Notifications
You must be signed in to change notification settings - Fork 5
/
ems_messages.py
448 lines (378 loc) · 18.9 KB
/
ems_messages.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
'''
Message definitions for the EMS bus
'''
import logging
from ems_bus.ems_units import \
UnitMinute, UnitYesNo, UnitOpenClosed, UnitOnOff, UnitCelsius, UnitPercent, UnitMicroAmpere, \
UnitBar, UnitLiterPerMin, UnitDwLoading, UnitDwMode, UnitDwType, UnitDevice, \
UnitHcInstallation, UnitHcWorkMode, UnitHcRemote, UnitHcOperation, UnitUbaMsTimestamp, \
UnitHour, UnitWeekDay, UnitUbaMmNeed, UnitUbaFtValve, UnitHwDcProgram, UnitOffOnAuto
from ems_bus.ems_fields import Field, DateTimeField, IntegerField, BooleanField, StringField, \
BooleanIntegerField, DateField
LOGGER = logging.getLogger(__name__)
LOGGER.setLevel(logging.DEBUG)
class Message:
message = None
def __init__(self, dev_id, proto):
self.device_id = dev_id
self.proto = proto
self.message = bytearray(self.Meta.length)
class Meta:
identification = 0x00
length = 0
def get_fields(self):
for field_name in dir(self):
field_obj = getattr(self, field_name)
if issubclass(field_obj.__class__, Field):
yield (field_name, field_obj)
def parse(self, update, offset):
if offset < 0:
LOGGER.error('Offset %d must be positive', offset)
return
if len(update) + offset > self.Meta.length:
LOGGER.error('Offset %d + length %d is greater than message length %d',
offset, len(update), self.Meta.length)
return
# Check what fields have changed, merge data and mark updated fields.
changed_fields = []
update_end = offset + len(update)
for field_name, field in self.get_fields():
if field.pos < offset or field.pos >= update_end:
continue
# Check field in range
field_end = field.pos + field.length
if field_end > update_end:
LOGGER.error('Update message 0x%02d range [%d-%d] not covering whole field %s',
self.Meta.identification, offset, update_end, field_name)
continue
if field.has_changed(update, offset, self.message) and field not in changed_fields:
changed_fields.append(field)
# Merge data
self.message[offset:update_end] = update
# Update marked fields after data was merged.
for field in changed_fields:
field.parse(self.message)
return(changed_fields)
def field_set_send(self, field, value):
''' Update a field and send the update to the device '''
field_obj = getattr(self, field)
field_obj.update(value)
update_data = field_obj.to_bytes(self)
data = bytearray(5 + len(update_data)) # 1 byte per src, dst, type, offset, crc
data[0] = self.proto.client_id
data[1] = self.device_id
data[2] = self.Meta.identification
data[3] = field_obj.pos
data[4:4 + field_obj.length] = update_data
#self.proto.bus.send(data)
self.proto._tx_queue.send(data)
def dump(self):
''' Print the values of the message to the logger '''
for field in dir(self):
field_obj = getattr(self, field)
if issubclass(field_obj.__class__, Field):
LOGGER.debug(str(field_obj))
class VersionMessage(Message):
class Meta:
identification = 0x02
length = 3
product_id = IntegerField(0, 1, 'Product ID')
ver_major = IntegerField(1, 1, 'Version Major')
ver_minor = IntegerField(2, 1, 'Version Minor')
class RCTimeMessage(Message):
class Meta:
identification = 0x06
length = 8
time = DateTimeField(0, 6, 'Time')
dow = IntegerField(6, 1, 'Day of week')
dst = BooleanField(7, 1, 'Daylight saving', None, 0)
radio = BooleanField(7, 1, 'Radio clock', None, 1)
bad_time = BooleanField(7, 1, 'Time incorrect', None, 2)
bad_date = BooleanField(7, 1, 'Date incorrect', None, 3)
