Missing Battery States in HA (Growatt MOD 10000TL3-XH BP) #84

Open
DMuenster opened this issue Mar 23, 2024 · 6 comments
Open

Missing Battery States in HA (Growatt MOD 10000TL3-XH BP) #84

DMuenster opened this issue Mar 23, 2024 · 6 comments

Comments

@DMuenster
Copy link

Hallo @muppet3000 ,

First of all, thank you very much for the great work! However, I have a question where you could possibly help me? I have a Growatt MOD 10000TL3-XH BP with a battery and unfortunately I cannot see the battery values displayed in HA. Am I doing something wrong?

Current setup:

  • Add On Grott Beta branch 2.8 Beta - Config "Default"
  • Grott from HACS

Data is also transmitted, but not that of the battery.

Thank you very much

Best regards
Dennis

@muppet3000
Copy link
Owner

Can you please post a copy of your logs from Grott here so I can see what sensors are being published to mqtt.

Also, can you please try installing the 'main' release of this integration instead of the last release, it's possible that I've added all the sensors in the most recent Dev with but haven't published it as a formal release yet.

Happy to help if you're still having problems after that.

@DMuenster
Copy link
Author

Danke für die schnelle Antwort! Blöde frage, aber wie komme ich an die Grott Logs? :)

@muppet3000
Copy link
Owner

Ahhh, I didn't read your last message correctly, you're using the addon.

I think there are some logs published for that under the addon itself, try looking there. I'll send you an example tomorrow if needed.

In the meantime can you just try using the latest 'main' version of my integration and see if that works?

@DMuenster
Copy link
Author

Unfortunately, installing the main version did not result in any improvement. That's why I would like to accept the small instructions for the logs. Thank you

@muppet3000
Copy link
Owner

I don't run Home Assistant with supervisor (aka the one that supports Addons) so I'm not sure how to do this myself.
@egguy - Are you able to advise on how to get the logs from Grott when running the addon??

@DMuenster - If it helps this forum post shows a way that you can get logs but I'm not sure how up-to-date it is: https://community.home-assistant.io/t/where-are-the-hassio-addon-logs-stored/30060/12

The specific logs I'm looking for are like this:

- Grott values retrieved:                                                                                                                                                                                                                                                                                 [31/49014]
                 -  datalogserial        :  NAC3915162
                 -  pvserial             :  NWCPA47006
                 -  pvstatus             :  5
                 -  pvpowerin            :  30.0
                 -  pv1voltage           :  370.7
                 -  pv1current           :  0.0
                 -  pv1watt              :  5.9
                 -  pv2voltage           :  206.6
                 -  pv2current           :  0.1
                 -  pv2watt              :  26.5
                 -  pvpowerout           :  357.0
                 -  pvfrequentie         :  49.8
                 -  pvgridvoltage        :  241.0
                 -  pvgridcurrent        :  1.9
                 -  pvgridpower          :  353.6
                 -  pvgridvoltage2       :  0.0                                                                                                                                                                                                                                                                                               -  pvgridcurrent2       :  0.0                                                                                                                                                                                                                                                                                               -  pvgridpower2         :  0.0
                 -  pvgridvoltage3       :  0.0                                                                                                                                                                                                                                                                                               -  pvgridcurrent3       :  0.0
                 -  pvgridpower3         :  0.0
                 -  totworktime          :  24784.3
                 -  eactoday             :  1.9
                 -  pvenergytoday        :  1.9
                 -  eactotal             :  21337.6
                 -  epvtotal             :  16469.6
                 -  epv1today            :  0.0
                 -  epv1total            :  9839.5
                 -  epv2today            :  0.0
                 -  epv2total            :  5156.6
                 -  pvtemperature        :  26.6
                 -  pvipmtemperature     :  24.6
                 -  pvboosttemp          :  24.5
                 -  bat_dsp              :  53.2
                 -  eacharge_today       :  8.2
                 -  eacharge_total       :  7400.2
                 -  batterytype          :  1
                 -  uwsysworkmode        :  5
                 -  systemfaultword0     :  0
                 -  systemfaultword1     :  0
                 -  systemfaultword2     :  0
                 -  systemfaultword3     :  0
                 -  systemfaultword4     :  0
                 -  systemfaultword5     :  0
                 -  systemfaultword6     :  0
                 -  systemfaultword7     :  0
                 -  pdischarge1          :  410.0
                 -  p1charge1            :  0.0
                 -  vbat                 :  52.9
                 -  SOC                  :  0.8
                 -  pactouserr           :  278.2
                 -  pactousertot         :  278.2
                 -  pactogridr           :  0.0
                 -  pactogridtot         :  0.0
                 -  plocaloadr           :  710.0
                 -  plocaloadtot         :  710.0
                 -  spdspstatus          :  0.5
                 -  spbusvolt            :  297.9
                 -  etouser_tod          :  12.5
                 -  etouser_tot          :  17345.9
                 -  etogrid_tod          :  0.0
                 -  etogrid_tot          :  31279.2
                 -  edischarge1_tod      :  2.1
                 -  edischarge1_tot      :  11072.6
                 -  eharge1_tod          :  7.5
                 -  eharge1_tot          :  10027.1
                 -  elocalload_tod       :  7.2
                 -  elocalload_tot       :  3581.8
         - MQTT jsonmsg:
                         {"device": "NWCPA47006", "time": "2024-03-24T07:02:49", "buffered": "no",
                         "values": {"datalogserial": "NAC3915162", "pvserial": "NWCPA47006",
                         "pvstatus": 5, "pvpowerin": 300, "pv1voltage": 3707, "pv1current": 0,
                         "pv1watt": 59, "pv2voltage": 2066, "pv2current": 1, "pv2watt": 265,
                         "pvpowerout": 3570, "pvfrequentie": 4982, "pvgridvoltage": 2410,
                         "pvgridcurrent": 19, "pvgridpower": 3536, "pvgridvoltage2": 0,
                         "pvgridcurrent2": 0, "pvgridpower2": 0, "pvgridvoltage3": 0,
                         "pvgridcurrent3": 0, "pvgridpower3": 0, "totworktime": 178446730,
                         "eactoday": 19, "pvenergytoday": 19, "eactotal": 213376, "epvtotal": 164696,
                         "epv1today": 0, "epv1total": 98395, "epv2today": 0, "epv2total": 51566,
                         "pvtemperature": 266, "pvipmtemperature": 246, "pvboosttemp": 245,
                         "bat_dsp": 532, "eacharge_today": 82, "eacharge_total": 74002,
                         "batterytype": 1, "uwsysworkmode": 5, "systemfaultword0": 0,
                         "systemfaultword1": 0, "systemfaultword2": 0, "systemfaultword3": 0,
                         "systemfaultword4": 0, "systemfaultword5": 0, "systemfaultword6": 0,

@DMuenster
Copy link
Author

Hello muppet3000,
sorry that I haven't contacted you in so long. But I've got it working now. I have briefly attached the correct settings for a Growatt MOD 10000TL3-XH BP with APX Battery.

HA add-on:

  • Grott Beta branch 2.8 Beta - Config "Inverter Type "MIN""
    HACS:
  • Grott in the "Main" version

Then you get (for me) 77 identities and also the ones you want from the battery. The request can then be closed again.

Nevertheless, thank you very much for your help!
Best regards

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment