
Total tolerance, static 3 % 3 %
Static mains compensation Approx. 0.2 % Approx. 0.1 %
Static load balancing Approx. 1.5 % Approx. 2 %
Residual ripple < 100 mV
pp
(typ. 10 mV
pp
) < 100 mV
pp
(typ. 15 mV
pp
)
Spikes (bandwidth approx. 20 MHz) < 100 mV
pp
(typ. 20 mV
pp
) < 100 mV
pp
(typ. 70 mV
pp
)
Adjustment range 4.6 ... 5.4 V 4.6 ... 5.4 V
Status display Green LED for 5 V OK Green LED for 5 V OK
On/off behavior No overshoot of V
out

(soft start)
No overshoot of V
out

(soft start)
Startup delay /
voltage rise
< 0.5 s/typ. 15 ms < 0.5 s/typ. 10 ms
Rated current value I
out rated
3 A 6.3 A
Current range
Up to +55 C 0 ... 3 A 0 ... 6.3 A
Derating 0 ... 2.1 A (up to +70 C) 0 ... 4.4 A (up to +70 C)
Parallel switching for enhanced
performance
Yes, 2 units Yes, 2 units
NEW NEW
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 5 V
13/5
Siemens KT 10.1 2012
13
Technical specifications (continued)
Product LOGO!Power LOGO!Power
Power supply, type 5 V/3 A 5 V/6.3 A
Order No. 6EP1 311-1SH03 6EP1 311-1SH13
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 77 % Approx. 83 %
Power loss at V
out rated
, I
out rated
Approx. 4 W Approx. 6 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
<0.2 % V
out
<0.2 % V
out
Dynamic load smoothing
(I
out
: 10/90/10 %)
Typ. 3 % V
out
Typ. 3 % V
out
Load-step settling time
10 at 90 % Typ. 2 ms Typ. 2 ms
90 at 10 % Typ. 2 ms Typ. 2 ms
Protection and monitoring
Current limitation Typically 3.8 A Typically 8.2 A
Short-circuit protection Constant current characteristic Constant current characteristic
Sustained short-circuit current rms
value
< 5 A < 10 A
Overload/short-circuit indicator
Safety
Primary/secondary isolation Yes, SELV output voltage V
out
according to
EN 60950-1 and EN 50178
Yes, SELV output voltage V
out
according to
EN 60950-1 and EN 50178
Protection class Class II (without protective conductor)) Class II (without protective conductor))
Safety test Yes; CB Scheme Yes; CB Scheme
CE mark Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1), File
E197259; cURus-Recognized (UL 60950, CSA C22.2
No. 60950), File E197259
cULus-Listed (UL 508, CSA C22.2 No. 107.1), File
E197259; cURus-Recognized (UL 60950, CSA C22.2
No. 60950), File 197259
Explosion protection ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079), Class I, Div. 2.
Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079), Class I, Div. 2.
Group ABCD, T4
FM approval Class I, Div. 2. Group ABCD, T4 Class I, Div. 2. Group ABCD, T4
Marine approval GL GL
Degree of protection (EN 60529) IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B
Supply harmonics limitation Not applicable Not applicable
Noise immunity EN 61000-6-2 EN 61000-6-2
Operating data
Permitted ambient temperature - 20 ... +70 C with natural convection -20 ... +70 C with natural convection
Transport/storage temperature
range
- 40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Supply-input connections L1, N One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely stranded
Connections
Output +
Output
2 screw terminals for
0.5 to 2.5 mm
2
2 screw terminals for
0.5 to 2.5 mm
2
Dimensions (W H D) in mm 54 90 55 72 90 55
Weight, approx. 0.17 kg 0.25 kg
Installation Snaps onto DIN rail
EN 60715 357.5/15
Snaps onto DIN rail
EN 60715 357.5/15
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 12 V
13/6
Siemens KT 10.1 2012
13
Overview

Technical specifications
1)
The supply voltage must be securely isolated (SELV or PELV) from the feeding AC mains.
Product LOGO!Power SITOP compact
PSU100C
Special design
SITOP DC/DC
Power supply, type 12 V/1.9 A 12 V/2 A 12 V/2.5 A
Order No. 6EP1 321-1SH03 6EP1 321-5BA00 6EP1 621-2BA00
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
LOGO!Power supplies are
optimally matched in design and
functionality to the LOGO! logic
modules; with wide-range input
85 V to 264 V AC and option for
installing in built-in miniature
distribution boards, they can be
used universally in the low-end
performance range. It is also
possible to operate them with
110 V DC to 300 V DC.
Narrow power supply suitable for
the lower performance range, e.g.
for distributed use in switching
cubicles. Low energy
consumption thanks to a high
degree of efficiency across the
entire power range and minimum
power loss in no-load operation.
DC/DC converter for connection to
24 V DC networks over permanent
wiring.
Output voltage 12 V DC, isolated,
short-circuit proof, and no-load
resistant.
Product LOGO!Power SITOP compact
PSU100C
Special design
SITOP DC/DC
Input
1-phase AC or DC 1-phase AC or DC DC voltage (SELV or PELV)
Rated voltage value V
in rated
100-240 V AC
Wide-range input
100 - 230 V AC
Wide-range input
24 V DC
1)
Voltage range 85 ... 264 V AC
110 ... 300 V DC
85 ... 264 V AC or 110 ... 300 V DC 18.5 ... 30.2 V
Overvoltage resistance 2.3 V
in

rated
, 1.3 ms 2.3 x V
in

rated
, 1.3 ms
Mains buffering at I
out rated
> 40 ms at V
in
= 187 V > 20 ms at V
in
= 230 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
0.53-0.3 0.63-0.31 A 2.5 A
Switch-on current limit (+25 C) < 25 A < 33 A < 20 A
I
2
t < 0.8 A
2
s < 1.2 A
2
s
Built-in incoming fuse Internal Internal (not accessible)
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
16 A or higher, characteristic B or
10 A or higher, characteristic C
16 A or higher, characteristic B or
10 A or higher, characteristic C
10 A, characteristic B
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated
DC voltage
Rated voltage V
out rated
12 V DC 12 V DC 12 V DC
Total tolerance 3 % 3 % 3 %
Static line compensation Approx. 0.1 % ca. 0.1 %
Static load compensation Approx. 1.5 % ca. 0.4 %
Residual ripple < 200 mV
pp
(typ. 10 mV
pp
) < 200 mV
pp
(typ. 40 mV
pp
) < 100 mV
pp
Spikes (bandwidth: 20 MHz) < 300 mV
pp
(typ. 20 mV
pp
) < 300 mV
pp
(typ. 55 mV
pp
) < 200 mV
pp
Adjustment range 10.5 ... 16.1 V 10.5 ... 12.9 V 12 ... 14 V
Status display Green LED for 12 V OK Green LED for 12 V OK Green LED for 12 V OK
On/off behavior No overshoot of V
out

(soft start)
Overshoot of V
out
approx. 5 %
Startup delay /
voltage rise
< 0.5 s/typ. 10 ms < 0.6 s/typ. 10 ms < 0.5 s/typ. 300 ms
Rated current value I
out rated
1.9 A 2 A 2.5 A
Current range
Up to +60 C 0 ... 1.9 A (up to +55 C) 0 ... 2.0 A (up to +55 C) 0 ... 2.5 A
Derating 0 ... 1.3 A (up to +70 C) 0 ... 1.1 A (up to +70 C)
Dynamic overcurrent on
Power-up on short-circuit 3.3 A
Short circuit during operation 3.3 A
NEW NEW
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 12 V
13/7
Siemens KT 10.1 2012
13
Special design
PSU100D
LOGO!Power SITOP compact
PSU100C
12 V/3 A 12 V/4.5 A 12 V/6.5 A
6EP1 321-1LD00 6EP1 322-1SH03 6EP1 322-5BA10
This cost-effective power supply features a flat
aluminium housing and can be fastened to a
wall in several mounting positions;
with wide-range input for global use.
LOGO!Power supplies are optimally matched in
design and functionality to the LOGO! logic
modules; with wide-range input 85 V to 264 V
AC and option for installing in built-in miniature
distribution boards, they can be used
universally in the low-end performance range.
Can also run with DC voltage 110 V to 300 V
DC.
Narrow power supply for the lower performance
range, e.g. for distributed use in switching
cubicles. Low energy consumption thanks to a
high degree of efficiency across the entire
power range and minimum power loss in no-
load operation.
Special design
PSU100D
LOGO!Power SITOP compact
PSU100C
1-phase AC 1-phase AC or DC 1-phase AC or DC
100-240 V AC
Wide-range input
100-240 V AC
Wide-range input
100 - 230 V AC
Wide-range input
85 ... 264 V 85 ... 264 V AC
110 ... 300 V DC
85 ... 264 V AC or 110 ... 300 V DC
2.3 V
in

rated
, 1.3 ms 2.3 x V
in

rated
, 1.3 ms
> 15 ms at V
in
= 115/230 V > 40 ms at V
in
= 187 V > 20 ms at V
in
= 230 V
50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
0.75 to 0.5 A 1.13-0.61 A 1.6-0.8 A
< 60 A < 55 A < 31 A
< 1.2 A
2
s < 3 A
2
s < 3 A
2
s
Internal Internal Internal
10 A or higher, characteristic C or
16 A or higher, characteristic B
10 A or higher, characteristic C or
16 A or higher, characteristic B
10 A or higher, characteristic C or
16 A or higher, characteristic B
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
Controlled, isolated
DC voltage
12 V DC 12 V DC 12 V DC
2 % 3 % 3 %
Approx. 0.5 % Approx. 0.1 %
Approx. 1.0 % Approx. 1.5 %
< 100 mV
pp
< 200 mV
pp
(typ. 10 mV
pp
) < 200 mV
pp
(typ. 80 mV
pp
)
< 100 mV
pp
< 300 mV
pp
(typ. 70 mV
pp
) < 300 mV
pp
(typ. 80 mV
pp
)
11.0 ... 14.0 V 10.5 ... 16.1 V 10.5 ... 12.9 V
Green LED for 12 V OK Green LED for 12 V OK Green LED for 12 V OK
Overshoot of V
out
< 2 % No overshoot of V
out

(soft start)
Overshoot of V
out
approx. 1 %
< 2.5 s/< 30 ms < 0.5 s/typ. 10 ms < 1 s/typ. 500 ms
3 A 4.5 A 6.5 A
0 ... 3 A (up to +50 C) 0 ... 4.5 A (up to +55 C) 0 ... 6.5 A (up to +55 C)
0 ... 1.5 A (up to +70 C) 0 ... 3.1 A (up to +70 C) 0 ... 1.95 A (up to +70 C)
NEW NEW NEW
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 12 V
13/8
Siemens KT 10.1 2012
13
Product LOGO!Power SITOP compact
PSU100C
Special design
SITOP DC/DC
Power supply, type 12 V/1.9 A 12 V/2 A 12 V/2.5 A
Order No. 6EP1 321-1SH03 6EP1 321-5BA00 6EP1 621-2BA00
Output (continued)
Parallel switching for
enhanced performance
Yes, 2 units Yes, 2 units Yes, 2 units
Efficiency
Efficiency at V
out rated
, I
out rated
ca. 80 % Approx. 82 % Approx. 83 %
Power loss at V
out rated
, I
out rated
Approx. 5 W 5.8 W Approx. 6.1 W
Closed-loop control
Dyn. mains compensation
(V
in

rated
15 %)
<0.2 % V
out
<0.1 % V
out
Dynamic load compensation
(I
out
: 10/90/10 %)
Typ. 3 % V
out
Typ. 3 % V
out
Load-step settling time
10 at 90 % Approx. 1 ms Approx. 4 ms
90 at 10 % Approx. 1 ms Approx. 3 ms
Protection and monitoring
Output overvoltage protection < 24 V < 24 V
Current limitation Typically 2.8 A 2.4 A 3.0 ... 3.6 A
Short-circuit protection Constant current characteristic Electronic shutdown, automatic restart Electronic shutdown, auto restart
Sustained short-circuit rms value < 3.6 A Approx. 4.5 A Approx. 3.6 A
Overload/short-circuit indicator Red LED
Safety
Primary/secondary isolation Yes, SELV output V
out
according to
EN 60950-1 and EN 50178
Yes, SELV output V
out
according to
EN 60950-1 and EN 50178
Yes, safety extra low output V
out

according to EN 60950-1
Protection class Class II (without protective
conductor))
Class I Class II
Leakage current < 3.5 mA (typ. 0.4 mA)
Safety test Yes; CB Scheme Yes; CB Scheme Yes
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cURus-Recognized (UL 60950,
CSA C22.2 No. 60950),
File E151273
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cCSAus (CSA C22.2 No. 60950-1,
UL 60950-1)
cCSAus (UL 508, CSA22.2-107,
UL 60950-1, CSA22.2-60950-1)
Explosion protection ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079,
UL 60079), Class I, Div. 2.
Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T4;
cCSAus (CSA C22.2 No. 213-M1987,
ANSI/ISA-12.12.01-2007) Class I,
Div. 2. Group ABCD, T4

FM approval Class I, Div. 2. Group ABCD, T4

Marine approval GL, ABS GL and ABS available soon

Degree of protection (EN 60529) IP20 IP20 IP20


EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation Not applicable Not applicable
Noise immunity EN 61000-6-2 EN 61000-3-2 EN 61000-6-2
Operating data
Permitted ambient temperature -20 ... +70 C with natural
convection
-20 ... +70 C with natural convection 0 ... +60 C with natural
convection
Transport, storage temp range - 40 ... +85 C -40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L1, N, PE One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely stranded
Removable screw terminals, one each
0.5 ... 2.5 mm
2
solid/finely stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
(L+, N, PE)
Output + 2 screw terminals for
0.5 to 2.5 mm
2
One screw terminal for 0.5 ... 2.5 mm
2
2 screw terminals for
0.5 to 2.5 mm
2

Output - 2 screw terminals for
0.5 to 2.5 mm
2
2 screw-type terminals for 0.5 mm to
2.5 mm
2
2 screw terminals for
0.5 to 2.5 mm
2

Dimensions (W x H x D) in mm 54 90 55 30 x 80 x 100 32.5 125 125
Weight, approx. 0.17 kg 0.17 kg 0.32 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Accessories
Removable spring-loaded terminals
(6EP1971-5BA00)

KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
SITOP
Alternative voltages
Output voltage 12 V
13/9
Siemens KT 10.1 2012
13
Special design
PSU100D
LOGO!Power SITOP compact
PSU100C
12 V/3 A 12 V/4.5 A 12 V/6.5 A
6EP1 321-1LD00 6EP1 322-1SH03 6EP1 322-5BA10
Yes, 2 units Yes, 2 units Yes, 2 units
Approx. 84 % Approx. 85 % Approx. 86 %
Approx. 6.5 W Approx. 10 W Approx. 12.5 W
Typ. 0.5 % V
out
<0.2 % V
out
Typ. 5 % V
out
(0 to 100 %) Typ. 4 % V
out
Typ. 100 ms (0 to 100 %) Approx. 1 ms
Typ. 100 ms (0 to 100 %) Approx. 1 ms
< 17.6 V Yes, according to EN 60950
3.6 A Typically 5.8 A
Electronic shutdown, automatic restart Constant current characteristic Electronic shutdown, automatic restart
6 A < 7 A

Yes, SELV output voltage V


out

according to EN 60950-1
Yes, SELV output voltage V
out

according to EN 60950-1 and EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and EN 50178
Class I Class II (without protective conductor)) Class I
< 3.5 mA (typ. 1 mA) < 3.5 mA (typ. 0.4 mA)
Yes; CB Scheme in preparation Yes; CB Scheme Yes; CB Scheme
Yes Yes Yes
cULus-Listed (UL 508, CSA C22.2 No. 107.1 in
preparation, UL 60950-1, CSA C22.2 No.
60950-1 in preparation)
cULus-listed (UL 508, CSA C22.2 No. 107.1),
File E197259; cURus-recognized (UL 60950,
CSA C22.2 No. 60950), File E151273
cULus-Listed (UL 508, CSA C22.2 No. 107.1),
File E197259;
cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)

ATEX (EX) II 3G Ex nA IIC T3;


cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T4

Class I, Div. 2. Group ABCD, T4

GL, ABS GL and ABS available soon


IP20 IP20 IP20
EN 55022 Class B EN 55022 Class B EN 55022 Class B
Not applicable Not applicable EN 61000-3-2
EN 61000-6-2 EN 61000-6-2 EN 61000-3-2
-10 ... +70 C with natural
convection
-20 ... +70 C with natural
convection
-20 ... +70 C with natural
convection
-25 ... +85 C - 40 ... +85 C -40 ... +85 C
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
One screw-type terminal each for
0.3 ... 1.3 mm
2
solid/finely stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely stranded
Removable screw terminals, one each
0.5 ... 2.5 mm
2
solid/finely stranded
1 screw terminal for 0.3 ... 1.3 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
1 screw terminal for 0.5 ... 2.5 mm
2
1 screw terminal for 0.3 ... 1.3 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
2 screw-type terminals for 0.5 mm to 2.5 mm
2
97 x 98 x 38 72 90 55 52.5 x 80 x 100
0.37 kg 0.25 kg 0.32 kg
Wall mounting Snaps onto DIN rail EN 60715 357.5/15 Snaps onto DIN rail EN 60715 357.5/15
Removable spring-loaded terminals
(6EP1971-5BA00)
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 12 V
13/10
Siemens KT 10.1 2012
13
Overview

