Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

how to added fixed address and channel #10

Closed
cyberumut opened this issue Mar 17, 2023 · 13 comments
Closed

how to added fixed address and channel #10

cyberumut opened this issue Mar 17, 2023 · 13 comments

Comments

@cyberumut
Copy link

how to added fixed address and channel ?

i need address & channel
as in the picture
image

@nopnop2002
Copy link
Owner

nopnop2002 commented Mar 17, 2023

Where is your drawing from?

I can't find it in the SX1276/77/78/79 datasheet.

@cyberumut
Copy link
Author

ebyte modules
Isn't this header structure global?
targetAddr | TargetChannel | Data
how can i apply this on sx1278

Where is your drawing from?

I can't find it in the SX1276/77/78/79 datasheet.

@nopnop2002
Copy link
Owner

nopnop2002 commented Mar 17, 2023

Where can I get your documentation?

tell me the url.

this is LoRa Packet Structure

LoRa

@cyberumut
Copy link
Author

https://www.cdebyte.com/products/E22-400T30D/4#Downloads

check it manual .pdf

LoRa Packet Structure

@nopnop2002
Copy link
Owner

EBYTE's E22 module uses different frequencies depending on the channel.

LoRa-2

you can use any frequency you like in menuconfig

LoLa-3

@cyberumut
Copy link
Author

module in hand is sx1278 ,not ebyte module
I want to define address and channel on sx1278
how can i do ?

EBYTE's E22 module uses different frequencies depending on the channel.

LoRa-2

you can use any frequency you like in menuconfig

LoLa-3

@nopnop2002
Copy link
Owner

This diagram you showed is from EBYTE.

225991844-2114696d-9406-4662-94eb-fe26c9045a5d

You're using EBYTE's SX1278, right?

@cyberumut
Copy link
Author

cyberumut commented Mar 17, 2023

no i dont using eybte module .
I just want to set up addressing and channel structure like it

This diagram you showed is from EBYTE.

225991844-2114696d-9406-4662-94eb-fe26c9045a5d

You're using EBYTE's SX1278, right?

@nopnop2002
Copy link
Owner

nopnop2002 commented Mar 17, 2023

The LoRa specification does not have channels or addresses.

EBYTE modules channel is same as frequency

For modules other than EBYTE, change the frequency if you use the concept of channels.

I recommend reading the SX1278 datasheet.

@cyberumut
Copy link
Author

cyberumut commented Mar 17, 2023

If we add such a structure to the header. I think it can work if we parse the header on the other device or
i selected channel 4
Frequency= 410.125 + CH * 1M
410.125+ 4*1M
using channel 414.125 example .
it needs to be calculated
image

The LoRa specification does not have channels or addresses.

EBYTE modules channel is same as frequency

For modules other than EBYTE, change the frequency if you use the concept of channels.

@nopnop2002
Copy link
Owner

nopnop2002 commented Mar 17, 2023

I do not understand your content.

The LoRa packet structure is the following structure and Header is optional.

The LoRa packet structure and header content are strictly specified and cannot be changed.

LoRa

Header
Depending upon the chosen mode of operation two types of header are available. The header type is selected by the
ImplicitHeaderModeOn bit found within the RegModemConfig1 register.

Explicit Header Mode
This is the default mode of operation. Here the header provides information on the payload, namely:
 The payload length in bytes.
 The forward error correction code rate
 The presence of an optional 16-bits CRC for the payload.
The header is transmitted with maximum error correction code (4/8). It also has its own CRC to allow the receiver to
discard invalid headers.



Implicit Header Mode
In certain scenarios, where the payload, coding rate and CRC presence are fixed or known in advance, it may be
advantageous to reduce transmission time by invoking implicit header mode. In this mode the header is removed from the
packet. In this case the payload length, error coding rate and presence of the payload CRC must be manually configured
on both sides of the radio link.
Note With SF = 6 selected, implicit header mode is the only mode of operation possible.

@nopnop2002
Copy link
Owner

nopnop2002 commented Mar 17, 2023

EBYTE LoRa modules and non-EBYTE LoRa modules may not be able to communicate with each other.

This is because EBYTE has the concept of addresses, but LoRa modules other than EBYTE do not.

Presumably the EBYTE address is sent as part of the LoRa payload.
This is an EBYTE-specific payload.

EBYTE-specific payloads cannot be interpreted correctly by non-EBYTE LoRa modules.

@cyberumut
Copy link
Author

i got it now thank u bro

EBYTE LoRa modules and non-EBYTE LoRa modules may not be able to communicate with each other.

This is because EBYTE has the concept of addresses, but LoRa modules other than EBYTE do not.

Presumably the EBYTE address is sent as part of the LoRa payload. This is an EBYTE-specific payload.

EBYTE-specific payloads cannot be interpreted correctly by non-EBYTE LoRa modules.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment