VBat conductor shorted to ground on PCB #14
Comments
Should note that this is for the V2 board version. |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
The VBat conductor between the Sparkfun TOL 10617 battery positive pin and the BAT/BAT 2 inputs to the MAX8903A charge management IC U2 (pins 21 & 20) is shorted to ground on the PCB by a flood-filled polygon zone. This is on the top copper layer. The design rule checker does not mark the intersection of the polygon with the track as a problem.
The net result is that U2 (MAX8903A) fails to regulate properly and the board fails to operate (dead short/no voltage). With the battery pack connected, the pack delivers peak current (3x 5A) to ground, with the associated fire risk due to battery failure.
An image of the polygon:
An image of the resulting top copper gerber:
The work-around is a careful scalpel cut along the edge of the track to separate the polygon from ground.