Technical specifications
Product Special design
PSU100D
Special design
PSU300B
Power supply, type 12 V/8.3 A 12 V/20 A
Order No. 6EP1 322-1LD00 6EP1 424-3BA00
The low-cost power supply in flat aluminum housing can
be screwed directly on a wall in various mounting
positions; with wide-range input for global use.
This power supply is optimized for battery charging, it
features a 3-phase wide-range input suitable for
world-wide use; slim design; with switchable output
characteristic, function expansion is possible in
conjunction with expansion modules.
Product Special design
PSU100D
Special design
PSU300B
Input
1-phase AC 3-phase AC
Rated voltage value V
in rated
100-240 V AC Wide-range input 400-500 V 3 AC Wide-range input
Voltage range 85 ... 264 V 320 ... 575 V
Overvoltage resistance 2.3 x V
in rated
, 1.3 ms
Mains buffering at I
out rated
> 15 ms at V
in
= 115/230 V > 20 ms at V
in
= 400 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
2.0-1.1 A 0.7-0.6 A
Switch-on current limit (+25 C) < 75 A < 18 A
I
2
t < 5.5 A
2
s < 0.8 A
2
s
Built-in incoming fuse Internal None
Recommended miniature circuit
breaker
(IEC 898) in the mains power input
10 A or higher, characteristic C or 16 A,
characteristic B
Required:
3-pole connected miniature circuit breaker 6 ... 16 A,
characteristic C or circuit breaker 3RV2011-1DA10
(set to 3 A) or 3RV2711-1DD10 (UL 489)
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
12 V DC 12 V DC
Total tolerance 2 % 3 %
Static line compensation Approx. 0.5 % Approx. 0.2 %
Static load compensation Approx. 1.0 % Approx. 0.4 %
Residual ripple < 100 mV
pp
< 100 mV
pp
Spikes (bandwidth: 20 MHz) < 100 mV
pp
< 200 mV
pp
Adjustment range 11 ... 14 V 12 ... 14 V
Status display Green LED for 12 V O. K Green LED for 12 V OK
Signaling Relay contact (NO contact, contact rating
DC 60 V/0.3 A) for 12 V OK
On/off behavior Overshoot of V
out
<2 % No overshoot of V
out
(soft start)
Startup delay/voltage rise < 1 s/< 30 ms < 2.5 s/< 500 ms
Rated current value I
out rated
8.3 A 20 A
Current range
Up to +60 C 0 ... 8.3 A (up to +50 C) 0 ... 20 A
Derating 0 ... 4.1 A (up to +70 C) 20 A (up to +70 C)
Dynamic overcurrent on
Power-up on short-circuit Approx. 22 A constant current
Short circuit during operation Typ. 60 A for 25 ms
Parallel switching for
enhanced performance
Yes, 2 units Yes, 2 units (switchable characteristic)
NEW NEW
KT10_EN_gesamt.book Seite 10 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 12 V
13/11
Siemens KT 10.1 2012
13
Technical specifications (continued)
Product Special design
PSU100D
Special design
PSU300B
Power supply, type 12 V/8.3 A 12 V/20 A
Order No. 6EP1 322-1LD00 6EP1 424-3BA00
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 84 % Approx. 90 %
Power loss at V
out rated
, I
out rated
Approx. 19 W Approx. 20 W
Closed-loop control
Dyn. mains compensation
(V
in rated
15 %)
Typ. 0.5 % <2 % V
out
Dynamic load smoothing
(I
out
: 50/100/50 %)
Typ. 5.0 % V
out
(0 to 100%) Typ. 4.0 % V
out
Load-step settling time
50 at 100 % < 10 ms (typ. 2 ms)
100 at 50 % < 10 ms (typ. 2 ms)
Protection and monitoring
Output overvoltage protection < 17.6 V < 35 V
Current limitation 9.9 A Typ. 22 A, overload capability 150% I
out rated
up to
5 s/min
Short-circuit protection Electronic shutdown,
automatic restart
Alternatively, constant current characteristic approx.
22 A or latching shutdown
Sustained short-circuit current rms
value
10 A Approx. 22 A
Overload/short-circuit indicator Yellow LED for "Overload",
red LED for "latching shutdown"
Safety
Primary/secondary isolation Yes, safety extra low output voltage V
out
according to
EN 60950-1
Yes, SELV output voltage V
out
according to
EN 60950-1 and EN 50178
Protection class Class I Class I
Leakage current < 3.5 mA (typ. 1 mA) < 3.5 mA
Safety test Yes; CB Scheme in preparation Yes
CE mark Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1) in
preparation; cURus (UL 60950-1, CSA C22.2
No. 60950-1) in preparation
Available soon
Explosion protection
FM approval
Marine approval
Degree of protection (EN 60529) IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B
Supply harmonics limitation EN 61000-3-2 EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2
Operating data
Permitted ambient temperature -10 ... +70 C with natural convection -25 ... +60 C with natural convection
Transport/storage temperature
range
-25 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Mains input One screw-type terminal each for 0.3 ... 1.3 mm
2

solid/finely stranded
One screw-type terminal each for 0.2 ... 4 mm
2

solid/finely stranded
Output + 2 screw terminals for 0.3 ... 1.3 mm
2
2 screw terminals for 0.2 ... 4 mm
2
Output 2 screw terminals for 0.3 ... 1.3 mm
2
2 screw terminals for 0.2 ... 4 mm
2
Annunciation signals 2 screw terminals for 0.14 ... 1.5 mm
2
Dimensions (W x H x D) in mm 97 x 158 x 38 70 x 125 x 125
Weight, approx. 0.57 kg 1.2 kg
Installation Wall mounting Snaps onto DIN rail
EN 60715 357.5/15
Accessories
Unit labeling plates (3RT1 900-1SB20)
KT10_EN_gesamt.book Seite 11 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 15 V
13/12
Siemens KT 10.1 2012
13
Overview

Technical specifications
Product LOGO!Power LOGO!Power Special design
SITOP dual
Power supply, type 15 V/1.9 A 15 V/4 A 2 x 15 V/3.5 A
Order No. 6EP1 351-1SH03 6EP1 352-1SH03 6EP1 353-0AA00
The product families are
highlighted in the same color.
For an explanation of the product
families, see chapter 1, pages 1/8
through 1/12.
The power supplies of the LOGO!Power range are optimally matched to
the LOGO! logic modules in their functionality and design; with the wide-
range input 85 V to 264 V AC and option for installing in built-in miniature
distribution boards, they can be used universally in the low-end
performance range. They can also operate with DC 110 V to 300 V.
The industrial power supply with
two 15 V outputs that can be
switched in parallel and in series;
can be used, for example, to
supply electronic loads with 15 V.
Product LOGO!Power LOGO!Power Special design
SITOP dual
Input
1-phase AC or DC 1-phase AC or DC 1-phase AC
Rated voltage value V
in rated
100-240 V AC
Wide-range input
100-240 V AC
Wide-range input
120-230 V AC
Wide-range input
Voltage range AC 85 ... 264 V
DC 110 ... 300 V
AC 85 ... 264 V
DC 110 ... 300 V
93 ... 264 V
Overvoltage resistance 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms Surge voltage in accordance with
EN 61000-6-2 Table 4
Mains buffering at I
out rated
> 40 ms at V
in
= 187 V > 40 ms at V
in
= 187 V > 10/40 ms at V
in
= 120/187 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
0.63-0.33 A 1.24-0.68 A 1.9-1.15 A
Switch-on current limit (+25 C) < 25 A < 55 A < 30 A, typ. 3 ms
I
2
t < 0.8 A
2
s < 3 A
2
s < 3 A
2
s
Built-in incoming fuse Internal Internal T4 A/250 V (not accessible)
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
16 A or higher, characteristic B or
10 A or higher, characteristic C
16 A or higher, characteristic B or
10 A or higher, characteristic C
16 A or higher, characteristic B or
10 A or higher, characteristic C
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated
DC voltage
Rated voltage V
out rated
15 V DC 15 V DC 2 15 V DC
Total tolerance 3 % 3 % 2 %
Static line compensation Approx. 0.1 % Approx. 0.1 % ca. 0.2 %
Static load compensation Approx. 1.5 % Approx. 1.5 % ca. 0.2 %
Residual ripple < 200 mV
pp
(typ. 10 mV
pp
) < 200 mV
pp
(typ. 10 mV
pp
) < 50 mV
pp
(typ. 20 mV
pp
)
Spikes (bandwidth: 20 MHz) < 300 mV
pp
(typ. 30 mV
pp
) < 300 mV
pp
(typ. 70 mV
pp
) < 150 mV
pp

Adjustment range 10.5 ... 16.1 V 10.5 ... 16.1 V 14.5 ... 17 V
Status display Green LED for 15 V OK Green LED for 15 V OK Green LED for V
out
>10 V
(summation display)
Signaling
On/off behavior No overshoot of V
out

(soft start)
No overshoot of V
out

(soft start)
Overshoot of V
out
< 3 %
Startup delay /
voltage rise
< 0.5 s/typ. 15 ms < 0.5 s/typ. 15 ms < 1 s/
Rated current value I
out rated
1.9 A 4 A 2 3.5 A
Current range
Up to +60 C 0 ... 1.9 A (up to +55 C) 0 ... 4 A (up to +55 C) 2 0 ... 2.5 A
Derating 0 ... 1.3 A (up to +70 C) 0 ... 2.8 A (up to +70 C) 2 0 ... 3.5 A (up to +45 C)
Dynamic overcurrent on
Power-up on short-circuit
Short circuit during operation
Parallel switching for
enhanced performance
Yes, 2 units Yes, 2 units Yes, 2 units
NEW NEW
KT10_EN_gesamt.book Seite 12 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 15 V
13/13
Siemens KT 10.1 2012
13
Technical specifications (continued)
Product LOGO!Power LOGO!Power Special design
SITOP dual
Power supply, type 15 V/1.9 A 15 V/4 A 2 x 15 V/3.5 A
Order No. 6EP1 351-1SH03 6EP1 352-1SH03 6EP1 353-0AA00
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 81 % Approx. 85 % Approx. 80 %
Power loss at V
out rated
, I
out rated
Approx. 7 W Approx. 11 W Approx. 27 W
Closed-loop control
Dyn. mains compensation
(V
in

rated
15 %)
<0.2 % V
out
<0.2 % V
out
Dynamic load compensation
(I
out
: 10/90/10 %)
Typ. 2.8 % V
out
Typ. 3 % V
out
Load-step settling time
10 at 90 % Typ. 1 ms Typ. 1 ms
90 at 10 % Typ. 1 ms Typ. 1 ms
Protection and monitoring
Output overvoltage protection Yes, according to EN 60950
Current limitation
Typically 2.7 A Typically 5.7 A Limit point < 4.9 A;
switch-off point < 6 A
Short-circuit protection Constant current characteristic Constant current characteristic Electronic shutdown, automatic
restart
Sustained short-circuit current rms
value
< 3.6 A < 7 A
Overload/short-circuit indicator
Safety
Primary/secondary isolation Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, SELV output voltage V
out

according to EN 60950-1 and
EN 50178
Yes, safety extra low output
voltage V
out
according to
EN 60950-1
Protection class Class II (without protective
conductor)
Class II (without protective
conductor)
Class I
Leakage current < 3.5 mA
Safety test Yes; CB Scheme Yes; CB Scheme Yes
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cURus-Recognized (UL 60950,
CSA C22.2 No. 60950),
File E151273
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cURus-Recognized (UL 60950,
CSA C22.2 No. 60950),
File E151273
cULus-listed (UL 508, CSA C22.2
No. 142), File E179336
Explosion protection ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2. Group ABCD, T4

FM approval Class I, Div. 2. Group ABCD, T4 Class I, Div. 2. Group ABCD, T4

Marine approval GL GL

Degree of protection (EN 60529)


IP20 IP20
IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55011 Class A
Supply harmonics limitation Not applicable Not applicable
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Permitted ambient temperature -20 ... +70 C with natural
convection
-20 ... +70 C with natural
convection
0 ... +60 C with natural
convection, derated above +45 C
Transport/storage temperature
range
-40 ... +85 C - 40 ... +85 C -40 ... +70 C
Humidity class Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Climate class 3K3 according to
EN 60721, no condensation
Mechanics
Connections
Supply input L1, N, PE One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely
stranded
Output + 2 screw terminals for
0.5 to 2.5 mm
2
2 screw terminals for
0.5 to 2.5 mm
2
1 screw terminal each for
0.5 ... 2.5 mm
2
(P15_1, GND1,
GDN2)
Output - 2 screw terminals for
0.5 to 2.5 mm
2
2 screw terminals for
0.5 to 2.5 mm
2
2 screw terminals for
0.5 ... 2.5 mm
2
(P15_2)
Dimensions (W x H x D) in mm 54 90 55 72 90 55 75 125 125
Weight, approx. 0.17 kg 0.25 kg 0.75 kg
Installation Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
Snaps onto DIN rail EN 60715
35x7.5/15
KT10_EN_gesamt.book Seite 13 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 48 V
13/14
Siemens KT 10.1 2012
13
Overview

Technical specifications
Product SITOP modular
PSU300M
SITOP modular
Power supply, type 48 V/10 A 48 V/20 A
Order No. 6EP1 456-3BA00 6EP1 457-3BA00
The three-phase 48 V power supply for powerful
loads that are supplied with double the usual
24 V; with wide-range input; slim design; with 50 %
extra power for 5 s/min.
The modular 48 V power supply for powerful loads
that are supplied with double the usual 24 V; with
wide-range input and switchable output
characteristic; function expansion possible with add-
on module.
Product SITOP modular
PSU300M
SITOP modular
Input
3-phase AC 3-phase AC
Rated voltage value V
in rated
400-500 V 3 AC
Wide-range input
400 to 500 V 3 AC
Wide-range input
Voltage range 320 ... 575 V 320 ... 550 V (startup from V
in
> 340 V)
Overvoltage resistance 2.3 V
in

rated
, 1.3 ms 2.3 V
in

rated
, 1.3 ms
Mains buffering at I
out rated
> 15 ms at V
in
= 400 V
> 6 ms at V
in
= 400 V
Rated line frequency value; range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz
Rated current I
in rated
1.2-1.0 A 2.2 A (V
in
= 400 V)
Switch-on current limit (+25 C) < 18 A < 70 A
I
2
t < 0.8 A
2
s < 2.8 A
2
s
Built-in incoming fuse None None
Recommended miniature circuit
breaker (IEC 898) in the mains
power input
3-pole connected miniature circuit breaker 6 ... 16 A,
characteristic C or motor circuit breaker 3RV2011-
1DA10 (set to 3 A) or 3RV2711-1DD10 (UL 489)
3-pole connected miniature circuit breaker 10 ... 16 A,
characteristic C or motor circuit breaker 3RV2011-
1DA10 (set to 3 A) 3RV2711-1DD10 (UL 489)
Output
Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage V
out rated
48 V DC 48 V DC
Total tolerance 3 % 3 %
Static line compensation Approx. 0.1 % ca. 0.1 %
Static load compensation Approx. 0.2 % ca. 0.2 %
Residual ripple < 100 mV
pp
< 100 mV
pp
(typ. 10 mV
pp
)
Spikes (bandwidth: 20 MHz) < 200 mV
pp
< 200 mV
pp
(typ. 80 mV
pp
)
Adjustment range 42 ... 56 V (max. 480 W) 42 ... 56 V (max. 960 W)
Status display Green LED for 48 V OK Green LED for 48 V OK
Signaling Power good via relay contact (NO contact,
rating 60 V/0.3 A) for output voltage OK
Possible via signaling module
(6EP1 961-3BA10)
On/off behavior No overshoot of V
out

(soft start)
No overshoot of V
out

(soft start)
Startup delay /
voltage rise
< 2.5 s/< 500 ms (typ. 150 ms) < 2.5 s/typ. 20 ms
Rated current value I
out rated
10 A 20 A
Current range
Up to +60 C 0 ... 10 A 0 ... 20 A
Derating 0 ... 7 A (up to +70 C)
KT10_EN_gesamt.book Seite 14 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Output voltage 48 V
13/15
Siemens KT 10.1 2012
13
Technical specifications (continued)
Product SITOP modular
PSU300M
SITOP modular
Power supply, type 48 V/10 A 48 V/20 A
Order No. 6EP1 456-3BA00 6EP1 457-3BA00
Output (continued)
Dynamic overcurrent on
Power-up on short-circuit Constant current approx. 11 A Constant current approx. 23 A
Short circuit during operation Typ. 23 A for 25 ms Typ. 60 A for 25 ms
Parallel switching for
enhanced performance
Yes, 2 units (switchable characteristic) Yes, 2 units (switchable characteristic)
Efficiency
Efficiency at V
out rated
, I
out rated
Approx. 93 % Approx. 90 %
Power loss at V
out rated
, I
out rated
Approx. 36 W Approx. 106 W
Protection and monitoring
Output overvoltage protection Yes, according to EN 60950 Yes, according to EN 60950
Current limitation Typ. 11 A, overload capability 150% I
out rated
up to
5 s/min
Typically 23 A
Short-circuit protection Alternatively, constant current characteristic approx.
11 A or latching shutdown
Alternatively, constant current characteristic approx.
23 A or latching shutdown
Sustained short-circuit current rms
value
Approx. 11 A Approx. 23 A
Overload/short-circuit indicator LED yellow for "overload", LED red for "latching
shutdown"
LED yellow for "overload", LED red for "latching
shutdown"
Safety
Primary/secondary isolation Yes, SELV output voltage V
out
according to
EN 60950-1 and EN 50178
Yes, safety extra low output voltage V
out
according to
EN 60950-1
Protection class Class I Class I
Leakage current < 3.5 mA < 3.5 mA (typ. 0.68 mA)
Safety test Yes Yes
CE mark Yes Yes
UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2 No. 107.1), File
E197259
cULus-Listed (UL 508, CSA C22.2 No. 107.1), File
E197259; cCSAus (CSA C22.2 No. 60950, UL 60950)
Explosion protection ATEX (available soon)
Marine approval GL and ABS available soon
Degree of protection (EN 60529) IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55022 Class B
Supply harmonics limitation EN 61000-3-2 EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2
Operating data
Permitted ambient temperature -10 ... +70 C with natural convection 0 ... +60 C with natural convection
Transport/storage temperature
range
-40 ... +85 C -40 ... +85 C
Humidity class Climate class 3K3 according to EN 60721,
no condensation
Climate class 3K3 according to EN 60721,
no condensation
Mechanics
Connections
Supply input L1, L2. L3.PE One screw-type terminal each for
0.5 ... 2.5 mm
2
solid/finely stranded
One screw-type terminal each for
0.2 ... 4 mm
2
solid/finely stranded
Output + One screw terminal each for 0.2 ... 4 mm
2
2 screw terminals each for 0.33 ... 10 mm
2
Output - One screw terminal each for 0.2 ... 4 mm
2
2 screw terminals each for 0.33 ... 10 mm
2
Alarm signals 2 screw terminals for 0.14 ... 1.5 mm
2