enabled = BooleanField(7, 1, 'Clock enabled', None, 4)
class UbaDevicesMessage(Message):
class Meta:
identification = 0x07
length = 13
def __init__(self, dev_id, proto, *args, **kwargs):
super().__init__(dev_id, proto, *args, **kwargs)
for num_byte in range(8):
for num_bit in range(8):
num_str = '{:02d}'.format((num_byte + 1) * 8 + num_bit)
setattr(self, 'device_' + num_str,
BooleanField(num_byte, 1, 'Device ' + num_str, UnitDevice, num_bit))
class ErrorMessage(Message):
display = StringField(0, 2, 'Display code')
code = IntegerField(2, 2, 'Error code')
timestamp = DateTimeField(4, 5, 'Time stamp')
duration = IntegerField(9, 2, 'Duration', UnitMinute)
source = IntegerField(11, 1, 'Source bus address')
class UbaError1Message(ErrorMessage):
class Meta:
identification = 0x10
length = 96
class UbaError2Message(ErrorMessage):
class Meta:
identification = 0x11
length = 96
class RcErrorMessages(ErrorMessage):
class Meta:
identification = 0x12
length = 96
class RcResetErrorMessages(ErrorMessage):
class Meta:
identification = 0x13
length = 96
class UbaOperationTime(Message):
class Meta:
identification = 0x14
length = 3
duration = IntegerField(0, 3, 'Operation duration', UnitMinute)
# Todo
class UbaMaintenanceSettings(Message):
class Meta:
identification = 0x15
length = 5
timstamp_unit = IntegerField(0, 1, 'Maintenance log timestamp unit', UnitUbaMsTimestamp)
remaining_time = IntegerField(1, 1, 'Remaining time to next maintenance', UnitHour, 0.01)
next_maintenance = DateField(2, 3, 'Date of next maintenance')
class UbaSettings(Message):
class Meta:
identification = 0x16
length = 11
boiler_heating = BooleanIntegerField(0, 1, 'Boiler heating activated', UnitOnOff, 0xff)
boiler_temp = IntegerField(1, 1, 'Boiler heating temperature', UnitCelsius, None, True)
boiler_max = IntegerField(2, 1, 'Maximum boiler power', UnitPercent)
boiler_min = IntegerField(3, 1, 'Minimum boiler power', UnitPercent)
stop_hysteresis = IntegerField(4, 1, 'Stop hysteresis', UnitCelsius, None, True)
start_hysteresis = IntegerField(5, 1, 'Start hysteresis', UnitCelsius, None, True)
anti_swing_time = IntegerField(6, 1, 'Anti-swinging time', UnitMinute)
follow_up_time = IntegerField(8, 1, 'Boiler stop follow up time', UnitMinute)
pump_max = IntegerField(9, 1, 'Heat circuit pump maximum power', UnitPercent)
pump_min = IntegerField(10, 1, 'Heat circuit pump minimum power', UnitPercent)
class UbaMonitorFast(Message):
class Meta:
identification = 0x18
length = 25
forward_temp_set = IntegerField(0, 1, 'Set forward flow temperature', UnitCelsius, None, True)
forward_temp = IntegerField(1, 2, 'Current forward flow temperature', UnitCelsius, 10, True)
burner_power_max = IntegerField(3, 1, 'Maximum burner power', UnitPercent)
burner_power = IntegerField(4, 1, 'Current burner power', UnitPercent)
# 2 bytes missing
valve1 = BooleanField(7, 1, 'Gas valve 1', UnitOpenClosed, 0)
valve2 = BooleanField(7, 1, 'Gas valve 2', UnitOpenClosed, 1)
fan = BooleanField(7, 1, 'Fan', UnitOnOff, 2)
ignition = BooleanField(7, 1, 'Ignition', UnitOnOff, 3)
boiler_pump = BooleanField(7, 1, 'Boiler pump', UnitOnOff, 4)
drinkwater_valve = BooleanField(7, 1, 'Drink water valve', UnitOpenClosed, 5)
drinkwater_pump = BooleanField(7, 1, 'Drink water circulation pump', UnitOnOff, 6)
# 1 byte missing
boiler_temp = IntegerField(9, 2, 'Boiler temperature', UnitCelsius, 10, True)
drinkwater_temp = IntegerField(11, 2, 'Drink water temperature', UnitCelsius, 10, True)
return_current = IntegerField(13, 2, 'Current return flow temperature', UnitCelsius, 10, True)
