migrated from Bugzilla #465384
status RESOLVED severity normal in component Mosquitto for 1.4
Reported in version 1.4 on platform PC
Assigned to: Roger Light
On 2015-04-24 04:45:51 -0400, Roger Light wrote:
Reported on the mailing list:
seems that started with the version 1.4 I'm not able to use the bridge between two broker running on the same node:
broker A: without a config file, just default values
broker B: config file:
....
Port to use for the default listener.
port 1884
....
connection MA
address localhost:1883
topic a1/b1 both 2
clientid MyBridgeClient
....
Same config file works with version 1.3.5.
Compiled the broker version 1.4.1 using VC2010 and got the following error when debugging the bridge connection:
"Run-Time Check Failure # 2 - Stack around the variable 'err' was corrupted."
file "Loop.c" / line 511
broker started normal and was working fine when I continued with debugging.
Maybe this helps to find a bug in version 1.4ff, maybe I did something wrong.
On 2015-04-24 05:52:41 -0400, Roger Light wrote:
Fixed for 1.4.2.