Dimensions (W x H x D) in mm 70 x 125 x 125 240 125 125


Weight, approx. 1.2 kg 3.2 kg
Installation Snaps onto DIN rail EN 60715 357.5/15 Snaps onto DIN rail EN 60715 3515
Accessories
Device labeling plates (3RT1900-1SB20) Signaling module (6EP1961-3BA10)
KT10_EN_gesamt.book Seite 15 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Ordering data and additional information
13/16
Siemens KT 10.1 2012
13
Selection and ordering data
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
Special design, SITOP flexi
120/230 V AC DC 3-52 V 2-10 A 6EP1 353-2BA00
LOGO!Power
100-240 V AC 5 V DC 3 A 6EP1 311-1SH03
LOGO!Power
100-240 V AC 5 V DC 6.3 A 6EP1 311-1SH13
LOGO!Power
100-240 V AC 12 V DC 1.9 A 6EP1 321-1SH03
SITOP compact, PSU100C
100 - 230 V AC 12 V DC 2 A 6EP1 321-5BA00
Special design, SITOP DC/DC
24 V DC 12 V DC 2.5 A 6EP1 621-2BA00
Special design, PSU100D
(Planned delivery date:
December 2011)
100-240 V AC 12 V DC 3 A 6EP1 321-1LD00
LOGO!Power
100-240 V AC 12 V DC 4.5 A 6EP1 322-1SH03
NEW
NEW
NEW
NEW
NEW
NEW
KT10_EN_gesamt.book Seite 16 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP
Alternative voltages
Ordering data and additional information
13/17
Siemens KT 10.1 2012
13
Selection and ordering data (continued)
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros: www.siemens.com/sitop-cax
Operating instructions: www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product Input Output Order No. Price
Voltage V
in rated
Voltage V
out rated
Current
I
out rated
SITOP compact, PSU100C
100 - 230 V AC 12 V DC 6.5 A 6EP1 322-5BA10
Special design, PSU100D
(Planned delivery date:
December 2011)
100-240 V AC 12 V DC 8.3 A 6EP1 322-1LD00
Special design, PSU300B
(Planned delivery date:
December 2011)
400-500 V
3 AC
12 V DC 20 A 6EP1 424-3BA00
LOGO!Power
100-240 V AC 15 V DC 1.9 A 6EP1 351-1SH03
LOGO!Power
100-240 V AC 15 V DC 4 A 6EP1 352-1SH03
Special design, SITOP dual
120/230 V AC 2 15 V DC 2 3.5 A 6EP1 353-0AA00
SITOP modular, PSU300M
400-500 V 3 AC 48 V DC 10 A 6EP1 456-3BA00
SITOP modular
400-500 V 3 AC 48 V DC 20 A 6EP1 457-3BA00
NEW
NEW
NEW
NEW
NEW

KT10_EN_gesamt.book Seite 17 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SITOP

Notes
13/18
Siemens KT 10.1 2012
13
KT10_EN_gesamt.book Seite 18 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
14
14/2 Mounting bracket
14/2 Mounting adapter for DIN rail
14/2 Connector for devices in IP65 and IP67
14/2 Device labeling plates
14/2 Ordering data and additional information
Accessories
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Accessories
Mounting bracket, mounting adapter,
connectors, device labeling plates
14/2
Siemens KT 10.1 2012
14
Mounting bracket
Mounting adapter for DIN rail
The 24 V/2 A (6ES7 305-1BA80-0AA0) and 24 V/5 A (6ES7 307-
1EA80-0AA0) single-phase power supplies are special mechanical
versions for SIMATIC S7-300 which can be snapped on
S7 mounting rails. An adapter (6SE7 390-6BA00-0AA0) for
mounting on the DIN rail EN 60715 3515 is available separately
as an accessory.
The 24 V/ 2 A (6ES7 307-1BA01-0AA0), 24 V/5 A (6ES7-307-
1EA01-0AA0) and 10 A (6ES7-307-1KA02-0AA0) power sup-
plies are variants for SIMATIC S7-300 and can be snapped on
the S7 mounting rail.
A mounting adapter (6EP1 971-1BA00) for installation on the DIN
rail EN 60715 3515/7.5 is separately available as an accessory.
Connector for devices in IP65 and IP67 degree of protection
For the SITOP PSU300P power supply (6EP1 433-2CA00) in
IP67 degree of protection, a power connection plug
(3RK1 911-2BE50) is available as a spare part.
For the maintenance-free DC UPS modules SITOP UPS500P
(6EP1 933-2NC01, 6EP1 933-2NC11) in IP65 degree of protection,
a connector kit (6EP1 975-2ES00) for input and output with
pre-assembled 2 m USB cable is available as spare part.
Device labeling plates
Device labeling plates (delivered blank, sized at 20 mm x 7 mm,
pastel turquoise) are available to label power supplies. The or-
der number is 3RT1 900-1SB20. The package unit comprises
340 labels on frames, 20 labels per frame. For usability, refer to
"Accessories" in the technical data of the respective power sup-
plies.
Ordering data
Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
Product 90 mounting bracket
Mounting bracket For a depth of 320 mm
Order No. 6EP1 971-2BA00
The combination of a SITOP power supply and a 90 mounting bracket
results in a minimum surface area requirement on the rear panel of the
control cabinet (the width of the power supply becomes the depth, and
the depth becomes the width). The mounting bracket is suitable for
control cabinets with a depth of 320 mm or more.
Technical specifications of mounting bracket
Dimensions (W H D) in mm 100 150 320
Sheet metal thickness 1.5 mm
Mounting rail, attached DIN rail EN 60715 3515
Weight, approx. 0.9 kg
Installation Can be screwed onto a flat
surface (keyhole mounting for hooking
onto M6 screws, drill hole distance
90 mm height, 50 mm side distance)
Accessories, included 4 M6 combi screws
Suitable, for example, for SITOP 24 V/20 A
(6EP1336-3BA00, 6EP1436-3BA00)
SITOP 24 V/40 A
(6EP1337-3BA00, 6EP1437-3BA00)
SITOP 48 V/20 A (6EP1457-3BA00)
Product Description Order No. Price
90 mounting bracket
Suitable for cabinets that are at least 320 mm deep 6EP1 971-2BA00
Mounting adapter
For DIN rail EN 60715 35x7.5/15 6EP1 971-1BA00
For DIN rail EN 60715 35x15 6ES7 390-6BA00-0AA0
Power connection plug
For SITOP PSU300P 3RK1 911-2BE50
Connector set
For UPS500P 6EP1 975-2ES00
Device labeling plates
Pastel turquoise, 20 x 7 mm; Package containing 340 pcs. 3RT1 900-1SB20
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
15
15/2 Overview
15/2 Technical specfications
15/3 Selection and ordering data
SIPLUS power supplies
Export regulations AL and ECCN
see page 17/9
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SIPLUS power supplies
15/2
Siemens KT 10.1 2012
15
Overview
In harsh industrial environments you need products that exhibit
special properties, products that can cope with these conditions
and that are even more robust that the standard products.
SIPLUS extreme is our answer to these requirements.
SIPLUS extreme products are based on Siemens Industry stan-
dard power supplies SITOP, LOGO!Power and power supplies
for SIMATIC S7.
The SIPLUS versions possess the following characteristics:
Expanded ambient temperature range (e.g. -40 +70 C)
Conformal coating as a protection against extreme and diffi-
cult conditions and contact with substances
EN 50155:
Matches standard Electronic equipment used on rolling
stock (EN 50155, temperature T1, category)
Hard gold-plated contacts for improved contact-making, even
for low currents
Technical specifications
1)
ISA -S71.04 severity level GX: Long-term load:
SO
2
< 4.8 ppm; H
2
S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm;
HF < 0.12 ppm; NH < 49 ppm; O
3
< 0.1 ppm; NO
x
< 5.2 ppm
Limit value (max 30 min/d): SO
2
< 14.8 ppm;
H
2
S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm;
NH < 247 ppm; O
3
< 1.0 ppm; NO
x
< 10.4 ppm
2)
The supplied plug covers must remain in place over the unused inter-
face when operated in atmospheres containing corrosive gases!
3)
Ballast for operation with combustion engines
(Input DC: 10.5 ... 59 V, output DC: 20.4 ... 28.8 V).
Ambient conditions (includes contact with substances)
Relative humidity 5 100 %, condensation permissible
Biologically active
substances
Conformity with EN 60721-3-3,
class 3B2: mold, fungus, spores (fauna is
excluded)
Chemically active
substances
Conformity with EN 60721-3-3,
class 3C4 incl. salt mist and
ISA -S71.04 severity level G1; G2; G3;
GX
1)2)
Mechanically active
substances
Conformity with EN 60721-3-3,
class 3S4, incl. sand, dust
2)

Air pressure (depending on
the highest positive
temperature range
specified)
1080...795 hPa (-1000 +2000 m)
see ambient temperature range
795 ... 658 hPa (+2000 ... +3500 m)
derating 10 K
658 540 hPa (+3500 +5000 m)
derating 20 K
Other technical data are the same as for the corresponding
standard products
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SIPLUS power supplies
15/3
Siemens KT 10.1 2012
15
Selection and ordering data
Product SIPLUS version Standard product Order No. Price
1-phase
SIPLUS S7-200 PS203 3.5 A
-25 +70 C
protected against contact
with substances
6EP1 332-1SH31
see page 4/2
6AG1 203-1SH31-2AA0
SIPLUS S7-300 PS 305 2 A
-25 +70 C
protected against contact
with substances, EN 50155
6ES7 305-1BA80-0AA0
see page 2/3
6AG1 305-1BA80-2AA0
SIPLUS PS 24 0.375 A
protected against contact
with substances
6EP1 731-2BA00
see page 2/2
6AG1 931-2BA00-3AA0
SIPLUS S7-1200 PM 1207
-25 +70 C
protected against contact
with substances
6EP1 332-1SH71
see page 3/3
6AG1 332-1SH71-7AA0
protected against contact
with substances
6EP1 332-1SH71
see page 3/3
6AG1 332-1SH71-4AA0
SIPLUS LOGO! upmiter 1.25 A
3)

-25 +70 C
protected against contact
with substances
6AG1 053-1AA00-2AA0
SIPLUS S7-200 upmiter 2.5 A
3)

-25 +70 C
protected against contact
with substances
6AG1 203-1AA00-2AA0
SIPLUS S7-300 upmiter 2.5 A
3)

-25 +60 C
protected against contact
with substances
6AG1 305-1AA00-2AA0
1-phase and 2-phase
SIPLUS PS modular 5 A
-40 +70 C
protected against contact
with substances
6EP1 333-3BA00
see page 5/2
6AG1 933-3BA00-2AA0
SIPLUS S7-300 PS 307 5 A Outdoor
-25 +70 C
protected against contact
with substances, EN 50155
6ES7 307-1EA80-0AA0
see page 5/3
6AG1 307-1EA80-2AA0
SIPLUS PS modular 10 A
-40 +60 C
protected against contact
with substances
6EP1 334-3BA00
see page 7/2
6AG1 334-3BA00-2AA0
protected against contact
with substances
6EP1 334-3BA00
see page 7/2
6AG1 334-3BA00-4AA0
SIPLUS PS smart 10 A
protected against contact
with substances
6EP1 334-2BA01
see page 7/2
6AG1 334-2BA01-4AA0
SIPLUS S7-300 PS 307 10 A
-25 +70 C
protected against contact
with substances
6ES7 307-1KA02-0AA0
see page 7/3
6AG1 307-1KA02-7AA0
SIPLUS PS modular 20 A
-40 +70 C
protected against contact
with substances
6EP1 336-3BA00
see page 8/3
6AG1 336-3BA00-7AA0
protected against contact
with substances
6EP1 336-3BA00
see page 8/3
6AG1 936-3BA00-4AA0
SIPLUS PS modular 40 A
protected against contact
with substances
6EP1 337-3BA00
see page 8/3
6AG1 337-3BA00-4AA0
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
SIPLUS power supplies
15/4
Siemens KT 10.1 2012
15
Ordering data (continued)
Product SIPLUS version Standard product Order No. Price
3-phase
SIPLUS PS modular 5 A
-40 +70 C
protected against contact
with substances
6EP1 333-3BA00
see page 9/2
6AG1 933-3BA00-2AA0
SIPLUS PS modular 10 A
-40 +60 C
protected against contact
with substances
6EP1 334-3BA00
see page 9/2
6AG1 334-3BA00-2AA0
SIPLUS PS modular 20 A
-40 +70 C
protected against contact
with substances
6EP1 436-3BA00
see page 9/3
6AG1 436-3BA00-7AA0
SIPLUS PSU300M 40 A
-25 +70 C
protected against contact
with substances
6EP1 437-3BA10
see page 10/2
6AG1 437-3BA10-7AA0
SIPLUS PS modular 3AC 40 A
protected against contact
with substances
6EP1 437-3BA00
see page 10/3
6AG1 437-3BA00-4AA0
Product SIPLUS version Standard product Order No. Price
Expansion modules
SIPLUS PS signaling module
Contacts hard gold plated
protected against contact
with substances
6EP1 961-3BA10
see page 11/2
6AG1 961-3BA10-6AA0
SIPLUS PS signaling module
-25 +70 C
protected against contact
with substances
6EP1 961-3BA10
see page 11/2
6AG1 961-3BA10-7AA0
SIPLUS PSE202U redundancy
module
-40 +70 C
protected against contact
with substances
6EP1 961-3BA21
see page 11/2
6AG1 961-3BA21-7AX0
protected against contact
with substances
6EP1 961-3BA21
see page 11/2
6AG1 961-3BA21-4AX0
SIPLUS PS buffer module
-25 +70 C
protected against contact
with substances
6EP1 961-3BA01
see page 11/2
6AG1 961-3BA01-7AA0
Product SIPLUS version Standard product Order No. Price
Uninterruptible power supply DC UPS
SIPLUS PS DC UPS module 15 A
-25 +60 C
protected against contact
with substances
6EP1 931-2EC21
see page 12/14
6AG1 931-2EC21-2AA0
SIPLUS PS DC UPS module 40 A
-25 +70 C
protected against contact
with substances
6EP1 931-2FC21
see page 12/14
6AG1 931-2FC21-7AA0
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
SITOP
SITOP
V1
V2
Load
G_KT01_DE_00017
+
-
+
-
16
16/2 Power supplies in general
16/5 Supply system data, line-side connection
16/9 Possible system disturbances and their
causes
16/10 Mounting, mounting areas and installa-
tion options
16/11 Planning assistance
16/13 Parallel connections for redundant
operation and for performance
enhancement
16/15 Series connection to increase voltage
16/16 Battery charging
16/16 Fusing of the 24 V DC output circuit,
selectivity
16/20 Important standards and approvals
Technical information and
configuring notes
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Power supplies in general
16/2
Siemens KT 10.1 2012
16
Power supplies
In plant building or mechanical equipment manufacture, or in any
other situations in which electrical controls are used, a safe and
reliable power supply is needed to supply the process with
power.
The functional reliability of electronic controls and therefore the
reliable operation of automated plants is extremely closely linked
to the resistance of the load power supply to failure. Final control
elements as well as input and output modules will only respond
to command signals if the power supply is operating reliably.
In addition to requirements such as safety, particular demands
are placed on the electromagnetic compatibility (EMC) of the
power supply with reference to the tolerance range of the output
voltage as well as its ripple.
Important factors that determine problem-free implementation
are, in particular:
An input current with a low harmonic content
Low emitted interference
Adequate immunity (noise immunity) to interference
Selected interference phenomena
General notes on DC power supplies
The DC power supply is a static device with one or more inputs
and one or more outputs that converts a system of AC voltage
and AC current and/or DC voltage and DC current to a system
with different values of DC voltage and DC current by means of
electromagnetic induction for the purpose of transmitting
electrical energy.
The type of construction of a DC power supply is primarily
decided by its intended use.
Non-stabilized DC power supplies
The AC mains voltage is transformed using 50 Hz/60 Hz safety
transformers to a protective extra-low voltage and smoothed
with down-circuit rectification and capacitor filtering.
In the case of non-stabilized DC power supplies, the DC output
voltage is not stabilized at a specific value, but the value is
varied in accordance with the variation in (mains) input voltage
and the loading.
The ripple is in the Volt range and is dependent on the loading.
The value for the ripple is usually specified as a percentage of
the DC output voltage level. Non-stabilized DC power supplies
are characterized by their rugged, uncomplicated design that is
limited to the important factors and focused on a long service
life.
Block diagram of a non-stabilized power supply
Stabilized DC power supplies
Stabilized DC power supplies have electronic control circuits
that maintain the DC voltage at the output at a specific value with
as little variation as possible. Effects such as variation in input
voltage or changes in load at the output are electrically
compensated in the specified function area.
The ripple in the output voltage for stabilized DC power supplies
lies in the millivolt range and is mainly dependent on the loading
at the outputs.
Stabilized DC power supplies can be implemented on different
functional principles. The most common types of circuit are:
Linear stabilized power supplies
Magnetic voltage stabilizers
Secondary pulsed switched-mode power supplies
Primary pulsed switched-mode power supplies
The most suitable principle for a particular application case will
depend mainly on the application. The objective is to generate a
DC voltage to supply the specific load as inexpensively and as
accurately as possible.
EMC Interference phenomena
Emission (emitted interference) Interference caused by
television and radio reception
Interference coupling on data
lines or power supply cables
Noise immunity (immunity to
interference)
Faults on the power cable due to
switching non-resistive loads
such as motors or contactors
Static discharge due to lightning
strikes
Electrostatic discharge through
the human body
Conducted noise induced by
radio frequencies
50 Hz
~
+
Line isolation Rectification Filtering
V
out
G_KT01_EN_00067
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Power supplies in general
16/3
Siemens KT 10.1 2012
16
Stabilized DC power supplies (continued)
Linear stabilized power supplies
Block diagram: Transformer with in-phase regulation
The transformer with in-phase regulation operates according to
a conventional principle. The supply is provided from an AC
supply system (one, two or three conductor supply).
A transformer is used to adapt it to form the required secondary
voltage.
The rectified and filtered secondary voltage is converted to a
stabilized voltage at the output in a regulation section. The
regulation section comprises a final control element and a
control amplifier. The difference between the stabilized output
voltage and the non-stabilized voltage at the filter capacitor is
converted into a thermal loss in the final control element. The
final control element functions in this case like a rapidly
changeable ohmic impedance. The thermal loss that arises in
each case is the product of output current and voltage drop over
the final control element.
This system is extremely adaptable. Even without further
modifications, several output voltages are possible. In the case
of multiple outputs, the individual secondary circuits are usually
generated from separate secondary windings of the input
transformer. Some applications can only be resolved in
accordance with this circuit principle. Especially when highly
accurate regulation, minimal residual ripple and fast
compensation times are required.
The efficiency is, however, poor and the weight and volume are
considerable. The transformer with in-phase regulation is
therefore only an economical alternative at low power ratings.
Advantages:
Simple, well-proven circuit principle
Good to excellent control characteristics
Fast compensation time
Disadvantages:
Relatively high weight and large volume due to the
50 Hz transformer
Poor efficiency, heat dissipation problems
Low storage time
Magnetic stabilizer
Block diagram: Magnetic stabilizer
The complete transformer comprises two components. The
"ferro resonator" and a series-connected auxiliary regulator. The
input winding and the resonance winding of the magnetic
stabilizer are decoupled to a large extent by means of the air
gap. The magnetic stabilizer supplies a well-stabilized AC
voltage. This is rectified and filtered. The transformer itself is
operated in the saturation range.
The ferro resonator frequently has a transformer with in-phase
regulation connected downstream to improve the control
accuracy. Secondary pulsed switched-mode regulators are
frequently also connected to the output.
The magnetic stabilizer technique is reliable and rugged but is
also large-volume, heavy and relatively
expensive.
Advantages:
Good to excellent control characteristics in combination with
series-connected linear regulators
Significantly better efficiency than a transformer with in-phase
regulation alone
Disadvantages:
The ferro resonator is frequency dependent
The power supplies are large and heavy due to the
magnetic components
Secondary pulsed switched-mode power supplies:
Block diagram: Secondary pulsed switched-mode power supply
Isolation from the supply system is implemented in this case with
a 50 Hz transformer. Following rectification and filtering, the
energy is switched at the output by means of pulsing through a
switching transistor in the filtering and storage circuit. Thanks to
the transformer at the input that acts as an excellent filter, the
mains pollution is low.
The efficiency of this circuit is extremely high.
This concept offers many advantages for power supplies with
numerous different output voltages.
To protect the connected loads, however, care must be taken; in
the event of the switching transistor breaking down, the full, non-
stabilized DC voltage of the filter capacitor will be applied to the
output. However, this danger also exists in the case of linear
stabilized power supplies.
Advantages:
Simple design and high efficiency
Multiple outputs, also galvanically isolated from one another,
are easily implemented by means of several secondary
windings
Fewer problems with interference than with primary pulsed
switched-mode power supplies
Disadvantages:
The 50 Hz transformer makes the power supplies relatively
large and heavy
The output ripple (spikes) correspond to those of a primary
pulsed switched-mode power supply
Rectifier Filtering
Vout
Unstabilized
mains
Stabilized
Load
Transformer
G_KT01_EN_00177
Actuator
Ferroresonator
in case of
readjustment
V

