RCA - Russell St 2 #61

Closed
ak6492 opened this issue Jun 9, 2023 · 6 comments
Closed

RCA - Russell St 2 #61

ak6492 opened this issue Jun 9, 2023 · 6 comments
Labels
fault_failed_battery Battery failed - doesnt hold charge, doesnt charge

Comments

@ak6492
Copy link
Contributor

ak6492 commented Jun 9, 2023

Sensor Deployed:

  • March 5, 2021 by FloodNet

Sensor Version:

  • v2.0.

Firmware Version:

Sensor Down:

  • April 3, 2023 19:23

Solution Implemented:

  • whole sensor replaced on June 7, 2023 with another v2.0.

In Lab RCA:

  • antenna was perfectly intact
  • no visible rusting or corrosion both internally and externally
  • battery in sensor completely drained and dead
  • solar panel outputting voltage and increases it's output voltage when light is shined on it thus proving it is functioning correctly
  • sensor booted back up when new battery was inserted into it

deployment_id: easily_dear_mouse

dev_id: fs-00023

Fixes/Action:
In conclusion, sensor appears to have gone down due to the battery dying completely and being unable to retain charge from solar panel. The reason behind this seems to be the battery just being out in the field for about two years and going through its natural battery life cycle. Need to track about how long after being out in the field, batteries stop being functional to try to get ahead of sensors going down due to faulty old batteries.

@ak6492 ak6492 added the RCA Root-Cause-Analysis label Jun 9, 2023
@mprafull1
Copy link
Contributor

In Lab RCA:
Battery didn't got charged even when connected to the charger.

@ak6492
Copy link
Contributor Author

ak6492 commented Jul 10, 2023

Sensor replaced on 06/07, went down again on 06/09, data analysis shows the following:

russell 2 rcs

russell rca 2 x

russell rca 2 xx

Signal Strength looks good, battery is trending down rapidly and not charging

@ak6492
Copy link
Contributor Author

ak6492 commented Jul 12, 2023

07/11 On Site Analysis:

battery was visibly puffed up. ended up replacing battery and solar panel.

@mprafull1
Copy link
Contributor

Battery was dead also but it charged in the lab.

@ak6492 ak6492 added fault_failed_battery Battery failed - doesnt hold charge, doesnt charge and removed RCA Root-Cause-Analysis labels Oct 6, 2023
@ak6492
Copy link
Contributor Author

ak6492 commented Nov 10, 2023

Sensor data has repeatedly been noisy. On site visit on 11/09 did not reveal any visible sign of what might be causing the noise. Nothing was obstructing the sensor and there was no grass or spiderwebs inside the pipe. Need to observe and understand this issue further.

IMG_4752

@ak6492
Copy link
Contributor Author

ak6492 commented Feb 16, 2024

sensor removed on 02/15

@ak6492 ak6492 closed this as completed Feb 16, 2024