flame_power = IntegerField(15, 2, 'Flame current', UnitMicroAmpere, 10)
pressure = IntegerField(17, 1, 'System pressure', UnitBar, 10)
service_code = StringField(18, 2, 'Service code')
error_code = IntegerField(20, 2, 'Error code')
intake_temp = IntegerField(23, 2, 'Intake temperature', UnitCelsius, 10, True)
# 1 byte missing
class UbaMonitorSlow(Message):
class Meta:
identification = 0x19
length = 25
outside_temp = IntegerField(0, 2, 'Outside temperature', UnitCelsius, 10, True)
boiler_temp = IntegerField(2, 2, 'Boiler temperature', UnitCelsius, 10, True)
exhaust_temp = IntegerField(4, 2, 'Exhaust temperature', UnitCelsius, 10, True)
# 3 bytes missing
pump_power = IntegerField(9, 1, 'Pump power', UnitPercent)
burner_starts = IntegerField(10, 3, 'Burner starts')
burner_total = IntegerField(13, 3, 'Burner total operation time', UnitMinute)
burner_stage2 = IntegerField(16, 3, 'Burner time in stage 2', UnitMinute)
burner_heat = IntegerField(19, 3, 'Burner time heating', UnitMinute)
burner_drinkwater = IntegerField(22, 3, 'Burner time heating drink water', UnitMinute)
class UbaSetValuesMessage(Message):
class Meta:
identification = 0x1a
length = 4
write = True
boiler_temp = IntegerField(0, 1, 'Boiler set temperature', UnitCelsius, None, True)
heat_power = IntegerField(1, 1, 'Heat circuit power', UnitPercent)
drinkwater_power = IntegerField(2, 1, 'Requested drink water power', UnitPercent)
# 1 byte missing
class UbaMaintenanceMessage(Message):
class Meta:
identification = 0x1c
length = 1
need_maintenance = IntegerField(0, 1, 'Maintenance neccessary', UnitUbaMmNeed)
class UbaFunctionTest(Message):
class Meta:
identification = 0x1d
length = 11
test_on = BooleanIntegerField(0, 1, 'Test mode activated', UnitOnOff, 0x5a)
burner_power = IntegerField(1, 1, 'Burner power', UnitPercent)
# 1 byte missing
boiler_power = IntegerField(3, 1, 'Boiler power', UnitPercent)
valve = IntegerField(4, 1, '3-way-valve setting', UnitUbaFtValve)
pump_on = BooleanIntegerField(5, 1, 'Heat circuit pump', UnitOnOff, 0xff)
# 5 byte missing
class UbaDrinkwaterParameterMessage(Message):
class Meta:
identification = 0x33
length = 11
write = True
installed = BooleanField(0, 1, 'Drink water system installed', UnitYesNo, 3)
activated = BooleanIntegerField(1, 1, 'Drink water system activated', UnitYesNo, 0xff)
set_temp = IntegerField(2, 1, 'Drink water set temperature', UnitCelsius, None, True)
pump_installed = BooleanIntegerField(6, 1, 'Drink water circulation pump installed', UnitYesNo, 0xff)
pump_cycle = IntegerField(7, 1, 'Drink water circulation pump switch cycle', UnitMinute, 1 / 3)
desinfection_temp = IntegerField(8, 1, 'Drink water thermal desinfection temperature', UnitCelsius, None, True)
mode = IntegerField(9, 1, 'Drink water operation mode', UnitDwMode)
use_valve = IntegerField(10, 1, 'Drink water loading system type', UnitDwLoading)
class UbaDrinkwaterMonitorMessage(Message):
class Meta:
identification = 0x34
length = 16
set_temp = IntegerField(0, 1, 'Drink water set temperature', UnitCelsius, None, True)
sensor1_temp = IntegerField(1, 2, 'Drink water sensor 1 temperature', UnitCelsius, 10, True)
sensor2_temp = IntegerField(3, 2, 'Drink water sensor 2 temperature', UnitCelsius, 10, True)
day_mode = BooleanField(5, 1, 'Drink water day mode', UnitYesNo, 0)
oneshot = BooleanField(5, 1, 'Drink water one shot heating', UnitYesNo, 1)
desinfection = BooleanField(5, 1, 'Drink water thermal desinfection running', UnitYesNo, 2)