out
stabi-
lized
Stabilized output
voltage
Unsta-
bilized
mains
G_KT01_EN_00178
Load
Secundary
switched-mode
regulator
Switching
transistor
Transformer
Filtering
Retification
Unstabilized
mains
V
out
Load
stabilized
G_KT01_EN_00179
Control
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Power supplies in general
16/4
Siemens KT 10.1 2012
16
Stabilized DC power supplies (continued)
Primary pulsed switched-mode power supplies:
The term SMPS (Switch Mode Power Supply) or primary
switched-mode regulator is often used in the literature.
Block diagram: Single-ended forward converter
The primary switched-mode regulators are available in many
different circuit versions. The most important basic circuits are
single-ended forward converters, flyback converters, half-
bridge converters, full-bridge converters, push-pull converters
and resonance converters.
The general principle of operation of the primary switched-mode
regulator is shown in the block diagram of the single-ended
forward converter:
The non-stabilized supply voltage is first rectified and filtered.
The capacitance of the capacitor in the DC link determines the
storage time of the power supply on failure of the input voltage.
The voltage at the DC link is approximately 320 V DC for a 230 V
supply. A single-ended converter is then supplied with this DC
voltage and transfers the primary energy through a transformer
to the secondary side with the help of a pulse width regulator at
a high switching frequency. The switching transistor has low
power losses when functioning as a switch, so that the power
balance lies between > 70 % and 90 % depending on the output
voltage and current.
The volume of the transformer is small in comparison with a 50
Hz transformer due to the high switching frequency because the
transformer size, taking into account the higher switching
frequency, is smaller. Using modern semiconductors, clock
frequencies of 100 kHz and above can be achieved. However,
switching losses increase at excessively high clock frequencies
so that in each case a compromise has to be made between
high efficiency and the largest possible clock frequency. In most
applications, the clock frequencies lie between approximately
20 kHz and 250 kHz depending on the output power.
The voltage from the secondary winding is rectified and filtered.
The system deviation at the output is fed back to the primary
circuit through an optocoupler. By controlling the pulse width
(conducting phase of the switching transistor in the primary
circuit), the necessary energy is transferred to the secondary
circuit and the output voltage is regulated. During the non-
conducting phase of the switching transistor, the transformer is
demagnetized through an auxiliary winding. Exactly
the same amount of energy is transferred as is removed at the
output. The maximum pulse width for the pulse duty factor for
these circuits is < 50 %.
Advantages:
Small magnetic components (transformer, storage reactor,
filter) thanks to the high operating frequency
High efficiency thanks to pulse width regulation
Compact equipment units
Forced-air cooling is not necessary up to the kW range
High storage times are possible in case of power failure by
increasing the capacitance in the DC link
Large input voltage range possible
Disadvantages:
High circuit costs, many active components
High costs for interference suppression
The mechanical design must be in accordance with HF
criteria
Primary switched-mode power supplies have taken over from
the other switching modes in recent years. This is due, in
particular, to their compact size, minimal weight, high efficiency
and excellent price/performance ratio.
Summary
The most important characteristics of the circuit types described
above are summarized in the following table:
Comparison criteria for basic circuit variants
Single-ended-forward
V out
stabilized
Load
Control
Unstabilized
mains
G_KT01_EN_00180
Comparison
criteria
Connection types
Primary
switched-
mode
Secondary
switched-
mode
Transformer
with
in-phase
regulation
Magnetic
stabilizer
Input voltage
range
Very large Medium Very small Large
Regulation
speed
Medium Medium Very fast Slow
Storage time
after power
failure
Very long Long Very short Long
Residual
ripple
Medium Medium Very low Medium
Power loss Very small Small Large Very small
Frame size Very small Medium Very large Large
Weight Very light Medium Heavy Very heavy
Interference
suppression
overhead
Very large Medium Low Medium
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Supply system data, line-side connection
16/5
Siemens KT 10.1 2012
16
Supply system data
When dimensioning and selecting plant components, the supply
systems data, supply system conditions and operating modes
must be taken into account for these components.
The most important data for a supply system include the rated
voltage and rated frequency. These data for the supply system
are designated as rated values in accordance with international
agreements.
Rated voltages and rated frequencies
Since May 1987, the standard DIN IEC 60038 "IEC rated
voltages" has been applicable in the Federal Republic of
Germany.
The international standard IEC 60038, Edition 6, 1983, "IEC
standard voltages" was included unmodified in this standard.
The IEC 60038 standard is the result of an international
agreement to reduce the diverse rated voltage values that are in
use for electrical supply networks and traction power supplies,
load installations and equipment.
Conversion of low-voltage systems
In the low-voltage range, it is emphasized in IEC 60038 that the
220 V/380 V and 240 V/415 V values for three-phase electricity
supplies have been replaced by a single internationally
standardized value of 230 V/400 V.
The tolerances for the rated voltages of the supply systems that
were specified for the transition period up to 2003 were intended
to ensure that equipment rated for the previous voltages could
be operated safely until the end of its service life.

Conversion of low-voltage systems
The IEC recommendations have been implemented as national
regulations in the most important countries, as far as the
conditions in the
country allow.
International supply voltages and frequencies in low-voltage systems

1)
Industry only
2)
No further expansion
Year Rated voltage Tolerance range
Up to 1987 220 V/380 V 10 % to +10 %
1988 to 2003 230 V/400 V 10 % to + 6 %
Since 2003 230 V/400 V 10 % to +10 %
Country Supply voltage
Western Europe:
Belgium 50 Hz 230/400 127-220 V
Denmark 50 Hz 230/400 V
Germany 50 Hz 230/400 V
Finland 50 Hz 230/400-500
1)
660
1)
V
France 50 Hz 127/220 230/400 500
1)
380/660
1)
525/910
1)
V
Greece 50 Hz 230/400 127/220
2)
V
Great Britain 50 Hz (230/400 V)
Ireland 50 Hz 230/400 V
Iceland 50 Hz 127/220
2)
230/400 V
Italy 50 Hz 127/220 230/400 V
Luxembourg 50 Hz 230/400 V
The Netherlands 50 Hz 230/400 660
1)
V
Northern Ireland 50 Hz 230/400 Belfast 220/380 V
Norway 50 Hz 230-230/400-500
1)
690
1)
V
Austria 50 Hz 230/400 500
1)
690
1)
V
Portugal 50 Hz 230/400 V
Sweden 50 Hz 230/400 V
Switzerland 50 Hz 230/400 500
2)
V
Spain 50 Hz 230/400 V
Eastern Europe:
Albania 50 Hz 230/400 V
Bulgaria 50 Hz 230/400 V
Russian Federation 50 Hz 230/400 690
1)
V
Croatia 50 Hz 230/400 V
Poland 50 Hz 230/400 V
Romania 50 Hz 230/400 V
Serbia 50 Hz 230/400 V
Slovakia 50 Hz 230/400 500
1)
690
1)
V
Slovenia 50 Hz 230/400 V
Czech Republic 50 Hz 230/400 500
1)
690
1)
V
Hungary 50 Hz 230/400 V
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Supply system data, line-side connection
16/6
Siemens KT 10.1 2012
16
International supply voltages and frequencies in low-voltage systems (continued)

1)
Industry only
2)
No further expansion
Country Supply voltage
Middle East:
Afghanistan 50 Hz 220/380 V
Bahrain 50 Hz 230/400 V
Cyprus 50 Hz 240/415 V
Iraq 50 Hz 220/380 V
Israel 50 Hz 230/400 V
Jordan 50 Hz 220/380 V
Kuwait 50 Hz 240/415 V
Lebanon 50 Hz 110/190 220/380 V
Oman 50 Hz 220/380 240/415 V
Qatar 50 Hz 240/415 V
Saudi Arabia 60 Hz 127/220 220/380 480
1)
V
(220/380 240/415 V 50 Hz: a few remaining areas only)
Syria 50 Hz 115/200 220/380 400
1)
V
Turkey 50 Hz 220/380 V (parts of Istanbul: 110/190 V)
United Arab Emirates
(Abu Dhabi; Ajman; Dubai; Fujairah;
Ras al Khaymah; Sharjah; Um al Qaywayn)
50 Hz 220/380 240/415 V
Yemen (North) 50 Hz 220/380 V
Yemen (South) 50 Hz 230/400 V
Far East:
Bangladesh 50 Hz 230/400 V
Burma 50 Hz 230/400 V
People's Republic of China 50 Hz 127/220 220/380 V (in mining: 1140 V)
Hong Kong 50 Hz 200/346 V
India 50 Hz 220/380 230/400 240/415 V
Indonesia 50 Hz 127/220 220/380 400
1)
V
Japan 50 Hz 100/200 400
1)
V
South Honshu, Shikoku, Kyushu, Hokkaido, North Honshu 60 Hz 110/220 440
1)
V
Cambodia 50 Hz 120/208 V Phnom Penh 220/238 V
Korea (North) 60 Hz 220/380 V
Korea (South) 60 Hz 100/200
2)
220/380 440
1)
V
Malaysia 50 Hz 240/415 V
People's Republic of Mongolia 50 Hz 220/380 V
Pakistan 50 Hz 230/400 V
Philippines 60 Hz 110/220 440 V
Singapore 50 Hz 240/415 V
Sri Lanka 50 Hz 230/400 V
Taiwan 60 Hz 110/220 220 440 V
Thailand 50 Hz 220/380 V
Vietnam 50 Hz 220/380 V
North America:
Canada 60 Hz 600 120/240 460 575 V
USA 60 Hz 120/208 120/240 277/480 600
1)
V
Central America:
Bahamas 60 Hz 115/200 120/208 V
Barbados 50 Hz 110/190 120/208 V
Belize 60 Hz 110/220 220/440 V
Costa Rica 60 Hz 120/208
2)
120/240 127/220 254/440
2)
227/480
1)
V
Dominican Republic 60 Hz 120/208 120/240 480
1)
V
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Supply system data, line-side connection
16/7
Siemens KT 10.1 2012
16
International supply voltages and frequencies in low-voltage systems (continued)

1)
Industry only
2)
No further expansion
Country Supply voltage
Central America (continued):
Guatemala 60 Hz 120/208 120/240 127/220 277/480
1)
480
1)
550
1)
V
Haiti 50 Hz 220/380 V (Jacmel), 60 Hz 110/220 V
Honduras 60 Hz 110/220 127/220 277/480 V
Jamaica 50 Hz 110/220 440
1)
V
Cuba 60 Hz 120/240 220/380 277/480
1)
440
1)
V
Mexico 60 Hz 127/220 440
1)
V
Nicaragua 60 Hz 110/220 120/240 127/220 220/440 254/40
1)
V
Panama 60 Hz 120/208
1)
120/240 254/440
1)
277/480
1)
V
Puerto Rico 60 Hz 120/208 480 V
El Salvador 60 Hz 110/220 120/208 127/220 220/440 240/480
1)
254/440
1)
V
Trinidad 60 Hz 110/220 120/240 230/400 V
South America:
Argentina 50 Hz 220/380 V
Bolivia 60 Hz 220/380 480 V, 50 Hz 110/220 220/380 V (exception)
Brazil 60 Hz 110/220 220/440 127/220 220/380 V
Chile 50 Hz 220/380 V
Ecuador 60 Hz 120/208 127/220 V
Guyana 50 Hz 110/220 V (Georgetown), 60 Hz 110/220 240/480 V
Columbia 60 Hz 110/220 150/260 440 V
Paraguay 60 Hz 220/380 220/440 V
Peru 60 Hz 220 220/380/440 V
Surinam 60 Hz 115/230 127/220 V
Uruguay 50 Hz 220 V
Venezuela 60 Hz 120/208 120/240 208/416 240/480 V
Africa:
Egypt 50 Hz 110/220 220/380 V
Ethiopia 50 Hz 220/380 V
Algeria 50 Hz 127/220 220/380 V
Angola 50 Hz 220/380 V
Benin 50 Hz 220/380 V
Ivory Coast 50 Hz 220/380 V
Gabon 50 Hz 220/380 V
Ghana 50 Hz 127/220 220/380 V
Guinea 50 Hz 220/380 V
Kenya 50 Hz 220/380 V
Cameroon 50 Hz 127/220 220/380 V
Congo 50 Hz 220/380 V
Liberia 60 Hz 120/208 120/240 V
Libya 50 Hz 127/220
2)
220/380 V
Madagascar 50 Hz 127/220 220/380 V
Malawi 50 Hz 220/380 V
Mali 50 Hz 220/380 V
Morocco 50 Hz 115/200 127/220 220/380 500
1)
V
Mauritius 50 Hz 240/415 V
Mozambique 50 Hz 220/380 V
Namibia 50 Hz 220/380 V
Niger 50 Hz 220/380 V
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Supply system data, line-side connection
16/8
Siemens KT 10.1 2012
16
International supply voltages and frequencies in low-voltage systems (continued)

