Skip to content

Latest commit

 

History

History
 
 

windowseventlogreceiver

Windows Log Event Receiver

Status
Stability alpha
Supported pipeline types logs
Distributions none

Tails and parses logs from windows event log API using the opentelemetry-log-collection library.

Configuration Fields

Field Default Description
channel required The windows event log channel to monitor
max_reads 100 The maximum number of records read into memory, before beginning a new batch
start_at end On first startup, where to start reading logs from the API. Options are beginning or end
poll_interval 1s The interval at which the channel is checked for new log entries. This check begins again after all new bodies have been read.
attributes {} A map of key: value pairs to add to the entry's attributes.
resource {} A map of key: value pairs to add to the entry's resource.
operators [] An array of operators. See below for more details
converter
{
max_flush_count: 100,
flush_interval: 100ms,
worker_count: max(1,runtime.NumCPU()/4)
}
A map of key: value pairs to configure the [entry.Entry][entry_link] to [pdata.LogRecord][pdata_logrecord_link] converter, more info can be found [here][converter_link]

Operators

Each operator performs a simple responsibility, such as parsing a timestamp or JSON. Chain together operators to process logs into a desired format.

  • Every operator has a type.
  • Every operator can be given a unique id. If you use the same type of operator more than once in a pipeline, you must specify an id. Otherwise, the id defaults to the value of type.
  • Operators will output to the next operator in the pipeline. The last operator in the pipeline will emit from the receiver. Optionally, the output parameter can be used to specify the id of another operator to which logs will be passed directly.
  • Only parsers and general purpose operators should be used.

Additional Terminology and Features

  • An entry is the base representation of log data as it moves through a pipeline. All operators either create, modify, or consume entries.
  • A field is used to reference values in an entry.
  • A common expression syntax is used in several operators. For example, expressions can be used to filter or route entries.
  • timestamp parsing is available as a block within all parser operators, and also as a standalone operator. Many common timestamp layouts are supported.
  • severity parsing is available as a block within all parser operators, and also as a standalone operator. Stanza uses a flexible severity representation which is automatically interpreted by the stanza receiver.

Example Configurations

Simple

Configuration:

receivers:
    windowseventlog:
        channel: application

Output entry sample:

{
    "channel": "Application",
    "computer": "computer name",
    "event_id":
    {
        "id": 10,
        "qualifiers": 0
    },
    "keywords": "[Classic]",
    "level": "Information",
    "message": "Test log",
    "opcode": "Info",
    "provider":
    {
        "event_source": "",
        "guid": "",
        "name": "otel"
    },
    "record_id": 12345,
    "system_time": "2022-04-15T15:28:08.898974100Z",
    "task": ""
}