enabled = BooleanField(5, 1, 'Drink water heating enabled', UnitYesNo, 3)
reheat = BooleanField(5, 1, 'Drink water re-heating', UnitYesNo, 4)
set_reached = BooleanField(5, 1, 'Drink water set temperature reached', UnitYesNo, 5)
sens1err = BooleanField(6, 1, 'Drink water sensor 1 error', UnitYesNo, 0)
sens2err = BooleanField(6, 1, 'Drink water sensor 2 error', UnitYesNo, 1)
desinfect_error = BooleanField(6, 1, 'Drink water thermal desinfection error', UnitYesNo, 2)
pump_day = BooleanField(7, 1, 'Drink water ciculation in day mode', UnitYesNo, 3)
pump_manual = BooleanField(7, 1, 'Drink water circulation in manual mode', UnitYesNo, 4)
pump_on = BooleanField(7, 1, 'Drink water circulation pump', UnitYesNo, 3)
heating = BooleanField(7, 1, 'Drink water currently heating', UnitYesNo, 3)
system_type = IntegerField(8, 1, 'Drink water system type', UnitDwType)
current_flow = IntegerField(9, 1, 'Drink water current flow', UnitLiterPerMin, 10)
heating_time = IntegerField(10, 3, 'Drink water total heating time', UnitMinute)
heating_runs = IntegerField(13, 3, 'Drink water total heating runs')
class FlagsMessage(Message):
class Meta:
identification = 0x35
length = 2
data1 = IntegerField(0, 1, 'Data 1')
data2 = IntegerField(0, 1, 'Data 2')
# https://emswiki.thefischer.net/doku.php?id=wiki:ems:telegramme#wwbetriebsart
class HcDrinkwaterParam(Message):
class Meta:
identification = 0x37
length = 10
write = True
heating_program = IntegerField(0, 1, 'Drinkwater heating program', UnitHwDcProgram)
circulation_program = IntegerField(1, 1, 'Drinkwater circulation program', UnitHwDcProgram)
operation = IntegerField(2, 1, 'Drinkwater operation mode', UnitOffOnAuto)
pump = IntegerField(3, 1, 'Drinkwater pump operation', UnitOffOnAuto)
desinfection_on = BooleanIntegerField(4, 1, 'Drinkwater thermal desinfection', UnitOnOff, 0xff)
desinfection_day = IntegerField(5, 1, 'Drinkwater thermal desinfection week day', UnitWeekDay)
desinfection_hour = IntegerField(6, 1, 'Drinkwater thermal desinfection hour', UnitHour)
desinfection_temp = IntegerField(8, 1, 'Drinkwater thermal desinfection maximum temperature', UnitCelsius, None, True)
one_shot = BooleanIntegerField(9, 1, 'One-shot drinkwater heating', UnitOnOff, 0xff)
class HcParamMessage(Message):
# 1 byte missing
install_type = IntegerField(0, 1, 'Installation type', UnitHcInstallation)
night_temp = IntegerField(1, 1, 'Night temperature', UnitCelsius, 2, True)
day_temp = IntegerField(2, 1, 'Day temperature', UnitCelsius, 2, True)
holiday_temp = IntegerField(3, 1, 'Holiday temperature', UnitCelsius, 2, True)
room_influence_temp = IntegerField(4, 1, 'Room influence temperature', UnitCelsius, 2, True)
# 1 byte missing
room_offset_temp = IntegerField(6, 1, 'Room offset temperature', UnitCelsius, 2, True)
operation = IntegerField(7, 1, 'Operating mode', UnitHcOperation)
screed_trying = BooleanIntegerField(8, 1, 'Screed drying', UnitOnOff, 0xff)
# 6 bytes missing
max_forward_temp = IntegerField(15, 1, 'Max forward flow temperature', UnitCelsius, None, True)
min_forward_temp = IntegerField(16, 1, 'Min forward flow temperature', UnitCelsius, None, True)
lay_out_temp = IntegerField(17, 1, 'Lay out temperature', UnitCelsius, None, True)
# 1 byte missing
onoff_optimization = BooleanIntegerField(19, 1, 'On/off optimization', UnitOnOff, 0xff)
summer_threshold = IntegerField(22, 1, 'Summer threshold', UnitCelsius, None, True)
antifreeze_temp = IntegerField(23, 1, 'Antifreeze temperature', UnitCelsius, None, True)