Connection and fusing on the line side
All SITOP and LOGO!Power supplies are built-in devices.
Compliance with the pertinent country-specific regulations is
essential for installation and electrical connection of the devices.
During installation, protective gear and isolating gear must be
provided for activating the power supply.
Power supply units cause a current inrush immediately after
connection of the input voltage due to charging of the load
capacitor, however, it falls back to the rated input current level
after a few milliseconds. Aside from the internal impedances of
the power supply, the inrush current is dependent on the size of
the input voltage applied as well as the source impedance of the
supply network and the line impedance of the supply line. The
maximum inrush current for the power supplies is specified in
the applicable technical data.
It is important for dimensioning up-circuit protective devices.
Single-phase SITOP and LOGO!Power supplies are equipped
with internal device protection (fuses). For connection to the
supply system, only one protective device (fuse or MCB) must
be provided for line protection in accordance with the rated
current of the installed cable. The circuit-breakers
recommended in the data sheets and operating instructions
were selected such that even during the maximum inrush
current that can occur under worst-case conditions when
switching on the supply voltage, the circuit-breaker
will not trip. A two-pole connected miniature circuit-breaker is
required for the connection of certain device types.
Three-phase SITOP power supplies do not have internal device
protection. The up-circuit protective device (three-phase
coupled miniature circuit-breaker or motor protection switch)
protects the cables and devices. The protective devices
specified in the data sheets and operating instructions are
optimized to the characteristics of the relevant power supplies.
1)
Industry only
Country Supply voltage
Africa (continued):
Nigeria 50 Hz 220/415 V
Rwanda 50 Hz 220/380 V
Zambia 50 Hz 220/380 V 415 550
1)
V
Senegal 50 Hz 127/220 220/380 V
Sierra Leone 50 Hz 220/380 V
Somalia 50 Hz 220-220/440 V
Sudan 50 Hz 240/415 V
South Africa 50 Hz 220/380 500
1)
550/950
1)
V
Swaziland 50 Hz 220/380 V
Tanzania 50 Hz 230/400 V
Togo 50 Hz 127/220 220/380 V
Tunisia 50 Hz 115/200 220/380 V
Uganda 50 Hz 240/415 V
Zaire 50 Hz 220/380 V
Zimbabwe 50 Hz 220/380 V
KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Possible system disturbances and causes
16/9
Siemens KT 10.1 2012
16
Overview
The quality of the mains voltage has become a decisive factor in
the functioning, reliability, maintenance costs and service life of
highly sensitive electronic installations and devices (computers,
industrial controls, instrumentation, etc.).
Mains disturbances cause system failures and affect the
function of plants as well as electronic loads. They can also
result in total failure of the installation or equipment.
The most frequent types of disturbance are:
Long-term overvoltages
Long-term undervoltages
Interference pulses and transients
Voltage dips and surges
Electrical noise
Momentary network failure
Long-term network failure
Mains disturbances can be caused by a number of things, e.g.:
Switching operations in the supply system
Long cable paths in the supply system
Environmental influences such as thunderstorms
Mains overloads
Typical causes of mains disturbances generated in-house are:
Thyristor-controlled drives
Elevators, air-conditioning, photocopiers
Motors, reactive-power compensation systems
Electrical welding, large machines
Switching of lighting equipment
Disturbances in mains voltages can occur individually or in combination. Possible reasons for these disturbances and reactions can
include:

Mains disturbances and effects
The SITOP product family offers a range of possibilities for minimizing or preventing the risk of mains disturbances already during
the planning stage.
System disturbances Percentage of total
disturbance
Effect
Overvoltage
The supply voltage is exceeded for a long period by
more than +6 % (acc. to DIN IEC 60038)
approx. 15 % 20 % Can result in overheating and even thermal destruction of
individual components. Causes total failure.
Undervoltage
The supply voltage is reduced for a long period by
more than +10 % (acc. to DIN IEC 60038)
approx. 20 % 30 % Can result in undefined operating states of loads. Causes
data errors.
Interference pulses
Energy-rich pulses (e.g. 700 V/1 ms) and energy-poor
transients (e.g. 2500 V/20 s) result from switching
operations in the supply system
approx. 30 % 35 % Can result in undefined operating states of the loads and can
lead to the destruction of components.
Voltage dips and surges
The voltage level changes suddenly and in an
uncontrolled manner, e.g. due to changes in loading
and long cable routes
approx. 15 % 30 % Can result in undefined operating states and destruction of
components. Cause data errors.
Electrical noise
A mix of frequencies superimposed on the mains due
to bad grounding and/or strong HF emitters, such
as radio transmitters or thunderstorms
approx. 20 % 35 % Can result in undefined operating states of loads. Causes
data errors.
Voltage interruption
Short-term interruption of the supply voltage
(up to approx. 10 ms) due to short-circuiting in
neighboring supply systems or starting of large
electrical machines.
approx. 8 % 10 % Can result in undefined operating states of loads, especially
those with insufficient mains buffering. Causes data errors.
Voltage interruption
Long interruption of the supply voltage
(longer than approx. 10 ms)
approx. 2 % 5 % Can result in undefined operating states of loads, especially
those with insufficient mains buffering. Causes data errors.
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Installation instructions, mounting areas
and fixing options
16/10
Siemens KT 10.1 2012
16
Installation instructions
All SITOP and LOGO!Power supplies are built-in devices. They
must be mounted vertically so that the supply air can enter the
ventilation slots at the bottom of the devices and leave through
the upper part of the devices. If the units are not mounted
vertically (at your own risk), the
ambient temperature should not exceed +45 C and the load
current should not exceed approx. 50% of the rated current
value. The minimum distances specified in the relevant
operating instructions for the top, bottom and side of the devices
must be observed to ensure free air convection.
Mounting areas and fixing options

Power supply Order No. Required
mounting area
Mounting on a standard mounting rail
(DIN Rail) acc. to EN 60715
Wall
mounting
in mm (B H) 35 7.5 mm 35 15 mm
SITOP 24 V, 1-phase and 2-phase power supplies
24 V/0.375 A 6EP1731-2BA00 22.5 180 X X
24 V/0.6 A 6EP1331-5BA00 22.5 x 180 X X
24 V/1.3 A 6EP1331-5BA10 30 x 180 X X
24 V/1.3 A 6EP1331-1SH03 54 130 X X
24 V/2 A 6ES7307-1BA01-0AA0
3)
40 205
2) 2)
6ES7305-1BA80-0AA0
3)
80 225
1)
6EP1732-0AA00 80 235 X X
24 V/2.1 A 6EP1331-1LD00 58 (117) x 128 X
24 V/2.5 A 6EP1332-2BA10 33 225 X X
6EP1332-5BA00 45 180 X X
6EP1332-1SH43 72 130 X X
6EP1332-1SH71 70 140 X X X
6EP1332-1LB00 33 225 X X
6EP1232-1AA00 52 (110) 230 X X X
24 V/3.1 A 6EP1332-1LD00 58 (117) x 128 X
24 V/3.5 A 6EP1332-1SH31 160 280 X X X
24 V/3.7 A 6EP1332-2BA00 75 225 X X
24 V/4 A 6EP1332-5BA10 52.5 x 180 X X
6EP1332-1SH52 90 130 X X
6EP1232-1AA10 52 (110) 230 X X X
24 V/4.1 A 6EP1332-1LD10 58 (117) x 158 X
24 V/5 A 6EP1333-3BA00 70 225 X X
6EP1333-2BA01 50 225 X X
6EP1333-2AA01 50 225 X X
6ES7307-1EA01-0AA0
3)
60 205
2) 2)
6EP1333-1LB00 50 225 X X
6ES7307-1EA80-0AA0
3)
80 225
1)
6EP1333-1AL12 160 230 X X
24 V/6 A 6EP1233-1AA00 52 (110) 230 X X X
24 V/6.2 A 6EP1333-1LD00 58 (117) x 178 X
24 V/10 A 6EP1334-3BA00 90 225 X X
6EP1334-2BA01 70 225 X X
6EP1334-2AA01 70 225 X X
6ES7307-1KA02-0AA0
3)
80 205
2) 2)
6EP1334-1LB00 70 225 X X
6EP1334-1AL12 160 230 X X
24 V/12 A 6EP1234-1AA00 52 (110) 230 X X X
24 V/12.5 A 6EP1334-1LD00 61 (125) x 199 X
24 V/20 A 6EP1336-3BA10 90 225 X X
6EP1336-3BA00 160 225 X X
24 V/40 A 6EP1337-3BA00 240 225 X
KT10_EN_gesamt.book Seite 10 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Planning assistance
16/11
Siemens KT 10.1 2012
16
SITOP 24 V, 3-phase power supplies
24 V/8 A 6EP1433-2CA00
4)
Approx. 310 285 X
6ES7148-4PC00-0HA0
4)
Approx. 310 285 X
24 V/10 A 6EP1434-2BA10 90 225 X X
24 V/20 A 6EP1436-3BA10 70 225 X X
6EP1436-3BA00 160 225 X X
6EP1436-2BA10 90 225 X X
24 V/30 A 6EP1437-3BA20 150 x 225 X
24 V/40 A 6EP1437-3BA10 150 x 225 X
6EP1437-3BA00 240 225 X X
6EP1437-2BA20 150 x 225 X
SITOP 24 V, uninterruptible power supplies
SITOP UPS500S (2.5 kWs) 6EP1933-2EC41 120 225 X X
SITOP UPS500S (5 kWs) 6EP1933-2EC51 120 225 X X
SITOP UPS501S
Expansion module
6EP1935-5PG01 70 225 X X
SITOP UPS500P (5 kWs) 6EP1933-2NC01 500 178 X
SITOP UPS500P (10 kWs) 6EP1933-2NC11 570 178 X
DC UPS 6 A
(with serial/USB interface)
6EP1931-2DC21
(-2DC31/-2DC42)
50 225 X X
DC UPS 15 A
(with serial/USB interface)
6EP1931-2EC21
(-2EC31/-2EC42)
50 225 X X
DC UPS 40 A
(with USB interface)
6EP1931-2FC21
(-2FC42)
102 225 X X
SITOP 24 V, uninterruptible power supply, battery modules
Battery module 1.2 Ah 6EP1935-6MC01 116 126 X X X
Battery module 2.5 Ah 6EP1935-6MD31 285 171 X X X
Battery module 3.2 Ah 6EP1935-6MD11 210 171 X X X
Battery module 7 Ah 6EP1935-6ME21 206 188 X
Battery module 12 Ah 6EP1935-6MF01 273 138 X
SITOP 24 V, expansion modules
Signaling module 6EP1961-3BA10 26 225
Redundancy module 6EP1961-3BA21 70 225 X X
Buffer module 6EP1961-3BA01 70 225 X X
Selectivity module 6EP1961-2BA11/ -2BA21 72 180 X X
Diagnostics module 6EP1961-2BA00 72 190 X X
Switch-on current limiter 6EP1967-2AA00 22.5 180 X X
SITOP alternative voltages
3-52 V/120 W 6EP1353-2BA00 75 225 X X
5 V/3 A 6EP1311-1SH03 54 130 X X
5 V/6.3 A 6EP1311-1SH13 72 130 X X
12 V/1.9 A 6EP1321-1SH03 54 130 X X
12 V/2 A 6EP1321-5BA00 30 180 X X
12 V/2.5 A 6EP1621-2BA00 32.5 225 X X
12 V/3 A 6EP1321-1LD00 158 (117) x 98 X
12 V/4.5 A 6EP1322-1SH03 72 130 X X
12 V/6.5 A 6EP1322-5BA10 52.5 180 X X
12 V/8.3 A 6EP1322-1LD00 58 (117) x 158 X
12 V/20 A 6EP1424-3BA00 70 225 X X
15 V/1.9 A 6EP1351-1SH03 54 130 X X
15 V/4 A 6EP1352-1SH03 72 130 X X
2 15 V/3.5 A 6EP1353-0AA00 75 325 X X
48 V/10 A 6EP1456-3BA00 70 225 X X
Power supply Order No. Required
mounting area
Mounting on a standard mounting rail
(DIN Rail) acc. to EN 60715
Wall
mounting
in mm (B H) 35 7.5 mm 35 15 mm
KT10_EN_gesamt.book Seite 11 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Planning assistance
16/12
Siemens KT 10.1 2012
16
1)
With additional mounting adapter 6ES7390-6BA00-0AA0.
2)
With additional mounting adapter 6EP1971-1BA00.
3)
Installation on S7-rail.
4)
Installation on mounting rail ET 200pro.
Planning aids
As an aid for planning and construction, operating instructions
with mounting options, dimension drawings and principle
circuits with pin names in different file formats (also suitable for
CAD applications) are available for download on the Internet.
Further information can be found on the Internet at
https://www.siemens.de/sitop
48 V/20 A 6EP1457-3BA00 240 255 X
Power supply Order No. Required
mounting area
Mounting on a standard mounting rail
(DIN Rail) acc. to EN 60715
Wall
mounting
in mm (B H) 35 7.5 mm 35 15 mm
KT10_EN_gesamt.book Seite 12 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Parallel connection for redundant operation
and performance enhancement
16/13
Siemens KT 10.1 2012
16
Parallel connection for redundant operation
Two SITOP power supplies of the same type can be connected
in parallel through diodes for a redundant configuration. 100%
redundancy only exists for two power supplies when the total
load current is no higher than that which one power supply can
supply alone and when the supply for the primary side is also
implemented redundantly (i.e. a short-circuit on the primary
side will not trigger a shared fuse which would disconnect both
power supplies from the mains).

Parallel connection with decoupling diodes for redundant
operation is permitted for all SITOP power supplies. The diodes
V1 and V2 are used for decoupling. They must have a blocking
voltage of at least 40 V and it must be possible to load them with
a current equal to or greater than the maximum output current of
the respective SITOP power supply. For diode dimensioning,
see the following note "General information on selection of
diodes".
The ready-to-use expansion "SITOP modular redundancy
module" is available as a simple alternative to diode
dimensioning (Order No.: 6EP1961-3BA21, see Section 11) for
redundant connection of two power supplies.
General information on selection of diodes:
The diodes must be dimensioned for the maximum dynamic
overcurrent. This can be the dynamic overcurrent during power-
up in the short-circuit case, or the dynamic overcurrent during a
short-circuit in operation (the largest of the two values should be
taken from the relevant technical specifications).
To dissipate the significant power loss of the decoupling diodes
(sustained short-circuit current diode conductive-state
voltage), the diodes must be equipped with suitably
dimensioned heat sinks.
An additional safety margin is recommended, because the
output capacitor integral to the power supply generates an
additional peak current in the short-circuit case. This additional
current flows only for a few milliseconds so it is within the period
in which diodes are permitted to be loaded with a multiple of the
rated current (< 8.3 ms, known as the permissible surge current
for diodes) .
Parallel connection of two SITOP power supplies for redundant operation
Example
Two 1-phase SITOP modular power supplies with
10 A rated output current, (Order No.: 6EP1 334-3BA00)
are connected in parallel. The dynamic overcurrent in the event
of a short-circuit during operation is approximately 30 A for 25 ms.
The diodes should therefore have a loading capability of 40 A to
be safe, the common heat sink for both diodes must be
dimensioned for the maximum possible current of approximately 24
A (sustained short-circuit current rms value) diode conductive-
state voltage.
SITOP
L+
M
SITOP
L+
M
V1
V2
Load
G_KT01_EN_00017
KT10_EN_gesamt.book Seite 13 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Parallel connection for redundant operation
and performance enhancement
16/14
Siemens KT 10.1 2012
16
Parallel connection for performance enhancement
To enhance performance, identical types of most SITOP power
supplies can be connected in parallel galvanically (the same
principle as parallel connection for redundant operation, but
without decoupling diodes):
Advantage
The costs for mounting the diodes onto heat sinks and the not
insignificant power losses for the decoupling diodes (current
diode conducting-state voltage) are avoided.
The types permitted for direct galvanic parallel connection are
listed in the relevant technical specifications under "Output,
parallel connection for performance enhancement".
Prerequisite:
The output cables connected to terminals "+" and "" of every
power supply should be installed with an identical length and
cross-section (or the same impedance) to the common
external linking point.
The power supplies connected in parallel must be switched
simultaneously using a common switch in the mains supply
line (e.g. using the main switch available in control cabinets).
The output voltages of the power supplies must be measured
under no-load operation before they are connected in parallel
and are permitted to differ by up to 50 mV. This usually
corresponds to the factory default setting. If the output voltage
is changed in case of variable power supplies, the ""
terminals should first be connected and then the voltage
difference between the "+" output terminals measured under
no-load conditions before these are connected. The voltage
difference must not exceed 50 mV.
Note:
With a direct galvanic connection in parallel of more than two
SITOP power supplies, further circuit measures may be
necessary for short-circuit and overload protection!
Parallel connection for redundant operation and
performance enhancement
Almost 100% redundancy
Using the types permitted for direct galvanic parallel connection
(see the relevant technical specifications under "Output, parallel
connection for performance enhancement"), performance can
be increased without the need for decoupling diodes, and
simultaneously, redundancy of almost 100% can be
implemented by direct galvanic parallel connection of an
additional power supply of the same type to the power supplies
required. This means that at least one power supply is required
than is necessary for the sum of all load currents.
A decoupling diode is normally required for redundancy to
ensure that a power supply that has failed as a result of short-
circuiting of the outputs (especially as a result of short-circuiting
the output electrolytic capacitor) does not also short-circuit the
power supplies that remain intact. A redundancy of almost 100%
can be implemented with this type of circuit.
Example
A load current of up to 40 A is required and the power supplies
must operate on both 400 V and 500 V three-phase supplies
(without switch-over).
The three-phase type SITOP modular 20 A is suitable for this
(Order No.: 6EP1 436-3BA10). For load currents up to 40 A,
direct galvanic parallel connection of two SITOP modular power
20 supplies is necessary. By connecting another SITOP modular
20 in parallel, performance enhancement and redundancy are
implemented simultaneously (if one of the three power supplies
fails to supply an output voltage, the remaining two 20 A power
supplies are capable of supplying a total load current of 40 A).
Note:
With a direct galvanic connection in parallel of more than two
SITOP power supplies, further circuit measures may be
necessary for short-circuit and overload protection!
KT10_EN_gesamt.book Seite 14 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Series connection to increase the voltage
16/15
Siemens KT 10.1 2012
16
Series connection to increase the voltage
To generate a load voltage of e. g. 48 V DC, two 24 V SITOP
power supplies of the same type can be connected in series.
The SITOP outputs "+" and "" are isolated up to at least 60 V DC
against PE (creepage and clearances as well as radio
interference suppression capacitors on "+" and "" against PE),
so that with this type of series connection (see Figure), the
following points can be grounded:
"" of the lower power supply (results in +48 V DC against PE)
Midway "+"/ "" between both power supplies
(results in 24 VDC against PE)
"+" of the lower power supply (results in -48 V DC against PE)
Note:
If two devices are connected in parallel, it cannot be guaranteed
that the voltage will remain below the maximum permissible
SELV voltage of 60 V DC in the event of a fault.
The purpose of diodes V1 and V2 is to protect the electrolytic
output capacitor integrated in the power supply against reverse
voltages > 1 V. As a result of the not absolutely simultaneous
power-up (even when a common mains switch is used for
switching on, differences of a few tens of milliseconds can occur
between the various startup-up delays), the power supply which
starts up more quickly supplies current from output "" of the
slower power supply whose output electrolytic capacitor is then
theoretically impermissibly discharged.
The internal LC filter causes the internal rectifier diode on the
secondary side of the slower-starting power supply to accept
this current a few milliseconds later; this means that the external
diode connected with its anode to "" and cathode to "+" is
essential on each power supply. These diodes are, however,
only loaded dynamically, so that the 8.3 ms surge current
loading capability (specified in the data sheets for suitable
diodes) can be used as a basis for dimensioning and it is not
usually necessary to cool the diodes using heat sinks.
1)
We do not accept any liability for this diode recommendation.
Series connection of two SITOP power units to double the voltage
Example:
Two single-phase SITOP modular power supplies with 10 A rated
output current (Order No.: 6EP1 334-1AL12) should be
connected in series for increasing the voltage. They supply
approximately 35 A dynamically for 700 ms on power-up in the
short-circuit case or also, for example, with loads with a high-
capacity input capacitor that momentarily act as a short-circuit
at the start.
Suitable diodes for V1 and V2 are, for example, of Type SB 340
1)

