ReinerSCT cyberJack Komfort/Standard: SCARD_E_NOT_TRANSACTED #1

Closed
misery opened this issue Jul 21, 2017 · 2 comments
Closed

ReinerSCT cyberJack Komfort/Standard: SCARD_E_NOT_TRANSACTED #1

misery opened this issue Jul 21, 2017 · 2 comments
Assignees

Comments

@misery
Copy link
Owner

misery commented Jul 21, 2017

Authentication with a cyberJack komfort/standard fails with "SCARD_E_NOT_TRANSACTED" after user enters PIN.

Establish connection using PIN
Starting PACE for PACE_PIN
SCardControl cmdBuffer: "02040303157f4c12.....1bda"
SCardControl for "REINER SCT cyberJack RFID komfort (9721581331) 00 00" : "SCARD_E_NOT_TRANSACTED" ""
Control to establish PACE channel failed
Finished PACE for PACE_PIN with result COMMAND_FAILED

This looks like a pcsc driver bug.

@misery misery self-assigned this Jul 24, 2017
@misery
Copy link
Owner Author

misery commented Jul 25, 2017

Added bug to upstream: LudovicRousseau/PCSC#22

@misery
Copy link
Owner Author

misery commented Feb 26, 2019

Fixed by eab3615.

@misery misery closed this as completed Feb 26, 2019