# 1 byte missing
work_mode = IntegerField(25, 1, 'Work mode', UnitHcWorkMode)
remote = IntegerField(26, 1, 'Remote model', UnitHcRemote)
# 1 byte missing
#antifreeze_mode = IntegerField(28, 1, 'Antifreeze mode', None)
# 3 bytes missing
#heat_system = IntegerField(32, 1, 'Heat system', None)
#control_type = IntegerField(33, 1, 'Control type', None)
# 1 byte missing
# 2 bytes missing
# 1 byte missing
class Hc1ParamMessage(HcParamMessage):
class Meta:
identification = 0x3D
length = 27
write = True
class Hc2ParamMessage(HcParamMessage):
class Meta:
identification = 0x47
length = 27
write = True
class Hc3ParamMessage(HcParamMessage):
class Meta:
identification = 0x51
length = 27
write = True
class Hc4ParamMessage(HcParamMessage):
class Meta:
identification = 0x5b
length = 27
write = True
class HcMonitorMessage(Message):
optimize_on = BooleanField(0, 1, 'Optimize turn off', UnitYesNo, 0)
optimize_off = BooleanField(0, 1, 'Optimize turn on', UnitYesNo, 1)
automatic_mode = BooleanField(0, 1, 'Automatic mode', UnitYesNo, 2)
drinkwater_preferred = BooleanField(0, 1, 'Drinkwater preferred', UnitYesNo, 3)
screed_mode = BooleanField(0, 1, 'Screed drying mode', UnitYesNo, 4)
vacation_mode = BooleanField(0, 1, 'Vacation mode', UnitYesNo, 5)
frost_protection = BooleanField(0, 1, 'Frost protection', UnitYesNo, 6)
manual = BooleanField(0, 1, 'Manual mode', UnitYesNo, 7)
summer_mode = BooleanField(1, 1, 'Summer mode', UnitYesNo, 0)
day_mode = BooleanField(1, 1, 'Day mode', UnitYesNo, 1)
remote_offline = BooleanField(1, 1, 'Remote offline', UnitYesNo, 2)
remote_error = BooleanField(1, 1, 'Remote error', UnitYesNo, 3)
forward_error = BooleanField(1, 1, 'Forward flow sensor error', UnitYesNo, 4)
forward_max = BooleanField(1, 1, 'Forward max flow', UnitYesNo, 5)
external_error = BooleanField(1, 1, 'External error', UnitYesNo, 6)
party_pause = BooleanField(1, 1, 'Party pause mode', UnitYesNo, 7)
room_set_temp = IntegerField(2, 1, 'Set room temperature', UnitCelsius, 2, True)
room_current_temp = IntegerField(3, 2, 'Current room temperature', UnitCelsius, 10, True)
optimize_on_time = IntegerField(5, 1, 'Optimize turn on time')
optimize_on_time = IntegerField(6, 1, 'Optimize turn off time')
curve_plus_10 = IntegerField(7, 1, 'Heating curve at -10 °C', None, None, True)
curve_plus_0 = IntegerField(8, 1, 'Heating curve at 0 °C', None, None, True)
curve_minus_10 = IntegerField(9, 1, 'Heating curve at 10 °C', None, None, True)
room_adaption = IntegerField(10, 2, 'Room temperature adaption speed', None, 100, True)
boiler_power = IntegerField(12, 1, 'Requested boiler power', UnitPercent)
party_state = BooleanField(13, 1, 'Party mode', UnitOnOff, 2)
pause_state = BooleanField(13, 1, 'Pause mode', UnitOnOff, 3)
vacation_state = BooleanField(13, 1, 'Vacation mode', UnitOnOff, 6)
holiday_state = BooleanField(13, 1, 'Holiday mode', UnitOnOff, 7)
forward_temp = IntegerField(14, 1, 'Calculated forward temp', UnitCelsius, None, True)
class Hc1MonitorMessage(HcMonitorMessage):
class Meta:
identification = 0x3E
length = 15
class Hc2MonitorMessage(HcMonitorMessage):
class Meta:
identification = 0x48
length = 15
class Hc3MonitorMessage(HcMonitorMessage):
class Meta:
identification = 0x52
length = 15
class Hc4MonitorMessage(HcMonitorMessage):
class Meta:
identification = 0x5c
length = 15
class RcOutdoorMessage(Message):
class Meta:
identification = 0xA3
length = 3
damped_temp = IntegerField(0, 1, 'Damped outdoor temperature', UnitCelsius, None, True)
# 2 bytes missing