organic matter model diag setting #41

Closed
aed-modeller opened this issue Feb 13, 2022 · 1 comment
Closed

organic matter model diag setting #41

aed-modeller opened this issue Feb 13, 2022 · 1 comment

Comments

@aed-modeller
Copy link

IF( extra_diag ) diag_level = 10 ! legacy use of extra_diag

The diag_level is fixed to 10 when the extra_diag is activated, but options of 0,1,2,3, and 10 are available in the code

@matthipsey
Copy link
Contributor

This is the intended operation. Users should input diag_level.
extra_diag is still included just for backward compatibility

diag_level can be read via the namelist

extra_diag, diag_level