(Schottky diode in axially wired enclosure
DO-201AD with approximately 5.3 mm diameter and
approximately 9.5 mm length of body).
40 V are permissible as the blocking voltage, and the stationary
direct current load capacity I
F AV
is 3 A. The dynamic surge
current loading capacity I
F SM
important in this case is sufficient
for the selected SITOP power supply at more than 100 A for 8.3
ms. For SITOP power supplies with a lower rated output current,
this diode can also be used, but it is over-dimensioned.
Manufacturer: General Instrument
Distributor: e.g. RS Components, Spoerle
SITOP power
+
-
SITOP power
+
-
G_KT01_EN_00059
Load
KT10_EN_gesamt.book Seite 15 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Battery charging, fusing of the 24 V DC output
circuit, selectivity
16/16
Siemens KT 10.1 2012
16
Battery charging with SITOP power supplies
The power supplies SITOP PSU300M12 V/20 A (Order No.
6EP1424-3BA00) and 24 V/30 A (Order No. 6EP1437-3BA20)
are suitable for charging lead batteries.
In the case of a V/I characteristic set for parallel operation, the
battery will be charged with a constant current until
approximately 95 % of the set SITOP output voltage has been
achieved. The charging current is then continuously reduced from
1.2 rated current at 95 % of the set voltage to approximately 0
A or the self-discharge current of the battery at 100 % of the set
output voltage, that is, resistance characteristic in this range.
As reverse voltage protection and polarity reversal protection,
we recommend that a diode suitable for at least 1.2 rated current
of the power supply with a blocking voltage of at least 40 V is
connected in series with the "+" output (anode connected to "+"
output of the SITOP modular and cathode connected to positive
pole of the battery)..
The output voltage of the power supply must be set at no-load to
the end-of-charge voltage plus the voltage drop at the diode. For
an end-of-charge voltage of e. g. 27.0 V DC (usual at 20 C to
30 C battery temperature; in each case, compliance with the
specifications of the battery manufacturer must be observed!)
and 0.8 V voltage drop at the diode, SITOP modular must be set
to 27.8 V during no-load operation.
General note for using SITOP power supplies as a battery-
charging unit
When SITOP modular is used as a battery charging unit, the
regulations of VDE 0510 or the relevant national regulations must
be observed, and adequate ventilation of the battery location
must be provided. The SITOP modular power supplies are
designed as rack-mounting units, and protection against electric
shock should therefore be provided by installation in an
appropriate housing.
The value recommended by the battery manufacturer must be
set as the end-of-charge voltage (depending on the battery
temperature). An ideal temperature for the lead-acid battery is
between +20 to 30 C and the recommended end-of-charge
voltage in this case is usually about 27 V.
Fusing of 24 V power supply circuits and
selectivity
With non-stabilized rectifiers (power transformer equipped with
rectifier) the output usually had to be protected with a suitable
fuse so that its rectifier diodes would not fail in the event of an
overload or a short-circuit (this would destroy the DC loads due
to the resulting alternating voltage and lead to serious damage
in most cases).
On the other hand, the stabilized SITOP power supplies are
provided with integral electronic short-circuit protection that
automatically protects both the power supply and the supplied
24 V DC circuits against an excess current in the event of an
overload/short-circuit. A distinction must be made between the
following three cases with respect to fusing on the secondary
side:
Example 1: No fusing
Fusing the secondary side (24 V DC) for protecting the load
circuits and lines is not required if the respective cross-sections
are selected for the maximum possible output current RMS
value. Depending on the event (short-circuit or overload) this
may either be the short-circuit RMS value or the current limitation
value.
Fusing of 24 V power supply circuits and
selectivity (continued)
Example SITOP modular 10 A (Order No.: 6EP1334-3BA00)
10 A rated current
Current limitation typ. 12 A
Short-circuit current rms value approximately 12 A
The technical specifications usually specify typical values,
maximum values are approximately 2 A above the typical value.
In the example here, a maximum possible output current rms
value of approximately 14 must therefore be used for line
dimensioning.
Example 2: Reduced conductor cross-sections
If smaller conductor cross-sections are used than specified in the
relevant standards (e.g. EN 60204-1), the affected 24 V load
infeed cables must be protected with a suitable circuit breaker.
It is then unimportant whether the power supply enters current
limiting mode (overload) or delivers the maximum short-circuit
current (low-resistance short-circuit).
The load supply is in any case protected against an overload by
the line protection matched to the conductor cross-section.
Example 3: Selectivity
In cases where a load which has failed (e.g. because of a short-
circuit) has to be rapidly detected or where it is essential to
selectively switch it off before the power supply enters current
limiting mode (with current limiting mode, the voltage would also
fall for all remaining 24 V DC loads), there are two possibilities for
the secondary side connection:
A selectivity module SITOP PSE200U or a diagnostics
module SITOP select for the distribution of the 24 V DC
supply over up to 4 load feeders.
Each output is adjustable between
0.5 A and 3 A (Order No.: 6EP1961-2BA11) or
3 A and 10 A ( (Order No.: 6EP1961-2BA21) or
2 A and 10 A ( Order No.: 6EP1961-2BA00).
Series connection of appropriate 24 V DC fuses or miniature
circuit breakers
The basis for selection of the 24 V DC fuse or circuit-breaker is
the short-circuit current above the rated current which the SITOP
power supplies deliver in the event of a short-circuit during
operation (values are specified in the respective technical
specifications under "Output, dynamic V/I on short-circuit during
operation").
It is not easy to calculate the amount of the short-circuit current
flowing into the usually not ideal "short-circuit" and the amount
flowing into the remaining loads. This depends on the type of
overload (high-resistance or low-resistance short-circuit) and
the type of load connected (resistive, inductive and
capacitive/electronic loads).
However, it can be assumed with a first approximation in the
average case encountered in practice that the difference of
dynamic overcurrent minus 50 % SITOP rated output current is
available for the immediate tripping of a circuit-breaker within a
typical time of 12 ms (with 14 times the rated DC with a circuit-
breaker characteristic C acc. to IEC 898, or with 7 times the
rated DC with a circuit-breaker characteristic B or with 5 times
the rated DC with a circuit-breaker characteristic A). Please refer
to the following tables for circuit-breakers appropriate for
selected fusing according to this assumption.
KT10_EN_gesamt.book Seite 16 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Fusing of the 24 V DC output circuit,
selectivity
16/17
Siemens KT 10.1 2012
16
List of ordering data and tripping characteristics of single-pole circuit-breakers 5SY4...
acc. to IEC 898 / EN 60898, for use up to 60 V DC (250 V AC, switching capacity 10.000 A)

Rated current Tripping
characteristic
Order No. Range for immediate tripping
< 100 ms for operation
with direct current (alternating
current)
DC current for immediate
tripping
in < 100 ms
DC current for immediate
tripping
in approx. 12 ms
1 A Type A 5SY4 101-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 2 ... 5 A 5 A DC
1 A Type C 5SY4 101-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 5 ... 14 A 14 A DC
1.6 A Type A 5SY4 115-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 3.2 ... 8 A 8 A DC
1.6 A Type C 5SY4 115-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 8 ... 22.4 A 22.4 A DC
2 A Type A 5SY4 102-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 4 ... 10 A 10 A DC
2 A Type C 5SY4 102-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 10 ... 28 A 28 A DC
3 A Type A 5SY4 103-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 6 ... 15 A 15 A DC
3 A Type C 5SY4 103-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 15 ... 42 A 42 A DC
4 A Type A 5SY4 104-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 8 ... 20 A 20 A DC
4 A Type C 5SY4 104-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 20 ... 56 A 56 A DC
6 A Type A 5SY4 106-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 12 ... 30 A 30 A DC
6 A Type B 5SY4 106-6 DC: 3 ... 7
(AC: 3 ... 5) I
rated
DC 18 ... 42 A 42 A DC
6 A Type C 5SY4 106-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 30 ... 84 A 84 A DC
8 A Type A 5SY4 108-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 16 ... 40 A 40 A DC
8 A Type C 5SY4 108-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 40 ... 112 A 112 A DC
10 A Type A 5SY4 110-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 20 ... 50 A 50 A DC
10 A Type B 5SY4 110-6 DC: 3 ... 7
(AC: 3 ... 5) I
rated
DC 30 ... 70 A 70 A DC
10 A Type C 5SY4 110-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 50 ... 140 A 140 A DC
13 A Type A 5SY4 113-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 26 ... 65 A 65 A DC
13 A Type B 5SY4 113-6 DC: 3 ... 7
(AC: 3 ... 5) I
rated
DC 39 ... 91 A 91 A DC
13 A Type C 5SY4 113-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 65 ... 182 A 182 A DC
16 A Type A 5SY4 116-5 DC: 2 ... 5
(AC: 2 ... 3) I
rated
DC 32 ... 80 A 80 A DC
16 A Type B 5SY4 116-6 DC: 3 ... 7
(AC: 3 ... 5) I
rated
DC 48 ... 112 A 112 A DC
16 A Type C 5SY4 116-7 DC: 5 ... 14
(AC: 5 ... 10) I
rated
DC 80 ... 224 A 224 A DC
KT10_EN_gesamt.book Seite 17 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Fusing of the 24 V DC output circuit,
selectivity
16/18
Siemens KT 10.1 2012
16
Miniature circuit breakers
1)
according to EN 60898 (DIN VDE 0641 T11), in 24 V DC circuits
which are powered by SITOP modular or SITOP smart power supplies
I
out rated
: Rated output current.
I
out dyn
: Dynamic overcurrent at short-circuit in operation.
: Immediate tripping, since dynamic overcurrent resulting from a
short circuit > limit current of electromagnetic tripping.
: Immediate tripping very likely, since at least 50 % of dynamic
overcurrent resulting from a short circuit is within tripping
characteristic.
X: No immediate tripping.
1) This selection of miniature circuit breakers is based on the maximum
possible short-circuit current of the power supply and on the tripping
characteristic at +20 C.
Other criteria, which might also be relevant in practice,
like for example self-heating, ambient temperature, line impedance,
and currents flowing in parallel paths, were not considered.
Order No. I
out rated
I
out dyn
Characteristic A
1 A 1.6 A 2 A 3 A 4 A 6 A 8 A 10 A 13 A 16 A
6EP1332-
2BA10
2.5 A 7 A/
200 ms

X X X X X X X
6EP1333-
3BA00
5 A 15 A/
25 ms

X X X X X
6EP1333-
2BA01
5 A 17 A/
200 ms

X X X X X
6EP1333-
2AA01
5 A 17 A/
200 ms

X X X X X
6EP1334-
3BA00
10 A 30 A/
25 ms

X X X
6EP1334-
2BA01
10 A 33 A/
200 ms

X X X
6EP1334-
2AA01
10 A 33 A/
200 ms

X X X
6EP1434-
2BA10
10 A 16 A/
100 ms

X X X X X
6EP1336-
3BA00
20 A 60 A/
25 ms


6EP1336-
3BA10
20 A 60 A/
25 ms


6EP1436-
3BA00
20 A 60 A/
25 ms


6EP1436-
3BA10
20 A 60 A/
25 ms


6EP1436-
2BA10
20 A 35 A/
100 ms



X X
6EP1337-
3BA00
40 A 120 A/
25 ms

6EP1437-
3BA00
40 A 120 A/
25 ms

6EP1437-
3BA10
40 A 120 A/
25 ms

6EP1437-
2BA20
40 A 65 A/
120 ms

KT10_EN_gesamt.book Seite 18 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Fusing of the 24 V DC output circuit,
selectivity
16/19
Siemens KT 10.1 2012
16
Characteristic B Characteristic C
6 A 10 A 13 A 16 A 1 A 1.6 A 2 A 3 A 4 A 6 A 8 A 10 A 13 A 16 A
X X X X X X X X X X X X X X
X X X X

X X X X X X X X X
X X X X

X X X X X X X X
X X X X

X X X X X X X X
X X X

X X X X X X
X X X

X X X X X X
X X X

X X X X X X
X X X X

X X X X X X X X

X X

X X X X

X X

X X X X

X X

X X X X

X X

X X X X
X X X

X X X X X X

X X

X X

X X

X

X X X X
KT10_EN_gesamt.book Seite 19 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Technical information and configuring notes
Standards and approvals
16/20
Siemens KT 10.1 2012
16
Overview of important standards and approvals

Further information
Additional information is available in the Internet under:
2D dimensional drawings, 3D CAD data, circuit diagram
macros:
www.siemens.com/sitop-cax
Operating instructions:
www.siemens.de/sitop-manuals
Find the right product with the SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
EN European standards
EN 50178 Electronic equipment for use in power installations
EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement
EN 60529 Degrees of protection provided by enclosures (IP-Code)
EN 60721 Classification of environmental conditions
EN 60950-1 Information technology equipment Safety
EN 61000-3-2 Electromagnetic compatibility (EMC) Part 3-2: Limits for harmonic current emissions (equipment input
current 16 A per phase)
EN 61000-6-2 Electromagnetic compatibility (EMC) Part 6-2: Generic standards Immunity for industrial environments
EN 61000-6-3 Electromagnetic compatibility (EMC) Part 6-3: Generic standards Emission standard for residential,
commercial and light industrial environments
UL Underwriters Laboratories
UL 508 Industrial control equipment
UL 1604 Electrical equipment for use in class I and class II, division 2. and class III hazardous (classified) locations
UL 1778 Uninterruptible power supply equipment
UL 2367 Standard for solid state overcurrent protectors
UL 60079 Electrical apparatus for explosive gas atmospheres
UL 60950 -1 Information technology equipment Safety
CSA Canadian Standards Association
CSA C22.2 No. 14 Industrial control equipment
CSA C22.2 No. 142 Process control equipment
CSA C22.2 No. 107.1 General use power supplies
CSA C22.2 No. 60079 Electrical apparatus for explosive gas atmospheres
CSA C22.2 No. 60950-1 Information technology equipment Safety
ATEX Equipment and protective systems intended for use in Potentially Explosive Atmospheres
FM Factory Mutual Research
ABS American Bureau of Shipping
GL Germanischer Lloyd
KT10_EN_gesamt.book Seite 20 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Siemens KT 10.1 2012
17
17/2 Partners at
Industry Automation and
Drive Technologies
17/2 Contact partners worldwide
17/3 Siemens Solution Partners
17/4 Online Services
17/4 Information and ordering
in the Internet and on DVD
17/5 Service & Support
17/5 Services covering the entire life cycle
17/7 Knowledge Base on DVD
17/7 Automation Value Card
17/8 Alphabetical index
17/9 Order No. index
17/12 Terms and conditions of sale
and delivery
17/12 Export regulations
Appendix
KT10_EN_gesamt.book Seite 1 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Partner at Industry Automation and Drive Technologies
17/2
Siemens KT 10.1 2012
17
At Siemens Industry Automation and Drive Technologies, more
than 85 000 people are resolutely pursuing the same goal: long-
term improvement of your competitive ability. We are committed
to this goal. Thanks to our commitment, we continue to set new
standards in automation and drive technology. In all industries
worldwide.
At your service locally, around the globe for consulting, sales,
training, service, support, spare parts ... on the entire Industry
Automation and Drive Technologies range.
Your personal contact can be found in our Contacts Database at:
www.siemens.com/automation/partner
You start by selecting a
Product group,
Country,
City,
Service.
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Partner at Industry Automation and Drive Technologies
Siemens Solution Partner Automation
17/3
Siemens KT 10.1 2012
17
Overview
Siemens Solution Partner Automation
Solution Partner: Highest quality - guaranteed
The products and systems from Siemens Industry Automation
and Drive Technologies offer the ideal platform for all automation
applications.
Under the name of Siemens Solution Partner Automation,
selected system integrators around the world act as uniformly
qualified solution providers for the Siemens range of products
and services in the fields of automation and drives. Day after
day, they utilize their qualified product and system know-how as
well as their excellent industry expertise to your advantage for
all requirements.
The partner emblem is the guarantee and indicator of proven
quality. The basis for this are defined quality features that identify
Solution Partners as reliable and competent solution providers:
Solution quality
Always a good result with tried and tested solutions expertise.
Expert quality
Certified technical competence ensures maximum efficiency.
Project quality
With proven project experience straight to the target.
Portfolio quality
Comprehensive portfolio for state-of-the-art solutions from a
single source.
Solution Partner Finder
The Siemens Solution Partner Program helps you to find the
optimum partner for your specific requirements.
Support is provided by the Solution Partner Finder, a compre-
hensive online platform that showcases the profiles of all our
solution partners. You can convince yourself of the competence
of the respective Solution Partner by means of the references
provided. Various search criteria are available for this purpose.
Once you have located a partner, you are only one small step
away from contacting them.
Find the right partner here for your specific task and convince
yourself of the solution competence provided:
https://www.siemens.com/automation/partnerfinder
Additional information on the Siemens Solution Partner Program
is available online at:
https://www.siemens.com/automation/solutionpartner
KT10_EN_gesamt.book Seite 3 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Online Services
Information and Ordering
in the Internet and on DVD
17/4
Siemens KT 10.1 2012
17
Siemens Industry Automation and Drive Technologies in the WWW
A detailed knowledge of the range of products and services
available is essential when planning and configuring automation
systems. It goes without saying that this information must always
be fully up-to-date.
Siemens Industry Automation and Drive Technologies has
therefore built up a comprehensive range of information in the
World Wide Web, which offers quick and easy access to all data
required.
Under the address
www.siemens.com/industry
you will find everything you need to know about products, sys-
tems and services.
Product Selection Using the Interactive Catalog CA 01 of Industry
Detailed information together with convenient interactive
functions:
The interactive catalog CA 01 covers more than 80 000 products
and thus provides a full summary of the Siemens Industry Auto-
mation and Drive Technologies product base.
Here you will find everything that you need to solve tasks in the
fields of automation, switchgear, installation and drives.
All information is linked into a user interface which is easy to
work with and intuitive.
After selecting the product of your choice you can order at the
press of a button, by fax or by online link.
Information on the interactive catalog CA 01 can be found in the
Internet under
www.siemens.com/automation/ca01
or on DVD.
Easy Shopping with the Industry Mall
The Industry Mall is the virtual department store of Siemens AG
in the Internet. Here you have access to a huge range of prod-
ucts presented in electronic catalogs in an informative and at-
tractive way.
Data transfer via EDIFACT allows the whole procedure from
selection through ordering to tracking of the order to be carried
out online via the Internet.
Numerous functions are available to support you.
For example, powerful search functions make it easy to find the
required products, which can be immediately checked for avail-
ability. Customer-specific discounts and preparation of quotes
can be carried out online as well as order tracking and tracing.
Please visit the Industry Mall on the Internet under:
www.siemens.com/industrymall
KT10_EN_gesamt.book Seite 4 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Service & Support
The unmatched complete service
for the entire life cycle
17/5
Siemens KT 10.1 2012
17
For machine constructors, solution providers and plant opera-
tors: The service offering from Siemens Industry, Automation and
Drive Technologies includes comprehensive services for a wide
range of different users in all sectors of the manufacturing and
process industry
To accompany our products and systems, we offer integrated
and structured services that provide valuable support in every
phase of the life cycle of your machine or plant - from planning
and implementation through commissioning as far as mainte-
nance and modernization.
Our Service & Support accompanies you worldwide in all mat-
ters concerning automation and drives from Siemens. We pro-
vide direct on-site support in more than 100 countries through all
phases of the life cycle of your machines and plants.
You have an experienced team of specialists at your side to pro-
vide active support and bundled know-how. Regular training
courses and intensive contact among our employees - even
across continents - ensure reliable service in the most diverse
areas.
Online Support
The comprehensive online infor-
mation platform supports you in
all aspects of our Service & Sup-
port at any time and from any lo-
cation in the world.
www.siemens.com/
automation/service&support
Technical Support
Expert advice on technical
questions with a wide range of
demand-optimized services for
all our products and systems.
www.siemens.com/
automation/support-request
Technical Consulting
Support in planning and design-
ing your project: From detailed
actual-state analysis, definition
of the goal and consulting on
product and system questions
right through to the creation of
the automation solution.
Training
Extend your competitive edge -
through practical know-how
directly from the manufacturer.
www.siemens.com/sitrain
S
p
a
r
e

P
a
r
t
s
S
p
a
r
e

P
a
r
t
s
T
e
c
h
n
ic
a
l
S
u
p
p
o
r
t
Technical
Consulting
Technical
Consulting
T
e
c
h
n
ic
a
l
S
u
p
p
o
r
t
Service
Programs
Service
Programs
Engineering
Support
Engineering
Support
Training Training
Modernization
Services
Modernization
Services
O
n
lin
e
S
u
p
p
o
r
t
O
n
lin
e
S
u
p
p
o
r
t
F
i
e
l
d

S
e
r
v
i
c
e
F
i
e
l
d

S
e
r
v
i
c
e
Optimization
Services
Optimization
Services
Contact information is available in the Internet at:
www.siemens.com/automation/partner
KT10_EN_gesamt.book Seite 5 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Service & Support
The unmatched complete service
for the entire life cycle
17/6
Siemens KT 10.1 2012
17
Engineering Support
Support during project engi-
neering and development with
services fine-tuned to your re-
quirements, from configuration
through to implementation of an
automation project.
Field Service
Our Field Service offers you ser-
vices for commissioning and
maintenance - to ensure that
your machines and plants are
always available.
Spare parts
In every sector worldwide,
plants and systems are required
to operate with constantly in-
creasing reliability. We will pro-
vide you with the support you
need to prevent a standstill from
occurring in the first place: with
a worldwide network and opti-
mum logistics chains.
Repairs
Downtimes cause problems in
the plant as well as unnecessary
costs. We can help you to re-
duce both to a minimum - with
our worldwide repair facilities.
Optimization
During the service life of ma-
chines and plants, there is often
a great potential for increasing
productivity or reducing costs.
To help you achieve this poten-
tial, we are offering a complete
range of optimization services.
Modernization
You can also rely on our support
when it comes to modernization
- with comprehensive services
from the planning phase all the
way to commissioning.
Service programs
Our service programs are se-
lected service packages for an
automation and drives system or
product group. The individual
services are coordinated with
each over to ensure smooth
coverage of the entire life cycle
and support optimum use of
your products and systems.
The services of a Service Pro-
gram can be flexibly adapted at
any time and used separately.
Examples of service programs:
7 Service contracts
7 Plant IT Security Services
7 Life Cycle Services for Drive Engineering
7 SIMATIC PCS 7 Life Cycle Services
7 SINUMERIK Manufacturing Excellence
7 SIMATIC Remote Support Services
Advantages at a glance:
7 Reduced downtimes for increased productivity
7 Optimized maintenance costs due to a tailored scope of ser-
vices
7 Costs that can be calculated and therefore planned
7 Service reliability due to guaranteed response times and
spare part delivery times
7 Customer service personnel will be supported and relieved of
additional tasks
7 Comprehensive service from a single source, fewer interfaces
and greater expertise
Contact information is available in the Internet at:
www.siemens.com/automation/partner
KT10_EN_gesamt.book Seite 6 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Service & Support
17/7
Siemens KT 10.1 2012
17
Knowledge Base on DVD
For locations without online con-
nections to the Internet there are
excerpts of the free part of the
information sources available on
DVD (Service & Support Knowl-
edge Base). This DVD contains
all the latest product information
at the time of production (FAQs,
Downloads, Tips and Tricks, Up-
dates) as well as general infor-
mation on Service & Support.
The DVD also includes a full-text search and our Knowledge
Manager for targeted searches for solutions. The DVD will be up-
dated every 4 months.
Just the same as our online offer in the Internet, the Service &
Support Knowledge Base on DVD comes complete in 5 lan-
guages (German, English, French, Italian, Spanish).
You can order the Service & Support Knowledge Base DVD
from your Siemens contact.
Order no. 6ZB5310-0EP30-0BA2
Automation Value Card
Small card - great support
The Automation Value Card is an integral component of the com-
prehensive service concept with which Siemens Drive Automa-
tion and Drive Technologies will accompany you in each phase
of your automation project.
It doesn't matter whether you want just specific services from our
Technical Support or want to purchase something on our Online
portal, you can always pay with your Automation Value Card. No
invoicing, transparent and safe. With your personal card number
and associated PIN you can view the state of your account and
all transactions at any time.
Services on card. This is how it's done.
Card number and PIN are on the back of the Automation Value
Card. When delivered, the PIN is covered by a scratch field,
guaranteeing that the full credit is on the card.
By entering the card number and PIN you have full access to the
Service & Support services being offered. The charge for the
services procured is debited from the credits on your Automa-
tion Value Card.
All the services offered are marked in currency-neutral credits,
so you can use the Automation Value Card worldwide.
Order your Automation and Value Card easily and comfortably
like a product with your sales contact.
Detailed information on the services offered is available on our
Internet site at:
www.siemens.com/automation/service&support
Service & Support la Card: Examples
Automation Value Card order numbers
Credits Order no.
200 6ES7 997-0BA00-0XA0
500 6ES7 997-0BB00-0XA0
1 000 6ES7 997-0BC00-0XA0
10 000 6ES7 997-0BG00-0XA0
Technical Support
Priority Priority processing for urgent cases
24 h Availability round the clock
Extended Technical consulting for complex questions
Mature
Products
Consulting service for products that are not available
any more
Support Tools in the Support Shop
Tools that can be used directly for configuration, anal-
ysis and testing
KT10_EN_gesamt.book Seite 7 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Alphabetical index
17/8
Siemens KT 10.1 2012
17
A
Automation Value Card .............................................................................17/7
B
Buffer module SITOP modular ..................................................................11/2
C
Circuit diagrams ........................................................................................11/6
Class2 version 24 V/3.7 A ...........................................................................4/3
Conditions of sale and delivery ...............................................................17/12
Configuring notes ......................................................................................16/2
Connector for devices in IP65 and IP67 ...................................................14/2
D
DC/DC converter .........................................................................................2/3
Device labeling plates ..............................................................................14/2
E
Export regulations ...................................................................................17/12
F
Flat design 24 V/10 A ..................................................................................7/3
Flat design 24 V/5 A ....................................................................................5/3
I
Installation notes......................................................................................16/10
International supply voltages and frequencies in low-voltage systems ...16/5
K
Knowledge Base on DVD .........................................................................17/7
L
LOGO!Power 24 V/1.3 A .............................................................................2/3
LOGO!Power 12 V/1.9 A ...........................................................................13/6
LOGO!Power 12 V/4.5 A ...........................................................................13/7
LOGO!Power 15 V/1.9 A .........................................................................13/12
LOGO!Power 15 V/4 A ............................................................................13/12
LOGO!Power 24 V/2.5 A .............................................................................3/2
LOGO!Power 24 V/4 A ................................................................................4/2
LOGO!Power 5 V/3 A ................................................................................13/4
LOGO!Power 5 V/6.3 A .............................................................................13/4
M
Mounting adapter for DIN rail ...................................................................14/2
Mounting bracket ......................................................................................14/2
Mounting, mounting areas and installation options .................................16/10
O
Outdoor version 24 V/2 A.............................................................................2/3
Outdoor version 24 V/5 A ............................................................................5/3
P
Parallel connections for voltage increase ...............................................16/15
Parallel connections for performance enhancement ..............................16/14
Partners at Industry Automation and Drive Technologies ........................17/2
Power connection plug for PSU300P ........................................................14/2
PSA100E 24 V/12 A ....................................................................................8/2
PSA100E 24 V/2.5 A ...................................................................................3/3
PSA100E 24 V/4 A ......................................................................................4/3
PSA100E 24 V/6 A ......................................................................................6/2
PSU100D 12 V/3 A ....................................................................................13/7
PSU100D 24 V/12.5 A .................................................................................8/2
PSU100D 24 V/2.1 A ...................................................................................3/3
PSU100D 24 V/3.1 A ...................................................................................4/3
PSU100D 24 V/4.1 A ...................................................................................4/3
PSU100D 24 V/6.2 A ...................................................................................6/2
PSU300B 24 V/30 A ..................................................................................10/2
PSU300P 24 V/8 A ......................................................................................9/2
R
Redundancy module PSE202U ................................................................11/2
S
S7-1200 version 24 V/2.5 A ........................................................................ 3/3
S7-200-Type 24 V/3.5 A .............................................................................. 4/2
S7-300 version 24 V/3 A ............................................................................. 2/3
S7-300 version 24 V/10 A ........................................................................... 7/3
S7-300 version 24 V/5 A ............................................................................. 5/3
Series connection to increase the voltage .............................................. 16/15
Signaling module SITOP modular ............................................................ 11/2
Siemens Solution Partner Automation ...................................................... 17/3
SIPLUS extreme ........................................................................................ 15/2
SITOP 1-phase ........................................................................................... 2/2
SITOP compact PSU100C 12 V/2 A ......................................................... 13/6
SITOP compact PSU100C 12 V/6.5 A ...................................................... 13/7
SITOP compact PSU100C 24 V/0.6 A ........................................................ 2/2
SITOP compact PSU100C 24 V/1.3 A ........................................................ 2/2
SITOP compact PSU100C 24 V/2.5 A ........................................................ 3/2
SITOP compact PSU100C 24 V/4 A ........................................................... 4/2
SITOP DC/DC 12 V/2.5 A ......................................................................... 13/6
SITOP dual 2 x 15 V/3.5 A ...................................................................... 13/12
SITOP flexi 3-52 V/2-10 A ......................................................................... 13/2
SITOP in SIMATIC-Design .......................................................................... 2/3
SITOP in SIMATIC-Design 24 V/10 A .......................................................... 7/3
SITOP in SIMATIC-Design 24 V/2.5 A ......................................................... 3/3
SITOP in SIMATIC-Design 24 V/3.5 A ......................................................... 4/2
SITOP in SIMATIC-Design 24 V/5 A ............................................................ 5/3
SITOP lite PSU100L 24 V/10 A ................................................................... 7/3
SITOP lite PSU100L 24 V/2.5 A .................................................................. 3/3
SITOP lite PSU100L 24 V/5 A ..................................................................... 5/3
SITOP modular 24 V/10 A .................................................................... 7/2, 9/2
SITOP modular 24 V/20 A .................................................................... 8/3, 9/3
SITOP modular 24 V/40 A .................................................................. 8/3, 10/3
SITOP modular 24 V/5 A ...................................................................... 5/2, 9/2
SITOP modular 48 V/20 A ....................................................................... 13/14
SITOP modular PSU100M 24 V/20 A .......................................................... 8/2
SITOP modular PSU300M 24 V/20 A .......................................................... 9/3
SITOP modular PSU300M 24 V/40 A ........................................................ 10/2
SITOP modular PSU300M 48 V/10 A ...................................................... 13/14
SITOP modular PSU400M 24 V/20 A .......................................................... 8/3
SITOP smart 24 V/10 A ............................................................................... 7/2
SITOP smart 24 V/2.5 A .............................................................................. 3/2
SITOP smart 24 V/5 A ................................................................................. 5/2
SITOP smart PSU300S 24 V/10 A ............................................................... 9/3
SITOP smart PSU300S 24 V/20 A ............................................................... 9/3
SITOP smart PSU300S 24 V/40 A ............................................................. 10/3
Software SITOP DC UPS .......................................................................... 12/4
Solution Partner Finder ............................................................................. 17/3
Standards and approvals ....................................................................... 16/20
Support ..................................................................................................... 17/5
U
Uninterruptible DC power supplies ........................................................... 12/2
KT10_EN_gesamt.book Seite 8 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix
Order No. index
17/9
Siemens KT 10.1 2012
17
Order No. Page Export regulations
AL ECCN
3RK1
3RK1 911-2BE50 14/2 N N
3RT1
3RT1 900-1SB20 14/2 N N
6AG1
6AG1 053-1AA00-2AA0 15/3 9I999 N
6AG1 203-1AA00-2AA0 15/3 9I999 N
6AG1 203-1SH31-2AA0 15/3 9I999 EAR99H
6AG1 305-1AA00-2AA0 15/3 9I999 EAR99H
6AG1 305-1BA80-2AA0 15/3 9I999 N
6AG1 307-1EA80-2AA0 15/3 9I999 N
6AG1 307-1KA02-7AA0 15/3 N N
6AG1 332-1SH71-4AA0 15/3 N N
6AG1 332-1SH71-7AA0 15/3 9I999 N
6AG1 334-2BA01-4AA0 15/3 9I999 N
6AG1 334-3BA00-2AA0 15/3, 15/4 9I999 N
6AG1 334-3BA00-4AA0 15/3 9I999 N
6AG1 336-3BA00-7AA0 15/3 N N
6AG1 337-3BA00-4AA0 15/3 9I999 N
6AG1 436-3BA00-7AA0 15/4 N N
6AG1 437-3BA00-4AA0 15/4 9I999 EAR99H
6AG1 437-3BA10-7AA0 15/4 N N
6AG1 931-2BA00-3AA0 15/3 9I999 EAR99H
6AG1 931-2EC21-2AA0 15/4 9I999 N
6AG1 931-2FC21-7AA0 15/4 N N
6AG1 936-3BA00-4AA0 15/3 9I999 N
6AG1 933-3BA00-2AA0 15/3, 15/4 9I999 N
6AG1 961-3BA01-7AA0 15/4 N N
6AG1 961-3BA10-6AA0 15/4 9I999 EAR99H
6AG1 961-3BA10-7AA0 15/4 9I999 N
6AG1 961-3BA21-4AX0 15/4 9I999 N
6AG1 961-3BA21-7AX0 15/4 N N
6EP1
6EP1 232-1AA00 3/6 N N
6EP1 232-1AA10 4/6 N N
6EP1 233-1AA00 6/4 N N
6EP1 234-1AA00 8/8 N N
6EP1 311-1SH03 13/16 N N
6EP1 311-1SH13 13/16 N N
6EP1 321-1LD00 13/16 N EAR99H
6EP1 321-1SH03 13/16 N N
6EP1 321-5BA00 13/16 N N
6EP1 322-1LD00 13/17 N EAR99H
6EP1 322-1SH03 13/16 N N
6EP1 322-5BA10 13/17 N N
6EP1 331-1LD00 3/6 N EAR99H
6EP1 331-1SH03 2/6 N N
6EP1 331-5BA00 2/6 N N
6EP1 331-5BA10 2/6 N N
6EP1 332-1LB00 3/6 N N
6EP1 332-1LD00 4/6 N EAR99H
6EP1 332-1LD10 4/6 N N
6EP1 332-1SH31 4/6 N N
6EP1 332-1SH43 3/6 N N
6EP1 332-1SH52 4/6 N N
6EP1 332-1SH71 3/6 N N
6EP1 332-2BA00 4/6 N N
6EP1 332-2BA10 3/6 N N
6EP1 332-5BA00 3/6 N N
6EP1 332-5BA10 4/6 N N
6EP1 333-1AL12 5/6 N N
6EP1 333-1LB00 5/6 N N
6EP1 333-1LD00 6/4 N EAR99H
6EP1 333-2AA01 5/6 N N
6EP1 333-2BA01 5/6 N N
6EP1 333-3BA00 5/6, 9/6 N N
6EP1 333-3BA00-8AC0 5/6 N N
6EP1 334-1AL12 7/6 N N
6EP1 334-1LB00 7/6 N N
Order No. Page Export regulations
AL ECCN
6EP1 334-1LD00
8/8 N EAR99H
6EP1 334-2AA01 7/6 N N
6EP1 334-2BA01 7/6 N N
6EP1 334-3BA00 7/6, 9/6 N N
6EP1 334-3BA00-8AB0 7/6 N N
6EP1 336-3BA00 8/8 N N
6EP1 336-3BA00-8AA0 8/8 N N
6EP1 336-3BA10 8/8 N N
6EP1 337-3BA00 8/8 N N
6EP1 351-1SH03 13/17 N N
6EP1 352-1SH03 13/17 N N
6EP1 353-0AA00 13/17 N N
6EP1 353-2BA00 13/16 N N
6EP1 424-3BA00 13/17 N N
6EP1 433-2CA00 9/6 N EAR99H
6EP1 436-3BA00 9/6 N N
6EP1 436-3BA00-8AA0 9/6 N N
6EP1 436-3BA10 9/6 N N
6EP1 437-3BA00 10/6 N N
6EP1 437-3BA00-8AA0 10/6 N N
6EP1 437-3BA10 10/6 N N
6EP1 437-3BA20 10/6 N N
6EP1 456-3BA00 13/17 N N
6EP1 457-3BA00 13/17 N N
6EP1 536-3AA00 8/8 N N
6EP1 621-2BA00 13/16 N N
6EP1 731-2BA00 2/6 N N
6EP1 732-0AA00 2/6 N EAR99H
6EP1 931-2DC21 12/22 N N
6EP1 931-2DC31 12/22 N N
6EP1 931-2DC42 12/22 N N
6EP1 931-2EC21 12/22 N N
6EP1 931-2EC31 12/22 N N
6EP1 931-2EC42 12/22 N N
6EP1 931-2FC21 12/22 N N
6EP1 931-2FC42 12/22 N N
6EP1 933-2EC41 12/22 N N
6EP1 933-2EC51 12/22 N N
6EP1 933-2NC01 12/22 N EAR99H
6EP1 933-2NC11 12/22 N EAR99H
6EP1 935-5PG01 12/22 N N
6EP1 935-6MC01 12/22 N EAR99H
6EP1 935-6MD11 12/22 N N
6EP1 935-6MD31 12/22 N N
6EP1 935-6ME21 12/22 N N
6EP1 935-6MF01 12/22 N N
6EP1 961-2BA00 11/9 N N
6EP1 961-2BA11 11/9 N N
6EP1 961-2BA21 11/9 N EAR99
6EP1 961-3BA01 11/9 N N
6EP1 961-3BA10 11/9 N N
6EP1 961-3BA21 11/9 N N
6EP1 967-2AA00 11/9 N N
6EP1 971-1BA00 14/2 N N
6EP1 971-2BA00 14/2 N N
6EP1 975-2ES00 12/22, 14/2 N N
6EP1 434-2BA10 9/6 N N
6EP1 436-2BA10 9/6 N N
6EP1 437-2BA20 10/6 N N
6ES7
6ES7 148-4PC00-0HA0 9/6 N EAR99H
6ES7 305-1BA80-0AA0 2/6 N N
6ES7 307-1BA01-0AA0 2/6 N N
6ES7 307-1EA01-0AA0 5/6 N N
6ES7 307-1EA80-0AA0 5/6 N N
6ES7 307-1KA02-0AA0 7/6 N N
6ES7 390-6BA00-0AA0 14/2 N N
KT10_EN_gesamt.book Seite 9 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Appendix

Notes
17/10
Siemens KT 10.1 2012
17

KT10_EN_gesamt.book Seite 10 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
Appendix

Notes
17/11
Siemens KT 10.1 2012
17

KT10_EN_gesamt.book Seite 11 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
Appendix

Notes
17/12
Siemens KT 10.1 2012
17

KT10_EN_gesamt.book Seite 12 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
Appendix

Notes
17/13
Siemens KT 10.1 2012
17

KT10_EN_gesamt.book Seite 13 Mittwoch, 12. Oktober 2011 11:00 11


Siemens AG 2011
Appendix

Conditions of Sale and Delivery
Export regulations
17/14
Siemens KT 10.1 2012
17
Terms and Conditions of Sale and Delivery
By using this catalog you can acquire hardware and software
products described therein from Siemens AG subject to the fol-
lowing terms. Please note! The scope, the quality and the condi-
tions for supplies and services, including software products, by
any Siemens entity having a registered office outside of Ger-
many, shall be subject exclusively to the General Terms and
Conditions of the respective Siemens entity. The following terms
apply exclusively for orders placed with Siemens AG.
For customers with a seat or registered office in Germany
The General Terms of Payment as well as the General Condi-
tions for the Supply of Products and Services of the Electrical
and Electronics Industry shall apply.
For software products, the General License Conditions for Soft-
ware Products for Automation and Drives for Customers with a
Seat or registered Office in Germany shall apply.
For customers with a seat or registered office outside of
Germany
The General Terms of Payment as well as the General Condi-
tions for Supplies of Siemens, Automation and Drives for Cus-
tomers with a Seat or registered Office outside of Germany shall
apply.
For software products, the General License Conditions for Soft-
ware Products for Automation and Drives for Customers with a
Seat or registered Office outside of Germany shall apply.
General
The dimensions are in mm. In Germany, according to the Ger-
man law on units in measuring technology, data in inches only
apply to devices for export.
Illustrations are not binding.
Insofar as there are no remarks on the corresponding pages,
- especially with regard to data, dimensions and weights given -
these are subject to change without prior notice.
The prices are in (Euro) ex works, exclusive packaging.
The sales tax (value added tax) is not included in the prices.
It shall be debited separately at the respective rate according to
the applicable legal regulations.
Prices are subject to change without prior notice. We will debit
the prices valid at the time of delivery.
Surcharges will be added to the prices of products that contain
silver, copper, aluminum, lead and/or gold if the respective basic
official prices for these metals are exceeded. These surcharges
will be determined based on the official price and the metal fac-
tor of the respective product.
The surcharge will be calculated on the basis of the official price
on the day prior to receipt of the order or prior to the release
order.
The metal factor determines the official price as of which the
metal surcharges are charged and the calculation method used.
The metal factor, provided it is relevant, is included with the price
information of the respective products.
An exact explanation of the metal factor and the text of the Com-
prehensive Terms and Conditions of Sale and Delivery can be
downloaded at:
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf
Export regulations
Siemens shall not be obligated to fulfill this agreement if such
fulfillment is prevented by any impediments arising out of
national or international foreign trade or customs requirements
or any embargoes or other sanctions.
If you transfer goods (hardware and/ or software and/ or tech-
nology as well as corresponding documentation, regardless of
the mode of provision) delivered by us or works and services
(including all kinds of technical support) performed by us to a
third party worldwide, you shall comply with all applicable
national and international (re-) export control regulations.
If required to conduct export control checks, you, upon request
by us, shall promptly provide us with all information pertaining to
particular end customer, destination and intended use of goods,
works and services provided by us, as well as any export control
restrictions existing.
The products listed in this catalog / price list may be subject to
European / German and/or US export regulations.
Therefore, any export requiring a license is subject to approval
by the competent authorities.
According to current provisions, the following export regulations
must be observed with respect to the products featured in this
catalog / price list:
Even without a label or with an AL: N or ECCN: N, authoriza-
tion may be required due to the final destination and purpose for
which the goods are to be used.
The deciding factors are the AL or ECCN export authorization
indicated on order confirmations, delivery notes and invoices.
Errors excepted and subject to change without prior notice.
AL Number of the German Export List
Products marked other than N require an export
license.
In the case of software products, the export des-
ignations of the relevant data medium must also
be generally adhered to.
Goods labeled with an AL not equal to N are
subject to a European or German export authori-
zation when being exported out of the EU.
ECCN Export Control Classification Number
Products marked other than N are subject to a
reexport license to specific countries.
In the case of software products, the export
designations of the relevant data medium must
also be generally adhered to.
Goods labeled with an ECCN not equal to N
are subject to a US re-export authorization.
KT10_EN_gesamt.book Seite 14 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
Catalogs
Industry Automation, Drive Technologies and Low-Voltage Power Distribution
Further information can be obtained from our branch offices listed
in the appendix or at www.siemens.com/automation/partner
Interactive Catalog on DVD Catalog
for Industry Automation, Drive Technologies and
Low Voltage Distribution
CA 01
Drive Systems
Variable-Speed Drives
SINAMICS G110, SINAMICS G120
Standard Inverters
SINAMICS G110D, SINAMICS G120D
Distributed Inverters
D 11.1
SINAMICS G130 Drive Converter Chassis Units
SINAMICS G150 Drive Converter Cabinet Units
D 11
SINAMICS GM150, SINAMICS SM150
Medium-Voltage Converters
D 12
SINAMICS S120 Chassis Format Units and
Cabinet Modules
SINAMICS S150 Converter Cabinet Units
D 21.3
SINAMICS DCM Converter Units D 23.1
Three-phase Induction Motors
H-compact
H-compact PLUS
D 84.1
Asynchronous Motors Standardline D 86.1
Synchronous Motors with Permanent-Magnet
Technology, HT-direct
D 86.2
DC Motors DA 12
SIMOREG DC MASTER 6RA70 Digital Chassis
Converters
DA 21.1
SIMOREG K 6RA22 Analog Chassis Converters DA 21.2
PDF: SIMOREG DC MASTER 6RM70 Digital Converter
Cabinet Units
DA 22
SIMOVERT PM Modular Converter Systems DA 45
SIEMOSYN Motors DA 48
MICROMASTER 420/430/440 Inverters DA 51.2
MICROMASTER 411/COMBIMASTER 411 DA 51.3
SIMOVERT MASTERDRIVES Vector Control DA 65.10
SIMOVERT MASTERDRIVES Motion Control DA 65.11
Synchronous and asynchronous servomotors for
SIMOVERT MASTERDRIVES
DA 65.3
SIMODRIVE 611 universal and POSMO DA 65.4
SIMOTION, SINAMICS S120 and
Motors for Production Machines
PM 21
SINAMICS S110
The Basic Positioning Drive
PM 22
Low-Voltage Three-Phase-Motors
IEC Squirrel-Cage Motors D 81.1
MOTOX Geared Motors D 87.1
Automation Systems for Machine Tools SIMODRIVE
Motors
Converter Systems SIMODRIVE 611/POSMO
NC 60
Automation Systems for Machine Tools SINAMICS
Motors
Drive System SINAMICS S120
NC 61
Mechanical Driving Machines
FLENDER Standard Couplings MD 10.1
FLENDER SIG Standard industrial gear unit MD 30.1
Low-Voltage Power Distribution and
Electrical Installation Technology
Protection, Switching, Measuring & Monitoring Devices LV 10.1
Switchboards and Distribution Systems LV 10.2
GAMMA Building Management Systems ET G1
PDF: DELTA Switches and Socket Outlets ET D1
SICUBE System Cubicles and Cubicle Air-Conditioning LV 50
SIVACON 8PS Busbar Trunking Systems LV 70
PDF: These catalogs are only available as pdf files.
Motion Control Catalog
SINUMERIK & SIMODRIVE
Automation Systems for Machine Tools
NC 60
SINUMERIK & SINAMICS
Equipment for Machine Tools
NC 61
SINUMERIK 828D BASIC T/BASIC M,
SINAMICS S120 Combi and 1FK7/1PH8 motors
NC 82
SIMOTION, SINAMICS S120 and
Motors for Production Machines
PM 21
SINAMICS S110
The Basic Positioning Drive
PM 22
Drive and Control Components for Cranes CR 1
Power Supply and System Cabling
Power supply SITOP KT 10.1
System cabling SIMATIC TOP connect KT 10.2
Process Instrumentation and Analytics
Field Instruments for Process Automation FI 01
SIREC Recorders and Accessories MP 20
SIPART, Controllers and Software MP 31
Products for Weighing Technology WT 10
PDF: Process Analytical Instruments PA 01
PDF: Process Analytics,
Components for the System Integration
PA 11
Safety Integrated
Safety Technology for Factory Automation SI 10
SIMATIC HMI/PC-based Automation
Human Machine Interface Systems/
PC-based Automation
ST 80/
ST PC
SIMATIC Ident
Industrial Identification Systems ID 10
SIMATIC Industrial Automation Systems
Products for Totally Integrated Automation and
Micro Automation
ST 70
SIMATIC PCS 7 Process Control System ST PCS 7
Add-ons for the SIMATIC PCS 7
Process Control System
ST PCS 7.1
PDF: Migration solutions with the SIMATIC PCS 7
Process Control System
ST PCS 7.2
SIMATIC NET
Industrial Communication IK PI
SINVERT Photovoltaics
Inverters and Components for Photovoltaic Installations RE 10
SIRIUS Industrial Controls
SIRIUS Industrial Controls IC 10
SIRIUS Industrial Controls
(selected content from catalog IC 10)
IC 90
System Solutions
Applications and Products for Industry are part of the
interactive catalog CA 01
Download-Center
PDF versions of the catalogs are available on the Internet at:
www.siemens.com/automation/infocenter
KT10_EN_gesamt.book Seite 2 Mittwoch, 12. Oktober 2011 11:00 11
Siemens AG 2011
The information provided in this catalog contains descriptions or
characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of
further development of the products. An obligation to provide
the respective characteristics shall only exist if expressly agreed in
the terms of contract. Availability and technical specifications are
subject to change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third
parties for their own purposes could violate the rights of
the owners. www.siemens.com/sitop
Subject to change without prior notice
Order No. E86060-K2410-A111-A8-7600
MP.R1.SC. PPKG. 68.2.01 / Dispo 10001
KG 1111 6. AUM 160 En
Printed in Germany
Siemens AG 2011
Siemens AG
Industry Sector
Industry Automation Division
Sensors and Communication
Postfach 48 48
90026 NRNBERG
GERMANY
Umschlag_Katalog_KT10_1_2012_en.indd 1 17.10.2011 17:34:33
Siemens AG 2011

You might also like